1.
In recent years integrated models have been developed to simulate the entire urban wastewater system, including urban drainage systems, wastewater treatment plants, and receiving waterbodies. This paper uses such an integrated urban wastewater model to analyze the frequency of receiving water quality in an urban wastewater system with the aim of assessing the overall system performance during rainfall events. The receiving water quality is represented by two indicators: event mean dissolved oxygen (DO) concentration and event mean ammonium concentration. The compliance probability of the water quality indicators satisfying a specific threshold is used to represent the system performance, and is derived using the rainfall events from a series of 10 years' rainfall data. A strong correlation between the depth of each rainfall event and the associated volume of combined sewer overflow (CSO) discharges is revealed for the case study catchment, while there is a low correlation between the intensity/duration of the rainfall event and the volume of the CSO discharges. The frequency analysis results obtained suggest that the event mean DO and ammonium concentrations have very different characteristics in terms of compliance probabilities at two discharging points for CSO and wastewater treatment plant effluent, respectively. In general, the simulation results provide an understanding of the performance of the integrated urban wastewater system and can provide useful information to support water quality management.  相似文献   

2.
Assessments of sewer performance are usually based on a single computation of CSO (combined sewer overflow) volumes using a time series of rainfall as system loads. A shortcoming of this method is that uncertainties in knowledge of sewer system dimensions are not taken into account. Moreover, sewer models are rarely calibrated. This paper presents the impacts of database errors and model calibration on return periods of calculated CSO volumes. The impact of uncertainties is illustrated with two examples. Variability of calculated CSO volumes is estimated using Monte Carlo simulations. The results show that calculated CSO volumes vary considerably due to database errors, especially uncertain dimensions of the catchment area. Furthermore, event-based calibration of a sewer model does not result in more reliable predictions because the calibrated parameters have low portability. However, it enables removal of database errors harmonising model predictions and 'reality'.  相似文献   

3.
To reduce the CSO (Combined Sewer Overflow) pollutant discharge, one of the effective options is cleaning of sewer pipes before rainfall events. To maximize the efficiency, identification of pipes to be cleaned is necessary. In this study, we discussed the location of pipe deposit in dry weather in a combined sewer system using a distributed model and investigated the effect of pipe cleaning to reduce the pollutant load from the CSO. First we simulated the dry weather flow in a combined sewer system. The pipe deposit distribution in the network was estimated after 3 days of dry weather period. Several specific pipes with structural defect and upper end pipes tend to have an accumulation of deposit. Wet weather simulations were conducted with and without pipe cleaning in rainfall events with different patterns. The SS loads in CSO with and without the pipe cleaning were compared. The difference in the estimated loads was interpreted as the contribution of wash-off in the cleaned pipe. The effect of pipe cleaning on reduction of the CSO pollutant load was quantitatively evaluated (e.g. the cleaning of one specific pipe could reduce 22% of total CSO load). The CSO simulations containing pipe cleaning options revealed that identification of pipes with accumulated deposit using the distributed model is very useful and informative to evaluate the applicability of pipe cleaning option for CSO pollutant reduction.  相似文献   

4.
CSO emission is widely considered a significant pollution source to receiving waters in urban areas. The existing deterministic sewer models are not able to predict CSO emission effectively. In this study, a conceptual CSO emission model SEWSIM has been developed using a powerful programming package MATLAB and SIMULINK. A sewer system consisting of an impervious catchment and a sewer network is schematised as two linear dynamic reservoirs. The following physical processes are conceptually modelled: rainfall-runoff; surface solids buildup and washoff; sewer sediment erosion and deposition. The model is suitable for both event-based and continuous simulations. Some simulation results demonstrate that SEWSIM predicts pollution load of CSO emission more effectively than deterministic models.  相似文献   

