首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The contamination of indoor environments with chemical compounds released by materials and furniture, such as semi‐volatile organic compounds (SVOCs), is less documented in schools than in dwellings—yet children spend 16% of their time in schools, where they can also be exposed. This study is one of the first to describe the contamination of the air and dust of 90 classrooms from 30 nursery and primary schools by 55 SVOCs, including pesticides, phosphoric esters, musks, polycyclic aromatic hydrocarbons (PAHs), polychlorobiphenyls (PCBs), phthalates, and polybromodiphenylethers (PBDEs). Air samples were collected using an active sampling method, and dust samples were collected via two sampling methods (wiping and vacuum cleaning). In air, the highest concentrations (median >100 ng/m3) were measured for diisobutyl phthalate (DiBP), dibutyl phthalate (DBP), diethyl phthalate (DEP), bis(2‐ethylhexyl) phthalate (DEHP), and galaxolide. In dust, the highest concentrations (median >30 μg/g) were found for DEHP, diisononyl phthalate (DiNP), DiBP, and DBP. An attempt to compare two floor dust sampling methods using a single unit (ng/m²) was carried out. SVOC concentrations were higher in wiped dust, but frequencies of quantification were greater in vacuumed dust.  相似文献   

2.
Young children spend a substantial part of their waking time in preschools. It is therefore important to reduce the load of hazardous semivolatile organic compounds (SVOCs) in the preschools’ indoor environment. The presence and levels of five SVOC groups were evaluated (1) in a newly built preschool, (2) before and after renovation of a preschool, and (3) in a preschool where SVOC-containing articles were removed. The new building and the renovation were performed using construction materials that were approved with respect to content of restricted chemicals. SVOC substance groups were measured in indoor air and settled dust and included phthalates and alternative plasticizers, organophosphate esters (OPEs), brominated flame retardants, and bisphenols. The most abundant substance groups in both indoor air and dust were phthalates and alternative plasticizers and OPEs. SVOC concentrations were lower or of the same order of magnitude as those reported in comparable studies. The relative Cumulative Hazard Quotient (HQcum) was used to assess the effects of the different reduction measures on children's SVOC exposure from indoor air and dust in the preschools. HQcum values were low (1.0–6.1%) in all three preschools and decreased further after renovation and article substitution. The SVOCs concentrations decreased significantly more in the preschool renovated with the approved building materials than in the preschool where the SVOC-containing articles were removed.  相似文献   

3.
Retail stores contain a wide range of products that can emit a variety of indoor pollutants. Among these chemicals, phthalate esters and polybrominated diphenyl ethers (PBDEs) are two important categories of semi‐volatile organic compounds (SVOCs). Filters in heating, ventilation, and air‐conditioning (HVAC) system collect particles from large volumes of air and thus potentially provide spatially and temporally integrated SVOC concentrations. This study measured six phthalate and 14 PBDE compounds in HVAC filter dust in 14 retail stores in Texas and Pennsylvania, United States. Phthalates and PBDEs were widely found in the HVAC filter dust in retail environment, indicating that they are ubiquitous indoor pollutants. The potential co‐occurrence of phthalates and PBDEs was not strong, suggesting that their indoor sources are diverse. The levels of phthalates and PBDEs measured in HVAC filter dust are comparable to concentrations found in previous investigations of settled dust in residential buildings. Significant correlations between indoor air and filter dust concentrations were found for diethyl phthalate, di‐n‐butyl phthalate, and benzyl butyl phthalate. Reasonable agreement between measurements and an equilibrium model to describe SVOC partitioning between dust and gas‐phase is achieved.  相似文献   

