首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
This work conducts compression tests and finite element analyses for steel dual-gusset-plate connections used for buckling-restrained braced frames (BRBFs). Compared to a single-gusset-plate connection, dual gusset plates sandwiching a BRB core reduce gusset plate size, eliminate the need for splice plates, and enhance connection stability under compression. The experimental program investigated ultimate compression load by testing ten large dual-gusset-plate connections. Out-of-plane deformation of the gusset plate in the test resembled that of a buckled gusset plate with low bending rigidity provided by the BRB end. The general-purpose nonlinear finite element analysis program ABAQUS was applied for correlation analysis. A parametric study of the dual-gusset-plate connection was performed to study the effects of plate size, presence of centerline stiffeners, and beam and column boundaries on ultimate compression load. The ultimate compression load of the dual-gusset-plate connection could not be predicted based on the AISC-LRFD approach due to beam flange out-of-plane deformation. The ultimate compression load of the dual-gusset-plate connection was reasonably predicted using a column strip length from the Whitmore section to the workpoint of the beam and column centerlines and a buckling coefficient of K = 2.  相似文献   

2.
This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with carbon fibre reinforced polymers (CFRP). The next four specimens had steel fibres added to the concrete. The final four specimens were reinforced with steel fibres and wrapped with CFRP. From each group of specimens, one specimen was tested as a column under a concentric load, the second specimen was tested as a column under 25 mm eccentricity, the third specimen was tested as a column under 50 mm eccentricity, and the final specimen was tested as a beam under four point loading regime. The experimental programme proved that the introduction of fibres as well as wrapping the specimens with FRP improve the properties of concrete, especially its ductility.  相似文献   

3.
Steel fiber-added reinforced concrete (SFRC) applications have become widespread in areas such as higher upper layers, tunnel shells, concrete sewer pipes, and slabs of large industrial buildings. Usage of SFRC in load-carrying members of buildings having conventional reinforced concrete (RC) frames is also gaining popularity recently because of its positive contribution to both energy absorption capacity and concrete strength.This paper presents experimental and finite element analysis of three SFRC beams. For this purpose, three SFRC beams with 250 × 350 × 2000 mm dimensions are produced using a concrete class of C20 with 30 kg/m3 dosage of steel fibers and steel class S420 with shear stirrups. SFRC beams are subjected to bending by a four-point loading setup in certified beam-loading frame, exactly after having been moist-cured for 28 days. The tests are with control of loads. The beams are loaded until they are broken and the loadings are stopped when the tensile steel bars are broken into two pieces. Applied loads and mid-section deflections are carefully recorded at every 5 kN load increment from the beginning till the ultimate failure.One of the SFRC beams modeled by using nonlinear material properties adopted from experimental study is analyzed till the ultimate failure cracks by ANSYS. Eight-noded solid brick elements are used to model the concrete. Internal reinforcement is modeled by using 3D spar elements. A quarter of the full beam is taken into account in the modeling process.The results obtained from the finite element and experimental analyses are compared to each other. It is seen from the results that the finite element failure behavior indicates a good agreement with the experimental failure behavior.  相似文献   

4.
The paper presents results of an investigation conducted to study the impact resistance of steel fibre reinforced concrete containing fibres of mixed aspect ratio. An experimental investigation was planned in which 108 plain concrete and SFRC beam specimens of size 100 × 100 × 500 mm were tested under impact loading. The specimen incorporated three different volume fractions i.e. 1.0%, 1.5% and 2.0% of corrugated steel fibres. Each volume fraction incorporated mixed steel fibres of size 0.6 × 2.0 × 25 mm and 0.6 × 2.0 × 50 mm in different proportions. The drop weight type impact tests were conducted on the test specimens and the number of blows of the hammer required to induce first visible crack and ultimate failure of the specimen were recorded. The results are presented in terms of number of blows required as well as impact energy at first crack and ultimate failure. It has been observed that concrete containing 100% long fibres at 2.0% volume fraction gave the best performance under impact loading.  相似文献   

