首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
It is currently a common practice that a boiling water reactor (BWR) adopts hydrogen water chemistry (HWC) for mitigating corrosion in structural components in its primary coolant circuit. When the core flow rate (CFR) in a BWR is changed, the coolant residence time in the primary coolant circuit would be different. The concentrations of major redox species (i.e. hydrogen, oxygen, and hydrogen peroxide) in the coolant may accordingly vary due to different durations of radiolysis in the core and other near-core regions. A theoretical model by the name of DEMACE was used in the current study to investigate the impact of various CFRs (from 100% to 80.0%) on the effectiveness of HWC in a domestic BWR. Our analyses indicated that the HWC effectiveness at some locations could be downgraded due to a decrease in CFR. However, a lower CFR was instead beneficial to the corrosion mitigation efficiency of HWC at other locations. The impact of CFR on the HWC effectiveness could vary from location to location in a BWR and eventually from plant to plant.  相似文献   

2.
Many boiling water reactors (BWRs) have experienced extensive intergranular stress corrosion cracking (IGSCC) in their austenitic stainless steel reactor coolant system piping, resulting in serious adverse impacts on plant capacity factors, O&M costs, and personnel radiation exposures. A major research program to provide remedies for BWR pipe cracking was co-funded by EPRI, GE, and the BWR Owners Group for IGSCC Research between 1979 and 1988. Results from this program show that the likelihood of IGSCC depends on reactor water chemistry (particularly on the concentrations of ionic impurities and oxidizing radiolysis products) as well as on material condition and the level of tensile stress. Tests have demonstrated that the concentration of oxidizing radiolysis products in the recirculating reactor water of a BWR can be reduced substantially by injecting hydrogen into the feedwater. Recent plant data show that the use of hydrogen injection can reduce the rate of IGSCC to insignificant levels if the concentration of ionic impurities in the reactor water is kept sufficiently low. This approach to the control of BWR pipe cracking is called hydrogen water chemistry (HWC). This paper presents a review of the results of EPRI's HWC development program from 1980 to the present. In addition, plans for additional work to investigate the feasibility of adapting HWC to protect the BWR vessel and major internal components from potential stress corrosion cracking problems are summarized.  相似文献   

3.
Under neutron and gamma-ray irradiations, radiolytic species are generated directly in the crack tip, which causes higher oxidant concentrations and subsequently influences crack propagation rate.

A crevice radiolysis model was proposed to estimate the oxidant concentrations in the crack tip water under gamma-ray irradiation. Direct generation of radiolytic species in the crevice water, and their secondary generation and disappearance caused by their interaction with the crevice surface as well as species in the crevice water were included in the model. The diffusion of the radiolytic species through the narrow gap from the bulk water to the crack tip and vice versa were also considered.

Calculation results confirmed that the concentrations of H2O2, one of the most important oxidants in BWR environments, in both bulk water and crack tip water under irradiation (energy deposition rate: 0.1 W/cm) were high enough to show high local ECP in both regions under NWC, but were high in the bulk water and low in the crack tip water under HWC. A high H2 diffusion rate from the bulk to the crack tip enhanced the recombination reaction of H2O2 and H2.  相似文献   

4.
A theoretical model was adapted to evaluate the impact of power uprate on the water chemistry of a commercial boiling water reactor (BWR) in this work. In principle, the power density of a nuclear reactor upon a power uprate would change immediately, followed by water chemistry variations due to enhanced radiolysis of water in the core and near-core regions. It is currently a common practice for commercial BWRs to adopt hydrogen water chemistry (HWC) for corrosion mitigation. The optimal feedwater hydrogen concentration may be different after a power uprate is implemented in a BWR. A computer code DEMACE was used in the current study to investigate the impact of various power uprate levels on major radiolytic species concentrations and electrochemical corrosion potential (ECP) behavior of components in the primary coolant circuit of a domestic BWR-6 type reactor operating under either normal water chemistry or HWC. Our analyses indicated that under a constant core flow rate the chemical species concentrations and the ECP did not vary monotonously with increases in reactor power level at a fixed feedwater hydrogen concentration. In particular, the upper plenum and the upper downcomer regions exhibited uniquely higher ECPs at 108% and 115% power levels than at the other evaluated power levels.  相似文献   

