首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Under sustained, elevated building moisture conditions, bacterial and fungal growth occurs. The goal of this study was to characterize microbial growth in floor dust at variable equilibrium relative humidity (ERH) levels. Floor dust from one home was embedded in coupons cut from a worn medium‐pile nylon carpet and incubated at 50%, 80%, 85%, 90%, 95%, and 100% ERH levels. Quantitative PCR and DNA sequencing of ribosomal DNA for bacteria and fungi were used to quantify growth and community shifts. Over a 1‐wk period, fungal growth occurred above 80% ERH. Growth rates at 85% and 100% ERH were 1.1 × 104 and 1.5 × 105 spore equivalents d?1 mg dust?1, respectively. Bacterial growth occurred only at 100% ERH after 1 wk (9.0 × 104 genomes d?1 mg dust?1). Growth resulted in significant changes in fungal (P<.00001) and bacterial community structure (P<.00001) at varying ERH levels. Comparisons between fungal taxa incubated at different ERH levels revealed more than 100 fungal and bacterial species that were attributable to elevated ERH. Resuspension modeling indicated that more than 50% of airborne microbes could originate from the resuspension of fungi grown at ERH levels of 85% and above.  相似文献   

2.
Airborne bacterial and fungal composition in an industrial town of Helwan, Egypt, was studied using a slit impactor sampler during the period from March 2006 to February 2007. Airborne bacterial concentrations were usually higher than fungi. Bacteria and fungi had similar diurnal variation patterns. Airborne microorganisms reached their concentration peaks in the evening and gradually decreased during the night time. The hourly concentration peaks of the bacteria and fungi appeared at 20:00 h. A significant difference (P ≤ 0.05) was found between the hourly mean concentrations of airborne fungi in winter compared to other seasons. Fungi concentrations were significantly higher (P ≤ 0.05) on working weekdays than weekends. Aspergillus, Penicillium, Alternaria and Cladosporium were the most predominant airborne fungal genera. Aspergillus showed double peak patterns whereas Penicillium, Alternaria and Cladosporium showed one peak pattern. The diurnal variations of the bacteria and fungi could be divided into four periods: 1) the morning maximum concentration (6:00 h-10:00 h), 2) midday to afternoon pattern (10:00 h-16:00 h), 3) the evening concentration peak (18:00 h-20:00 h) and 4) the gradual decrease of night time concentration (22:00 h-24:00 h). Geographical location, human activity, growth cycle of organisms and meteorological factors were the main criteria controlling the temporal variations of the air microorganisms in the Wadi Hof area.  相似文献   

3.
Indoor bioaerosols, such as mold spores, have been associated with respiratory symptoms in patients with asthma; however, dose–response relationships and guidelines on acceptable levels are lacking. Furthermore, a causal link between mold exposure and respiratory infections or asthma remains to be established. The aim of this study was to determine indoor concentrations of Aspergillus fumigatus and a subset of clinically relevant fungi in homes of people with asthma, in relation to markers of airways colonization and sensitization. Air and dust samples were collected from the living room of 58 properties. Fungal concentrations were quantified using mold‐specific quantitative PCR and compared with traditional microscopic analysis of air samples. Isolation of A. fumigatus from sputum was associated with higher airborne concentrations of the fungus in patient homes (P = 0.04), and a similar trend was shown with Aspergillus/Penicillium‐type concentrations analyzed by microscopy (P = 0.058). No association was found between airborne levels of A. fumigatus and sensitization to this fungus, or dustborne levels of A. fumigatus and either isolation from sputum or sensitization. The results of this study suggest that the home environment should be considered as a potential source of fungal exposure, and elevated home levels may predispose people with asthma to airways colonization.  相似文献   

