首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Friction and Wear of Polyamide 66 With Different Weight Average Molar Mass   总被引:1,自引:0,他引:1  
The friction and wear of monolithic polyamide 66 (PA66) and a PA66 composite reinforced with short glass fibers were examined using a block-on-ring friction tester with particular focus on the effect of weight average molar mass (M w) of PA66. The amount of glass fibers in the composite and the molecular weight strongly affected the friction level and wear rate because it altered the shear strength and adhesion of PA66. In the case of the glass fiber-reinforced PA66 composites, the improvement of the tribological property was attributed to the increased softening temperature of the composite and reduced material transfer to the counter surface. From this study, the optimum composite having the improved wear resistance with the low friction level was achieved with the lower M w PA66 containing 40 vol.% glass fibers.  相似文献   

2.
Jianliang Li  Dangsheng Xiong 《Wear》2009,266(1-2):360-367
Nickel-based graphite-containing composites were prepared by powder metallurgy method. Their mechanical properties at room temperature and friction and wear properties from room temperature to 600 °C were investigated by a pin-on-disk tribometer with alumina, silicon nitride and nickel-based alloy as counterfaces. The effects of graphite addition amount, temperature, load, sliding speed and counterface materials on the tribological properties were discussed. The micro-structure and worn surface morphologies were analyzed by scanning electron microscope (SEM) attached with energy dispersive spectroscopy (EDS). The results show that the composites are mainly consisted of nickel-based solid solution, free graphite and carbide formed during hot pressing. The friction and wear properties of composites are all improved by adding 6–12 wt.% graphite while the anti-bending and tensile strength as well as hardness decrease after adding graphite. The friction coefficients from room temperature to 600 °C decrease with the increase of load, sliding speed while the wear rates increase with the increasing temperature, sliding speed. The lower friction coefficients and wear rates are obtained when the composite rubs against nickel-based alloy containing molybdenum disulfide. Friction coefficients of graphite-containing composites from room temperature to 600 °C are about 0.4 while wear rates are in the magnitude of 10?5 mm3/(N m). At high temperature, the graphite is not effective in lubrication due to the oxidation and the shield of ‘glaze’ layer formed by compacting back-transferred wear particles. EDS analysis of worn surface shows that the oxides of nickel and molybdenum play the main role of lubrication instead of graphite at the temperature above 400 °C.  相似文献   

3.
The application spectrum of natural fiber reinforced polymer composites is growing rapidly in various engineering fields. The present study explores the possibilities of reinforcing thermoplastic bio-polymer with locally available inexpensive plant fibers for developing a new tribo-material. Three different types of natural fibers (nettle, grewia optiva and sisal) were incorporated into PLA polymer to develop laminated composites using a hot compression technique. TGA analysis was carried out to investigate the thermal stability of developed composites. Wear and frictional characteristics of developed composites were investigated under dry contact condition at different operating parameters, such as applied load (10–30 N), sliding speed (1–3 m/s) and sliding distance (1000–3000 m). The experimental results indicate that incorporation of natural fiber mats into PLA matrix significantly improves the wear behavior of neat polymer. There was 10–44% reduction in friction coefficient and more than 70% reduction in specific wear rate of developed composites as compared to neat PLA. The worn surface morphology was studied using scanning electron microscope (SEM) to analyze the wear mechanism in different types of developed composites.  相似文献   

4.
《Wear》2002,252(11-12):1007-1015
Boriding of the surface of a tool steel using boron powder and the plasma transferred arc process was investigated. It was shown that this method is an easy and effective technique in producing uniform alloyed layers with a thickness of about 1.5 mm and a hardness between 1000 and 1300 HV.The microstructure of the borided surfaces consists of primary Fe2B-type borides and a eutectic mixture of borides and martensite. Some cracks are observed in the eutectic regions but they do not seem to critically affect the behaviour of the coatings in sliding wear.The wear rate of pin on disc tests is primarily affected by the applied load and it lies between 10−5 mm3/m for low loads and 10−2 mm3/m for high loads. Two distinct regimes of mild and severe wear are obtained separated by a critical load. Mild wear is due to the load supporting effect of borides and severe wear is due to their breakage above a critical load. The wear rate is not significantly affected by the sliding velocity and is consistent with the friction coefficient.The friction coefficient varies from 0.13 to 0.23 and depends strongly on the oxidation status of the wear track. The sliding velocity affects the sliding distance where the coefficient of friction reaches equilibrium.  相似文献   

