Twelve public office buildings were selected for a study of relationships between worker's health symptoms and a number of building, workspace, job, and personal factors. Three buildings were naturally ventilated, three were mechanically ventilated, and six were air conditioned. Information on the prevalences of work-related symptoms, demographics, and job and personal factors were determined via a questionnaire completed by 880 occupants. Several indoor environmental parameters were measured. Logistic regression models were used to evaluate associations between symptom prevalences and features of the buildings, indoor environments, jobs, and personal factors. A substantial fraction of the occupants in these typical office buildings reported frequent work-related symptoms. The occupants of the mechanically ventilated and air conditioned buildings had sipifcantly more symptoms than occupants of the naturally ventilated buildings after adjustment for confounding factors. Increased prevalences of some symptoms were associated with several job and workspace factors including: presence of carpet, increased use of carbonless copy paper and photocopiers, space sharing, and distance from a window  相似文献   

2.
A case of suspected indoor ammonia contamination from concrete was investigated in an airline company office in Beijing. A standardized questionnaire on indoor environment perceptions, medical symptoms and psychosocial work environment was distributed to all staff, and compared with a reference group of office workers from the same company in Stockholm. Temperature, relative humidity, formaldehyde, volatile organic compounds (VOC), ammonia, and carbon dioxide were measured both in Beijing and Stockholm. In Beijing mould and bacteria were also measured. Totally 95% (N = 14) participated. The Beijing staff reported a higher rate of complaints regarding poor work satisfaction, and work stress as compared to the Stockholm reference group. In the total material (N = 203) the psychosocial environment was related to general symptoms (headache and tiredness) but not odour perception or mucous membrane symptoms. Controlling for age, smoking habits, and psychosocial work environment the Beijing staff had more complaints on unpleasant odour and mucous membrane symptoms. An increased indoor concentration of ammonia (3–6 ppm) and benzene (26.8 μg/m3) was measured in the indoor air in the Beijing office, as compared to the office in Stockholm (<0.1 ppm ammonia and 0.4 μg/m3 benzene). The ammonia contamination in the Beijing office was confirmed, the probable source being additives in the concrete. The ammonia level was well below the Swedish threshold limit values (TLV) (25 ppm). In addition the exposure to benzene, an indicator of traffic exhaust pollution was high both indoors and outdoors in Beijing, possible related to increased levels of odour complaints and mucous membrane irritation.  相似文献   

3.
The study compared IAQ, thermal quality, and lighting quality between 5 different office types in LEED-certified buildings in relation to employees' environmental satisfaction and their job performance. This was to provide workplaces where workers in each specific office environment could be provided with appropriate office settings regarding these IEQ criteria when organizations comply with LEED standards. The five types of office included private enclosed, private shared, open-plan with high cubicle over 5′, open-plan with low cubicle lower than 5′, and open-plan with no partitions (bullpen) offices. The study found IAQ enhanced workers' job performance in enclosed private offices more than both high cubicles and low cubicles. All four office types had higher satisfaction with the amount of light and visual comfort of light as well as more enhancement with job performance due to lighting quality than high cubicles. There was no difference in thermal quality between the five office types. IAQ and lighting quality were not different between enclosed private, enclosed shared, and bullpen office types, either. The study findings suggest a careful workplace design considering the height of partitions in LEED-certified buildings to improve employee's environmental satisfaction and job performance.  相似文献   

4.
Occupant responses and indoor environment characteristics were recorded and compared in five mechanically and four naturally ventilated open-plan office buildings by using a simple approach that enabled us to survey many buildings simultaneously. All occupant responses were obtained during one afternoon. In a pre-experiment, temperature and the concentration of CO2 were monitored in 2–10 locations/office to evaluate the variation throughout the offices. A representative measurement point was subsequently selected and measurements of the same parameters were made during one week. All offices were monitored during the same week and occupant responses to the indoor environment were collected via the internet on the same day within that week. The temperature and the CO2 concentration varied more and were in some cases higher in the naturally ventilated buildings, but occupant responses in terms of symptoms and adverse perceptions differed only modestly between the two building types. Although rarely supported by statistical significance, the results indicated a somewhat higher degree of satisfaction with the indoor environment and a lower prevalence/intensity of symptoms among the occupants in the naturally ventilated buildings.  相似文献   

