首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A major upgrade to the ruby Thomson scattering (TS) system has been designed and implemented on the Mega-ampere spherical tokamak (MAST). MAST is equipped with two TS systems, a Nd:YAG laser system and a ruby laser system. Apart from common collection optics each system provides independent measurements of the electron temperature and density profile. This paper focuses on the recent upgrades to the ruby TS system. The upgraded ruby TS system measures 512 points across the major radius of the MAST vessel. The ruby laser can deliver one 10 J 40 ns pulse at 1 Hz or two 5 J pulses separated by 100-800 μs. The Thomson scattered light is collected at F/15 over 1.4 m. This system can resolve small (7 mm) structures at 200 points in both the electron temperature and density channels at high optical contrast; ~50% modulated transfer function. The system is fully automated for each MAST discharge and requires little adjustment. The estimated measurement error for a 7 mm radial point is <4% of T(e) and <3% of n(e) in the range of 40 eV to 2 keV, for a density of n(e)=2×10(19) m(-3). The photon statistics at lower density can be increased by binning in the radial direction as desired. A new intensified CCD camera design allows the ruby TS system to take two snapshots separated with a minimum time of 230 μs. This is exploited to measure two density and temperature profiles or to measure the plasma background light.  相似文献   

2.
This article describes the completely renovated Thomson scattering (TS) diagnostic employed in the modified Reversed Field eXperiment (RFX-mod) since it restarted operation in 2005. The system measures plasma electron temperature and density profiles along an equatorial diameter, measuring in 84 positions with 7 mm spatial resolution. The custom built Nd:YLF laser produces a burst of 10 pulses at 50 Hz with energy of 3 J, providing ten profile measurements in a plasma discharge of about 300 ms duration. An optical delay system accommodates three scattering volumes in each of the 28 interference filter spectrometers. Avalanche photodiodes detect the Thomson scattering signals and allow them to be recorded by means of waveform digitizers. Electron temperature is obtained using an alternative relative calibration method, based on the use of a supercontinuum light source. Rotational Raman scattering in nitrogen has supplied the absolute calibration for the electron density measurements. During RFX-mod experimental campaigns in 2005, the TS diagnostic has demonstrated its performance, routinely providing reliable high resolution profiles.  相似文献   

3.
A new 10 channel Thomson scattering (TS) system was installed on the ASDEX Upgrade tokamak to measure radial profiles of electron density and temperature at the plasma edge with high radial resolution. Together with the already existing TS system, which is now used for the core plasma, electron density and temperature profiles extending from the edge to the core are now obtained in a single discharge. The TS systems are relatively calibrated by an optical parametric oscillator.  相似文献   

4.
A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a "Generation III" image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n(e)) and 6% in the electron temperature (T(e)) at n(e) = 4 x 10(19) m(-3). This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9 x 10(17) m(-3) in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n(e) and T(e) measurement is 7 x 10(20)n(e) J, which means that single shot measurements are possible for n(e)>2 x 10(21) m(-3).  相似文献   

5.
To measure the electron temperature (T(e)) and electron density (n(e)) profiles in the Korean Superconducting Tokamak Advanced Research (KSTAR) device for the KSTAR third campaign (September 2010), we designed and installed a Thomson scattering system. The KSTAR Thomson scattering system is designed as a tangential Thomson scattering system and utilizes the N-, L-, and B-ports. The N-port is designed for the collection optics with a cassette system, the L-port is the laser input port, and the B-port is the location of the beam dump. In this paper, we will describe the final design of the KSTAR Thomson scattering system.  相似文献   

6.
A new high repetition rate Nd:YAG Thomson scattering system has been designed for the Heliotron J helical device. The main purpose of installing the new Thomson scattering system is an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with ~10?mm resolution. Two high repetition Nd:YAG lasers (>550?mJ?at?50?Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time interval. Scattered light is collected with a large concave mirror (D=800?mm,?f/2.25) with a solid angle of ~100?msr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected (scattering angle is 20°). Model simulation of the polychromator shows the measurable electron temperature and density range are from 10 eV to 10 keV, >5×10(18)?m(-3) within 3% error for the temperature measurement, respectively.  相似文献   

7.
8.
Pulsed polarimetry in combination with a high speed photographic technique based on the optical Kerr effect is described. The backscatter in a pulsed polarimeter is directed through a scattering cell and photographed using an ~1?ps shutter, essentially freezing the intensity pattern. The image provides both the local electron density and magnetic field distributions along and transverse to the laser sightline. Submillimeter spatial resolution is possible for probing wavelengths in the visible due to the high densities and strong optical activity. Pulsed polarimetry is thereby extended to centimeter-sized plasmas with n(e)>10(19)-10(20)?cm(-3) and B>20-100?T (MG) produced by multiterawatt, multimega-ampere electrical drivers, wire Z pinches, and liner imploded magnetized plasmas.  相似文献   