4.
A mechanistic model that considers particle dynamics and their effects on surface emissions and sorptions was developed to predict the fate and transport of phthalates in indoor environments. A controlled case study was conducted in a test house to evaluate the model. The model‐predicted evolving concentrations of benzyl butyl phthalate in indoor air and settled dust and on interior surfaces are in good agreement with measurements. Sensitivity analysis was performed to quantify the effects of parameter uncertainties on model predictions. The model was then applied to a typical residential environment to investigate the fate of di‐2‐ethylhexyl phthalate (DEHP) and the factors that affect its transport. The predicted steady‐state DEHP concentrations were 0.14 μg/m3 in indoor air and ranged from 80 to 46 000 μg/g in settled dust on various surfaces, which are generally consistent with the measurements of previous studies in homes in different countries. An increase in the mass concentration of indoor particles may significantly enhance DEHP emission and its concentrations in air and on surfaces, whereas increasing ventilation has only a limited effect in reducing DEHP in indoor air. The influence of cleaning activities on reducing DEHP concentration in indoor air and on interior surfaces was quantified, and the results showed that DEHP exposure can be reduced by frequent and effective cleaning activities and the removal of existing sources, though it may take a relatively long period of time for the levels to drop significantly. Finally, the model was adjusted to identify the relative contributions of gaseous sorption and particulate‐bound deposition to the overall uptake of semi‐volatile organic compounds (SVOCs) by indoor surfaces as functions of time and the octanol‐air partition coefficient (Koa) of the chemical. Overall, the model clarifies the mechanisms that govern the emission of phthalates and the subsequent interactions among air, suspended particles, settled dust, and interior surfaces. This model can be easily extended to incorporate additional indoor source materials/products, sorption surfaces, particle sources, and room spaces. It can also be modified to predict the fate and transport of other SVOCs, such as phthalate‐alternative plasticizers, flame retardants, and biocides, and serves to improve our understanding of human exposure to SVOCs in indoor environments.  相似文献   

5.
Consumer products and building materials emit a number of semivolatile organic compounds (SVOCs) in the indoor environment. Because indoor SVOCs accumulate in dust, we explore the use of dust to determine source strength and report here on analysis of dust samples collected in 30 US homes for six phthalates, four personal care product ingredients, and five flame retardants. We then use a fugacity‐based indoor mass balance model to estimate the whole‐house emission rates of SVOCs that would account for the measured dust concentrations. Di‐2‐ethylhexyl phthalate (DEHP) and di‐iso‐nonyl phthalate (DiNP) were the most abundant compounds in these dust samples. On the other hand, the estimated emission rate of diethyl phthalate is the largest among phthalates, although its dust concentration is over two orders of magnitude smaller than DEHP and DiNP. The magnitude of the estimated emission rate that corresponds to the measured dust concentration is found to be inversely correlated with the vapor pressure of the compound, indicating that dust concentrations alone cannot be used to determine which compounds have the greatest emission rates. The combined dust‐assay modeling approach shows promise for estimating indoor emission rates for SVOCs.  相似文献   

6.
Phthalates are widely used in consumer products. Exposure to phthalates can lead to adverse health effects in humans, with early-life exposure being of particular concern. Phthalate exposure occurs mainly through ingestion, inhalation, and dermal absorption. However, our understanding of the relative importance of different exposure routes is incomplete. This study estimated the intake of five phthalates from the residential indoor environment for 455 Swedish pregnant women in the SELMA study using phthalate mass fraction in indoor dust and compares these to total daily phthalate intakes back-calculated from phthalate metabolite concentrations in the women's urine. Steady-state models were used to estimate indoor air phthalate concentrations from dust measurements. Intakes from residential dust and air made meaningful contributions to total daily intakes of more volatile di-ethyl phthalate (DEP), di-n-butyl phthalate (DnBP), and di-iso-butyl phthalate (DiBP) (11% of total DEP intake and 28% of total DnBP and DiBP intake combined). Dermal absorption from air was the dominant pathway contributing to the indoor environmental exposure. Residential exposure to less volatile phthalates made minor contributions to total intake. These results suggest that reducing the presence of low molecular weight phthalates in the residential indoor environment can meaningfully reduce phthalate intake among pregnant women.  相似文献   