5.
The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial linear part of the concentration-response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR = 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR = 1.5). No single symptoms correlated with the potency of surface dust. The PD was not related to single building factors. The inflammatory PD may be used as an integrated proxy measure of biologically active compounds in dust, reflecting health relevant properties of the dust. PRACTICAL IMPLICATIONS: The potency of surface dust may be used as a crude measurement of the chemical and biological exposures present in the building, and being associated with the development of central nervous system symptoms. However, additional research is needed to establish the predictive value of the potency of surface dust.  相似文献   

6.
In the European research project OFFICAIR, a procedure was developed to determine associations between characteristics of European offices and health and comfort of office workers, through a checklist and a self‐administered questionnaire including environmental, physiological, psychological, and social aspects. This procedure was applied in 167 office buildings in eight European countries (Portugal, Spain, Italy, Greece, France, Hungary, the Netherlands, and Finland) during the winter of 2011–2012. About 26 735 survey invitation e‐mails were sent, and 7441 office workers were included in the survey. Among respondents who rated an overall comfort less than 4 (23%), ‘noise (other than from building systems)’, air ‘too dry’, and temperature ‘too variable’ were the main complaints selected. An increase of perceived control over indoor climate was positively associated with the perceived indoor environment quality. Almost one‐third of office workers suffered from dry eyes and headache in the last 4 weeks. Physical building characteristics were associated with occupants’ overall satisfaction (acoustical solutions, mold growth, complaints procedure, cleaning activities) and health (number of occupants, lack of operable windows, presence of carpet and cleaning activities). OFFICAIR project provides a useful database to identify stressors related to indoor environmental quality and office worker's health.  相似文献   

7.
Abstract Five floors of a 20-year old 6-story office building were investigated using an integrated step-by-step investigation strategy. This involved a walkthrough inspection, an occupant questionnaire, and targeted environmental monitoring of indoor air quality and comfort parameters. The initial questionnaire survey revealed a high occurrence of building-related symptoms. The walkthrough inspection and environmental monitoring identified deposits of surface dust (indoor surface pollution – ISP) on carpets and hard surfaces, and elevated levels of carbon dioxide and respirable suspended particulate matter (RSP) throughout the building. An intervention study (blinded to the occupants) was targeted at reducing ISP levels by replacing normal carpet cleaning practices with higher performance vacuum cleaners and improved cleaning practices. The intervention reduced ISP levels and significantly lowered RSP concentrations by approx. 80% from initial values and against control floors. A follow-up SBS questionnaire revealed significant reductions in all but two of the symptoms. The most significant reductions occurred with symptoms of eye irritation, throat irritation, dry unproductive cough, and nose irritation. The study showed that in older buildings with poor ventilation, a build-up of ISP, and elevated RSP levels, using higher performance carpet cleaning practices can reduce RSP to acceptable levels and can reduce SBS symptoms.  相似文献   

8.
The purpose of the study was to evaluate the impact of cleaning on indoor environment quality. Surface dust contamination and occupants' perception of the work environment factors and symptoms were the parameters studied. Six multi-floor office buildings were selected. Dust contamination on surfaces was sampled with gelatine foils and quantified using a BM-Dustdetector. Occupants' perceptions of the environment were assessed with modified MM-40 questionnaires. The results indicated that each building had its own surface dust contamination profile. Weekly cleaning maintained the surface dust contamination at the highest acceptable level for indoor environments. The occupants and their activities have a major effect on the level of dust particle contamination on desks. The correlation between the perceived surface dust contamination and the level of satisfaction with cleaning was as expected. Furthermore, surface dust contamination appeared not to be associated with work-related symptoms. PRACTICAL IMPLICATIONS: The results provide information about current program for contractors and clients, e.g. appropriate cleaning intervals of different surfaces, and the influence of disorder on result. After the evaluation of surface dust contamination levels, it will be possible for cleaning companies to focus on the most important surfaces to clean in order to enhance the quality of the indoor environment in office buildings. This should lead to future development work, which will require cooperation between contractors, clients, and research scientists. In office environments where high cleanliness is required, objective measurements (with instruments) are needed in addition to subjective measurements (the perceptions of occupants). It is essential to evaluate the efficiency of cleaning programs regularly with effective and appropriate quality-monitoring methods.  相似文献   

