首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 976 毫秒
1.
Tungsten particles have been introduced into the National Spherical Torus Experiment (NSTX) in Princeton with the purpose to investigate the effects of tungsten injection on subsequent plasma discharges. An experimental setup for the study of tungsten particle transport is described where the particles are introduced into the tokamak using a modified particle dropper, otherwise used for lithium-powder injection. An initial test employing a grazing-incidence extreme ultraviolet spectrometer demonstrates that the tungsten-transport setup could serve to infer particle transport from the edge to the hot central plasmas of NSTX.  相似文献   

2.
Tangentially viewing soft x-ray (SXR) cameras are capable of detecting nonaxisymmetric plasma structures in magnetically confined plasmas. They are particularly useful for studying stationary perturbations or phenomenon that occur on a timescale faster than the plasma rotation period. Tangential SXR camera diagnostics are planned for the DIII-D and NSTX tokamaks to elucidate the static edge magnetic structure during the application of 3D perturbations. To support the design of the proposed diagnostics, a synthetic diagnostic model was developed using the CHIANTI database to estimate the SXR emission. The model is shown to be in good agreement with the measurements from an existing tangential SXR camera diagnostic on NSTX.  相似文献   

3.
A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar(16+) and will provide ion temperature profiles with spatial and temporal resolutions of <2?cm and ≥10?ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.  相似文献   

4.
A novel diagnostic design seeks to enhance the capability of multienergy soft x-ray (SXR) detection by using an image intensifier to amplify the signals from a larger set of filtered x-ray profiles. The increased number of profiles and simplified detection system provides a compact diagnostic device for measuring T(e) in addition to contributions from density and impurities. A single-energy prototype system has been implemented on NSTX, comprised of a filtered x-ray pinhole camera, which converts the x-rays to visible light using a CsI:Tl phosphor. SXR profiles have been measured in high performance plasmas at frame rates of up to 10 kHz, and comparisons to the toroidally displaced tangential multi-energy SXR have been made.  相似文献   

5.
A free standing transmission grating based imaging spectrometer in the extreme ultraviolet range has been developed for the National Spherical Torus Experiment (NSTX). The spectrometer operates in a survey mode covering the approximate spectral range from 30 to 700 A? and has a resolving capability of δλ/λ on the order of 3%. Initial results from space resolved impurity measurements from NSTX are described in this paper.  相似文献   

6.
A new laboratory x-ray spectrometer for surface-sensitive extended x-ray absorption fine structure [(S)EXAFS] and surface-sensitive x-ray absorption near-edge structure [(S)XANES] measurements is described. The spectrometer employs a 12 kV mA rotating anode generator. It has a monochromator equipped with a set of exchangeable curved crystals of Johann or Johansson type with different cell parameters, orientations, and Rowland radii. The computer controlled movement system based on nine stepping motors allows all the main elements of the spectrometer to be positioned freely relative to the x-ray source and gives an opportunity to use sophisticated scanning modes (for example, a mode with a focus spot position on a sample surface instead of an exit slit). The whole x-ray beam line is completely enclosed in a vacuum chamber that is directly connected to the x-ray generator, thereby preventing the absorption of x rays in the air. This layout allows a wide x-ray photon energy range from a few keV up to dozens of keV. A registration of x rays transmitted through the sample with proportional counter- and photoelectrons emitted from the sample with channeltron is used to carry out bulk- and surface-sensitive measurements, respectively. Using a 25 x 200 kV mA power regime of a rotating anode x-ray generator, a photon flux of 2.5 x 10(5) counts/s was registered at the Cu K edge, where the energy resolution was about 5 eV. High near surface sensitivity is demonstrated by the EXAFS spectra of Cu K and Hf LIII edges measured from 3 nm Cu and Hf oxide films.  相似文献   

7.
New x-ray imaging crystal spectrometers, currently operating on Alcator C-Mod, NSTX, EAST, and KSTAR, record spectral lines of highly charged ions, such as Ar(16+), from multiple sightlines to obtain profiles of ion temperature and of toroidal plasma rotation velocity from Doppler measurements. In the present work, we describe a new data analysis routine, which accounts for the specific geometry of the sightlines of a curved-crystal spectrometer and includes corrections for the Johann error to facilitate the tomographic inversion. Such corrections are important to distinguish velocity induced Doppler shifts from instrumental line shifts caused by the Johann error. The importance of this correction is demonstrated using data from Alcator C-Mod.  相似文献   