5.
The stress corrosion cracking (SCC) of structural materials used in boiling water reactors has been studied at relatively low hydrogen peroxide (H2O2) concentrations, around lOppb, which was assumed to be representative of the corrosion environment formed in hydrogen water chemistry (HWC). The 1/4T compact tension specimen was used for measurement of crack growth rates (CGRs) of sensitized type 304 stainless steel in high temperature and high purity water. Crack length was monitored by a reversing direct current potential drop method. Since H2O2 is easily decomposed thermally, a polytetrafluoroethylene-lined autoclave was used to minimize its decomposition on the autoclave surface. The CGR in the H2O2 environment differed from that in the O2 environment even though the electrochemical corrosion potential (ECP) for both conditions was the same. The data implied that the ECP could not be used as a common environmental deterministic parameter for SCC behavior at higher potentials for different oxidant conditions. The corrosion current density was found to play an important role as an environmental index for SCC, which was given as just the current density at the ECP at a specific oxidant concentration. The CGRs were found to be written as CGR = (3.8±0.6)xl0-3 icor +(l-5±1.6) x 10-8mm/s using the calculated corrosion current density icorbelow 10-4 A-cm-2.  相似文献   

6.
As boiling water reactors (BWRs) age, intergranular stress corrosion cracking (IGSCC) of the structural materials in the reactor piping systems and vessel internals has become a major degradation problem. Several approaches to mitigating IGSCC in the structural components have been developed and investigated. Among them, the technique of inhibitive protective coatings is deemed the most promising one since it is expected to work even in the absence of the well-known hydrogen water chemistry technology.Following our earlier work on exploring the electrochemical characteristics of important oxidizing species on zirconium oxide (ZrO2) treated Type 304 stainless steels (SSs), we targeted on the characteristics of hydrogen peroxide, which is another strongly oxidizing species in the reactor coolant other than oxygen, in this study. Tests were conducted to determine electrochemical parameters such as electrochemical corrosion potential (ECP), corrosion current density, exchange current density and Tafel constant of the reduction reaction of hydrogen peroxide on 304 SS specimens before and after the ZrO2 treatment. The surface morphologies of the treated and untreated specimens were examined by scanning electron microscopy, energy dispersive X-ray spectroscopy, and laser Raman spectra. Furthermore, the corrosion mitigation efficiency of ZrO2 treatment was evaluated by electrochemical polarization tests in simulated BWR environments. Test results showed that there were no significant differences in ECP between the untreated and ZrO2 treated specimens in the test environments of various hydrogen peroxide concentrations. However, it was found via polarization analysis that the exchange current density of the reduction reaction on and the corrosion current density of the treated specimens were markedly lower than those on and of the untreated ones in the same environments. The ZrO2 treatment was able to deter the reduction rate of hydrogen peroxide on the Type 304 SS surface.  相似文献   

7.
The technique of noble metal treatment, such as noble metal coating (NMC) or noble metal chemical addition, accompanied by a low level hydrogen water chemistry, is being employed by a number of nuclear power plants around the world for mitigating intergranular stress corrosion cracking in the vessel internals of their boiling water reactors (BWRs). A computer model DEM ACE was expanded and employed to assess the effectiveness of NMC throughout the primary heat transport circuit (PHTC) of a BWR. The effectiveness of NMC was justified by the electrochemical corrosion potential (ECP) and crack growth rate (CGR) predictions. In calculating the ECP, enhancing factors for the exchange current densities of redox reactions available from recently published data, were employed. The Chinshan BWR was selected as a model reactor. According to the modeling results, it was found that the effectiveness of NMC in the PHTC of a BWR could vary from region to region at different feedwater hydrogen concentrations. For the selected BWR, NMC was predicted to be of little benefit when the feedwater hydrogen concentration reached 0.9 ppm or over. In particular, the NMC technique proved to be beneficial in reducing ECP and CGR along the PHTC even if the BWR was operated under normal water chemistry.  相似文献   

8.
Cathodic polarization curves of the O2 reduction reaction were measured by using electrodes made from typical structural materials of boiling water reactors (BWRs) to evaluate the effects of kind of material on the electrochemical corrosion potential (ECP) calculation. To estimate ECPs at any region in the BWRs on the basis of the BWR environmental conditions, anodic and cathodic polarization curves should be obtained in advance under relevant conditions. The concentration of oxidants such as O2 and H2O2 in coolant changes depending on the region in which they exist. As well, reduction reaction rates might differ depending on the kind of materials. In this work, the cathodic polarization curves of type 316L stainless steel (316L SS) and Alloy 182 were measured in high purity water at 553 K with different O2 concentrations and compared with those of type 304 SS (304 SS). The results showed that the cathodic polarization curves differed depending on the kind of materials at the activation-controlled region. But, the difference in the ECP vs. O2 concentration relationship was small when the ECPs were calculated by using both anodic and cathodic polarization curves measured on the objective material.  相似文献   