9.
Two large and detailed field studies of the effect of office environment parameters on aspects of environmental and job satisfaction were conducted. The first study focused on open-plan offices in nine conventional buildings, whereas the second encompassed open-plan and private offices in 24 buildings (12 green and 12 conventional). The data collection for these studies was separated by approximately a decade, but the data collection methods, contexts and analysis procedures were very similar. This offered the opportunity to compare the results of the studies at the workstation level, with the goal of identifying parameters consistent in affecting occupant satisfaction, and of exploring the effects of office type (open-plan versus private) and building type (green versus conventional). Satisfaction with acoustics and privacy was most strongly affected by workstation size and office type; satisfaction with lighting was most strongly affected by window access and glare conditions; and satisfaction with ventilation and temperature was most strongly affected by pollutant concentration. Occupants of green buildings rated all aspects of environmental satisfaction more highly. Finally, job satisfaction was most strongly affected by pollutant concentration and office type.  相似文献   

10.
Based on a database accumulated from several recent surveys of office buildings located in a temperate climate (Denmark), the effect on occupant perceptions and symptom prevalence was compared in buildings with natural and with mechanical ventilation in which earlier studies have shown a discrepancy in the degree of perceived control. The database was composed of 1272 responses obtained in 24 buildings of which 15 had mechanical ventilation (997 responses) and nine had natural ventilation (275 responses). The number of occupant-reported control opportunities was higher in buildings with natural ventilation. Analysis of occupant responses, after grouping according to categories determined by the degree of satisfaction with the perceived control, showed that it was more likely the degree of control satisfaction that affected the prevalence of adverse perceptions and symptoms. Thus, the degree of control, as perceived by occupants, seemed more important for the prevalence of adverse symptoms and building-related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow for fully automated IEQ control, such systems should not compromise occupants’ perception of having some degree of control of their indoor environment.  相似文献   

11.
Floor dust from nine city hall office buildings was separated into fiber and particulate fractions and analyzed for volatile organic compounds (VOCs) and total VOC (TVOC) by thermal desorption/high resolution gas chromatography (HRGC). Components were identified by HRGC/mass spectroscopy (MS). Principal component analysis was applied to VOC emission profiles revealing similarities between buildings and correlations between profiles and SBS symptoms of mucous membrane irritation and “concentration difficulty”. While the dominant pattern in emission profiles was not correlated with SBS irritation complaints, partial least squares analysis in latent variables (PLS analysis) identified VOCs for which peak areas were correlated with SBS irritation complaints and the CNS Complaint, “concentration difficulty”  相似文献   

12.
An intervention study was performed in a mechanically ventilated office building in which there were severe indoor climate complaints among the occupants. In one part of the building a new heating and ventilation strategy was implemented by renovating the HVAC system, and a carpet was replaced with a low-emitting vinyl floor material; the other part of the building was kept unchanged, serving as a control. A comprehensive indoor climate investigation was performed before and after the intervention. Over a 2-week period, the occupants completed a daily questionnaire regarding their comfort and health. Physiological examinations of eyes, nose and lungs were performed on each occupant. Physical, chemical and sensory measurements were performed before and after the intervention. The renewal of the flooring material was performed after a sensory test of alternative solutions in the laboratory. Before the floor material was installed in the office building, a full-scale exposure experiment was performed in the laboratory. The new ventilation strategy and renovation of the HVAC system were selected on the basis of laboratory experiments on a full-scale mock-up of a cellular office. The severity of occupants' environmental perceptions and symptoms was significantly reduced by the intervention.  相似文献   

