首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
We present a disposable system for recording neurotransmitter release from individual cells in vitro. A simple yet reliable microelectrode fabrication process is introduced using screen-printed carbon paste. It allows rapid fabrication of devices at low costs without standard clean-room technology. We demonstrate functionality of the system by real-time observation of vesicle release from single PC12 (rat pheochromocytoma) cells. The cells are cultured directly on the chip and can be used for immediate or long-term in vitro experiments. Thus, our approach may serve as a platform for pharmacological cell culture studies.  相似文献   

3.
Zhang X  Sun F  Peng X  Jin W 《Analytical chemistry》2007,79(3):1256-1261
An electrochemical method for quantitative determination of enzyme activity in single cells was developed by scanning a microelectrode (ME) over a nitrocellulose film-covered microreactor with micropores by means of a scanning electrochemical microscope (SECM). Peroxidase (PO) in neutrophils was chosen as the model system. The microreactor consisted of a microwell with a solution and a nitrocellulose film with micropores. A single cell perforated by digitonin was injected into the microwell. After the perforated cell was lysed and allowed to dry, physiological buffer saline (PBS) containing hydroquinone (H2Q) and H2O2 as substrates of the enzyme-catalyzed reaction was added in the microwell. The microwell containing the extract of the lysed cell and the enzyme substrates was covered with Parafilm to prevent evaporation. The solution in the microwell was incubated for 20 min. In this case, the released PO from the cell converted H2Q into benzoquinone (BQ). Then, the Parafilm was replaced by a nitrocellulose film with micropores to fabricate the microreactor. The microreactor was placed in an electrochemical cell containing PBS, H2Q, and H2O2. After a 10-microm-radius Au ME was inserted into the electrochemical cell and approached down to the microreactor, the ME was scanned along the central line across the microreactor by means of a SECM. The scan curve with a peak was obtained by detecting BQ that diffused out from the microreactor through the micropores on the nitrocellulose film. PO activity could be quantified on the basis of the peak current on the scan curve using a calibration curve. This method had two obvious advantages: no electrode fouling and no oxygen interference.  相似文献   

4.
Interest in elucidating the mechanisms of action of various classes of anticancer agents and exploring the pathways of the induced-nitric oxide (NO) release provides an impetus to conceive a better designed approach to locally detect NO in tumors, in vivo. We report here on the first use of an electrochemical sensor that allows the in vivo detection of NO in tumor-bearing mice. In a first step, we performed the electrochemical characterization of a stable electroactive probe, K4Fe(CN)6, directly injected into the liquid microenvironment especially created around the electrode in the tumor. Second, the ability of the inserted electrode system to detect the presence of NO itself in the tumoral tissue was achieved by using the chemically modified Pt/Ir electrode as NO sensor and two NO donor molecules: diethylammonium (Z)-1-(N,N-diethylamino)diazen-1-ium 1,2-diolate (DEA-NONOate) and (Z)-1-[N-(2-aminopropyl)-N-(2-ammonio propyl)amino]diazen-1-ium 1,2-diolate (PAPA-NONOate). These two NO donor molecules allowed proving the electrochemical detection of (i) directly injected exogenous NO phosphate buffer solution into the tumor (decomposed DEA-NONOate) and (ii) biomimetically induced endogeneous release of NO in the tumoral tissue, upon injection of PAPA-NONOate into the tumor. This approach could be applied to the in vivo study of candidate anticancer drugs acting on the NO pathways.  相似文献   

5.
Lee Y  Kim J 《Analytical chemistry》2007,79(20):7669-7675
A planar-type amperometric dual microsensor for simultaneous detection of nitric oxide and carbon monoxide is presented. The sensor consists of a dual platinum microdisk-based working electrode (WE) and a Ag/AgCl counter/reference electrode covered with an expanded poly(tetrafluoroethylene) (Tetra-tex) gas-permeable membrane. The dual WE possesses two different platinized platinum disks (WE1 and WE2, 250 and 25 microm in diameter, respectively). The larger WE1 is further modified with electrochemical deposition of tin. Use of two sensing disks different in their size as well as in their surface modification produces apparently different sensitivity ratios of NO to CO at WE1 and at WE2 (approximately 2 and approximately 10, respectively) that are induced by favorable CO oxidation on the surface of tin versus platinum. Anodic currents independently measured at WE1 and at WE2 are successfully converted to the concentrations of NO and CO in the co-presence of these gases using the differentiated sensitivities at each electrode. The sensor is evaluated in terms of its analytical performance: respectable linear dynamic range (sub nM to microM); low detection limit (approximately 1 nM for NO and <5 nM for CO); selectivity (over nitrite up to approximately 1 mM); and sensitivity (sufficient for analyzing physiological levels of NO and CO). Using the NO/CO dual microsensor, real-time, simultaneous, direct, and quantitative measurements of NO and CO generated from living biological tissue (mouse, c57, kidney) surfaces, for the first time, are reported.  相似文献   

