首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Understanding hot electron distributions generated inside Hohlraums is important to the national ignition campaign for controlling implosion symmetry and sources of preheat. While direct imaging of hot electrons is difficult, their spatial distribution and spectrum can be deduced by detecting high energy x-rays generated as they interact with target materials. We used an array of 18 pinholes with four independent filter combinations to image entire Hohlraums with a magnification of 0.87× during the Hohlraum energetics campaign on NIF. Comparing our results with Hohlraum simulations indicates that the characteristic 10-40 keV hot electrons are mainly generated from backscattered laser-plasma interactions rather than from Hohlraum hydrodynamics.  相似文献   

2.
The first demonstration of laser driven dynamic Hohlraums (LDDH) as a spectrally smooth backlighter source for opacity and temperature measurements through absorption spectrometry of materials in local thermodynamic equilibrium at temperatures >150 eV has been made. This is a crucial temperature regime for future astrophysics and ignition fusion experiments at the nearly completed National Ignition Facility (NIF) [E. I. Moses and C. R. Wuest, Fusion Sci. Technol. 47, 314 (2005)] at the Lawrence Livermore National Laboratory. The new backlighter consists of a LDDH filled with either krypton or argon that implodes to create an x-ray flash. The properties of this x-ray flash have been measured in experiments at the Omega laser [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] at the Laboratory for Laser Energetics in Rochester, New York, satisfying all requirements imposed by future experiments: (1) the emission spectrum extends to at least 5.5 keV, well above the maximum x-ray energy ( approximately 3.5 keV) obtained from the previously "best" opacity backlighters (uranium M-shell emission backlighters); (2) the spectrum is smooth and featureless (intensity variation <6% rms), allowing absorption spectrometry through experimental samples; (3) the emission source size is sufficiently small (<50 microm) for projection backlighting through future samples; (4) the emission is bright enough (and twice as bright as imploding hydrogen-filled capsules) for gated spectrometer measurements; (5) the emission duration is optimized ( approximately 100 ps) for the current and future generations of spectrometers; and (6) by using only a small number of beams with limited energy and symmetry for the backlighter (10 out of 60 beams in the Omega experiments), the majority of laser beams are left available for heating sample materials to >150 eV.  相似文献   

3.
The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an ~20?times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30±10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of ~2×10(15)?W/cm(2) for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1×10(14)?W/cm(2) over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to ±5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30±10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.  相似文献   

4.
An upgraded x-ray spectroscopy diagnostic is used to measure the distribution of fast electrons in MST and to determine Z(eff) and the particle diffusion coefficient D(r). A radial array of 12 CdZnTe hard-x-ray detectors measures 10-150 keV Bremsstrahlung from fast electrons, a signature of reduced stochasticity and improved confinement in the plasma. A new Si soft-x-ray detector measures 2-10 keV Bremsstrahlung from thermal and fast electrons. The shaped output pulses from both detector types are digitized and the resulting waveforms are fit with Gaussians to resolve pileup and provide good time and energy resolution. Lead apertures prevent detector saturation and provide a well-known etendue, while lead shielding prevents pickup from stray x-rays. New Be vacuum windows transmit >2?keV x-rays, and additional Al and Be filters are sometimes used to reduce low energy flux for better resolution at higher energies. Measured spectra are compared to those predicted by the Fokker-Planck code CQL3D to deduce Z(eff) and D(r).  相似文献   

5.
In Large Helical Device (LHD) experiments, an electron temperature (T(e)) more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, 50?eV≤T(e)≤10?keV, the data quality becomes worse in the higher T(e) region exceeding 10 keV. In order to accurately determine T(e) in the LHD high-T(e) experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured T(e). Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on T(e) obtained by the LHD Thomson scattering system.  相似文献   

6.
The construction of a pulsed electron gun for ultrafast reflection high-energy electron diffraction experiments at surfaces is reported. Special emphasis is placed on the characterization of the electron source: a photocathode, consisting of a 10 nm thin Au film deposited onto a sapphire substrate. Electron pulses are generated by the illumination of the film with ultraviolet laser pulses of femtosecond duration. The photoelectrons are emitted homogeneously across the photocathode with an energy distribution of 0.1 eV width. After leaving the Au film, the electrons are accelerated to kinetic energies of up to 15 keV. Focusing is accomplished by an electrostatic lens. The temporal resolution of the experiment is determined by the probing time of the electrons traveling across the surface which is about 30 ps. However, the duration of the electron pulses can be reduced to less than 6 ps.  相似文献   