8.
A 2400 lines/mm variable-spaced grating spectrometer has been used to measure soft x-ray emission (8-22 A?) from laser-produced plasma experiments at Lawrence Livermore National Laboratory's Compact Multipulse Terrawatt (COMET) Laser Facility. The spectrometer was coupled to a Kentech x-ray streak camera to study the temporal evolution of soft x rays emitted from the back of the Mylar and the copper foils irradiated at 10(15)?W/cm(2). The instrument demonstrated a resolving power of ~120 at 19 A? with a time resolution of 31 ps. The time-resolved copper emission spectrum was consistent with a photodiode monitoring the laser temporal pulse shape and indicated that the soft x-ray emission follows the laser heating of the target. The time and spectral resolutions of this diagnostic make it useful for studies of high temperature plasmas.  相似文献   

9.
A flat-field extreme ultraviolet (EUV) spectrometer with a varied line spacing groove grating (1200 grooves/mm at grating center) has been developed to study the emission spectra from highly ionized medium Z impurities in large helical device (LHD). It covers a wavelength range of 50-500 A using a mechanically ruled grating, which was later replaced by a newly developed laminar-type holographic grating for comparative studies. Differences in spectral resolution, intensities of higher order spectra, and sensitivities of the spectrometer were studied between the two gratings by observing the emission spectra of LHD plasmas. Although the achieved resolution was alike between them, i.e., deltalambda approximately 0.24 A at 200 A, the holographic grating was much superior in suppressing the higher order light than the ruled grating. The relative sensitivity between the two gratings was evaluated using continuum radiation from LHD plasmas. As a result, it was found that the holographic grating has a flat response in the full wavelength range, but the sensitivity of the ruled grating drops sharply below 200 A. A new technique for the absolute calibration of the EUV holographic grating spectrometer was tried by combining the continuum radiation with a branching ratio of C IV lines (3p-3s: 5800 A/3p-2s: 312 A), and an accurate absolute sensitivity has been successfully obtained.  相似文献   

10.
An x-ray imaging crystal spectrometer was designed for the Hanbit magnetic mirror device to observe spectra of heliumlike neon at 13.4474 A. The spectrometer consists of a spherically bent mica crystal and an x-ray sensitive vacuum charge coupled device camera. This spectrometer can provide spatially resolved spectra, making it possible to obtain profiles of the ion charge state distribution from line ratios and profiles of the plasma rotation velocity from Doppler shift measurements. The paper describes measurements of spectral resolution of this instrument for low x-ray energies.  相似文献   

11.
激光等离子体X射线极化光谱研究   总被引:1,自引:1,他引:0  
为了诊断激光等离子体X射线的极化光谱,研制了一种新型的基于空间分辨的极化谱仪。将平面晶体和球面弯晶色散元件在极化谱仪内正交布置,即在水平通道用PET平面晶体作为色散元件,而在垂直通道用Mica球面弯晶作为色散元件,球面半径为380mm。信号采用成像板进行接收,有效接收面积为30×80mm,从等离子体光源经晶体到成像板的光路约为980mm。物理实验首次在中国工程物理研究院激光聚变研究中心“2×10J激光装置”上进行,成像板获得了铝激光等离子体X射线的光谱空间分辨信号。实验结果表明该谱仪具有较高谱分辨率,适合激光等离子体x射线极化光谱的诊断。  相似文献   

12.
An inner-shell photoionized x-ray laser pumped by the Linac Coherent Light Source (LCLS) free electron laser has been proposed recently. The measurement of the on-axis 849 eV Ne?Kα laser and protection of the x-ray spectrometer from damage require attenuation of the 1 keV LCLS beam. An Al/Cu foil combination is well suited, serving as a low energy bandpass filter below the Cu L-edge at 933 eV. A high resolution grating spectrometer is used to measure the transmission of a candidate filter with an intense laser-produced x-ray backlighter developed at the Lawrence Livermore National Laboratory Jupiter Laser Facility Janus. The methodology and discussion of the observed fine structure above the Cu L-edge will be presented.  相似文献   

