共查询到20条相似文献,搜索用时 11 毫秒
1.
Commissioning of electron cyclotron emission imaging instrument on the DIII-D tokamak and first data
Tobias B Domier CW Liang T Kong X Yu L Yun GS Park HK Classen IG Boom JE Donné AJ Munsat T Nazikian R Van Zeeland M Boivin RL Luhmann NC 《The Review of scientific instruments》2010,81(10):10D928
A new electron cyclotron emission imaging diagnostic has been commissioned on the DIII-D tokamak. Dual detector arrays provide simultaneous two-dimensional images of T(e) fluctuations over radially distinct and reconfigurable regions, each with both vertical and radial zoom capability. A total of 320 (20?vertical×16?radial) channels are available. First data from this diagnostic demonstrate the acquisition of coherent electron temperature fluctuations as low as 0.1% with excellent clarity and spatial resolution. Details of the diagnostic features and capabilities are presented. 相似文献
2.
Jeong SH Lee KD Kogi Y Kawahata K Nagayama Y Mase A Kwon M 《The Review of scientific instruments》2010,81(10):10D922
A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration. 相似文献
3.
Kim JB Lee W Yun GS Park HK Domier CW Luhmann NC 《The Review of scientific instruments》2010,81(10):10D931
A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment. 相似文献
4.
Zhang YP Liu Y Song XY Yuan GL Chen W Ji XQ Ding XT Yang JW Zhou J Li X Yang QW Duan XR Pan CH Liu Y 《The Review of scientific instruments》2010,81(10):103501
A fast electron bremsstrahlung (FEB) diagnostic technique based on cadmium telluride (CdTe) detector has been developed recently in the HL-2A tokamak for measurements of the temporal evolution of FEB emission in the energy range of 10-200 keV. With a perpendicular viewing into the plasma on the equatorial plane, the hard x-ray spectra with eight different energy channels are measured. The discrimination of the spectra is implemented by an accurate spectrometry. The system also makes use of fast digitization and software signal processing technology. An ambient environment of neutrons, gammas, and magnetic disturbance requires careful shielding. During electron cyclotron resonance heating, the generation of fast electrons and the oscillations of electron fishbone (e-fishbone) have been found. Using the FEB measurement system, it has been experimentally identified that the mode strongly correlates with the electron cyclotron resonance heating produced fast electrons with 30-70 keV. 相似文献
5.
Grierson BA Burrell KH Solomon WM Pablant NA 《The Review of scientific instruments》2010,81(10):10D735
Newly installed diagnostic capabilities on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 46, 6114 (2002)] enable the measurement of main ion (deuterium) velocity and temperature by charge exchange recombination spectroscopy. The uncertainty in atomic physics corrections for determining the velocity is overcome by exploiting the geometrical dependence of the apparent velocity on the viewing angle with respect to the neutral beam. 相似文献
6.
Kogi Y Jeong SH Lee KD Akaki K Mase A Kuwahara D Yoshinaga T Nagayama Y Kwon M Kawahata K 《The Review of scientific instruments》2010,81(10):10D916
We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV. 相似文献
7.
Kuwahara D Tsuji-Iio S Nagayama Y Yoshinaga T Tsuchiya H Sugito S Yamaguchi S Kogi Y Akaki K Mase A 《The Review of scientific instruments》2010,81(10):10D919
A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter. 相似文献
8.
Liang T Tobias B Kong X Domier CW Luhmann NC Lee W Yun GS Park HK 《The Review of scientific instruments》2010,81(10):10D909
The installation of a new electron cyclotron emission imaging diagnostic for the Korea Superconducting Tokamak Advanced Research (KSTAR) is underway, making use of a unique optical port cassette design, which allows placement of refractive elements inside the cryostat region without adverse effects. The result is unprecedented window access for the implementation of a state of the art imaging diagnostic. A dual-array optical design has been developed, capable of simultaneously imaging the high and low field sides of the plasma with independent features of focal plane translation, vertical zoom, and radial channel spacing. The number of translating optics has been minimized by making use of a zoom lens triplet and parabolic plasma facing lens for maximum channel uniformity over a continuous vertical zoom range of 3:1. The simulated performance of this design is presented along with preliminary laboratory characterization data. 相似文献
9.
Simonetto A Sozzi C Garavaglia S Fessey JA Nowak S;JET-EFDA Contributors 《The Review of scientific instruments》2011,82(11):113506
A Martin Puplett interferometer for electron cyclotron emission (ECE) measurements from JET tokamak plasmas was extended to multichannel operation for simultaneous radial and oblique ECE measurements. This paper describes the new optics and the instrument's performance. 相似文献
10.
Alonso MP Figueiredo AC Borges FO Elizondo JI Galvão RM Severo JH Usuriaga OC Berni LA Machida M 《The Review of scientific instruments》2010,81(10):10D529
We present the first simultaneous measurements of the Thomson scattering and electron cyclotron emission radiometer diagnostics performed at TCABR tokamak with Alfve?n wave heating. The Thomson scattering diagnostic is an upgraded version of the one previously installed at the ISTTOK tokamak, while the electron cyclotron emission radiometer employs a heterodyne sweeping radiometer. For purely Ohmic discharges, the electron temperature measurements from both diagnostics are in good agreement. Additional Alfve?n wave heating does not affect the capability of the Thomson scattering diagnostic to measure the instantaneous electron temperature, whereas measurements from the electron cyclotron emission radiometer become underestimates of the actual temperature values. 相似文献
11.