5.
An experimental program was conducted to investigate the effect of stresses and cracks, caused by alkali-silica reaction (ASR) and freezing and thawing (F/T), on bond between reinforcing steel and concrete. Pullout test cylinders, reinforced with 18 mm steel bars, were used to evaluate bond behavior. Concrete prisms (50 × 50 × 300 mm) were also cast to evaluate expansion and reduction in ultrasonic velocity due to ASR and F/T cycles, respectively. Specimens were cured for 40 days before being either immersed in sodium hydroxide solution of 0.5 normality in order to accelerate ASR, or subjected to different cycles of F/T. Bond behavior, expansion, and ultrasonic pulse velocity tests were carried out as ASR progressed or under F/T cycles.The progress of ASR resulted in significant losses in critical bond stress and ultimate bond strength capacity reaching as high as 44% and 24%, respectively, accompanied by a significant increase in free-end slip at failure. The loss in bond due to ASR was higher for specimens prepared using concrete with lower concrete strength and higher percentage of reactive aggregate. F/T action caused a significant reduction in critical bond stress and ultimate bond strength that reached as high as 100% and 55%, respectively, and an increase in free-end slip at failure. Neither ASR nor F/T cycles affected trends in the behavior of bond stress versus free end slip curves.  相似文献   

6.
Glass fibre-reinforced polymer (GFRP) tubes are compared to steel spiral reinforcement in circular concrete members with longitudinal reinforcement and prestressing, using six beam tests. Two 324 mm diameter and 4.2 m long prestressed specimens were tested in bending. Four 219 mm diameter reinforced specimens were also tested, including two 2.43 m long beams tested in bending and two 0.6 m long beams tested in shear. In each set, one specimen was essentially a concrete-filled GFRP tube, while the other control specimen included steel spiral reinforcement of comparable hoop stiffness to that of GFRP tube. The strength of control specimens was governed by crushing and spalling of concrete cover. Unlike spiral reinforcement, GFRP tubes confined larger concrete areas and also contributed as longitudinal reinforcement, leading to increases in flexural and shear strengths, up to 113% and 69%, respectively.  相似文献   

7.
8.
The utilisation of waste materials in the construction industry is an effective way to sanitise the environment and reduces the cost of construction. In this research, palm oil clinker (POC) aggregates was used to fully replace normal aggregates to produce structural lightweight concrete. This concrete was used in the construction of composite slabs with profiled steel sheet. A total of eight full scale composite slabs, six palm oil clinker concrete (POCC) slabs and two conventional concrete slabs were constructed and tested in accordance to Eurocode 4: Part 1.1 and BS 5950: Part 4: 1994. Two shear spans were used, 450 mm for short shear span and 900 mm for long shear span. The structural behaviour of the slabs was investigated and compared. The horizontal shear-bond strength between the concrete and the steel was determined according to two methods; mk and partial shear connection methods. Test results show that the structural behaviour and the horizontal shear-bond strength of the POCC slabs are nearly similar to the conventional concrete slabs. The mechanical interlock (m) and the friction (k) between the steel and the concrete are 117.67 N/mm2 and 0.0973 N/mm2, respectively and the design horizontal shear-bond strength using m-k and PSC methods is 0.248 N/mm2 and 0.215 N/mm2, respectively. The difference between the two methods is 13.3%. POCC is therefore suitable to be used for structural applications with a reduction in weight of 18.3% compared to conventional concrete composite slabs.  相似文献   

9.
The mechanical and electrical properties of graphite and carbon fiber modified asphalt concrete were measured in this paper through the indirect tensile test. The experimental results indicate that the mechanical properties of asphalt mixture are influenced by the addition of conductive component like graphite and carbon fiber, When the graphite content increased from 0 to 22 vol.%, Marshall stability decreased from 12.8 kN to 9.43 kN and residual stability from 91.1% to 87.2%. Rutting dynamic stability decreased from 3318 times/mm to 2619 times/mm. After adding the carbon fiber, when the carbon fiber content increased from 0 to 2 vol.%, their Marshall stability and residual stability increased from 12.8 kN to 13.5 kN and residual stability from 91.1% to 92.7%. Rutting dynamic stability increased from 3318 times/mm to 3403 times/mm. When modified through combination effect of graphite and carbon fiber mixed fillers, the mechanical performance and electrical property were improved greatly, their Marshall stability and residual stability has increased from 9.43 kN to 12.1 kN and residual stability from 87.2% to 89.2%. Rutting dynamic stability increased from 2619 times/mm to 3292 times/mm. Furthermore, the resilient modulus is influenced by the addition of graphite, the value of resilient modulus is as much as that of the original, it is 90% when graphite is 30 vol.% and is 70% when graphite is 45 vol.%. The electrical resistance increases reversibly with increasing tensile strain either under dynamic indirect tensile testing or static indirect tensile testing, graphite and carbon fiber modified asphalt concretes are effective for the self-monitoring of strain. It is foreseen that the strain–stress self monitoring is valuable for weighing, traffic monitoring, border monitoring and structural vibration control.  相似文献   