4.
A study was undertaken to determine the effect of variations in temperature, relative humidity, occupancy density and location (indoor/outdoor) on the concentrations of viable airborne bacterial and fungal spores at an air-conditioned and a non air-conditioned food stall in Singapore. Typically, bioaerosols consisted of 50.5% bacteria and 49.5% fungi in the indoor environment. In contrast, for the outdoor environment, bacteria on an average only accounted for 20.6% of culturable airborne microorganisms whereas fungal concentrations were 79.4%. Results on bioaerosol size distributions revealed that 67% of indoor bacteria and 68% of outdoor bacteria, 85% of indoor fungi and 68% of outdoor fungi were associated with fine mode particulates (<3.3 μm). Occupant density was the key factor that affected indoor airborne bacteria concentrations while concentrations of outdoor airborne bacteria depended strongly on ambient temperature. Indoor fungal concentration was positively correlated to relative humidity whereas outdoor fungal concentration was positively correlated to relative humidity and negatively correlated to temperature. The study also compared the biological air quality between a non air-conditioned food stall (Stall A) and an air-conditioned food stall (Stall B). The dining area of the former had lower bacterial concentrations as compared to the latter, while fungal spore’s concentrations showed a reverse trend. The dominant airborne bacteria genera were Staphylococcus, Pseudomonas, Alcaligens, and Corynebacterium whereas Penicillium, Aspergillus and Cladosporium were the most common fungal genera and groups in both food stalls.  相似文献   

5.
The determinants of the temporal variability of indoor dust concentrations of semivolatile organic compounds (SVOCs) remain mostly unexplored. We examined temporal variability of dust concentrations and factors affecting dust concentrations for a wide range of SVOCs. We collected dust samples three times from 29 California homes during a period of 22 months and quantified concentrations of 47 SVOCs in 87 dust samples. We computed intraclass correlation coefficients (ICCs) using three samples collected within the same house. We calculated correlation coefficients (r) between two seasons with similar climate (spring and fall) and between two seasons with opposite climate (summer and winter). Among 26 compounds that were detected in more than 50% of the samples at all three visits, 20 compounds had ICCs above 0.50 and 6 compounds had ICCs below 0.50. For 19 out of 26 compounds, correlation coefficients between spring and fall (r = 0.48-0.98) were higher than those between summer and winter (r = 0.09-0.92), implying seasonal effects on dust concentrations. Our study showed that within-home temporal variability of dust concentrations was small (ICC > 0.50) for most SVOCs, but dust concentrations may vary over time for some SVOCs with seasonal variations in source rates, such as product use.  相似文献   

6.
Emissions from indoor biomass burning are a major public health concern in developing areas of the world. Less is known about indoor air quality, particularly airborne endotoxin, in homes burning biomass fuel in residential wood stoves in higher income countries. A filter‐based sampler was used to evaluate wintertime indoor coarse particulate matter (PM10‐2.5) and airborne endotoxin (EU/m3, EU/mg) concentrations in 50 homes using wood stoves as their primary source of heat in western Montana. We investigated number of residents, number of pets, dampness (humidity), and frequency of wood stove usage as potential predictors of indoor airborne endotoxin concentrations. Two 48‐h sampling events per home revealed a mean winter PM10‐2.5 concentration (± s.d.) of 12.9 (± 8.6) μg/m3, while PM2.5 concentrations averaged 32.3 (± 32.6) μg/m3. Endotoxin concentrations measured from PM10‐2.5 filter samples were 9.2 (± 12.4) EU/m3 and 1010 (± 1524) EU/mg. PM10‐2.5 and PM2.5 were significantly correlated in wood stove homes (r = 0.36, P < 0.05). The presence of pets in the homes was associated with PM10‐2.5 but not with endotoxin concentrations. Importantly, none of the other measured home characteristics was a strong predictor of airborne endotoxin, including frequency of residential wood stove usage.  相似文献   

7.
We aimed to characterize the presence of microbial secondary metabolites in homes and their association with moisture damage, mold, and asthma development. Living room floor dust was analyzed by LC‐MS/MS for 333 secondary metabolites from 93 homes of 1‐year‐old children. Moisture damage was present in 15 living rooms. At 6 years, 8 children had active and 15 lifetime doctor‐diagnosed asthma. The median number of different metabolites per house was 17 (range 8–29) and median sum load 65 (4–865) ng/m2. Overall 42 different metabolites were detected. The number of metabolites present tended to be higher in homes with mold odor or moisture damage. The higher sum loads and number of metabolites with loads over 10 ng/m2 were associated with lower prevalence of active asthma at 6 years (aOR 0.06 (95% CI <0.001–0.96) and 0.05 (<0.001–0.56), respectively). None of the individual metabolites, which presence tended (P < 0.2) to be increased by moisture damage or mold, were associated with increased risk of asthma. Microbial secondary metabolites are ubiquitously present in home floor dust. Moisture damage and mold tend to increase their numbers and amount. There was no evidence indicating that the secondary metabolites determined would explain the association between moisture damage, mold, and the development of asthma.  相似文献   