5.
Tokyo Metropolitan government has decided to make the maximum possible use of the existing facilities while ensuring safety against inundation and to promote measures also from a software approach by introducing a system capable of minimizing combined sewer overflow, the real-time control system (RTC). A pilot RTC system was installed in August 2002 for the Shinozaki Pumping Station. The RTC system monitors the precipitation volume and the water level in the pipe. Simulations were carried out on the basis of these data. From the results, it was found that with the use of the RTC it is possible to reduce CSO by roughly 50% for small rainfalls with a total precipitation level of 20 mm or less by strong rainwater in the pipe routes at the beginning of the rain. It has also been shown that CSO can be reduced by about 80% through the use of rainfall forecasting.  相似文献   

6.
Tipping bucket rain gauges (TBR) are widely used in urban hydrology. The present study investigated the uncertainties in recorded rainfall intensity induced by the following properties of the TBR: depth resolution i.e. the bucket volume, calibration parameters, wetting and evaporation losses and the method of data recording (time between tips or tips per minute). The errors were analysed by means of a TBR simulator i.e. a simulation program that models the behaviour of a TBR. Rainfall data disaggregated to 6 seconds from measured 1-min data and randomly varied were taken as input to the simulator. Different TBR data series were produced by changing the properties of the simulated rain gauge. These data series together with the original rainfall events were used as input to a rainfall-runoff model. Computed overflow volume and peak discharge from a combined sewer overflow (CSO) weir were compared. Errors due to depth resolution (i.e. the bucket size) proved to be small. Therefore TBRs with a depth resolution up to 0.254 mm can be used in urban hydrology without inducing significant errors. Wetting and evaporation losses caused small errors. The method of data recording had also little influence. For larger bucket volumes variable time step recording induced smaller errors than tips per minute recording.  相似文献   

7.
Constructed wetlands (CWs) have proved to be a highly effective measure to reduce the ecological impact of combined sewer overflows (CSOs) on receiving waters. Due to the stochastic nature of the loading regime and the multitude of environmental influences, assessment of the performance of such plants requires detailed mathematical modelling. A multi-component reactive transport module (CW2D) was applied to simulate the flow, transport and degradation processes occurring in a CW for CSO treatment. CW2D was originally developed to simulate the treatment of municipal wastewater in subsurface flow CWs. Loading and operational conditions in CSO treatment differ fundamentally from the conditions occurring for wastewater treatment. Despite these differences, first results from the simulation of lab-scale experiments show, that the model is generally applicable to this type of plant. Modelling of adsorption, degradation processes, and influent fractionation, however, require further research.  相似文献   

8.
When looking at acute receiving water impacts due to combined sewer overflows the characteristics of the background diurnal sewage flux variation may influence the peak loads from combined sewer overflows (CSO) and wastewater treatment plant (WWTP) effluent significantly. In this paper, effects on the dynamic compounds transported in the sewer, on CSO discharges and WWTP loading are evaluated by means of hydrodynamic simulations. The simulations are based on different scenarios for diurnal dry-weather flow variations induced by different infiltration rates.  相似文献   

9.
The streamflow series for the upstream basin of the Senegal River is marked by considerable gaps. The objective of this article is to simulate and extend hydrological data, using the GR2M rainfall-runoff model. A sensitivity analysis of the model to rainfall and water holding capacity input data was performed. This analysis was performed after calculating catchment rainfall, mean potential evapotranspiration, and maximum, minimum and mean water holding capacity. The best combination of input data was chosen by catchment based on the Nash-Sutcliffe criterion. Then cross calibration-validation tests were performed, using the selected input data to choose model parameter sets.  相似文献   