10.
Corrosion of steel bars embedded in concrete having compressive strengths of 20, 30 and 46 MPa was investigated. Reinforced concrete specimens were immersed in a 3% NaCl solution by weight for 1, 7 and 15 days. In order to accelerate the chemical reactions, an external current of 0.4 A was applied using portable power supply. Corrosion rate was measured by retrieving electrochemical information of polarization technique. Pull-out tests of reinforced concrete specimens were then conducted to assess the corroded steel/concrete bond characteristics.Experimental results showed that corrosion rate of steel bars and bond strength between corroded steel/concrete were dependent on concrete strength and accelerated corrosion period. As concrete strength increased from 20 to 46 MPa, corrosion rate of embedded steel decreased. First day of corrosion acceleration caused a slight increase in steel/concrete bond strength, whereas sever corrosion after 7 and 15 days of corrosion acceleration significantly reduced steel/concrete bond strength. Visual and metallographic observation of steel bars removed from concrete samples after testing revealed that the severity of corrosion reactions and reduction of steel bar diameter increased as the corrosion acceleration period increased. Presence of localized corrosion pits as well as severe corrosion grooves of steel bars was confirmed after 7 and 15 days of corrosion acceleration, respectively.  相似文献   

11.
This paper presents an experimental study investigating the behavior of FRP-reinforced concrete bridge deck slabs under concentrated loads. A total of eight full-scale deck slabs measuring 3000-mm long by 2500-mm wide were constructed. The test parameters were: (i) slab thickness (200, 175 and 150 mm); (ii) concrete compressive strength (35–65 MPa); (iii) bottom transverse reinforcement ratio (1.2–0.35%); and (iv) type of reinforcement (GFRP, CFRP, and steel). The slabs were supported on two parallel steel girders and were tested up to failure under monotonic single concentrated load acting on the center of each slab over a contact area of 600 × 250 mm to simulate the footprint of sustained truck wheel load (87.5 kN CL-625 truck). All deck slabs failed in punching shear. The punching capacity of the tested deck slabs ranged from 1.74 to 3.52 times the factored load (Pf) specified by the Canadian Highway Bridge Design Code (CHBDC) CAN/CSA S6-06. Besides, the ACI 440.1R-06 punching strength equation greatly underestimated the capacity of the tested slabs with an average experimental-to-predicted punching capacity ratio (Vexp/Vpred) of 3.17.  相似文献   

12.
The effectiveness of strengthening reinforced concrete (RC) beams with prestressed near-surface mounted (NSM) carbon fiber reinforced polymer (CFRP) rods was investigated. Four RC beams (254 mm deep by 152 mm wide by 3500 mm long) were tested under monotonic loading. One beam was kept un-strengthened as a control beam. One beam was strengthened with a non-prestressed NSM CFRP rod. Two beams were strengthened with prestressed NSM CFRP rods stressed to 40% and 60% of the rod’s ultimate strength. The test results showed that strengthening with non-prestressed NSM CFRP rod enhanced the flexural response of the beam compared to that of the control beam. A remarkable improvement in the response was obtained when the RC beams were strengthened with prestressed (40% and 60%) NSM CFRP rods. An increase up to 90% in the yield load and a 79% in the ultimate load compared to those of the control beam were obtained. An analytical model was developed using sectional analysis method to predict the flexural response of RC beams strengthened with prestressed NSM CFRP rods. The proposed model showed excellent agreement with the experimental results.  相似文献   