8.
Analysis of the dust from heating, ventilation, and air conditioning (HVAC) filters is a promising long‐term sampling method to characterize airborne particle‐bound contaminants. This filter forensics (FF) approach provides valuable insights about differences between buildings, but does not allow for an estimation of indoor concentrations. In this investigation, FF is extended to quantitative filter forensics (QFF) by using measurements of the volume of air that passes through the filter and the filter efficiency, to assess the integrated average airborne concentrations of total fungal and bacterial DNA, 36 fungal species, endotoxins, phthalates, and organophosphate esters (OPEs) based on dust extracted from HVAC filters. Filters were collected from 59 homes located in central Texas, USA, after 1 month of deployment in each summer and winter. Results showed considerable differences in the concentrations of airborne particle‐bound contaminants in studied homes. The airborne concentrations for most of the analytes are comparable with those reported in the literature. In this sample of homes, the HVAC characterization measurements varied much less between homes than the variation in the filter dust concentration of each analyte, suggesting that even in the absence of HVAC data, FF can provide insight about concentration differences for homes with similar HVAC systems.  相似文献   

9.
The risk of tobacco smoking and second‐hand smoke (SHS) exposure combined are the leading contributors to disease burden in high‐income countries. Recent studies and policies are focusing on reducing exposure to SHS in multiunit housing (MUH), especially public housing. We examined seasonal patterns of SHS levels within indoor common areas located on Boston Housing Authority (BHA) properties. We measured weekly integrated and continuous fine particulate matter (PM2.5) and passive airborne nicotine in six buildings of varying building and occupant characteristics in summer 2012 and winter 2013. The average weekly indoor PM2.5 concentration across all six developments was 9.2 μg/m3, higher during winter monitoring period (10.3 μg/m3) compared with summer (8.0 μg/m3). Airborne nicotine concentrations ranged from no detection to about 5000 ng/m3 (mean 311 ng/m3). Nicotine levels were significantly higher in the winter compared with summer (620 vs. 85 ng/m3; 95% CI: 72–998). Smoking‐related exposures within Boston public housing vary by season, building types, and resident smoking policy. Our results represent exposure disparities that may contribute to health disparities in low‐income communities and highlight the potential importance of efforts to mitigate SHS exposures during winter when outdoor–indoor exchange rates are low and smokers may tend to stay indoors. Our findings support the use of smoke‐free policy as an effective tool to eliminate SHS exposure and protect non‐smokers, especially residents of MUH.  相似文献   

10.
Variations in home characteristics, such as moisture and occupancy, affect indoor microbial ecology as well as human exposure to microorganisms. Our objective was to determine how indoor bacterial and fungal community structure and diversity are associated with the broader home environment and its occupants. Next‐generation DNA sequencing was used to describe fungal and bacterial communities in house dust sampled from 198 homes of asthmatic children in southern New England. Housing characteristics included number of people/children, level of urbanization, single/multifamily home, reported mold, reported water leaks, air conditioning (AC) use, and presence of pets. Both fungal and bacterial community structures were non‐random and demonstrated species segregation (C‐score, < 0.00001). Increased microbial richness was associated with the presence of pets, water leaks, longer AC use, suburban (vs. urban) homes, and dust composition measures (< 0.05). The most significant differences in community composition were observed for AC use and occupancy (people, children, and pets) characteristics. Occupant density measures were associated with beneficial bacterial taxa, including Lactobacillus johnsonii as measured by qPCR. A more complete knowledge of indoor microbial communities is useful for linking housing characteristics to human health outcomes. Microbial assemblies in house dust result, in part, from the building's physical and occupant characteristics.  相似文献   