10.
11.
12.
Since treatment plants have been built all over Germany during the last decades, the water quality of receiving streams has been improved remarkably. But there are still a lot of quality problems left, which are caused e.g. by combined sewer overflows (CSO), treatment plant effluents or rainwater discharges from separate sewer systems. At present different efforts are undertaken to control sewer systems in order to improve the operation of urban drainage systems or more generally, design processes. The Emschergenossenschaft and Lippeverband (EG/LV) are carrying out research studies, which are focusing on a minimization of total emissions from sewer systems both from wastewater treatment plant (WWTP) effluents and from CSO. They consider dynamic interactions between rainfall, resultant wastewater, combined sewers, WWTP and receiving streams. Therefore, in an advanced wastewater treatment, a model-based improvement of WWTP operation becomes more and more essential, and consequently a highly qualified operational staff is needed. Some aspects of the current research studies are presented in this report. The need and the use of an integrated approach to combine existing model components in order to optimize dynamic management of combined sewer systems (CSS) with a benefit for nature are outlined.  相似文献   

13.
Discharges of combined sewer overflows (CSOs) and stormwater are recognized as an important source of environmental contamination. However, the harsh sewer environment and particular hydraulic conditions during rain events reduce the reliability of traditional flow measurement probes. An in situ system for sewer water flow monitoring based on video images was evaluated. Algorithms to determine water velocities were developed based on image-processing techniques. The image-based water velocity algorithm identifies surface features and measures their positions with respect to real world coordinates. A web-based user interface and a three-tier system architecture enable remote configuration of the cameras and the image-processing algorithms in order to calculate automatically flow velocity on-line. Results of investigations conducted in a CSO are presented. The system was found to measure reliably water velocities, thereby providing the means to understand particular hydraulic behaviors.  相似文献   

14.
Generally, studies investigating the treatment efficiency of tank structures for storm water or waste water treatment observe pollutant flows in connection with conditions of hydraulic loading. Further investigations evaluate internal processes in tank structures using computational fluid dynamic (CFD) modelling or lab scale tests. As flow paths inside of tank structures have a considerable influence on the treatment efficiency, flow velocity profile (FVP) measurements can provide a possibility to calibrate CFD models and contribute to a better understanding of pollutant transport processes in these structures. This study focuses on tests carried out with the prototype FVP measurement device OCM Pro LR by NIVUS in a sedimentation tank with combined sewer overflow (CSO) situated in Petange, Luxembourg. The OCM Pro LR measurement system analyses the echo of ultrasonic signals of different flow depths to get a detailed FVP. A comparison of flow velocity measured by OCM Pro LR with a vane measurement showed good conformity. The FVPs measured by OCM Pro LR point out shortcut flows within the tank structure during CSO events, which could cause a reduction of the cleaning efficiency of the structure. The results prove the applicability of FVP measurements in large-scale structures.  相似文献   

15.
The design of the urban sewage system is site specific, and it makes the use of three-dimensional (3D) model an alternative to a field study or a laboratory experiment. However, the use of 3D computational fluid dynamics (CFD) in the study of the urban sewage system has been generally limited to the study of a single structural component with simplified assumptions. In this study, the 3D model that adopted the renormalized group (RNG) k-ε turbulence model, the volume of fluid (VOF) free water surface model and the particle tracking approach was verified comparing the predicted flow field data with the measurements in laboratory scale experiments. Then, the model was applied to optimize the design of the combined sewer system (CSS) in the city of Edmonton with multiple hydraulic structures. Considering the details of predicted flow characteristics and the behaviors of the suspended solids, the final design was chosen and implemented to reduce the water pollution induced by the direct combined sewer overflow (CSO) discharge to the receiving water body. It is shown that the proposed 3D CFD modeling approach is a cost-effective tool to design the municipal sewer system.  相似文献   

16.
17.
Different approaches for quantification of pollution loads discharged from combined sewer networks into surface water bodies have been observed over the last few years and decades, but a large number of unresolved problems still remain. Many monitoring campaigns have been based on manual or automated spot sampling - with the long known limitations of this method such as sampling errors and errors due to sample conservation, transport and preparation. On the other hand, only recently have sensors became available which are suitable for continuous application in sewer networks. A large number of practical problems still have to be solved before continuous monitoring in sewer networks will be successful. Additionally, most of the applicable sensors are based on surrogate methods which results in a considerable effort for reference measurements for sensor calibration. Finally, it has to be considered that, depending on the sewer network topography, deposition and remobilisation of pollutants varies considerably, which limits the generality of monitoring results and, subsequently, their applicability as a base for the design of storm water tanks or combined sewer overflows (CSO). A monitoring station for continuous monitoring of load discharges from a CSO has been installed and operated for more than one year. The design and equipment of the measurement station, operational experiences and results are given in this paper.  相似文献   