A 110/137 GHz radiometer pair with collimated antenna pattern is being used to diagnose optically thin harmonic electron cyclotron emission from hot electrons in LDX. Signal levels of 0.1-1 keV and 110/137 ratios of 2-4 stationary with ECRH power have been observed. The large plasma core magnetic field gradient causes all relevant harmonics to be simultaneously viewed over a angle(k,B) angular range of 0°-90° representing a unique geometry for interpretation of ECE in terms of hot electron temperature and density. 相似文献
12.
This paper reports on the influence of the channeling effect on the energy distribution of electrons backscattered from crystals with different atomic numbers Z. These results can be used for the optimization of the contrast of electron backscattering and electron channeling patterns. Energy and angular resolved electron scattering distributions are obtained using a 4-axial experimental setup with a moveable high-resolution spherical spectrometer. Special care is taken to suppress undesired reflections of electrons inside the spectrometer. This experimental setup allows the direct observation of the excitation of different Bloch waves (anomalous absorption and transmission) within the crystal for different electron incidence angles and the observation of angular distributions of elastically scattered electrons. Results are presented for Si and Au monocrystals, showing that the influence of the channeling effect is more distinct for low atomic numbers. 相似文献
13.
Efthimion PC Arunasalam V Bitzer R Campbell L Hosea JC 《The Review of scientific instruments》1979,50(8):949-951
We have developed a fast-scanning heterodyne receiver into a plasma diagnostic that measures the fundamental cyclotron emission from the PLT plasma and thus ascertains the time evolution of the electron temperature profile. The receiver scans 60-90 GHz every 10 ms and is interfaced to a computer for completely automated calibrated temperature measurements. 相似文献
14.
Meyer O Burrell KH Chavez JA Kaplan DH Chrystal C Pablant NA Solomon WM 《The Review of scientific instruments》2011,82(2):023114
Charge exchange spectroscopy is one of the standard plasma diagnostic techniques used in tokamak research to determine ion temperature, rotation speed, particle density, and radial electric field. Configuring a charge coupled device (CCD) camera to serve as a detector in such a system requires a trade-off between the competing desires to detect light from as many independent spatial views as possible while still obtaining the best possible time resolution. High time resolution is essential, for example, for studying transient phenomena such as edge localized modes. By installing a mask in front of a camera with a 1024 × 1024 pixel CCD chip, we are able to acquire spectra from eight separate views while still achieving a minimum time resolution of 0.2 ms. The mask separates the light from the eight spectra, preventing spatial and temporal cross talk. A key part of the design was devising a compact translation stage which attaches to the front of the camera and allows adjustment of the position of the mask openings relative to the CCD surface. The stage is thin enough to fit into the restricted space between the CCD camera and the spectrometer endplate. 相似文献
15.
Thuillier T Angot J Barué C Canet C Lamy T Lehérissier P Lemagnen F Maunoury L Peaucelle C 《The Review of scientific instruments》2012,83(2):02A339
A review of today achieved A∕Q = 3 heavy ions beams is proposed. The daily operation A∕Q = 3 ion beam intensities expected at Spiral2 are at the limit or above best record 3rd generation electron cyclotron resonance ion source (ECRIS) intensities. The necessity to build a new fully superconducting to fulfill these requirements is outlined. A discussion on the volume of the future source is proposed and the minimum value of 12 liters is derived. An analysis of the x-ray absorption superconducting ECRIS is presented based on VENUS experimental data and geometry. This study underlines the necessity to include a complete x-ray study at the time of source conception. The specifications foreseen for the new ECRIS are presented, followed with the roadmap for the design. 相似文献
16.
17.
Izotov IV Razin SV Sidorov AV Skalyga VA Zorin VG Bagryansky PA Beklemishev AD Prikhodko VV 《The Review of scientific instruments》2012,83(2):02A318
Influence of shear flows of the dense plasma created under conditions of the electron cyclotron resonance (ECR) gas breakdown on the plasma confinement in the axisymmetric mirror trap ("vortex" confinement) was studied experimentally and theoretically. A limiter with bias potential was set inside the mirror trap for plasma rotation. The limiter construction and the optimal value of the potential were chosen according to the results of the preliminary theoretical analysis. This method of "vortex" confinement realization in an axisymmetric mirror trap for non-equilibrium heavy-ion plasmas seems to be promising for creation of ECR multicharged ion sources with high magnetic fields, more than 1 T. 相似文献
18.
Figini L Garavaglia S De la Luna E Farina D Platania P Simonetto A Sozzi C;JET-EFDA Contributors 《The Review of scientific instruments》2010,81(10):10D937
The oblique electron cyclotron emission (ECE) diagnostic installed at JET allows simultaneous analysis of the ECE spectra along three lines of sight (with toroidal angles of 0°, ~ 10°, and ~ 20°) and two linear polarizations for each oblique line of sight. The diagnostic is capable of measuring EC emission over the band of 75–800 GHz with 5 ms time resolution and 7.5 GHz spectral resolution, and it is designed to investigate the features of ECE spectra related to electron distribution in the thermal velocity range. Instrumental accuracy was assessed using sources at different temperatures (77–900 K) and with plasma emission. ECE from high temperature plasmas and in the presence of fast ions has been compared to simulations performed with the modeling code SPECE, setting an upper limit to possible discrepancies from thermal emission. 相似文献
19.
20.
The backscattering factor R for characteristic radiation, which is a part of the atomic number correction commonly used in electron probe microanalysis, is calculated keeping mathematical simplifications at a minimum. The results are compared with the values calculated by means of three other often used expressions for the backscattering factor. It is shown that our results generally are similar to the ones of Duncumb and Reed and of Pouchou and Pichoir, but differ significantly from the ones of Love et al., whose expression seems not to be applicable if the overvoltage is higher than ~50. 相似文献