11.
Airborne microorganisms in hospitals have been associated with several hospital-acquired infections (HAIs), and various measures of indoor air quality (IAQ) parameters such as temperature, relative humidity, carbon dioxide (CO2), particle mass concentration, and particle size have been linked to pathogen survival or mitigation of pathogen spread. To investigate whether there are quantitative relationships between the concentration of airborne microorganisms and the IAQ in the hospital environment. Web of Science, Scopus and PubMed databases were searched for studies reporting airborne microbial levels and any IAQ parameter(s) in hospital environments, from database inception to October 2020. Pooled effect estimates were determined via random-effects models. Seventeen of 654 studies were eligible for the meta-analysis. The concentration of airborne microbial measured as aerobic colony count (ACC) was significantly correlated with temperature (r = 0.25 [95% CI = 0.06–0.42], p = 0.01), CO2 concentration (r = 0.53 [95% CI = 0.40–0.64], p ˂ 0.001), particle mass concentration (≤5 µg/m3; r = 0.40 [95% CI = 0.04–0.66], p = 0.03), and particle size (≤5 and ˃5 µm), (r = 0.51 [95% CI = 0.12–0.77], p = 0.01 and r = 0.55 [95% CI = 0.20–0.78], p = 0.003), respectively, while not being significantly correlated with relative humidity or particulate matter of size >5 µm. Conversely, airborne total fungi (TF) were not significantly correlated with temperature, relative humidity, or CO2 level. However, there was a significant weak correlation between ACC and TF (r = 0.31 [95% CI = 0.07–0.52], p = 0.013). Although significant correlations exist between ACC and IAQ parameters, the relationship is not definitive; the IAQ parameters may affect the microorganisms but are not responsible for the presence of airborne microorganisms. Environmental parameters could be related to the generating source, survival, dispersion, and deposition rate of microorganisms. Future studies should record IAQ parameters and factors such as healthcare worker presence and the activities carried out such as cleaning, sanitizing, and disinfection protocols. Foot traffic would influence both the generation of microorganisms and their deposition rate onto surfaces in the hospital environment. These data would inform models to improve the understanding of the likely concentration of airborne microorganisms and provide an alternative approach for real-time monitoring of the healthcare environment.  相似文献   

12.
Baseline information on size‐resolved bacterial, fungal, and particulate matter (PM) indoor air concentrations and emission rates is presented for six school classrooms sampled in four countries. Human occupancy resulted in significantly elevated airborne bacterial (81 times on average), fungal (15 times), and PM mass (nine times) concentrations as compared to vacant conditions. Occupied indoor/outdoor (I/O) ratios consistently exceeded vacant I/O ratios. Regarding size distributions, average room‐occupied bacterial, fungal, and PM geometric mean particle sizes were similar to one another while geometric means estimated for bacteria, fungi, and PM mass during vacant sampling were consistently lower than when occupied. Occupancy also resulted in elevated indoor bacterial‐to‐PM mass‐based and number‐based ratios above corresponding outdoor levels. Mean emission rates due to human occupancy were 14 million cells/person/h for bacteria, 14 million spore equivalents/person/h for fungi, and 22 mg/person/h for PM mass. Across all locations, indoor emissions contributed 83 ± 27% (bacteria), 66 ± 19% (fungi), and 83 ± 24% (PM mass) of the average indoor air concentrations during occupied times.  相似文献   

13.
Exposure to bioaerosols poses important health effects on occupants. To elucidate seasonal and room variations of household airborne bacteria, this study investigated 30 residential homes during summer and winter throughout Nanjing, Southeast China, with a humid subtropical climate. Culturing and 16S rDNA sequencing methods were combined in this study. Results showed that the community structure and composition in the same season but different homes show similarity, however, they in the same home but in different seasons show a huge difference, with Sphingomonas (25.3%), Clostridium (14.8%), and Pseudomonas (7.6%) being the dominant bacteria in summer, and Pseudomonas (57.1%) was dominant bacteria in winter. Culturable concentrations of bacteria were also significantly higher in summer (854 ± 425 CFU/m3) than in winter (231 ± 175 CFU/m3), but difference by home or room was relatively minor. More than 80% of culturable bacteria (<4.7 μm) could penetrate into lower respiratory tract. The seasonal variations of bacterial community and concentrations were closely associated with seasonal variations of temperature, humidity, and PM2.5. Higher concentrations and larger sizes were observed in the bathroom and kitchen, typically with higher humidity than other rooms.  相似文献   