6.
Electrochemical microelectrodes are commonly used to detect spikes of amperometric current that correspond to exocytosis of oxidizable transmitter from individual vesicles, i.e., quantal exocytosis. We are developing transparent multielectrochemical electrode arrays on microchips in order to automate measurement of quantal exocytosis. Here, we report development of an improved device to target individual cells to each microelectrode in an array. Efficient targeting (~75%) is achieved using cell-sized microwell traps fabricated in SU-8 photoresist together with patterning of poly(l-lysine) in register with electrodes to promote cell adhesion. The surface between electrodes is made resistant to cell adhesion using poly(ethylene glycol) in order to facilitate movement of cells to electrode "docking sites". We demonstrate the activity of the electrodes using the test analyte ferricyanide and perform recordings of quantal exocytosis from bovine adrenal chromaffin cells on the device. Multiple cell recordings on a single device demonstrate the consistency of spike measurements, and multiple recordings from the same electrodes demonstrate that the device can be cleaned and reused without degradation of performance. The new device will enable high-throughput studies of quantal exocytosis and may also find application in rapidly screening drugs or toxins for effects on exocytosis.  相似文献   

7.
Highly boron-doped diamond microelectrodes were employed in an end-column electrochemical detector for capillary electrophoresis (CE). The diamond microline electrodes were fabricated from conducting diamond thin films (exposed surface area, 300 x 50 microm), and their analytical performance as CE detectors was evaluated in a laboratory-made CE installation. The CE-ED system exhibited high separation efficiency for the detection of several catecholamines, including dopamine (DA), norepinephrine (NE), and epinephrine (E), with excellent analytical performance, for example, 155,000 theoretical plates for DA. The diamond-based electrochemical detection system also displayed low detection limits (approximately 20 nM for E at S/N = 3) and a highly reproducible current response with 10 repetitive injections of mixed analytes containing DA, NE, and E (each 50 microM), with relative standard deviations (RSD) of approximately 5%. The performance of the diamond detector in CE was also evaluated in the detection of chlorinated phenols (CP). When compared to the carbon fiber microelectrode, the diamond electrode exhibited lower detection limits in an end-column CE detection resulting from very low noise levels and highly reproducible analyses without electrode polishing due to analyte fouling, which makes it possible to perform easier and more stable CE analysis.  相似文献   

8.
An indirect method for monitoring nitric oxide (NO) by determining nitrate and nitrite using microchip capillary electrophoresis (CE) with electrochemical (EC) detection has been developed. This method combines determination of nitrite by direct amperometric detection following a microchip-based CE separation and conversion of nitrate to nitrite by chemical reduction using Cu-coated Cd granules. The amount of nitrate is quantified by calculating the difference in the amount of nitrite in the sample before and after the reduction of nitrate. Optimization of the separation, injection, detection, and reduction reaction conditions, as well as studies involving integration of the reduction reaction onto the microchip, are described. It was found that nitrite can be separated and detected in approximately 45 s by microchip CEEC. The reduction reaction was successfully integrated on-chip and carried out in approximately 1 min following activation of the Cd granules. The usefulness of this device was demonstrated by monitoring the amount of nitrate and nitrite produced from 3-morpholinosydnonimine, a NO-releasing compound.  相似文献   

9.
A novel approach for micropatterning of surfaces with organic and biological microstructures using the scanning electrochemical microscope (SECM) is described. The approach is based on the introduction of the spatial resolution by local deposition of gold particles followed by monolayer formation and functionalization. Specifically, gold patterns were deposited locally on silicon wafers with the SECM as a result of the controlled anodic dissolution of a gold microelectrode. The gold patterns were further used as microsubstrates for assembling cystamine monolayers to which either fluoresceine isothiocyanate (FIT) or glucose oxidase (GOD) were covalently attached. Characterization of the organic monolayers, as well as the biological activity of the enzyme patterns, was carried out by fluorescence microscopy and the SECM, respectively.  相似文献   