13.
Abstract A European project started at the end of 1992, in which, in addition to current methods, trained sensory panels were used to investigate office buildings all over Europe. The main aim of this EC-Audit was to develop assessment procedures and guidance on ventilation and source control, to help optimize energy use in buildings while assuring good indoor air quality. In each of nine countries, six or more office buildings were selected. Measurements were performed at five selected locations in each building. The buildings were studied while normally occupied and ventilated to identify the pollution sources in the spaces and to quantify the total pollution load caused by the occupants and their activities, as well as the ventilation systems. The investigation included physical and chemical measurements, assessment of the perceived air quality in the spaces by a trained sensory panel, and measurement of the outdoor air supply to the spaces. A questionnaire for evaluating retrospective and immediate symptoms and perceptions was given to the occupants of the buildings. The building characteristics were described by use of a check-list. The annual energy consumption of the buildings and the weather conditions were registered. This paper presents results and conclusions of the audit in 56 buildings in Europe. However, the analysis and discussions of the results are a summary of the work done, and are focused mainly on comparison between sensory assessments and the other measurements performed. Furthermore, this paper brings the results of the study based on a two-factor analysis. A paper dealing with results on a multifactorial analysis is in preparation.  相似文献   

14.
Electric lighting consumes 19% of total electricity production worldwide. Open-plan offices constitute the majority of office stock, in which most office workers perform their daily tasks, and hence the lighting in those offices has significant impact on, not only energy usage, but also occupants’ productivity. This paper presents a unique lighting optimization approach for open-plan offices that is capable of tuning task lighting to each occupant's preference in the most energy-efficient fashion. Exploiting individual controllability of the advanced networked lighting systems, each luminaire can be dynamically actuated at a different level to realize various lighting configurations without any physical rewiring. This research formulates lighting actuation into a linear programming problem and finds the optimal light outputs for each of the luminaires that collaboratively deliver specified lighting to each workstation while using the least amount of energy. Simulations using our lighting optimization approach have shown its versatility in providing proper workstation-specific task lighting under different requirements compared to business-as-usual practices. Energy savings are generated from tuning the light levels to occupants’ needs as well as keeping unoccupied areas unlit or minimally lit with this approach.  相似文献   

15.
Leech JA  Raizenne M  Gusdorf J 《Indoor air》2004,14(3):169-173
A prospective telephone-administered questionnaire study in new home occupants compared general and respiratory health at occupancy and 1 year later in two groups. The test group or cases, was 52 R-2000(TM) homes (128 occupants) built to preset and certified criteria for energy efficient ventilation and construction practices. The control group were 53 new homes (149 occupants) built in the same year in the same geographic area and price range. Analyzed by household, case occupants' summative symptom scores improved significantly over the year of occupancy (Wilcoxon rank sum test, P < 0.006). Analysis of variance of individuals' total symptom scores showed a significant effect of the type of house (P < 0.0001), with lower change of scores in case buildings, but not of age or sex. In comparison with control homes, occupants of case homes reported more improvement in throat irritation (P < 0.004), cough (P < 0.002), fatigue (P < 0.009) and irritability (P < 0.002) with the main change in symptom category being from 'sometimes' to 'never'. Further extension of this pilot study is required to determine if these perceived health benefits are reproducible and/or relate to objective indoor air quality measures. PRACTICAL IMPLICATIONS: New occupants of energy efficient homes with heat recovery ventilators report improvement over 1 year in the symptoms of throat irritation, cough, fatigue, and irritability in comparison with control new home occupants. If this pilot study is reproducible and shown to relate to indoor air quality, prospective new home buyers may be interested in obtaining this health information prior to decision making.  相似文献   

16.
夏热冬暖地区绿色建筑性能后评估研究   总被引:1,自引:0,他引:1  
为了解夏热冬暖地区绿色建筑运行后实际能耗和室内环境品质,文章详细介绍了该气候区内绿色建筑主要技术的应用情况及应用效果。选取位于该气候区内共11个获得绿色建筑认证的办公建筑,通过调研实际能耗,结合用户主观问卷调研,与常规办公建筑的能耗和室内环境品质主观满意度进行了对比研究。结果表明,对于A类办公建筑,绿色建筑与常规建筑无明显差异,均略低于引导值;对于B类而言,绿色办公建筑的总能耗显著低于常规办公建筑,但与能耗指标相比二者能耗均较高,是建筑节能工作的重点。在室内环境品质满意度方面,用户对绿色建筑的满意度明显高于常规建筑,在空气品质和室内环境控制上尤为明显,光环境的差异则更多是归因于天然采光的设计,而非人工照明的优化。最后通过一个案例从节地、节能和室内环境等3个方面全面地介绍了适宜于夏热冬暖地区的绿色建筑设计。  相似文献   