7.
Abstract This paper critically examines indoor exposure to semivolatile organic compounds (SVOCs) via dermal pathways. First, it demonstrates that - in central tendency - an SVOC's abundance on indoor surfaces and in handwipes can be predicted reasonably well from gas-phase concentrations, assuming that thermodynamic equilibrium prevails. Then, equations are developed, based upon idealized mass-transport considerations, to estimate transdermal penetration of an SVOC either from its concentration in skin-surface lipids or its concentration in air. Kinetic constraints limit air-to-skin transport in the case of SVOCs that strongly sorb to skin-surface lipids. Air-to-skin transdermal uptake is estimated to be comparable to or larger than inhalation intake for many SVOCs of current or potential interest indoors, including butylated hydroxytoluene, chlordane, chlorpyrifos, diethyl phthalate, Galaxolide, geranyl acetone, nicotine (in free-base form), PCB28, PCB52, Phantolide, Texanol and Tonalide. Although air-to-skin transdermal uptake is anticipated to be slow for bisphenol A, we find that transdermal permeation may nevertheless be substantial following its transfer to skin via contact with contaminated surfaces. The paper concludes with explorations of the influence of particles and dust on dermal exposure, the role of clothing and bedding as transport vectors, and the potential significance of hair follicles as transport shunts through the epidermis. PRACTICAL IMPLICATIONS: Human exposure to indoor pollutants can occur through dietary and nondietary ingestion, inhalation, and dermal absorption. Many factors influence the relative importance of these pathways, including physical and chemical properties of the pollutants. This paper argues that exposure to indoor semivolatile organic compounds (SVOCs) through the dermal pathway has often been underestimated. Transdermal permeation of SVOCs can be substantially greater than is commonly assumed. Transport of SVOCs from the air to and through the skin is typically not taken into account in exposure assessments. Yet, for certain SVOCs, intake through skin is estimated to be substantially larger than intake through inhalation. Exposure scientists, risk assessors, and public health officials should be mindful of the dermal pathway when estimating exposures to indoor SVOCs. Also, they should recognize that health consequences vary with exposure pathway. For example, an SVOC that enters the blood through the skin does not encounter the same detoxifying enzymes that an ingested SVOC would experience in the stomach, intestines, and liver before it enters the blood.  相似文献   

8.
Building materials and human activities are important sources of contamination indoors, but little information is available regarding contamination during construction process which could persist during the whole life of buildings. In this study, six construction stages on two construction sites were investigated regarding the emissions of 43 volatile organic compounds (VOCs), 46 semi-volatile organic compounds (SVOCs), and the presence of 4 genera of mold. Results show that the future indoor air quality does not only depend on the emissions of each building product but that it is also closely related to the whole implementation process. Mold spore measurements can reach 1400 CFU/m3, which is particularly high compared with the concentrations usually measured in indoor environments. Relatively low concentrations of VOCs were observed, in relation to the use of low emissive materials. Among SVOCs analyzed, some phthalates, permethrin, and hydrocarbons were found in significant concentrations upon the delivery of building as well as triclosan, suspected to be endocrine disruptor, and yet prohibited in the treatment of materials and construction since 2014. As some regulations exist for VOC emissions, it is necessary to implement them for SVOCs due to their toxicity.  相似文献   

9.
Phthalic acid esters and phosphororganic compounds (POC) are generally known as semivolatile organic compounds (SVOCs) and are frequently utilized as plasticizers and flame retardants in commercial products. In the indoor environment, both compound groups are released from a number of sources under normal living conditions and accumulate in air and dust. Therefore, inhalation of air and ingestion of house dust have to be considered as important pathways for the assessment of exposure in living habitats. Especially in the case of very young children, the oral and dermal uptake from house dust might be of relevance for risk assessment. A critical evaluation of indoor exposure to phthalates and POC requires the determination of the target compounds in indoor air and house dust as well as emission studies. The latter are usually carried out under controlled conditions in emission test chambers or cells. Furthermore, chamber testing enables the determination of condensable compounds by fogging sampling. In the case of automobiles, specific scenarios have been developed to study material emissions on a test stand or to evaluate the exposure of users while the vehicle is driving. In this review, results from several studies are summarized and compared for seven phthalic esters and eight POC. The available data for room air and dust differ widely depending on investigated compound and compartment. Room air studies mostly include only a limited number of measurements, which makes a statistical evaluation difficult. The situation is much better for house dust measurements. However, the composition of house dust is very inhomogeneous and the result is strongly dependent on the particle size distribution used for analysis. Results of emission studies are presented for building products, electronic equipment, and automobiles. Daily rates for inhalation and dust ingestion of phthalic esters and POC were calculated from 95-percentiles or maximum values. A comparison of the data with results from human biomonitoring studies reveals that only a small portion of intake takes place via the air and dust paths.  相似文献   