10.
Yan J  Du Y  Liu J  Cao W  Sun X  Zhou W  Yang X  Wang E 《Analytical chemistry》2003,75(20):5406-5412
A new method for the fabrication of an integrated microelectrode for electrochemical detection (ECD) on an electrophoresis microchip is described. The pattern of the microelectrode was directly made on the surface of a microscope slide through an electroless deposition procedure. The surface of the slide was first selectively coated with a thin layer of sodium silicate through a micromolding in capillary technique provided by a poly(dimethylsiloxane) (PDMS) microchannel; this left a rough patterned area for the anchoring of catalytic particles. A metal layer was deposited on the pattern guided by these catalytic particles and was used as the working electrode. Factors influencing the fabrication procedure were discussed. The whole chip was built by reversibly sealing the slide to another PDMS layer with electrophoresis microchannels at room temperature. This approach eliminates the need of clean room facilities and expensive apparatus such as for vacuum deposition or sputtering and makes it possible to produce patterned electrodes suitable for ECD on microchip under ordinary chemistry laboratory conditions. Also once the micropattern is ready, it allows the researchers to rebuild the electrode in a short period of time when an electrode failure occurs. Copper and gold microelectrodes were fabricated by this technique. Glucose, dopamine, and catechol as model analytes were tested.  相似文献   

11.
The electrochemistry of 50 μm diameter Pt electrodes used for neural stimulation was studied in vitro by reciprocal derivative chronopotentiometry. This differential method provides well-defined electrochemical signatures of the various polarization phenomena that occur at Pt microelectrodes and are generally obscured in voltage transients. In combination with a novel in situ coulometric approach, irreversible H(2) and O(2) evolution, Pt dissolution and reduction of dissolved O(2) were detected. Measurements were performed with biphasic, charge-balanced, cathodic-first and anodic-first current pulses at charge densities ranging from 0.07 to 1.41 mC/cm(2) (real surface area) in phosphate buffered saline (PBS) with and without bovine serum albumin (BSA). The extent to which O(2) reduction occurs under the different stimulation conditions was compared in O(2)-saturated and deoxygenated PBS. Adsorption of BSA inhibited Pt dissolution as well as Pt oxidation and oxide reduction by blocking reactive sites on the electrode surface. This inhibitory effect promoted the onset of irreversible H(2) and O(2) evolution, which occurred at lower charge densities than those in PBS. Reduction of dissolved O(2) on Pt electrodes accounted for 19-34% of the total injected charge in O(2)-saturated PBS, while a contribution of 0.4-12% was estimated for in vivo stimulation. These result may prove important for the interpretation of histological damage induced by neural stimulation and therefore help define safer operational limits.  相似文献   

12.
Scanning electrochemical microscopy (SECM) has been used to detect and visualize the local electrocatalytic activity of dimensionally stable anodes (DSA) for Cl(2) evolution from brine. The sample generation-tip collection (SG-TC) mode of SECM shows limitations arising from complications connected with the reduction of Cl(2) at the SECM tip due to the presence of a significant amount of nondissolved Cl(2) gas. Because only dissolved Cl(2) can be electrochemically reduced at the tip, a large amount of the Cl(2) gas which is produced at active spots of the DSA is not detected. Additionally, a decrease of the cathodic current at the tip may occur owing to the adhesion of gas bubbles and blocking of the electrode surface. To overcome this limitation, the redox competition mode of SECM was extended and applied to the local visualization of Cl(2) evolution from highly concentrated brine solutions. High concentrations of Cl(2) produced at the sample can cause inhibition of the same reaction at the tip by accumulation of Cl(2) in the proximity of the SECM tip. In this way the tip current is decreased, which can be used as a measure for the catalytic activity of the sample underneath the tip.  相似文献   

13.
A method is proposed for calibrating a scanning electron microscope that enables one to use a linear measure with a single certified dimension to determine all the basic parameters needed for making linear measurements: image magnification, electron-probe diameter, and correction parameter for deriving the true dimensions of relief elements from the distance between video-signal maxima.Translated from Izmeritel'naya Tekhnika, No. 7, pp. 68–70, July, 1994.  相似文献   

14.
徐峥  段俊丽  钱梦騄  程茜 《声学技术》2016,35(3):239-242
血管内皮细胞的功能与许多疾病间存在关联,但现在对其功能好坏的定量描述仍十分少见。该文以内皮细胞的弹性作为衡量其功能的一个标准。通过理论建立压痕测量杨氏模量的计算方法,并利用扫描探针显微镜从实验上得到了正常及过氧化氢处理过的人脐静脉内皮细胞的杨氏模量。发现过氧化氢处理后细胞的杨氏模量升高,表明通过杨氏模量来表征细胞活性是可行的。  相似文献   

15.
We report the formation of solid-state nanopores using a scanning helium ion microscope. The fabrication process offers the advantage of high sample throughput along with fine control over nanopore dimensions, producing single pores with diameters below 4 nm. Electronic noise associated with ion transport through the resultant pores is found to be comparable with levels measured on devices made with the established technique of transmission electron microscope milling. We demonstrate the utility of our nanopores for biomolecular analysis by measuring the passage of double-strand DNA.  相似文献   

