首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 15 毫秒
1.
We studied dampness and mold in China in relation to rhinitis, ocular, throat and dermal symptoms, headache and fatigue. A questionnaire study was performed in six cities including 36 541 randomized parents of young children. Seven self‐reported signs of dampness were evaluated. Multilevel logistic regression models were used to calculate odds ratios (ORs). Totally, 3.1% had weekly rhinitis, 2.8% eye, 4.1% throat and 4.8% skin symptoms, 3.0% headache and 13.9% fatigue. Overall, 6.3% of the homes had mold, 11.1% damp stains, 35.3% damp bed clothing, 12.8% water damage, 45.4% window pane condensation, 11.1% mold odor, and 37.5% humid air. All dampness signs were associated with symptoms (ORs from 1.2 to 4.6; P < 0.001), including rhinitis (ORs from 1.4 to 3.2; P < 0.001), and ORs increased by number of dampness signs. The strongest associations were for mold odor (ORs from 2.3 to 4.6) and humid air (ORs from 2.8 to 4.8). Associations were stronger among men and stronger in Beijing as compared to south China. In conclusion, dampness and mold are common in Chinese homes and associated with rhinitis and ocular, throat and dermal symptoms, headache and fatigue. Men can be more sensitive to dampness and health effects of dampness can be stronger in northern China.  相似文献   

2.
In the Swedish Building Energy, Technical Status and Indoor environment study, a total of 1160 adults from 605 single‐family houses answered a questionnaire on respiratory health. Building inspectors investigated the homes and measured temperature, air humidity, air exchange rate, and wood moisture content (in attic and crawl space). Moisture load was calculated as the difference between indoor and outdoor absolute humidity. Totally, 7.3% were smokers, 8.7% had doctor’ diagnosed asthma, 11.2% current wheeze, and 9.5% current asthma symptoms. Totally, 50.3% had respiratory infections and 26.0% rhinitis. The mean air exchange rate was 0.36/h, and the mean moisture load 1.70 g/m3. Damp foundation (OR=1.79, 95% CI 1.16‐2.78) was positively associated while floor constructions with crawl space (OR=0.49, 95% CI 0.29‐0.84) was negatively associated with wheeze. Concrete slabs with overlying insulation (OR=2.21, 95% CI 1.24‐3.92) and brick façade (OR=1.71, 95% CI 1.07‐2.73) were associated with rhinitis. Moisture load was associated with respiratory infections (OR=1.21 per 1 g/m3, 95% CI 1.04‐1.40) and rhinitis (OR=1.36 per 1 g/m3, 95% CI 1.02‐1.83). Air exchange rate was associated with current asthma symptoms (OR=0.85 per 0.1/h, 95% CI 0.73‐0.99). Living in homes with damp foundation, concrete slabs with overlying insulation, brick façade, low ventilation flow, and high moisture load are risk factors for asthma, rhinitis, and respiratory infections.  相似文献   

3.
Few prospective studies exist on indoor and outdoor air pollution in relation to adolescent rhinitis. We studied associations between onset and remission of rhinitis among junior high school students in relation to the home and school environment. A 2‐year questionnaire cohort study was performed among 1325 students (11‐15 years) in eight schools in Taiyuan, Northern China. Climate and air pollution were measured by direct reading instruments and passive samplers inside and outside the schools at baseline. Associations were calculated by multilevel logistic regression. Two‐year onset of rhinitis and weekly rhinitis were 26.7% and 13.1%, respectively. RH (P < 0.001), CO2 (P < 0.01) and PM10 (P < 0.01) in the classrooms, PM10 (P < 0.01) and NO2 (P < 0.05) outside the schools, and redecoration (OR = 2.25) and dampness/indoor mold at home (OR = 2.04) were associated with onset of weekly rhinitis. RH (P < 0.05) and CO2 (P < 0.05) in the classroom and dampness/indoor mold (OR = 0.67) and environmental tobacco smoke (ETS) at home (OR = 0.63) reduced remission of rhinitis. In conclusion, dampness/mold and chemical emissions from new materials at home can increase onset of rhinitis and ETS and dampness/mold can reduce the remission. PM10, RH, CO2, and NO2 at school can increase the onset, and RH and CO2 can reduce the remission of rhinitis.  相似文献   