18.
Increasing concern over the discharge of sewer solids from combined sewer overflows (CSOs) has encouraged the introduction of installations which incorporate either mesh or bar screen arrangements, or both. Gross solids create visual and aesthetic pollution if they reach watercourses. An entirely new arrangement for a CSO with a perforated screen of 6 mm diameter apertures is described in the paper. The arrangement is circular, with tangential flow across the screen to facilitate its cleaning. High velocities across the screen holes ensure that solids which have been prevented from discharging are swept clear from the screen. As a result, a sufficient screen area remains free from trapped solids to permit discharge of flow. The device has been designed to meet all anticipated performance criteria for the removal of solids, and to require a minimum of maintenance.A thorough testing programme in different conditions is described. Laboratory testing utilised a wide range of gross solids and flows to determine efficiencies of solids removal under all anticipated operating conditions. The performance of the CSO in a sewer environment was evaluated at a sewage treatment works with flows up to 1801/s using both raw and treated sewage to simulate storm sewage of different strengths. Both the device and its testing are described, together with the results of the testing programme.  相似文献   

19.
An Use Attainability Analysis (UAA) has been initiated to evaluate what water-quality standards can be achieved in the Chicago Waterway System (CWS). There are nearly 200 combined sewer overflow (CSO) locations discharging to the CWS by gravity. Three CSO pumping stations also drain approximately 140 km2. Because of the dynamic nature of the CWS the DUFLOW model that is capable of simulating hydraulics and water-quality processes under unsteady-flow conditions was used to evaluate the effectiveness of water-quality improvement techniques identified by the UAA including CSO treatment. Several CSO treatment levels were applied at gravity flow CSOs to evaluate improvement in dissolved oxygen (DO). The results show that pollutant removal at CSOs improves DO to a certain degree, but it still was not sufficient to bring DO concentrations to 5 mg/L or higher for 90% of the time during wet weather at most locations on the CWS. Flow from the pumping stations results in substantial stress on DO since a huge amount of un-treated water with a high pollution load is discharged into the CWS in a short period of time at a certain location. The simulation results indicate that CSO treatment does not effectively improve DO during wet-weather periods on the CWS.  相似文献   

20.
针对合流制管网系统在雨天溢流污染严重,造成城市水体黑臭现象的问题,以银川市某高密度城区合流制管网系统为例,基于SWMM模型,在短历时设计降雨和长历时设计降雨两种条件下,模拟分析了合流制溢流(CSO)调蓄池、雨污管道混错接改造、绿化带海绵化改造等“灰绿”协同措施对CSO污染的影响。结果表明:CSO调蓄池、雨污管道混错接改造、绿化带海绵化改造及“灰绿”措施结合4种方案在短历时、长历时设计降雨条件下,随着降水量的增加,溢流水量及溢流污染物负荷均增加,溢流削减率均逐渐减小,其中“灰绿”措施结合方案对溢流污染的削减效果最为显著;重现期小于5 a时,溢流水量削减率与溢流污染物负荷削减率基本达到80%;降雨条件为中雨时,污染物负荷削减率基本达到75%;重现期为20 a时,溢流水量削减率及TSS、COD、TP、NH^(+)_(4)-N负荷削减率分别达到64%、70%、70%、70%、70%;降雨条件为大雨时,溢流水量削减率及TSS、COD、TP、NH^(+)_(4)-N负荷削减率分别达到28%、32%、26%、31%、33%。  相似文献   