16.
To detect the target molecules, aptamers are currently focused on and the use of aptamers for biosensing is particularly interesting, as aptamers could substitute antibodies in bioanalytical sensing. So this paper describes the novel electrochemical system for protein in sandwich manner by using the aptamers and the scanning electrochemical microscope (SECM). For protein detection, sandwich system is ideal since labeling of the target protein is not necessary. To develop the electrochemical protein sensor system, thrombin was chosen as a target protein since many aptamers for it were already reported and two different aptamers, which recognize different positions of thrombin, were chosen to construct sandwich type sensing system. In order to obtain the electrochemical signal, the glucose oxidase (GOD) used for labeling the detection aptamers since it has large amount of stability in aqueous solution. One aptamer was immobilized onto the gold electrode and the other aptamer for detection was labeled with GOD for generation of the electric signal. Thrombin was detected in sandwich manner with aptamer immobilized onto the gold electrode and the GOD labeled aptamer. The enzymatic signal, generated from glucose addition after the formation of the complex of thrombin, was measured. The generation-collection mode of SECM was used for amperometric H2O2 detection.  相似文献   

17.
Microelectrodes, printed as an array on the surface of a silicon chip, generate chemically active species in a solution of electrolyte held between the electrode array and a glass plate. The active species induce chemical change in molecules coupled to the surface of the glass plate, which is separated from the electrode array by a gap of several micrometers. This paper explores the nature and pattern of the induced chemical change. The patterning is discussed with respect to the electrolyte composition and the magnitude and duration of current applied to the microelectrodes. We show that under suitable conditions the active species is confined to micrometer-sized features and diffusion does not obscure the surface pattern produced.  相似文献   

18.
The incorporation of platinum disk microelectrodes of various radii (2.5-50 microns) in a well-jet flow cell offers reduced limits of detection for the determination of copper in urine by flow injection analysis compared with standard methods based on a conventional sized glassy carbon disk macroelectrode (radius 1.5 mm), in a thin-layer cell. The radius of the platinum disk microelectrode was found to be critical with respect to both the limit of detection and flow rate dependence. An optimal radius value of 28 microns was found with detection limits increasing with both larger and smaller electrode radii. In contrast, as theoretically expected, a diminished flow rate dependence was observed the smaller the radii of the platinum disk microelectrodes. Sample cleanup and preparation is conveniently achieved by the use of Sep-Pak cartridges and formation of a copper dithiocarbamate complex. The metal complex is easily oxidized at platinum disk microelectrodes in acetonitrile, which was the solvent used in the flow injection method of analysis.  相似文献   

19.
We have developed glucose and lactate ultramicroelectrode (UME) biosensors based on glucose oxidase and lactate oxidase (with enzymes immobilized onto Pt UMEs by either electropolymerization or casting) for scanning electrochemical microscopy (SECM) and have determined their sensitivity to glucose and lactate, respectively. The results of our evaluations reveal different advantages for sensors constructed by each method: improved sensitivity and shorter manufacturing time for hand-casting, and increased reproducibility for electropolymerization. We have acquired amperometric approach curves (ACs) for each type of manufactured biosensor UME, and these ACs can be used as a means of positioning the UME above a substrate at a known distance. We have used the glucose biosensor UMEs to record profiles of glucose uptake above individual fibroblasts. Likewise, we have employed the lactate biosensor UMEs for recording the lactate production above single cancer cells with the SECM. We also show that oxygen respiration profiles for single cancer cells do not mimic cell topography, but are rather more convoluted, with a higher respiration activity observed at the points where the cell touches the Petri dish. These UME biosensors, along with the application of others already described in the literature, could prove to be powerful tools for mapping metabolic analytes, such as glucose, lactate, and oxygen, in single cancer cells.  相似文献   

20.
A nanocomposite of graphene oxide and gold nanourchins has been used here to modify the surface of a screen‐printed carbon electrode to enhance the sensitivity of the electrochemical DNA detection system. A specific single‐stranded DNA probe was designed based on the target DNA sequence and was thiolated to be self‐assembled on the surface of the gold nanourchins placed on the modified electrode. Doxorubicin was used as an electrochemical label to detect the DNA hybridisation using differential pulse voltammetry (DPV). The assembling process was confirmed using scanning electron microscopy (SEM) imaging, cyclic voltammetry (CV), and the EIS method. The high sensitivity of the proposed system led to a low detection limit of 0.16 fM and a wide linear range from 0.5 to 950.0 fM. The specificity of the DNA hybridisation and the signalling molecule (haematoxylin) caused very high selectivity towards the target DNA than other non‐specific sequences.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号