7.
The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat a? l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.  相似文献   

8.
The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60?μm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.  相似文献   

9.
The design and characteristics of the spectrometry system for -particles and conversion electrons in an energy range of 15 to 3000 keV and X-rays in an energy range of 2 to 60 keV are described. The radiation is detected by a SiLi detector with a 500-mm2 sensitive area 4.5 mm thick. The energy resolution for the conversion electrons with an energy of 624 keV is < 2.0 keV, and for X-rays with an energy of 5.9 keV, it is <280 eV.  相似文献   

10.
Absolute bang time measurements with the gas Cherenkov detector (GCD) and gamma reaction history (GRH) diagnostic have been performed to high precision at the OMEGA laser facility at the University of Rochester with bang time values for the two diagnostics agreeing to within 5 ps on average. X-ray timing measurements of laser-target coupling were used to calibrate a facility-generated laser timing fiducial with rms spreads in the measured coupling times of 9 ps for both GCD and GRH. Increased fusion yields at the National Ignition Facility (NIF) will allow for improved measurement precision with the GRH easily exceeding NIF system design requirements.  相似文献   

11.
The design of small spectrometers of laser-plasma electrons with energies in the range 1–1000 keV is described. A technique for calibrating spectrometers is presented. The results of measuring an electron spectrum in a laser experiment performed with these spectrometers are presented.  相似文献   

12.
High-energy x-rays, >10?keV, can be efficiently produced from ultrafast laser target interactions with many applications to dense target materials in inertial confinement fusion and high-energy density physics. These same x-rays can also be applied to measurements of low-density materials inside high-density Hohlraum environments. In the experiments presented, high-energy x-ray images of laser-shocked polystyrene are produced through phase contrast imaging. The plastic targets are nominally transparent to traditional x-ray absorption but show detailed features in regions of high density gradients due to refractive effects often called phase contrast imaging. The 200 TW Trident laser is used both to produce the x-ray source and to shock the polystyrene target. X-rays at 17 keV produced from 2 ps, 100 J laser interactions with a 12?μm molybdenum wire are used to produce a small source size, required for optimizing refractive effects. Shocks are driven in the 1 mm thick polystyrene target using 2 ns, 250 J, 532 nm laser drive with phase plates. X-ray images of shocks compare well to one-dimensional hydro calculations.  相似文献   

13.
A new high repetition rate Nd:YAG Thomson scattering system has been designed for the Heliotron J helical device. The main purpose of installing the new Thomson scattering system is an investigation of an improved confinement physics such as the edge transport barrier (H-mode) or the internal transport barrier of the helical plasma. The system has 25 spatial points with ~10?mm resolution. Two high repetition Nd:YAG lasers (>550?mJ?at?50?Hz) realize the measurement of the time evolution of the plasma profile with 10 ms time interval. Scattered light is collected with a large concave mirror (D=800?mm,?f/2.25) with a solid angle of ~100?msr. The laser beam is injected from obliquely downward to upward, and obliquely backscattered light is detected (scattering angle is 20°). Model simulation of the polychromator shows the measurable electron temperature and density range are from 10 eV to 10 keV, >5×10(18)?m(-3) within 3% error for the temperature measurement, respectively.  相似文献   

14.
Experiments on the National Ignition Facility (NIF) will require bright, short duration, near-monochromatic x-ray backlighters for radiographic diagnosis of many high-energy density systems. This paper details a vanadium pinhole backlighter producing (1.8±0.5)×10(15) x-ray photons into 4π sr near the vanadium He-like characteristic x-ray energy of 5.18 keV. The x-ray yield was quantified from a set of Ross filters imaged to a calibrated image plate, with the Dante diagnostic used to confirm the quasimonochromatic nature of the spectrum produced. Additionally, an x-ray film image shows a source-limited image resolution of 26?μm from a 20?μm diameter pinhole.  相似文献   