5.
Four kinds of paper-based friction materials reinforced with carbon fibers of 100, 400, 600 and 800 μm were prepared by paper-making processes. Experimental results showed that the friction materials became porous with fiber length increasing. The friction torque curves were flat except the sample with 100 μm fibers. The wear rate of the sample with 100 μm fibers was only 1.40×10−5 mm3/J. Tiny debris and fine scratches formed in the worn surface were the reason for excellent wear resistance of friction pairs with 100 μm fibers. The friction pairs with 400, 600 and 800 μm fibers showed typically abrasive wear and fatigue wear.  相似文献   

6.
《Wear》2007,262(1-2):220-224
PEEK is a high strength engineering thermoplastic that suffers from a high friction coefficient and a friction induced wear mode. Past studies with 10 μm PEEK and PTFE powders resulted in composite solid lubricant that (at the optimal composition) had a wear rate of k = 2 × 10−9 mm3/Nm with a friction coefficient of μ = 0.12. A compositional grading of PEEK and PTFE is implemented in this study to create a bulk composite with the functional requirements of component strength, stiffness and wear resistance while providing solid lubrication at the sliding interface. The tribological performances of three functionally graded PEEK components were evaluated on linear reciprocating, rotating pin-on-disk and thrust washer tribometers. Wear rates comparable to samples of the bulk solid lubricant and comparable or improved frictional performance were achieved by compositionally grading the near surface region of PEEK components.  相似文献   

7.
A composite with continuous carbon fibers (CF) (80% by vol.) and high performance thermoplastic polyetherimide (PEI) matrix was developed and evaluated for various mechanical properties as a function of fiber orientation angle (0°, 30°, 45°, 60° and 90°). It was observed that Young's modulus, Poisson's ratio, toughness and % strain decreased with the increase of fiber orientation angle with respect to loading direction. In-plane shear modulus was highest for fibers with 45°. Overall, unidirectional (UD) CF reinforcement enhanced all strength properties of PEI significantly. Composites with fibers in 0° (parallel to loading direction) proved best in almost all the properties. Tribological evaluation in abrasive wear mode under different loads and fiber orientations indicated that coefficient of friction (μ) and specific wear rate (K0) decreased with load, in general. Comparatively low specific wear rate (K0), (in the order of 0.7 1×10?9 m3/Nm) was observed for 0° fiber orientation, while fibers in 90° showed almost three times higher wear rate. Overall fiber reinforcement in 0° orientations proved beneficial from both strength and tribological performance point of view. SEM proved useful to correlate wear rate with surface topography.  相似文献   

8.
T. Hermann  T.A. Blanchet  N.F. Panayotou 《Wear》2010,268(1-2):126-132
Self-mated wear and friction of Alloy 600 superalloy was studied in a water-submersed ring-on-rod configuration, loading the side of a 6.35 mm diameter rod across the flat surface of a rotating annular ring of 100 mm outer diameter and 70 mm inner diameter producing two sliding contacts along the ring. Tests were conducted at sliding speeds of 0.178 and 0.330 m/s for sliding distances of 100 m. Normal loads of 51 and 204 N were applied, and initial Ra surface roughnesses of the rings along the sliding direction were either smooth (~0.2 μm) or rough (~7.5 μm). Increased initial ring roughness caused a ~20-fold increase in rod wear at the lighter load, whereas at the heavier load increased initial roughness only caused a ~4-fold increase in wear. At lower initial ring roughness the 4-fold decrease in normal load caused a large (one order-of-magnitude) decrease in rod wear, whereas for rings of higher initial roughness the 4-fold decrease in normal load caused only minor (2-fold or less) decreases in rod wear. Wear during this 100 m sliding distance only experienced a minor effect from the 1.8-fold change in sliding speed, as did friction. In all cases friction coefficient rapidly settled into the range 0.6–0.7, except in the cases of lower load on rings of lower initial roughness where friction coefficient remained above 1 for most of this sliding duration. At this lower load the initial ~0.2 μm rod roughnesses increased to nearly 0.8 μm by the 100 m sliding distance, whereas at the higher load this same sliding distance resulted in roughnesses returning near to the initial 0.2 μm. It was hypothesized more highly loaded cases also went through initial roughening prior to smoothening back to 0.2 μm roughness within the 100 m sliding distance, and given additional sliding the more lightly loaded cases would also experience subsequent smoothening. Increasing sliding distance to 400 m, roughnesses indicated a smoothening back to 0.2 μm level during those lightly loaded tests, with friction coefficient correspondingly dropping from 1 into the 0.6–0.7 range observed in all other cases. Extended sliding to 400 m at light loading against rings of lower initial roughness also allowed a rod wear rate which increased with increased sliding distance to be observed, approaching the same rate observed against initially rough rings within the 100 m sliding distance.  相似文献   