13.
Different metal targets were investigated as possible source material for tailored laser-produced plasma-sources. In the wavelength range from 1 to 20 nm, x-ray spectra were collected with a calibrated spectrometer with a resolution of λ/Δλ = 150 at 1 nm up to λ/Δλ = 1100 at 15 nm. Intense line emission features of highly ionized species as well as continuum-like spectra from unresolved transitions are presented. With this knowledge, the optimal target material can be identified for the envisioned application of the source in x-ray spectrometry on the high energy side of the spectra at about 1 keV. This energy is aimed for because 1 keV-radiation is ideally suited for L-shell x-ray spectroscopy with nm-depth resolution.  相似文献   

14.
X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.  相似文献   

15.
We have calibrated the x-ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL and at both the Omega and Omega EP lasers at the University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range of ~6-60?A?. The calibration results presented here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from the hydrogenlike and heliumlike ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x-ray intensities recorded by the VSG to those simultaneously recorded by an x-ray microcalorimeter spectrometer.  相似文献   

16.
A dual-channel, focusing x-ray spectrograph with uniform dispersion (i.e., the linear dispersion of this spectrograph is a constant) is described for measuring the x-ray spectra emission from the hot, dense Al Z pinch plasmas. The spectrograph uses double uniform-dispersed crystals (e.g., a Quartz 1010 crystal and a Mica 002 crystal) as dispersion elements and a double-film box as detector to achieve the simultaneous recording of the time integrated spectrum covering a wide spectral range of ~5-9 A?. Since this spectrograph disperse the x-rays on the detector plane with uniform spacing for every wavelength, it needs not the calibration of the wavelength with spatial coordinate, thereby own the advantages of easiness and veracity for spectra identification. The design of this spectrograph and the example of experiment on the "Yang" accelerator are presented.  相似文献   

17.
A Johann-type spectrometer with five spherically bent crystals and a pixel detector was constructed for a range of hard x-ray photon-in photon-out synchrotron techniques, covering a Bragg-angle range of 60°-88°. The spectrometer provides a sub emission line width energy resolution from sub-eV to a few eV and precise energy calibration, better than 1.5 eV for the full range of Bragg angles. The use of a pixel detector allows fast and easy optimization of the signal-to-background ratio. A concentration detection limit below 0.4 wt% was reached at the Cu Kα(1) line. The spectrometer is designed as a modular mobile device for easy integration in a multi-purpose hard x-ray synchrotron beamline, such as the SuperXAS beamline at the Swiss Light Source.  相似文献   

18.
用于测量激光等离子体X射线的椭圆弯晶谱仪   总被引:2,自引:2,他引:0  
研制了一种椭圆弯晶谱仪用于测量0.44~0.81 nm激光等离子体X射线光谱.该谱仪采用X射线CCD作探测器,用PET(2d=0.874 nm)晶体作色散和聚焦元件,将晶体弯曲并粘贴在离心率和焦距分别为0.9586和1350 mm的椭圆形不锈钢基底上.对该谱仪在"星光Ⅱ"激光装置上进行了打靶实验,实验结果表明其光谱分辨率接近1000.  相似文献   

19.
X-ray fluorescence analysis is a highly useful technique for determining the chemical composition of matter. The present article describes the successful development of a wavelength-dispersive x-ray fluorescence spectrometer for a fairly high-energy range, 30-60 keV, that can contribute to studying lanthanides' Kbeta spectra with high-energy resolution. By combining a new high-energy synchrotron light source and the present spectrometer, it has been demonstrated that the full width at half maximum for lanthanum's Kbeta(1) is 32 eV and that all the peaks in the spectra are fully resolved. This corresponds to an energy resolution EDeltaE of 1180, which is ten times better than a conventional system based on a Ge detector, which can detect only two peaks, Kbeta(1) and Kbeta(2), in seven peaks. The present spectrometer can open up a new field in x-ray spectrometry.  相似文献   

20.
We discuss the processing of x-ray absorption spectra from photoionized plasma experiments at Z. The data was recorded with an imaging spectrometer equipped with two elliptically bent potassium acid phthalate (KAP) crystals. Both time-integrated and time-resolved data were recorded. In both cases, the goal is to obtain the transmission spectra for quantitative analysis of plasma conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号