9.
A multiframe, high-time resolution pump-probe diagnostic consisting of a consecutive train of ultrashort laser pulses (approximately ps) has been developed for use with a chirped pulse amplification (CPA) system. A system of high quality windows is used to create a series of 1054 nm picosecond-laser pulses which are injected into the CPA system before the pulse stretcher and amplifiers. By adding or removing windows in the pulse train forming optics, the number of pulses can be varied. By varying the distance and thickness of the respective optical elements, the time in between the pulses, i.e., the time in between frames, can be set. In our example application, the CPA pulse train is converted to 527 nm using a KDP crystal and focused into a preformed plasma and the reflected laser light due to stimulated Raman scattering is measured. Each pulse samples different plasma conditions as the plasma evolves in time, producing more data on each laser shot than with a single short pulse probe. This novel technique could potentially be implemented to obtain multiple high-time resolution measurements of the dynamics of physical processes over hundreds of picoseconds or even nanoseconds with picosecond resolution on a single shot.  相似文献   

10.
The present work is motivated by a long standing discrepancy between the electron temperature measurements of Thomson scattering (TS) and electron cyclotron emission (ECE) diagnostics for plasmas with strong auxiliary heating observed at both JET and TFTR above 6–7 keV, where in some cases the ECE electron temperature measurements can be 15%–20% higher than the TS measurements. Recent analysis based on ECE results at JET has shown evidence of distortions to the Maxwellian electron velocity distribution and a correlation with the TS and ECE discrepancies has been suggested. In this paper, a technique to determine the presence of non-Maxwellian behavior using TS diagnostics is outlined. The difficulties and limitations of modern TS system designs to determine the electron velocity distribution are also discussed. It is demonstrated that small deviations such as those suggested by previous ECE analysis could be potentially detected, depending on the spectral layout of the TS polychromators. The spectral layout of the JET high resolution Thomson scattering system is such that it could be used to determine these deviations between 1 and 6 keV, and the results presented here indicate that no evidence of non-Maxwellian behavior is observed in this range. In this paper, a modification to the current polychromator design is proposed, allowing non-Maxwellian distortions to be detected up to at least 10 keV.  相似文献   

11.
This paper presents designs of collection optics for a JT-60SA Thomson scattering system. By using tangential (to the toroidal direction) YAG laser injection, three collection optics without strong chromatic aberration generated by the wide viewing angle and small design volume were found to measure almost all the radial space. For edge plasma measurements, the authors optimized the channel number and wavelength ranges of band-pass filters in a polychromator to reduce the relative error in T(e) by considering all spatial channels and a double-pass laser system with different geometric parameters.  相似文献   

12.
This paper describes a 561 nm laser heterodyne interferometer that provides time-resolved measurements of line-integrated plasma electron density within the range of 10(15)-10(18) cm(-2). Such plasmas are produced by railguns on the plasma liner experiment, which aims to produce μs-, cm-, and Mbar-scale plasmas through the merging of 30 plasma jets in a spherically convergent geometry. A long coherence length, 320 mW laser allows for a strong, sub-fringe phase-shift signal without the need for closely matched probe and reference path lengths. Thus, only one reference path is required for all eight probe paths, and an individual probe chord can be altered without altering the reference or other probe path lengths. Fiber-optic decoupling of the probe chord optics on the vacuum chamber from the rest of the system allows the probe paths to be easily altered to focus on different spatial regions of the plasma. We demonstrate that sub-fringe resolution capability allows the interferometer to operate down to line-integrated densities of the order of 5 × 10(15) cm(-2).  相似文献   

13.
The collection optics designs are described for the Thomson scattering diagnostic of the Korea superconducting tokamak advanced research (KSTAR) device. The optical systems collecting the light emission induced through the interaction between the plasma electrons and a laser beam are key components for the Thomson scattering system. A duo-lens system was examined, and the final optical designs were derived for Thomson scattering diagnostic of KSTAR.  相似文献   

14.
A Thomson scattering system has been designed and constructed for probing a relativistic electron beam heated plasma. Ruby laser light scattered through 90 degrees is resolved by a polychromator and detected by one of six photomultipliers. The system is capable of resolving electron temperatures of 150 eV at densities of n(e)<10(13) cm(-3) with a 4-J ruby laser and an f/9 throughput collection system. Scaling to a 10-J, f/5 system would allow resolving densities of approximately 10(12) cm(-3). System design, calibration, alignment, and data reduction are discussed. At elevated temperatures (T(e) approximately 600 eV) evidence of the relativistic blue shift was observed.  相似文献   