9.
《Wear》2002,252(11-12):979-984
In the present study, wear behaviour of woven 300 and 500 glass fabrics and aramid fibre-reinforced composite materials are experimentally investigated for 500 and 710 rpm speeds and at two different loads of 500 and 1000 g using a block-on-shaft wear tester. The wear in the experiments was determined as weight loss. The weight losses were measured after different sliding distance conditions. The worn surfaces were also examined by scanning electron microscope (SEM). As a result of this study, it is shown that the applied load on the specimens has more effect on the wear than the speed. Also the weight loss in the woven 500 glass fabric reinforced is more than that in the woven 300 glass fabric-reinforced composite. The weight loss of aramid fibre-reinforced composite is quite low compared with woven glass fabric-reinforced composites.  相似文献   

10.
In bolted joints, a large part of the load is transferred by friction. The objective of this investigation is to measure the coefficient of friction for carbon fiber epoxy matrix composite, HTA-6376, in contact with aluminum, 3637-77, in reciprocal sliding. During testing, the coefficient of friction increased initially with number of cycles and after reaching a maximum, slowly decreased. The initial coefficient of friction is approximately 0.23 and the peak coefficient of friction after wear in is approximately 0.68. The coefficient of friction is independent of normal load. During wear, cracks are formed at the fiber–matrix interface, which causes the matrix layer on the original composite surface to break off in pieces. It also causes single fibers or groups of fibers to be broken off and removed from the surface. Pieces of carbon fiber caused depressions in the aluminum surface. The wear debris is reattached to the composite surface but not to the aluminum surface.  相似文献   

11.
《Wear》2007,262(7-8):876-882
Transfer films of PTFE/bronze composites with 5–30% volume content of bronze were prepared using a RFT friction and wear tester on surface of AISI-1045 steel bar by different sliding time (5–60 min). Tribological properties of these transfer films were studied using a DFPM reciprocating tribometer in a point contacting configuration under normal loads of 0.5, 1.0, 2.0 and 3.0 N. Thickness and surface morphology of the transfer films were investigated. It was found thickness of the transfer films slightly increased along with the increase of bronze content of corresponding composites. Increased sliding time of transfer film preparation is helpful to form transfer film with better ductibility and continuity, but sliding time almost has no effect on tribological properties of the transfer film. Higher bronze content in the composite improved tribological properties of the corresponding transfer film, i.e., reduced friction coefficient and prolonged wear life. All these transfer films are sensitive to load change. Their wear life becomes shorter along with the increase of load. SEM image of the worn surface show fatigue wear and adhesion wear have happened on the transfer film during the friction process. The author believe bronze in the transfer film effectively partaked in shear force applied on the transfer film and its good ductibility helped to improve tribological properties of the transfer films.  相似文献   

12.
Hierarchical porous PEEK self-lubricating composites were prepared by mold-leaching and vacuum melting process under high temperature. The tribological behaviors were investigated for the porous PEEK composite and the porous composite after incorporating micro-porogen (NaCl) and mesoporous titanium oxide whiskers. If only micro-porogen was incorporated, the lowest steady state specific wear rate was observed for PEEK composites filled with 30% NaCl. Based on this porous PEEK composite, the effects of mesoporous titanium oxide whiskers and non-perforated titanium oxide whiskers on the friction and wear properties of PEEK composites were studied. Results showed that nano-micro porous PEEK composites with 30 wt% micro-porogen and 5 wt% mesoporous titanium oxide whiskers reached the lowest friction coefficient and specific wear rate, which were recorded as 0.0194 and 2.135×10–16 m3/Nm under the load of 200 N. Compared with 15 wt% carbon fiber-reinforced PEEK composite which is widely used in industry, the wear resistance of the designed hierarchical porous PEEK composite increased by 41 times, showing outstanding wear resistance.  相似文献   