14.
Abstract Abstract Dust collected in New Orleans homes mold‐contaminated because of the flooding after hurricane Katrina was analyzed for molds and mycotoxins. The mycoflora was studied by cultivation and quantitative PCR for selected molds. The most commonly found mold taxa were Aspergillus, Cladosporium, and Penicillium. Verrucarol, a hydrolysis product of macrocyclic trichothecenes predominately produced by Stachybotrys spp. was identified in three dust samples by gas chromatography‐tandem mass spectrometry, and sterigmatocystin (produced by various Aspergillus spp.) was found in two samples by high pressure liquid chromatography‐tandem mass spectrometry. This is the first demonstration of mycotoxins in Katrina‐associated dust samples. The analytical methods used represent valuable tools in further studies on bioaerosol exposure and health risks.  相似文献   

15.
Indoor air pollution has been linked to adverse chronic obstructive pulmonary disease (COPD) health, but specific causative agents have not yet been identified. We evaluated the role of indoor endotoxin exposure upon respiratory health in former smokers with COPD. Eighty‐four adults with moderate to severe COPD were followed longitudinally and indoor air and dust samples collected at baseline, 3 and 6 months. Respiratory outcomes were repeatedly assessed at each time point. The associations between endotoxin exposure in air and settled dust and health outcomes were explored using generalizing estimating equations in multivariate models accounting for confounders. Dust endotoxin concentrations in the main living area were highest in spring and lowest in fall, while airborne endotoxins remained steady across seasons. Airborne and dust endotoxin concentrations were weakly correlated with one another (rs = +0.24, P = 0.005). Endotoxin concentrations were not significantly associated with respiratory symptoms, rescue medication use, quality of life, or severe exacerbations. In vitro whole‐blood assays of the pro‐inflammatory capacity of PM10 filters with and without endotoxin depletion demonstrated that the endotoxin component of indoor air pollution was not the primary trigger for interleukin‐1β release. Our findings support that endotoxin is not the major driver in the adverse effects of indoor PM upon COPD morbidity.  相似文献   

16.
Microbes in buildings have attracted extensive attention from both the research community and the general public due to their close relationship with human health. However, there still lacks comprehensive information on the indoor exposure level of microbes in China. This study systematically reviews exposure levels, the community structures, and the impact factors of airborne bacteria and fungi in residences, schools, and offices in China. We reviewed the major literature databases between 1980 and 2019 and selected 55 original studies based on a set of criteria. Results show that the concentration of indoor bacteria varies from 72.5 to 7500 CFU/m3, with a median value of 1000 CFU/m3, and the concentration of fungi varies from 12 to 9730 CFU/m3, with a median value of 526 CFU/m3. The concentration level of microbes varies in different climate zones, with higher bacterial concentrations in the severe cold zone, and higher fungal concentrations in the hot summer and warm winter zone. Among different buildings, classrooms have the highest average bacteria and fungi levels. This review reveals that a unified assessment system based on health effects is needed for evaluating the exposure levels of bacteria and fungi.  相似文献   

17.
This study examined: (i) biocontaminant levels in flooded homes of New Orleans two years after the flooding; (ii) seasonal changes in biocontaminant levels, and (iii) correlations between biocontaminant levels obtained by different environmental monitoring methods. Endotoxin, (1 → 3)-β-d-glucan, fungal spores, and dust mite allergens were measured in 35 homes during summer and winter. A combination of dust sampling, aerosolization-based microbial source assessment, and long-term inhalable bioaerosol sampling aided in understanding exposure matrices. On average, endotoxin found in the aerosolized fraction accounted for < 2% of that measured in the floor dust, suggesting that vacuuming could overestimate inhalation exposures. In contrast, the (1 → 3)-β-d-glucan levels in the floor dust and aerosolized fractions were mostly comparable, and 25% of the homes showed aerosolizable levels even higher than the dust-borne levels. The seasonal patterns for endotoxin in dust and the aerosolizable fraction were different from those found for (1 → 3)-β-d-glucan, reflecting the temperature and humidity effects on bacterial and fungal contamination. While the concentration of airborne endotoxin followed the same seasonal trend as endotoxin aerosolized from surfaces, no significant seasonal difference was identified for the concentrations of airborne (1 → 3)-β-d-glucan and fungal spores. This was attributed to the difference in the particle size; smaller endotoxin-containing particles can remain airborne for longer time than larger fungal spores or (1 → 3)-β-d-glucan-containing particles. It is also possible that fungal aerosolization in home environments did not reach its full potential. Detectable dust mite allergens were found only in dust samples, and more commonly in occupied homes. Levels of endotoxin, (1 → 3)-β-d-glucan, and fungi in air had decreased during the two-year period following the flooding as compared to immediate measurements; however, the dust-borne endotoxin and (1 → 3)-β-d-glucan levels remained elevated. No conclusive correlations were found between the three environmental monitoring methods. The findings support the use of multiple methods when assessing exposure to microbial contaminants.  相似文献   