17.
The study examined the effects of office space occupation, psychosocial work characteristics, and environmental satisfaction on physical and mental health of office workers in small‐sized and open‐plan offices as well as possible underlying mechanisms. Office space occupation was characterized as number of persons per one enclosed office space. A total of 207 office employees with similar jobs in offices with different space occupation were surveyed regarding their work situation (psychosocial work characteristics, satisfaction with privacy, acoustics, and control) and health (psychosomatic complaints, irritation, mental well‐being, and work ability). Binary logistic and linear regression analyses as well as bootstrapped mediation analyses were used to determine associations and underlying mechanisms. Employee health was significantly associated with all work characteristics. Psychosocial work stressors had the strongest relation to physical and mental health (OR range: 1.66–3.72). The effect of office space occupation on employee health was mediated by stressors and environmental satisfaction, but not by psychosocial work resources. As assumed by sociotechnical approaches, a higher number of persons per enclosed office space was associated with adverse health effects. However, the strongest associations were found with psychosocial work stressors. When revising office design, a holistic approach to work (re)design is needed.  相似文献   

18.
Recently, airtight envelope system has become popular in the design of office buildings to reduce heating and cooling loads. Maintaining allowable indoor air quality (IAQ) for such airtight buildings totally depends on mechanical ventilation systems. Subsequently, poor operation of the ventilation system in such office buildings causes ineffective removal of polluted indoor air, and displays a sign of “sick building syndrome” (SBS). User's perception is an important parameter for evaluating IAQ. A questionnaire study was carried out to investigate the prevalence of the SBS at a multistory centrally air-conditioned Airport Authority of India (AAI) building in the New Delhi city. Quantification of the perceptions of the users regarding IAQ was done by converting their responses to a SBS score. The quantified answers were then subjected to statistical analysis. Qualitative analysis of the questionnaire was carried out to evaluate relationships between SBS score and carbon dioxide (CO2) and other parameters related to building and work environment. Quantitative analysis of IAQ was also conducted by monitoring indoor concentrations of four pollutants, namely, nitrogen dioxide (NO2), sulphur dioxide (SO2), suspended particulate matter (SPM) and carbon monoxide (CO). Concentrations of pollutants were complying with IAQ standards as given by ASHRAE and WHO. The SBS was higher on the third floor as compared to other floors and the control tower. The main symptoms prevailing were headache (51%), lethargy (50%), and dryness in body mucous (33%). The third floor and the control tower were affected by infiltration, mainly from entrance doors. A direct relation between the average SBS score and CO2 concentration was found, i.e., the average SBS score increased with CO2 concentration and vice versa, clearly signifying the usefulness of SBS score in IAQ.  相似文献   

19.
Abstract Recent concern has centered on “sick buildings” in which there has been an unusually high percentage of health complaints by the building's occupants. Typically, these symptoms are thought to be tied to indoor air quality characteristics, such as high levels of respirable particles or volatiles, thermal conditions, etc. In addition, recent studies have drawn connections between “sick building syndrome” (SBS) symptoms and non-environmental variables, i.e., personal and occupational factors. This paper presents a brief review of a study by Hedge et al. (1995) and additional analyses of their data. In a study of 27 air-conditioned office buildings, Hedge et al. measured nine indoor environmental conditions at various locations within each building and concurrently questioned workers on sixteen SBS symptoms and a number of other personal factors. The additional analyses presented in this paper attempt to draw formal statistical connections between SBS symptoms and both personal worker characteristics and indoor air pollutants simultaneously. The analyses were based on symptom severity response variables whic include information not only on the frequency with which an individual experienced a symptom, but also on how much the symptom disrupted the individual's work. Results from sixteen linear mixed effects models indicate that significant predictors are primarily personal and occupational in nature rather than environmental. For a number of the symptoms, additional variability attributable to buildings exists. However, any physical explanation of this variability remains unclear.  相似文献   

20.
办公建筑照明节能设计探讨   总被引:1,自引:0,他引:1  
本文在对办公建筑照明节能问题进行分析的基础上,针对现代办公建筑中常见的开敞办公区域进行了照明节能设计,并重点对节能设计中的功率密度及照明控制方式进行了详细阐述;最后介绍了办公建筑电气照明节能设计要注意的其它问题。  相似文献   