13.
The friction behavior of CuO/yttria-stabilized tetragonal zirconia (3Y-TZP) composite in dry sliding against alumina at room temperature has been investigated. The results show that an alumina counterface has a crucial role on the frictional behavior when sliding against CuO/3Y-TZP composite in comparison with other counter materials. Pure 3Y-TZP shows high friction and wear under the same conditions. It is found that the friction reduction behavior is dependent on the sliding test conditions such as load and humidity. A thin aluminum-rich layer less than 200 nm thick on the contact surface during the low friction situation has been found by various analyzing techniques including interference microscopy, micro-Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microcopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The induced change of contact conditions and interfacial chemical reaction between CuO and alumina to form the phase CuAlO2 increase the wear of alumina and accelerates the formation of an aluminum-rich surface layer. The presence of such a layer in the contact is beneficial for reducing friction. After a certain sliding distance, the coefficient of friction shifts from a low value to a high value due to a change in the dominating wear mechanism. This transition is shown to be caused by a different composition and thickness of the interfacial layer.  相似文献   

14.
Nagaraj Chelliah  Satish V. Kailas 《Wear》2009,266(7-8):704-712
The present work provides an insight into the dry sliding wear behavior of titanium based on synergy between tribo-oxidation and strain rate response. Pin-on-disc tribometer was used to characterize the friction and wear behavior of titanium pin in sliding contact with polycrystalline alumina disk under ambient and vacuum condition. The sliding speed was varied from 0.01 to 1.4 ms?1, normal load was varied from 15.3 to 76 N and with a sliding distance of 1500 m. It was seen that dry sliding wear behavior of titanium was governed by combination of tribo-oxidation and strain rate response in near surface region of titanium. Strain rate response of titanium was recorded by conducting uni-axial compression tests at constant true strain rate of 100 s?1 in the temperature range from 298 to 873 K. Coefficient of friction and wear rate were reduced with increased sliding speed from 0.01 to 1.0 ms?1. This is attributed to the formation of in situ self lubricating oxide film (TiO) and reduction in the intensity of adiabatic shear band cracking in the near surface region. This trend was confirmed by performing series of dry sliding tests under vacuum condition of 2 × 10?4 Torr. Characterization tools such as optical microscopy, scanning electron microscopy, and X-ray diffractometer provided evidence of such processes. These experimental findings can be applied to enhance the dry sliding wear behavior of titanium with proper choice of operating conditions such as sliding speed, normal load, and environment.  相似文献   

15.
《Wear》2006,260(1-2):123-127
In this research, the wear of electroless Ni–P and Ni–P–B4C composite coatings was reviewed. Auto catalytic reduction of Ni in nickel sulfate and sodium hypophosphate bath including suspended B4C particles with different concentration was used to create composite coatings with 12, 18, 25 and 33 vol.% of B4C particles. Coatings 35 μm thick were heat treated at 400 °C for one hour in an argon atmosphere and the wear resistance and friction coefficient of heat-treated samples were determined by block-on-ring tests. All wear tests were carried out at 24 °C, 35% moisture, 0.164 m/s sliding speed and about 1000 m sliding distance. Graphs show that an electroless Ni–P–B4C composite coating with 25 vol.% of B4C had the best wear resistance against a CK45 steel counterface.  相似文献   

16.
Nam P. Suh 《Wear》1979,53(1):129-141
The friction and wear behavior of composites (i.e. uniaxially oriented graphite fiber-epoxy, Kevlar fiber-epoxy and biaxially oriented glass fiber-MoS2-polytetrafluoroethylene (PTFE)) was investigated as a function of varying fiber orientations with respect to the sliding direction. In graphite fiber-epoxy composites, both wear and friction coefficients were minimum when the orientation of the fibers was normal to the sliding surface. In Kevlar-epoxy composites when the fibers were oriented normal to the surface and the sliding direction, the wear rate was also minimum but the friction coefficient was the highest. In glass fiber-MoS2-PTFE composites wear was minimum when the largest fraction of fibers was oriented normal to the sliding surface.  相似文献   

17.
High speed dry friction experiments of graphite fiber/Cu-Sn matrix composites against steel were conducted at sliding velocities up to 235 m s?1. The composite samples were prepared by the method of liquid metal infiltration. It has been determined that the friction coefficient and the wear rate depend on the amount of tin in the matrix, orientation of fibers relative to the sliding surface, the sliding velocity, the graphite grain size and the degree of liquid metal infiltration within the fibers. The increase in tin content leads to a decrease in both friction and wear due to an increase in matrix hardness. Specimens tested with the fibers oriented perpendicular to the sliding surface exhibit better frictional behavior than those with fibers parallel to the sliding surface. Both friction coefficient and wear rate reach a minimum value at a velocity between about 120 and 180 m s?1. Large graphite grain size and poor liquid metal infiltration within the fibers have a detrimental effect on wear.  相似文献   