10.
Hsu NY  Lee CC  Wang JY  Li YC  Chang HW  Chen CY  Bornehag CG  Wu PC  Sundell J  Su HJ 《Indoor air》2012,22(3):186-199
The associated risk of phthalate exposure, both parent compounds in the home and their metabolites in urine, to childhood allergic and respiratory morbidity, after adjusting for exposures of indoor pollutants, especially bioaerosols, was comprehensively assessed. Levels of five phthalates in settled dust from the homes of 101 children (3-9 years old) were measured, along with their corresponding urinary metabolites. Other environmental risk factors, including indoor CO2, PM2.5, formaldehyde, 1,3-β-D-glucan, endotoxin, allergen and fungal levels, were concomitantly examined. Subject's health status was verified by pediatricians, and parents recorded observed daily symptoms of their children for the week that the home investigation visit took place. Significantly increased level of benzylbutyl phthalate, in settled dust, was associated with test case subjects (allergic or asthmatic children). Higher levels of dibutyl phthalate and its metabolites, mono-n-butyl phthalate, and mono-2-ethylhexyl phthalate were found to be the potential risk factors for the health outcomes of interest. Similarly, indoor fungal exposure remained a significant risk factor, especially for reported respiratory symptoms. The relative contribution from exposure to phthalates and indoor biocontaminants in childhood allergic and respiratory morbidity is, for the first time, quantitatively assessed and characterized. PRACTICAL IMPLICATIONS: For asthmatic and allergic children living in subtropical and highly developed environments like homes in Taiwan, controlling environmental exposure of phthalates may be viewed as equally important as avoiding indoor microbial burdens, for the management of allergy-related diseases. It is also recognized that multidisciplinary efforts will be critical in realizing the true underlying mechanisms associated with these observations.  相似文献   

11.
The ongoing health debate about polymer plasticizers based on the esters of phthalic acid, especially di(2-ethylhexyl) phthalate (DEHP), has caused a trend towards using phthalates of lower volatility such as diisononyl phthalate (DINP) and towards other acid esters, such as adipates, terephthalates, citrates, etc. Probably the most important of these so-called “alternative” plasticizers is diisononyl cyclohexane-1,2-dicarboxylate (DINCH). In the indoor environment, the continuously growing market share of this compound since its launch in 2002 is inter alia apparent from the increasing concentration of DINCH in settled house dust. From the epidemiological point of view there is considerable interest in identifying how semi-volatile organic compounds (SVOCs) distribute in the indoor environment, especially in air, airborne particles and sedimented house dust. This, however, requires reliable experimental concentration data for the different media and good measurements or estimates of their physical and chemical properties. This paper reports on air concentrations for DINP, DINCH, diisobutyl phthalate (DIBP), diisobutyl adipate (DIBA), diisobutyl succinate (DIBS) and diisobutyl glutarate (DIBG) from emission studies in the Field and Laboratory Emission Cell (FLEC). For DINP and DINCH it took about 50 days to reach the steady-state value: for four months no decay in the concentration could be observed. Moreover, vapor pressures p0 and octanol-air partitioning coefficients KOA were obtained for 37 phthalate and non-phthalate plasticizers from two different algorithms: EPI Suite and SPARC. It is shown that calculated gas/particle partition coefficients Kp and fractions can widely differ due to the uncertainty in the predicted p0 and KOA values. For most of the investigated compounds reliable experimental vapor pressures are not available. Rough estimates can be obtained from the measured emission rate of the pure compound in a microchamber as is shown for di-n-butyl phthalate (DnBP), di(2-ethylhexyl) adipate(DEHA), tri(octyl) trimellitate (TOTM) and DEHP.  相似文献   