4.
The aim was to utilize data from a study of occupational indoor environments to analyze symptoms and physiological signs in relation to the home environment. A medical investigation was performed at the workplace among university staff (n = 173) from four university buildings in Bergen, in March 2004. Tear film break up time (BUT) was measured by two methods. Nasal patency was measured by acoustic rhinometry. Nasal lavage fluid analysis (NAL) included eosinophilic cationic protein (ECP); myeloperoxidase (MPO), lysozyme and albumin. Atopy was assessed by total serum IgE and specific IgE (Phadiatop). Totally 21%, 21%, 18%, 11%, and 27% had weekly ocular, nasal, facial dermal symptoms, headache and tiredness, respectively, 15% had a damp dwelling, and 20% had a cat or dog. Multiple linear or logistic regressions were applied, controlling for age gender, smoking, and environmental factors. Building dampness was associated with increased NAL-lysozyme (P = 0.02) and an increase of airway infections [odd ratio (OR) = 3.14, P = 0.04]. Pet keeping was associated with difficulties to concentrate (OR = 5.10, P = 0.001), heavy headedness (OR = 4.35, P = 0.004), four more days with tiredness per month (P = 0.04), and less airway infections (OR = 0.32; P = 0.02). In conclusion, pet keeping was associated with more central nervous system (CNS)-symptoms but less airway infections. Dampness in the dwelling may have inflammatory effects on the airway mucosa, possibly mediated via increased infection proneness. PRACTICAL IMPLICATIONS: The main health focus on pet keeping has been allergen exposure. Our study indicates that effects on airway infections and other types of symptoms should also be considered. The findings support the view that measures should be taken to reduce building dampness in dwellings.  相似文献   

5.
Engvall K  Norrby C  Norbäck D 《Indoor air》2003,13(3):206-211
The aim was to study relationships between symptoms compatible with the sick building syndrome, type of heating and ventilation system, energy saving, and reconstruction in older dwellings. In Stockholm, 4815 inhabitants in 231 multi-family buildings built before 1961 were randomly selected, of whom 3241 participated (77%). Symptoms and personal factors were assessed by a postal questionnaire. Independent information on building characteristics, and energy saving measures was gathered from the building owners. Multiple logistic regression analysis was applied to calculate odds ratios (OR) adjusting for age, gender, hay fever, current smoking, population density, type of ventilation, type of heating system, and ownership of the building. Subjects in buildings with a mechanical ventilation system had less ocular and nasal symptoms (OR = 0.29-0.85). Heating by electric radiators, and wood heating was associated with an increase of most symptoms (OR = 1.18-1.74). In total, 48% lived in buildings that had gone through at least one type of reconstruction or energy saving remedies during the latest 10 years, including exchange of heating or ventilation system, and sealing measures (exchange of windows, sealing of window frames, roof/attic insulation, and phasade insulation). Energy saving was associated with both a decrease and increase of different symptoms. Major reconstruction of the interior of the building was associated with an increase of most symptoms (OR = 1.09-1.90), and buildings with more than one sealing measure had an increase of ocular, nasal symptoms, headache and tiredness (OR = 1.22-2.49). In conclusion, major reconstruction of the interior, direct heated electric radiators, wood heating, and multiple sealing of buildings were associated with an increase of some symptoms. The study supports the view that mechanical ventilation in dwellings is beneficial from a health point of view.  相似文献   

6.
高层建筑内包容了众多的人员和发热设备,因此不合理的设计和运行将对室内人员的健康和舒适、经济性和能耗、全球环境等产生重大的影响。从工程实际和基本原理上探讨了暖通空调广泛领域内将遇到的一些重要课题,以实现协调这些方面要求的最优的暖通空调系统。  相似文献   