18.
《Wear》2006,260(9-10):933-941
Sliding friction and wear characteristics of three-dimensional (3-D) braided carbon fabric reinforced epoxy resin (C3D/EP) composites were investigated. Tests were performed on a MM200 tester under normal loads of 50, 150, and 250 N and velocities of 0.42 and 0.84 m/s. A quenched medium carbon steel with a hardness of HRC 52 was used as the counterpart material. The specific wear rate and the coefficient of friction were examined as a function of testing conditions (load, velocity, and sliding distance) and material parameters (fiber volume fraction and fiber–matrix bonding). The results showed that the coefficient of friction and the specific wear rate changed considerably during the running-in period and reached stable values at the steady wear stage. Fiber volume fraction and testing conditions (load and velocity) affected the wear more significantly than the friction. It was also found that fiber–matrix bonding had an impact on the friction and wear of the 3-D composites. Furthermore, the specific wear rate decreased with the increase in the product of load and velocity. Worn surfaces and debris were observed by scanning electron microscope (SEM) and wear mechanisms were discussed in this study.  相似文献   

19.
Dong-Wook Kim  Kyung-Woong Kim 《Wear》2013,297(1-2):722-730
Friction and wear tests were performed to investigate effects of sliding velocity and normal load on tribological characteristics of a multi-layered diamond-like carbon (DLC) coating for machine elements. The DLC coatings which consist of sequentially deposited gradient Cr/CrN, W-doped DLC (a-C:H:W) and DLC (a-C:H) layers were formed on carburized SCM 415 Cr–Mo steel disks using a reactive sputtering system. The tests against AISI 52100 steel balls were performed under various sliding velocities (0.0625, 0.125, 0.25, 0.5, 1 and 2 m/s) and normal loads (6.1, 20.7 and 49.0 N) in ambient air (relative humidity=26±2%, temperature=18±2 °C). Each test was conducted for 20 km sliding distance without lubricating oil. The results show that friction coefficients decrease with the increase in sliding velocity and normal load. Wear rates of both surfaces decrease with the increase in normal load. The increase in sliding velocity leads initially to the increase in wear rates up to the maximum value. Then, they decrease, as the sliding velocity increases above specific value that corresponds to the maximum wear rate. Through surface observation and analysis, it is confirmed that formation of transfer layers and graphitized degree of wear surfaces of DLC coatings mainly affect its tribological characteristics.  相似文献   

20.
《Wear》2006,260(4-5):401-411
In case of fabric reinforced composites of specialty polymers influence of orientation of fabric and its volume fraction on tribo-behaviour is sparingly studied. In our earlier work, we have reported on the influence of amount of Aramid fabric (AF) in polyethersulfone (PES) on abrasive wear performance. However, orientation effect of fabric with respect to abrading plane was not investigated. In this work three orientations of composites of PES containing Aramid (Kevlar 29) fabric with three concentrations 64, 72 and 83 wt.% were selected to study the influence on abrasive wear performance. Composites developed by compression molding technique were characterized for their mechanical and physical properties. The abrasive wear performance of the composites was evaluated by abrading 10 mm × 10 mm × 10 mm sample against silicon carbide (SiC) paper under various loads and two grades of abrasive papers. The fabric reinforcement enhanced the abrasive wear resistance of PES significantly (approximately 1.35–9.46 times depending on the operating conditions). It was observed that 83% fabric composite showed the highest resistance to abrasive wear and impact along with the best tensile strength and elongation properties. Its flexural strength and ILSS values, however, were the lowest. Sixty-four percent fabric composite, on the other hand, showed an exactly reverse trend among the three composites. Among the three orientations, fibres in normal and parallel (N–P) and normal and anti-parallel (N–AP) direction with respect to sliding plane proved to impart maximum wear resistance. N–P was best for light loads while N–AP was best for high loading conditions. Orientation parallel and anti-parallel (P–AP) was least beneficial in this respect. Moreover, the extent of improvement very much depended on the operating parameters such as grit size and load. Benefits endowed due to reinforcement were higher at less coarse grade paper. With increase in load, however, wear rate of composites with N–P orientation increased and for other two orientations it decreased. Thus, for severe operating conditions, N–AP orientation proved to be most beneficial. SEM studies proved supporting for understanding the influence of orientation on wear performance.  相似文献   