9.
In order to assess the influence of dissolved hydrogen on the intergranular stress corrosion cracking (IGSCC) characteristics of Type 304 stainless steels treated with inhibitive chemicals, electrochemical corrosion potential (ECP) measurements and slow strain rate tensile (SSRT) tests were conducted in high temperature pure water. A number of thermally sensitized specimens were prepared and then pre-oxidized in a 288°C pure water environment with the presence of 300ppb dissolved oxygen for 360h. Most of the specimens were then separately treated with various inhibitive chemicals including powdered zirconium oxide (ZrO2), powdered titanium oxide (TiO2), and zirconyl nitrate [ZrO(NO3)2] via hydrothermal deposition at 150°C. Test environments with a dissolved oxygen concentration of 300ppb and various dissolved hydrogen concentrations at 288°C were created. Test results showed that the ECPs of the treated specimens were lower than that of the untreated one no matter what the dissolved hydrogen concentration was. In addition, IGSCC was observed on all specimens (treated or untreated) in all tested environments. However, the untreated specimen exhibited lower elongation, shorter failure time, and more secondary cracks on the lateral surfaces. It was therefore suggested that inhibitive chemicals such as ZrO2, TiO2, and ZrO(NO2)2 did provide a certain degree of enhancement in improving the mechanical behavior of the treated specimens and in prolonging IGSCC initiation times.  相似文献   

10.
A system for the in situ monitoring of corrosion depth via electrical resistance measurements was applied to study the corrosion rate of type 316L stainless steel at 553 K in pure water. Corrosion depth was measured using a 50 μm diameter wire probe mounted axially in the tube. Measurements were in good agreement with literature data for both the hydrogen water chemistry (HWC) condition and the normal water chemistry (NWC) condition. Oxide film analyses by scanning electron microscopy and laser Raman spectroscopy on the wire probe and the tube showed no effects from shape of the test specimens or the application of electric current. Corrosion kinetics was evaluated by fitting equations to the measurements. Data for the HWC condition could be fitted by a two-step logarithmic–parabolic law. A single-step logarithmic law fitted data for the NWC condition. Changes in corrosion rate by the water chemistry changes were readily detected with the technique. Corrosion depth change could be observed for the water chemistry change from the NWC condition to the HWC condition with electrochemical corrosion potential (ECP) of ?0.56 V vs. standard hydrogen electrode, which is lower than the ECP that the phase of iron oxide changes from α-Fe2O3 to Fe3O4.  相似文献   

11.
For enhancing the effectiveness of hydrogen water chemistry (HWC) in boiling water reactors (BWRs) in the aspects of lower hydrogen consumption and of a more effective reduction in electrochemical corrosion potential (ECP), the technique of inhibitive protective coating on structural materials was brought into consideration. The application of inhibitive treatment is aimed at deterring the reduction reactions of oxidizing species occurring on metal surfaces and the oxidation reaction of metals. In the current study, electrochemical polarization analyses at 288°C were conducted to characterize the electrochemical properties of ZrO2 treated and untreated 304 stainless steel specimens in pure water with dissolved oxygen or hydrogen. The polarization results showed that the treated specimens exhibited lower corrosion potentials, corrosion current densities, exchange current densities, and cathodic current densities than the untreated one in high temperature pure water with dissolved oxygen. For the environment with dissolved hydrogen only, reductions in anodic current density and exchange current density were observed, indicating that the ZrO2 treatment also deterred the oxidation reaction of hydrogen. However, in comparison with the data obtained, the ZrO2 treatment seemed to be relatively more effective in inhibiting the oxygen reduction reaction than inhibiting the hydrogen oxidation reaction. One additional beneficial outcome was that the anodic current density of the metal was also decreased, leading to a much lower overall corrosion current density of the ZrO2 treated specimen.  相似文献   