18.
Fungi are known to occur ubiquitously in the environment. In the past years, the occurrence of filamentous fungi in the aquatic environment has been a subject of growing interest. This study describes the occurrence of various fungal genera in different drinking water sources being Penicillium and Trichoderma the most representative ones (30% and 17%, respectively). Also, 24 fungal species that have not been previously described in the aquatic environment are reported in this study, being once again the major species from the Penicillium genera. This study therefore contributes to the knowledge on the richness of fungi diversity in water. 68% of the described species were found to be able to grow at 30 °C but only Aspergillus fumigatus, Aspergillus viridinutans and Cunninghamella bertholletiae were able to grow at the higher temperature tested (42 °C). 66% of the species that were able to grow at 30 °C have spore sizes below 5 μm which enables them to cause breathing infections. These were therefore identified as potential pathogenic species.  相似文献   

19.
Fungal exposure inside homes has been associated with adverse respiratory symptoms in children and adults. While fungal assessment has traditionally relied upon questionnaires, fungal growth on culture plates and spore counts, new immunoassays for extracellular polysaccharides (EPS) and beta (1-->3)-glucans have enabled quantitation of fungal agents in house dust in a more timely and cost-effective manner, possibly providing a better measure of fungal exposure. We investigated associations among measurements of EPS, beta (1-->3)-glucans and culturable fungi obtained from 23 Dutch homes. From each home, dust samples were vacuumed from the living room floor twice during the Fall, Winter and Spring seasons for a total of six collections (every 6 weeks from October 1997 to May 1998). Samples were sieved and fine dust was analyzed for EPS from Aspergillus and Penicillium spp. combined, beta (1-->3)-glucans and culturable fungi. EPS was positively associated with glucan; an increase from the 25th to the 75th percentile of glucan concentration was associated with a 1.6-fold increase in EPS concentration (95% CI = 1.3 to 2.0; p < 0.01). The most significant variables associated with EPS and glucan concentrations were the surface type that was vacuumed and the concentration of total culturable fungi (in colony forming units (CFU)/g dust), with an increase in CFU/g from the 25th to the 75th percentile associated with a 1.3 (1.1-1.6)-fold increase in glucan and a 1.7 (1.3-2.2)-fold increase in EPS concentrations. In addition, the within-home variation of EPS levels were smaller than those between homes (25,646 U/g vs. 50,635 U/g), whereas the variation of glucan levels was similar within and between homes (1,300 vs. 1,205 micrograms/g). These positive associations suggest that house dust concentrations of beta (1-->3)-glucan, and particularly those of EPS, are good markers for the overall levels of fungal concentrations in floor dust which is a surrogate for estimating airborne fungal exposure.  相似文献   

20.
The presence of the fungal genus Chaetomium and its secondary metabolites in indoor environments is suspected to have a negative impact on human health and well‐being. About 200 metabolites have been currently described from Chaetomium spp., but only the bioactive compound group, chaetoglobosins, have been screened for and thus detected in buildings. In this study, we used a liquid chromatography high‐resolution mass spectrometry approach to screen both artificially and naturally infected building materials for all the Chaetomium metabolites described in the literature. Pure agar cultures were also investigated to establish differences between metabolite production in vitro and on building materials as well as in comparison with non‐indoor reference strains. On building materials, six different chaetoglobosins were detected in total concentrations of up to 950 mg/m2 from Chaetomium globosum along with three different chaetoviridins/chaetomugilins in concentrations up to 200 mg/m2. Indoor Chaetomium spp. preferred wood‐based materials over gypsum, both in terms of growth rate and metabolite production. Cochliodones were detected for the first time on all building materials infected by both C. globosum and Chaetomium elatum and are thus candidates as Chaetomium biomarkers. No sterigmatocystin was produced by Chaetomium spp. from indoor environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号