12.
In this study, the occurrence of persistent environmental contaminants room air samples from 59 apartments and 74 kindergartens in Berlin were tested in 2000 and 2001 for the presence of phthalates and musk fragrances (polycyclic musks in particular). These substances were also measured in household dust from 30 apartments. The aim of the study was to measure exposure levels in typical central borough apartments, kindergartens and estimate their effects on health. Of phthalates, dibutyl phthalate had the highest concentrations in room air, with median values of 1083 ng/m(3) in apartments and 1188 ng/m(3) in kindergartens. With around 80% of all values, the main phthalate in house dust was diethylhexyl phthalate, with median values of 703 mg/kg (range: 231-1763 mg/kg). No statistically significant correlation could be found between air and dust concentration. Musk compounds were detected in the indoor air of kindergartens with median values of 101 ng/m(3) [1,3,4,6,7,8-hexahydro-4,6,6,7,8,8- hexamethylcyclopenta-(g) 2-benzopyrane (HHCB)] and 44 ng/m(3) [7-acetyl-1,1,3,4,4,6-hexamethyl-tetraline (AHTN)] and maximum concentrations of up to 299 and 107 ng/m(3) respectively. In household dust HHCB and AHTN were detected in 63 and 83% of the samples with median values of 0.7 and 0.9 mg/kg (Maximum: 11.4 and 3.1 mg/kg) each. On comparing the above phthalate concentrations with presently acceptable tolerable daily intake values (TDI), we are talking about only a small average intake [di(2-ethylhexyl) phthalate and diethyl phthalate less than 1 and 8% of the TDI] by indoor air for children. The dominant intake path was the ingestion of foodstuffs. For certain subsets of the population, notably premature infants (through migration from soft polyvinyl chloride products), children and other patients undergoing medical treatment like dialysis, exchange transfusion, an important additional intake of phthalates must taken into account. PRACTICAL IMPLICATIONS: The phthalate and musk compounds load in a sample of apartments and kindergartens were low with a typical distribution pattern in air and household dust, but without a significant correlation between air and dust concentration. The largest source of general population exposure to phthalates is dietary. For certain subsets of the general population non-dietary ingestion (medical and occupational) is important.  相似文献   

13.
The determinants of the temporal variability of indoor dust concentrations of semivolatile organic compounds (SVOCs) remain mostly unexplored. We examined temporal variability of dust concentrations and factors affecting dust concentrations for a wide range of SVOCs. We collected dust samples three times from 29 California homes during a period of 22 months and quantified concentrations of 47 SVOCs in 87 dust samples. We computed intraclass correlation coefficients (ICCs) using three samples collected within the same house. We calculated correlation coefficients (r) between two seasons with similar climate (spring and fall) and between two seasons with opposite climate (summer and winter). Among 26 compounds that were detected in more than 50% of the samples at all three visits, 20 compounds had ICCs above 0.50 and 6 compounds had ICCs below 0.50. For 19 out of 26 compounds, correlation coefficients between spring and fall (r = 0.48-0.98) were higher than those between summer and winter (r = 0.09-0.92), implying seasonal effects on dust concentrations. Our study showed that within-home temporal variability of dust concentrations was small (ICC > 0.50) for most SVOCs, but dust concentrations may vary over time for some SVOCs with seasonal variations in source rates, such as product use.  相似文献   

14.
The investigation of settled dust is a proven and simple screening-method for considering indoor contamination for semivolatile compounds. Here we investigate the correlation of PCP concentrations in air and freshly settled dust from floors. Air and dust samples were taken from 75 rooms in 30 buildings with suspicion of an application of PCP-containing wood preservatives. Sampling was repeated four times within 18 months. PCP air concentrations were found in the range of <0.3-576 ng m-3 (mean value 25.3 ng m-3, median 2.5 ng m-3). PCP dust concentrations were found in the range of 0.083-79 microg g-1 (mean value 3.5 microg g-1, median 1.1 microg g-1. A weak highly significant correlation (P < 0.0001) with a correlation coefficient of R2 = 0.433, of the PCP concentration in dust with the PCP concentration in air, was observed. Measurement of PCP concentrations in dust, therefore, is a suitable screening method for the evaluation of indoor contamination with PCP. Due to the high dispersion of the data it is not possible to calculate PCP concentrations in air from concentrations in dust although a highly significant correlation of the PCP concentrations in air and dust was found.  相似文献   