7.
We examined the associations between biomarkers of allergy and inflammation, indoor environment in dwellings, and incidence and remission of symptoms included in the sick building syndrome (SBS) and changes in the home environment of 452 adults who were followed from 1992 to 2002 within the Uppsala part of the European Community Respiratory Health Survey (ECRHS). The 10-year incidence (onset) of general, mucosal, and dermal symptoms was 8.5%, 12.7%, and 6.8%, respectively. Dampness or indoor molds at baseline was a predictor of incidence of general (relative risk [RR] = 1.98), mucosal (RR = 2.28), and dermal symptoms (RR = 1.91). Women had higher incidence of general (RR = 1.74) and mucosal symptoms (RR = 1.71). Indoor painting increased the incidence of general symptoms (RR = 1.62). Bronchial responsiveness (BR), eosinophil counts in blood, total IgE and eosinophilic cationic protein (ECP) in serum at baseline were predictors of incidence of SBS. At follow-up, BR, total IgE, and C-reactive protein (CRP ) were associated with increased incidence of SBS. Moreover, subjects with doctor-diagnosed asthma at baseline had a higher incidence of general (RR = 1.65) and mucosal symptoms (RR = 1.97). In conclusion, female gender, dampness or indoor molds, indoor painting, and biomarkers of allergy and inflammation were associated with a higher incidence of SBS symptoms, in particular mucosal symptoms. PRACTICAL IMPLICATIONS: The focus in Sweden on indoor environment issues over the last few decades has resulted in improvements in dwellings, and reduced tobacco smoking, which could be beneficial for public health. Reducing dampness and molds in the dwelling place is another important way of reducing occurrence of SBS symptoms in the general adult population. The association between the incidence of SBS symptoms and clinical biomarkers of allergy and inflammation suggests a common etiology between inflammatory diseases, including asthma, rhinitis, and SBS. Lastly, good agreement between self-reported and clinically diagnosed atopy indicates that questionnaire data on atopy can be used in epidemiological studies.  相似文献   

8.
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building‐related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools’ observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools’ psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school‐related stress, poor teacher–student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = ?0.43) and poor teacher–student relationship (standardized β = ?0.22) were significant predictors of poor subjective IAQ. In addition, school‐related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = ?0.44).  相似文献   

9.
The aim was to develop and validate a standardized questionnaire - the Stockholm Indoor Environment Questionnaire (SIEQ). The validation procedure was based on sociological principles and test procedures for validation. The indicators of indoor environment are air quality, thermal climate, noise, and illumination. The indicators of health are symptoms comprised in the sick building syndrome (SBS). The questionnaire also contains questions about the apartment, individual behavior, and personal factors. The everyday language describing the building and its function was first obtained by qualitative personal interviews, then by standardized questions. The interview questionnaire was transformed into a postal self-administered questionnaire. The reduction of the questionnaire was based on correlation analysis. It was found that to obtain a good validity, general questions are not sufficient, but specific question on perceptions and observations are needed. Good test-retest agreement was found both on an area level, building level, and individually. For each indicator, a set of questions are constructed and validated. SIEQ has been used in several studies, and the results are presented in graphic problem profiles. Reference data has been calculated for the Stockholm area.  相似文献   

10.
Zhang X  Zhao Z  Nordquist T  Norback D 《Indoor air》2011,21(6):462-471
There are few incidence studies on sick building syndrome (SBS). We studied two-year change of SBS in Chinese pupils in relation to parental asthma/allergy (heredity), own atopy, classroom temperature, relative humidity (RH), absolute humidity (AH), crowdedness, CO?, NO?, and SO?. A total of 1993 participated at baseline, and 1143 stayed in the same classrooms after two years. The prevalence of mucosal and general symptoms was 33% and 28% at baseline and increased during follow-up (P < 0.001). Twenty-seven percent reported at least one symptom improved when away from school. Heredity and own atopy were predictors of SBS at baseline and incidence of SBS. At baseline, SO? was associated with general symptoms (OR=1.10 per 100 μg/m3), mucosal symptoms (OR=1.12 per 100 μg/m3), and skin symptoms (OR=1.16 per 100 μg/m3). NO? was associated with mucosal symptoms (OR=1.13 per 10 μg/m3), and symptoms improved when away from school (OR=1.13 per 10 μg/m3). Temperature, RH, AH, and CO? were negatively associated with prevalence of SBS. Incidence or remission of SBS was not related to any exposure, except a negative association between SO? and new skin symptoms. In conclusion, heredity and atopy are related to incidence and prevalence of SBS, but the role of the measured exposures for SBS is more unclear. PRACTICAL IMPLICATIONS: We found high levels of CO? indicating inadequate ventilation and high levels of SO? and NO?, both indoors and outdoors. All schools had natural ventilation, only. Relying on window opening as a tool for ventilation in China is difficult because increased ventilation will decrease the level of CO? but increase the level of NO? and SO? indoors. Prevalence studies of sick building syndrome (SBS) might not be conclusive for causal relationships, and more longitudinal studies on SBS are needed both in China and other parts of the world. The concept of mechanical ventilation and air filtration should be introduced in the schools, and when planning new schools, locations close to heavily trafficked roads should be avoided.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号