15.
A six-channel two-color interferometer has been developed for plasma electron density measurements in the C-2 field reversed configuration experiment. A CO(2) laser is utilized as the main probe beams, while copropagating visible HeNe laser beams are mainly sensitive to vibration. Density measurements in C-2 plasmas have shown that this is a reliable turn-key system. The maximum residual phase noise after vibration compensation is less than ±5°, corresponding to a line integral density of 3×10(18)?m(-2). The time resolution for routine operation is 2?μs.  相似文献   

16.
A new Thomson scattering diagnostic has been designed and is currently being installed on the COMPASS tokamak in IPP Prague in the Czech Republic. The requirements for this system are very stringent with approximately 3 mm spatial resolution at the plasma edge. A critical part of this diagnostic is the laser source. To achieve the specified parameters, a multilaser solution is utilized. Two 30 Hz 1.5 J Nd:YAG laser systems, used at the fundamental wavelength of 1064 nm, are located outside the tokamak area at a distance of 20 m from the tokamak. The design of the laser beam transport path is presented. The approach leading to a final choice of optimal focusing optics is given. As well as the beam path to the tokamak, a test path of the same optical length was built. Performance tests of the laser system carried out using the test path are described.  相似文献   

17.
A new laser-based alignment system for the precise alignment of accelerator components along an ideal straight line at the KEK B-factory injector linear accelerator (linac) is under development. This system is strongly required in the next generation of B-factories for the stable acceleration of high-brightness electron and positron beams with high bunch charges and also for maintaining the stability of injection beams with high quality. A new laser optics for the generation of a so-called Airy beam has been developed for the laser-based alignment system. The laser propagation characteristics both in vacuum and at atmospheric pressure have been systematically investigated in an 82-m-long straight section of the injector linac. The laser-based alignment measurements based on the new laser optics have been carried out with a measurement resolution of ±0.1 mm level by using an existing laser detection electronics. The horizontal and vertical displacements from a reference laser line measured using this system are in good agreement with those measured using a standard telescope-based optical alignment technique. In this report, we describe the experimental study in detail along with the basic designs and the recent developments in the new laser-based alignment system.  相似文献   

18.
Photonic devices are becoming the cornerstone of next generation systems for computing and information processing. This paper reports on the first steps in the development of methods to understand these devices with nanometric (10?7 cm) spatial and femtosecond (10?15 s) time resolution. The basis of this achievement is the dramatic developments that have occurred in the past few years in a new area of optics called near-field optics. Near-field optics is a form of lensless optics with a resolution that is subwavelength and which is independent of the wavelength of the light being employed. We report in this paper the transmission of pulses with tens of femtosecond duration through subwavelength, near-field optical elements. We also report on a femtosecond near-field optical light source with cross-correlating capabilities and on the growth of GaAs in the tip of micropipettes for use as an ultra-fast electro-optical switch which can cross-correlate optical, electrical, and electro-optical effects. These developments are especially relevant in the investigation of photonic devices since such devices can alter their characteristics as a function of size in the mesoscopic regime from just below lens-based optical resolutions to dimensions that approach atomic scales of ~1 nm (10?7 cm). In view of the fact that these devices and the processes that govern them also exhibit ultrafast speeds, the combination of state of the art femtosecond laser spectroscopy with the unique features of near-field optics is a critical step in advancing our next generation understandings of such materials and structures so that their full potential in information processing can be achieved.  相似文献   

19.
Dust particles have been observed with Thomson scattering systems on several tokamaks. We present here the first evidence of dust particles observed by the new high resolution Thomson scattering system on JET. The system consists of filter spectrometers that analyze the Thomson scattering spectrum from 670 to 1050 nm in four spectral channels. The laser source is a 5 J Q-switched Nd:YAG laser. Without a spectral channel at the laser wavelength, only dust particles that emit broadband light could be detected; these particles have been observed on JET after disruptions. The timing of their emission is clearly different from that expected for a Thomson scattering pulse. The light pulse from dust happens after the peak of the laser light and has a long tail.  相似文献   

20.
The unique capabilities of ultrashort pulse femtosecond lasers have been integrated with a focused ion beam (FIB) platform to create a new system for rapid 3D materials analysis. The femtosecond laser allows for in situ layer-by-layer material ablation with high material removal rates. The high pulse frequency (1 kHz) of ultrashort (150 fs) laser pulses can induce material ablation with virtually no thermal damage to the surrounding area, permitting high resolution imaging, as well as crystallographic and elemental analysis, without intermediate surface preparation or removal of the sample from the chamber. The TriBeam system combines the high resolution and broad detector capabilities of the DualBeam(TM) microscope with the high material removal rates of the femtosecond laser, allowing 3D datasets to be acquired at rates 4-6 orders of magnitude faster than 3D FIB datasets. Design features that permit coupling of laser and electron optics systems and positioning of a stage in the multiple analysis positions are discussed. Initial in situ multilayer data are presented.  相似文献   