15.
Semivolatile organic compounds (SVOCs) emitted from building materials, consumer products, and occupant activities alter the composition of air in residences where people spend most of their time. Exposures to specific SVOCs potentially pose risks to human health. However, little is known about the chemical complexity, total burden, and dynamic behavior of SVOCs in residential environments. Furthermore, little is known about the influence of human occupancy on the emissions and fates of SVOCs in residential air. Here, we present the first‐ever hourly measurements of airborne SVOCs in a residence during normal occupancy. We employ state‐of‐the‐art semivolatile thermal‐desorption aerosol gas chromatography (SV‐TAG). Indoor air is shown consistently to contain much higher levels of SVOCs than outdoors, in terms of both abundance and chemical complexity. Time‐series data are characterized by temperature‐dependent elevated background levels for a broad suite of chemicals, underlining the importance of continuous emissions from static indoor sources. Substantial increases in SVOC concentrations were associated with episodic occupant activities, especially cooking and cleaning. The number of occupants within the residence showed little influence on the total airborne SVOC concentration. Enhanced ventilation was effective in reducing SVOCs in indoor air, but only temporarily; SVOCs recovered to previous levels within hours.  相似文献   

16.
This paper reports the abundance in indoor air and dust of eleven organophosphate esters and six phthalate esters. Both groups of these semi-volatile compounds are widely incorporated as additives into plastic materials used in the indoor environment, thus contributing to indoor exposure to industrial chemicals. Thirty sampling sites representing three different indoor environments (private homes, day care centers, and workplaces) in the Stockholm area, Sweden, were selected to obtain representative concentration profiles in both ambient air and settled dust. Eight of the target organophosphate esters and all six phthalate esters were found in both air and dust samples at all locations. The phthalate esters were more abundant than the organophosphate esters, typically ten times higher total concentrations. Especially interesting were the high levels of tributoxyethyl phosphate in the day care centers, the relatively high levels of chlorinated organophosphate esters in the air of workplaces and the overall high levels of diethylhexyl phthalate in dust. The air concentration profiles of the phosphate esters differed significantly between the three indoor environments, whereas the concentration profiles of the phthalate esters as well as their total concentrations were similar. The correlation between concentrations found in air and in dust was found to be weak. PRACTICAL IMPLICATIONS: Organophosphate esters and phthalate esters are commonly used as additives in numerous building materials and consumer products. The use of these compounds is increasing, and phosphate and phthalate esters are to be regarded as ubiquitous contaminants in the indoor environment. These compounds comprise a number of different compounds that have been associated with biologic effects in animal studies as well as in humans. Thus, it is of concern to increase the knowledge about human exposure of these compounds because of their presence in indoor air. In this paper, thirty indoor environments have been surveyed with respect to seventeen of the most abundant of these compounds.  相似文献   

17.
Indoor dust samples cannot always be analyzed immediately after collection. However, little information is currently available on how storage conditions may affect measurements. This study was designed to determine how sample storage conditions may affect the concentration of semi‐volatile organic compounds (SVOCs) in the dust. A composite dust was prepared using a Standard Reference Material (SRM 2585) with real indoor dust samples. The composite dust was stored in various types of packaging, at different temperatures (?18°C, 5°C, 20°C, and 35°C), and in different light conditions. The concentration of SVOCs was measured after various storage durations. No effect on SVOC concentrations was observed for the composite dust stored in an amber glass vial at ?18°C for 36 months. At 5°C, 20°C, and 35°C, losses occurred for the more volatile compounds. The experimental storage conditions clearly showed that temperature and duration affected the concentrations of SVOCs in the composite dust. The type of packaging material (polyethylene zip bag or polyethylene garbage bag) did not seem to have a systematic effect on the preservation of SVOCs in the composite dust. Maximum storage duration times are proposed for each compound at various temperatures. For most compounds, samples can be stored for 2 months at 20°C. For samples that cannot be analyzed immediately, we recommend to store them in the dark at ?18°C to ensure a good recovery of all tested compounds.  相似文献   