12.
A test loop has been installed in Ringhals 1 BWR, including facilities for Constant Elongation Rate Testing (CERT) and Electrochemical Potential (ECP) measurements in primary reactor water at reactor operation temperature. The loop is designed as to minimize transport time for reactor water from the reactor pressure vessel to the specimens being tested. Thus the testing environment is representative of the primary piping systems of BWRs, also with regard to short-lived constituents like hydrogen peroxide.The test program, which is in progress, has covered seven tests during start-up conditions or during power operation with presently current reactor water chemistry. In this presentation only CERT testing results on heavily sensitized austenitic chromium—nickel stainless steel are presented, although many other materials have been tested.Results show sensitized austenitic stainless steel is more prone to intergranular stress corrosion cracking (IGSCC) in actual than in simulated BWR environment and that start-up environment is chemically more aggressive than power operation environment. Reproducibility of the CERT technique as used is excellent.  相似文献   

13.
A calculation model on intergranular stress corrosion cracking (IGSCC) initiation time of materials used in boiling water reactors (BWRs) has been developed to evaluate effectiveness of water chemistry control for mitigation of the IGSCC. The model was composed of four terms which determine passive film break time: (1) a chemical term based on electrochemical corrosion potential (ECP) and impurity concentration; (2) a mechanical term based on strain rate; (3) a material term based on sensitization; and (4) an irradiation term based on acceleration of corrosion by γ-rays and neutron irradiation. The contribution of the chemical term in the passive film break was calculated based on a deterministic local corrosion model. Then, the local corrosion model was modified by adding mechanical acceleration of the film rupture to treat the IGSCC phenomenon. The model could reproduce the behavioral tendency seen in the slow strain rate tensile test on high carbon contents with sensitization heat treatment (for example, 620°C × 24 h). Under BWR operating conditions, IGSCC initiation time could be extended by a factor of 5 by lowering the electric conductivity from 1.0 to 0.06 μS/cm. If the ECP was reduced below the critical potential by a mitigation method, the IGSCC initiation time was predicted to become sufficiently long for pipings and components.  相似文献   

14.
The difference in electrochemical corrosion potential of stainless steel exposed to high temperature pure water containing hydrogen peroxide (H2O2) and oxygen (O2)is caused by differences in chemical form of oxide films. In order to identify differences in oxide film structures on stainless steel after exposure to H2O2 and O2 environments, characteristics of the oxide films have been examined by multilateral surface analyses, e.g., X-ray diffraction (XRD), Rutherford back scattering spectroscopy (RBS), secondary ion mass spectroscopy (SIMS) and X-ray photoelectron spectroscopy (XPS). Preliminary characterization results of oxide films confirmed that the oxide film formed under the H2O2 environment consists mainly of hematite (α-Fe2O2), while that under the O2 environment consists of magnetite (Fe3O4). Furthermore oxidation at the very surface of the film is much more enhanced under the H2O2 environment than that under the O2 environment. It was speculated that metal hydroxide plays an important role in oxidation of stainless steel in the presence of H2O2. The difference in electric resistance of oxide film causes the difference in anodic polarization properties. It is recommended that several anodic polarization curves for specimens with differently oxidized films should be prepared to calculate ECP based on the Evans diagram.  相似文献   

15.
Japanese LWRs have experienced several troubles caused by corrosions of structural materials in the past ca. 20 years of their operational history, among which are increase in the occupational radiation exposures, intergranular stress corrosion cracking (IGSCC) of stainless steel piping in BWR, and steam generator corrosion problems in PWR. These problems arised partly from the improper operation of water chemistry control of reactor coolant systems. Consequently, it has been realized that water chemistry control is one of the most important factors to attain high availability and reliability of LWR, and extensive researches and developments have been conducted in Japan to achieve the optimum water chemistry control, which include the basic laboratory experiments, analyses of plant operational data, loop tests in operating plants and computer code developments. As a result of the continuing efforts, the Japanese LWR plants have currently attained a very high performance in their operation with high availability and low occupational radiation exposures. A brief review is given here on the R & D of water chemistry in Japan  相似文献   

16.
The effects of hydrogen addition to the feedwater on the corrosion and hydrogen uptake performance of Zircaloy-2 fuel cladding tubes, a water rod tube and spacer materials irradiated for four cycles in a BWR were evaluated. The uniform oxide behaviors of the cladding tubes, water rod and spacer materials were not affected by hydrogen water chemistry (HWC) condition. The hydrogen uptake and pickup fractions of the water rod and spacer materials were similar to those of water rods and spacer materials under normal water chemistry (NWC) conditions. As for the fuel rods, in spite of comparably heavy crud deposition, their hydrogen uptake and pickup fractions were clearly lower than the values under NWC conditions. Overall, the results indicated that HWC had no adverse effects on fuel performance.  相似文献   