13.
The experimental studies on the behaviour of recycled aggregate concrete-filled steel tube (RACFST) stub columns after exposed to high temperatures are reported in this paper. Forty specimens, including 32 RACFST stub columns and 8 normal concrete-filled steel tube (CFST) stub columns as reference, were tested, and the failure pattern, load versus strain relation and ultimate strength of the specimens were presented and analysed. Five types of concrete were produced: one reference concrete with natural aggregates, two concrete mixes with recycled coarse aggregate (RCA) replacement ratios of 50% and 100%, and two concrete mixes with recycled fine aggregate (RFA) replacement ratios of 50% and 100%. The specimens were exposed to 300 °C, 600 °C and 800 °C for 3 h. The test results showed that, due to the existence of the recycled aggregates, the post-fire performance of RACFST stub columns was lower than the corresponding normal CFST specimens under the same maximum temperature suffered, and the RACFST specimens with RCA had a better behaviour than those with RFA under the same recycled aggregate replacement ratio.  相似文献   

14.
This paper presents experimental investigations on the thermal and mechanical behavior of composite floors subjected to ISO standard fire. Four 5.2 m×3.7 m composite slabs are tested with different combinations of the presence of one unprotected secondary beam, direction of ribs, and location of the reinforcement. The experimental results show that the highest temperature in the reinforcements occurs during the cooling phase (30–50 °C increment after 10-min cooling). The temperature at the unexposed side of the slabs is below 100 °C up to 100-min heating, compared to the predicted fire resistance close to 90 mins from EC4. For the slabs without secondary beams, the cracks first occur around the boundaries of the slab, while for the slabs supported by one unprotected secondary beam, concrete cracks first occur on the top of the slab above the beam due to the negative bending moment, and later on develop around boundaries. Debonding is observed between the steel deck and concrete slab. The secondary beam significantly impacts the deformation shape of tested slabs. Although a large deflection, 1/20 of the span length, is reached in the tests, the composite slabs can still provide sufficient load-bearing capacity due to membrane action. The occurrence of tensile membrane action is confirmed by the measured tensile stress in the reinforcement and compressive stress in the concrete. A comparison between measured and predicted fire resistance of the slabs indicates that EC4 calculations might be used for the composite slabs beyond the specified geometry limit, and the prediction is conservative.  相似文献   

15.
The objective of this research is to investigate the seismic performance of the composite joint consisting of square concrete filled thin-walled steel tubular (CFTST) column and steel beam with end plate and blind bolts. The cold-formed square tube in each CFTST column connection was fabricated by seam welding together four pieces of lipped angle with nominal wall thickness 1.5 mm or 3 mm. Four exterior joint specimens were tested under axially compressive load on the top of the columns and cyclic loads on the beam tip. The experimental parameters in the study were the thickness of the steel tube and the type of end plate. The seismic response of the blind bolted moment joints to CFTST columns was analyzed and evaluated in terms of the hysteretic behavior, failure modes, stiffness and strength degradation, ductility, and energy dissipation capacities of the joints. To improve the tension behavior of the blind bolted moment connections to the thin tube wall, the anchorage action of reinforcing rebar welded to the bolts with concrete-filled steel tubes was also investigated to consider the effect of cyclic loading. The experimental and analytical results indicated that when the end plate thickness is not less than 3 mm, the flush or extended end plate joints to CFTST columns exhibited large hysteretic loops and excellent seismic performance, such as ductility and energy dissipation capacity. The proposed innovative blind bolted joint was verified as a reliable and effective solution applied in mid- and low-rise buildings through properly design and detailing.  相似文献   

16.
In this paper monotonic and cyclic finite element (FE) analyses are presented for the development of an I-beam-to-CHS column steel moment joint for seismic actions. The development process for the final joint details includes: (1) eliminating two identified structural deficiencies of distortion in column web panel and strain concentrations in the external diaphragms; (2) creating a multi-fuse energy dissipation mechanism; (3) devising a joint to delay onset of beam yielding. Two external diaphragm collar plates are welded to the circumference of the CHS column for connection to beam flanges. Various collar ring widths are examined for these horizontal diaphragms and a width (based on achieving full strength of the beam flanges) is found to produce an acceptable web panel performance. Different types of stiffener geometries in the connection region are then trialed to eliminate strain concentrations in the diaphragms. Two pairs of triangular diaphragm stiffeners are found to provide the desired performance. In order to produce a multi-fuse energy dissipation mechanism, tapered cover plates (TCPs) equipped with vertical stiffeners (VSs) are integrated into the joint. Oversized web holes of 4–10 mm are required to enable inelastic deformation for an overall joint rotation of 60–100 mrad, without undesirable web distortion. Further FE analyses are used to design the TCPs and VSs so they can be replaceable link post-seismic actions. For the final joint detailing it is shown that 6 mm oversized holes for the TCPs will delay the occurrence of yielding in the beam until the joint rotation is 70 mrad.  相似文献   