15.
A separator of monoenergetic electrons is described, in which two kinds of assemblies of “miniorange”-type magnetic filters (six magnets in each) are used. The 207Bi isotope with an activity of 240 kBq (7 μCi) that emits K 1063 and K 1770 conversion electrons serves as the electron source. For different kinds of assemblies, the intensity of electrons with energies of ~970 and ~1680 keV is accompanied by an increase in the radiation intensity by factors of 3 and 4, respectively, as compared to the intensities measured without magnetic filters, the energy resolution being ~30 keV. A single cycle of chamber evacuation guarantees constancy of the instrument’s parameters for one month.  相似文献   

16.
We have developed and demonstrated a versatile, compact electron source that can produce a mono-energetic electron beam up to 50 mm in diameter from 0.1 to 30 keV with an energy spread of <10 eV. By illuminating a metal cathode plate with a single near ultraviolet light emitting diode, a spatially uniform electron beam with 15% variation over 1 cm(2) can be generated. A uniform electric field in front of the cathode surface accelerates the electrons into a beam with an angular divergence of <1° at 1 keV. The beam intensity can be controlled from 10 to 10(9) electrons cm(-2) s(-1).  相似文献   

17.
The first 3 of 18 neutron time-of-flight (nTOF) channels have been installed at the National Ignition Facility (NIF). The role of these detectors includes yield, temperature, and bang time measurements. This article focuses on nTOF data analysis and quality of results obtained for the first set of experiments to use all 192 NIF beams. Targets produced up to 2×10(10) 2.45 MeV neutrons for initial testing of the nTOF detectors. Differences in neutron scattering at the OMEGA laser facility where the detectors were calibrated and at NIF result in different response functions at the two facilities. Monte Carlo modeling shows this difference. The nTOF performance on these early experiments indicates that the nTOF system with its full complement of detectors should perform well in future measurements of yield, temperature, and bang time.  相似文献   

18.
X-ray line spectra ranging from 17 to 77 keV were quantitatively measured with a Laue spectrometer, composed of a cylindrically curved crystal and a detector. Either a visible CCD detector coupled with a CsI phosphor screen or an imaging plate can be chosen, depending on the signal intensities and exposure times. The absolute sensitivity of the spectrometer system was calibrated using pre-characterized laser-produced x-ray sources and radioisotopes. The integrated reflectivity for the crystal is in good agreement with predictions by an open code for x-ray diffraction. The energy transfer efficiency from incident laser beams to hot electrons, as the energy transfer agency for specific x-ray line emissions, is derived as a consequence of this work.  相似文献   

19.
A simple technique for single-shot microscopic electron imaging was demonstrated for the study of intense femtosecond laser-produced plasmas. Passed through a permanent magnet lens designed for 110-keV electrons, hot electrons emitted from the plasma produced by a single laser pulse of 0.8 mJ with intensity of 3 × 10(16) W/cm(2) were successfully imaged. Analyzing this image, we found that electrons were emitted from an area of 3 μm in diameter. At higher laser intensity of 10(18) W/cm(2), distinct structures were observed in and near the focal spot of the laser; that is, the electrons were emitted from several separate spots. These results show that laser-plasma electron imaging is promising for studying the interactions of femtosecond lasers with high-density plasmas.  相似文献   

20.
Two-dimensional temperature mapping of laser heated diamond anvil cell samples is performed by processing a set of four simultaneous images of the sample, each obtained at a narrow spectral range in the visible to near infrared. The images are correlated spatially, and each set of four points is fitted to the Planck radiation function to determine the temperature and the emissivity of the sample, using the gray body approximation. The method is tested by measuring the melting point of Pt at 1 bar and measuring laser heated Fe at 20 GPa in the diamond anvil cell. The accuracy and precision are shown to compare well to standard spectroradiometry, and the effect of imaging resolution on the measured distribution is evaluated. The principal advantages of the method are (1) the temperature and emissivity of the sample are mapped in two dimensions; (2) chromatic aberrations are practically eliminated by independent focusing of each spectral band; and (3) all of the spectral images are obtained simultaneously, allowing temporal variations to be studied. This method of measuring temperature distributions can be generalized to other hot objects besides laser heated spots.  相似文献   