17.
A number of boiling water reactor (BWR) plants worldwide are currently operating under hydrogen water chemistry (HWC). In some reactors, when switching from normal water chemistry (NWC) to HWC, an increase in the recirculation piping dose rates has been observed. Understanding the key factors which affect the dose rate increase is the subject of our current investigation. Laboratory experiments have been conducted under control chemistry conditions to examine the rates of 60Co deposition and the characteristic of oxide films formed on stainless steel surfaces. The activity buildup data obtained from two operating BWRs are carefully reviewed and discussed in this paper. Based on both laboratory and reactor data, a plausible mechanism of enhanced activity buildup under HWC conditions is hypothesized.  相似文献   

18.
Hydrogen and hydrazine co-injection into a boiling water reactor was considered as a new mitigation method of stress corrosion cracking (SCC). In this method, some amount of ammonia will be formed by the decomposition of hydrazine. The effect of ammonia on SCC susceptibility was studied over a wide range of electrochemical corrosion potentials (ECPs) in 288_C water by conducting slow strain rate technique SCC experiments (SSRTs). ECP was changed from _0:6V versus the standard hydrogen electrode (V(SHE)) to 0.1 V(SHE) by controlling dissolved oxygen concentration. Ammonia concentration was controlled to have values of 100 and 530 ppb. Similarly, sulfuric acid was injected to confirm the difference in the effect of injected chemical compounds on SCC susceptibility. The intergranular stress corrosion cracking (IGSCC) fraction, which was used as the index of SCC susceptibility, decreased with decreasing ECP for the case of no chemical injection. Sulfuric acid enhanced the IGSCC fraction. These data were in good agreement with literature data. On the other hand, ammonia at less than 530 ppb did not affect IGSCC fraction. It is expected that 51–280 ppb hydrazine and 0–53 ppb hydrogen will be injected into reactor water to mitigate SCC in BWRs. In the bottom region of the reactor pressure vessel, ECP and ammonia concentration will be _0:1 V(SHE) and 15–60 ppb, respectively. Under these conditions, ammonia did not affect SCC susceptibility. So SCC susceptibility will be mitigated by decreasing the ECP using hydrazine and hydrogen co-injection.  相似文献   

19.
The Lawrence Livermore National Laboratory (LLNL) has estimated the probability of double-ended guillotine break (DEGB) in the reactor coolant piping of Mark I boiling water reactor (BWR) plants. Two causes of pipe break are considered: crack growth at welded joints and the seismically-induced failure of component supports. For the former a probabilistic fracture mechanics model is used, for the latter a probabilistic support reliability model. This paper describes a probabilistic model developed to account for effects of intergranular stress corrosion cracking (IGSCC). The IGSCC model, based on experimental and field data compiled from several sources, correlates times to crack initiation and crack growth rates for Types 304 and 316NG stainless steel against material-specific ‘damage parameters’ which consilidate the separate effects of coolant environment (temperature, dissolved oxygen content, level of impurities), stress (including residual stress), and degree of sensitization. Application of this model to actual BWR recirculation piping shows that IGSCC clearly dominates the probability of failure in 304SS piping, mainly due to cracks that initiate within a few years after plant operation has begun. Replacing Type 304 piping with 316NG reduces failure probabilities by several orders of magnitude.  相似文献   

20.
《核技术(英文版)》2016,(1):141-148
Under normal water chemistry conditions, the oxygen and hydrogen peroxide produced by water radiolysis in the coolant of boiling water reactors(BWRs) can lead to intergranular stress corrosion cracking in the constituent materials of plant components. This fact has led to the wide-scale adoption of hydrogen water chemistry(HWC) in the nuclear industry to counteract these effects.This study seeks to characterize the metallic composition and the surface properties of the constituent materials of plant components in order to determine their effects on the accumulation of chalk river unidentified deposits(crud) on fuel rods in the BWR Unit-1 of the Kuosheng Nuclear Power Plant in Taiwan. Inductively coupled plasma-atomic emission spectroscopy was used to calculate the concentrations of surface crud and gamma spectrometry was used to determine the radioactivity of the corrosion products, as well as their axial distribution across the surface of the fuel rods. X-ray diffraction analysis and scanning electron microscopy/energy-dispersive X-ray spectroscopy were used to identify the crystalline phase and morphology of the crud as irregular shapes and flakes. The amount of crud deposited during the fourth fuel cycle exceeded that of the third fuel cycle due to extended burn-up time. Our analytical results indicate that the implementation of HWC had no significant effect on the characteristics of subsequent crud.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号