17.
Corrosion phenomena and related effects, such as size reduction in both rebars and strands, bond decay at steel–concrete interface, and cracking in the surrounding concrete, are particularly critical in prestressed-concrete members, not only for safety reasons, but also for their huge potential socio-economic effects. As a matter of fact, this technique has been used for the last 50 years in the majority of viaducts and bridges built in many countries like Italy.In order to evaluate the influence of the corrosion on prestressed pretensioned beams, a number of tests has been carried out in the Laboratory of the University of Rome “Tor Vergata”.Nine prestressed beams (section size 200 × 300; total length 3000 mm; clear span 2700 mm) were first subjected to artificial corrosion, to obtain different damage levels, and then were tested in four-point bending.The results clearly show the sizable effects that corrosion has on the ultimate capacity (that is significantly reduced), on the failure mode and on the structural response, that turns from ductile to brittle.  相似文献   

18.
In general, the addition of fibers in concrete mix significantly improves many of the engineering properties of concrete. On the other hand, steel fibers reduce the workability of concrete. This paper presents the effect of steel-fiber length (aspect ratio) and content on bleeding of steel fiber reinforced concrete (SFRC). Two different steel fiber types (both is hooked-end) were used at a ratio of 0% (control), 0.3%, 0.64%, 1% and 1.3% by volume. Slump, Ve-Be test, air content and unit weight were determined experimentally. Specimens were poured in the standard moulds and the bleeding water content was measured 30 min, 60 min, 90 min, 120 min, 150 min and 180 min after starting the test. The results indicated that the workability of concrete significantly reduced as the fiber dosage rate increases. This was assessed through standard slump test and Ve-Be consistometer test. The bleeding water content was increased by increase of the fiber volume fraction and fiber aspect ratio according to experimental results. Also, a bleeding coefficient value for SFRC made with and without steel fiber was proposed as a result of this study.  相似文献   

19.
This paper presents the results of an experimental study conducted to characterize the structural behaviour of reinforced concrete beams corroded whilst subjected to constant sustained service loads. Corrosion of tensile steel bars was induced by an accelerated corrosion process using a 5% solution of NaCl and a constant impressed current. Four RC beams were tested, each with a width of 153 mm, a depth of 254 mm and a length of 3000 mm. Beams were tested whilst under a load equivalent to 1%, 8% and 12% of the ultimate load. Longitudinal tensile and compressive strains were monitored during the corrosion process and used to determine the variation of the depth of the neutral axis, the curvature and the second moment of area of beams with the time of electrolysis. The results indicate that the longitudinal strains, the depth of the neutral axis and the curvature of beams depend on both the level of corrosion and the applied service load whilst the second moment of area is mostly influenced by the level of corrosion.  相似文献   

20.
The strengthening of reinforced concrete structures with externally bonded fibre reinforced polymer (FRP) laminates has shown excellent performance and, as a result, this technology is rapidly replacing steel plate bonding techniques. The numerous studies that have been carried out to date on FRP-strengthened concrete elements have mainly focussed on the static and short-term responses; very little work has been done regarding the long-term performance. This paper addresses this issue, and presents results from a series of experiments on the time-dependent behaviour of carbon FRP-strengthened concrete beams. Twenty-six reinforced concrete beams with dimensions 100 × 150 × 1800 mm, with and without bonded CFRP laminates, were investigated for their creep behaviour. Different reinforcement ratios were used to evaluate the contribution of the external reinforcement on the creep resistance of the beams. High levels of sustained load were used in order to determine the maximum sustained load that can be applied without any risk of creep failure. The applied sustained loads varied from 59% to 78% of the ultimate static capacities of the un-strengthened beams. For most of the long-term tests, the applied sustained loads were higher than the service loads. This was done to account for the fact that strengthening is typically required when a structure is expected to carry increased service loads. The main parameters of this study were (i) the level of sustained load and (ii) the strengthening scheme. The results confirm that FRP strengthening is effective for increasing the ultimate capacities of the beams; however, there is virtually no improvement in performance with regard to the long-term deflections.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号