18.
Considering that high school students spend a large proportion of their waking hours in the school environment, this could be an important location for exposure to indoor allergens. We have investigated the levels of mouse and cockroach allergens in the settled dust and air from 11 schools in a major northeastern US city. Settled dust samples were vacuumed from 87 classrooms, three times throughout the school year. Two separate air samples (flow = 2.5 lpm) were collected by 53 students over a 5-day period from both their school and their home. Mouse allergen (MUP) in the dust varied greatly between schools with geometric means ranging from 0.21 to 133 microg/g. Mouse allergen was detectable in 81% of the samples collected. Cockroach allergen (Bla g 2) ranged from below limit of detection (<0.003 microg/g) to 1.1 microg/g. Cockroach allergen was detected (>0.003 microg/g) in 71% of the dust samples. Bla g 2 was detected in 22% of airborne samples from the schools. By comparison, mouse allergen was only detected in 5%. These results indicate that the school may be an important location for exposure to allergens from mice and cockroaches and is an indoor environment that should be considered in an overall allergen intervention strategy. PRACTICAL IMPLICATIONS: To date, cockroach and mouse allergen intervention strategies have been mainly focused on the home environment. Considering that children spend a significant amount of time in schools, some studies have assessed cockroach allergen levels in schools. This study provides a clearer picture of the distribution and variability of not only cockroach allergen, but also mouse allergen in the school environment. In addition, this study describes limitations of personal air sampling in a student population. Our results suggest that although cockroach and mouse allergens are commonly recovered in classroom dust samples of inner city schools, cockroach allergens are recovered in the personal air samples with a greater frequency relative to mouse allergens.  相似文献   

19.
Smedje G  Norbäck D 《Indoor air》2001,11(2):127-133
In order to study the influence of furnishings and cleaning on the indoor air quality at school, 181 randomly chosen classrooms were investigated. The amounts of open shelves, textiles and other fittings were noted, data were gathered on cleaning routines, and a number of pollutants were measured in the classrooms. In classrooms with more fabrics there was more settled dust and the concentration of formaldehyde was higher. Classrooms with more open shelves had more formaldehyde, and more pet allergens in settled dust, and classrooms with a white board, instead of a chalk board, were less dusty. Classrooms mainly cleaned through wet mopping had more airborne viable bacteria but less settled dust than classrooms mainly cleaned by dry methods. In rooms where the desks and curtains were more often cleaned, the concentrations of cat and dog allergen in settled dust were lower. It is concluded that furnishings and textiles in the classroom act as significant reservoirs of irritants and allergens and have an impact on the indoor air quality at school.  相似文献   

20.
Indoor air pollution has been linked to adverse chronic obstructive pulmonary disease (COPD) health, but specific causative agents have not yet been identified. We evaluated the role of indoor endotoxin exposure upon respiratory health in former smokers with COPD. Eighty‐four adults with moderate to severe COPD were followed longitudinally and indoor air and dust samples collected at baseline, 3 and 6 months. Respiratory outcomes were repeatedly assessed at each time point. The associations between endotoxin exposure in air and settled dust and health outcomes were explored using generalizing estimating equations in multivariate models accounting for confounders. Dust endotoxin concentrations in the main living area were highest in spring and lowest in fall, while airborne endotoxins remained steady across seasons. Airborne and dust endotoxin concentrations were weakly correlated with one another (rs = +0.24, P = 0.005). Endotoxin concentrations were not significantly associated with respiratory symptoms, rescue medication use, quality of life, or severe exacerbations. In vitro whole‐blood assays of the pro‐inflammatory capacity of PM10 filters with and without endotoxin depletion demonstrated that the endotoxin component of indoor air pollution was not the primary trigger for interleukin‐1β release. Our findings support that endotoxin is not the major driver in the adverse effects of indoor PM upon COPD morbidity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号