首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The current best option to upgrade constructed wetlands (CWs) for phosphorus (P) retention, in terms of efficiency, cost and simplicity, consists in using media having a strong P affinity. The media can be used either in the planted beds or in a filtration system downstream of the beds. The use of slag filters was shown to be efficient for removing P from wastewater as it represented a slow release source of calcium and hydroxide, favouring the formation of hydroxyapatite. Our study aimed at maximising the P retention capacity of slag filters located at the outlet of CWs since electric arc furnace slag has been shown to inhibit the growth of macrophytes when used in the filtration matrix. Bench-scale columns (Vtot = 6.2 L) filled with various combinations of filter media (slag, granite, limestone) of different sizes (2-5, 5-10, 10-20 mm) were fed on-site during four months with a CW effluent (in mg/L: 30 COD, 30 TSS, 10 Pt). Results showed that the best media combination enabling the maximum o-PO4 retention (more than 80% removal without clogging) consisted in a series of a ternary mix column (slag 5-10 mm, granite 2-5 mm, limestone 5-10 mm) followed by a slag column (slag 5-10 mm). Pilot scale columns (Vtot = 300 L), filled with the best media combination, were installed at the outlet of a 28 m2 CW. These columns showed more than 75% removal efficiency during one year and were designed to be easily replaced each year.  相似文献   

2.
A kind of electric arc furnace (EAF) steel slag was phosphated, and its isothermal and dynamic adsorptions of copper, cadmium, and lead ions were measured to determine if heavy metal adsorption changes after phosphorus adsorption. The surface area increased greatly after the slag was phosphated. Isothermal adsorption experiments showed that the theoretical Q(max) of the EAF steel slag on Cu(2+), Cd(2+), and Pb(2+) improved 59, 50, and 89% respectively after it was phosphated. Dynamic adsorption results showed that the greatest adsorption capacities of unit volume of Cu(2+), Cd(2+), and Pb(2+) were 2.2, 1.8, and 1.8 times that of the column packed with original EAF steel slag when the column was packed with phosphate EAF steel slag at the same heavy metal ion concentration. The breakthrough time, the exhaustion time and elution efficiency of the column also increased when the column was packed with phosphated EAF steel slag compared with that packed with original EAF steel slag. Phosphorus adsorption could further improve the heavy metal ion adsorption of the EAF steel slag.  相似文献   

3.
Wu J  He F  Xu D  Wang R  Zhang X  Xiao E  Wu Z 《Water science and technology》2011,63(11):2719-2724
This research aimed to investigate the phosphorus (P) removal of a series of laboratory-scale unvegetated vertical-flow constructed wetland systems using anthracite, steel slag and related blends as substrate in treatment of low concentration domestic sewage. The long-term performance of P removal was firstly studied by using single substrate of anthracite or steel slag, and three systems applying various combined substrates were investigated when the average P loading rate varied between 0.9 and 1.5 g TP/m2 x d. The results demonstrated that both anthracite and steel slag systems were highly effective in removing total P (CTP, 77.17 +/- 23.34% and 90.26 +/- 4.48%) and soluble reactive P (SRP, 92.14 +/- 12.56% and 96.20 +/- 2.58%). The system filled with anthracite, vermiculite and steel slag from the top down removed 82.45 +/- 9.52% and 87.83 +/- 8.58% of TP and SRP, respectively. However, other combined substrate systems showed comparative low and fluctuant P removal. The effluent pH was maintained at 7-9, which met environmental requirements of China. Therefore, anthracite provides a long-term high efficiency of P removal and may be a promising substrate from the standpoint of the effluent pH, and the arrangement of combined substrate has a prominent effect on P removal.  相似文献   

4.
The treatment performance of a maturation pond (MP), the typical final polishing stage of an Advanced Pond System (APS), is compared with that of a surface-flow constructed wetland (CW) over 19 months. Both received approximately 67 mm d-1 of wastewater after passage through upstream stages of the APS. The MP, with greater sunlight exposure, had higher algal biomass (and associated suspended solids) than the CW, showed higher dissolved oxygen (DO) concentrations and greater diurnal variation in DO and pH. Neither polishing stages reduced nutrients markedly, with the CW exporting slightly more NH(3)-N and DRP, and less NO(3)-N than the MP. Disinfection was more efficient in the MP (geometric mean 1 log load removal, 12 MPN (100ml)-1) compared to the CW (0.47 log load removal, 53 MPN (100ml)-1). Incorporation of a final rock filter (28% of area) reduced median solids levels to < 10 g m(-3) in both the MP and CW. A hybrid between MPs and CWs with alternating zones of open-water (for enhanced disinfection and zooplankton grazing of algal solids) and wetland vegetation (promoting sedimentation and denitrification, and providing refugia for zooplankton) may provide more consistent effluent quality that either stage alone.  相似文献   

5.
By using a two-stage constructed wetland (CW) system operated with an organic load of 40 gCOD.m(-2).d(-1) (2 m2 per person equivalent) average nitrogen removal efficiencies of about 50% and average nitrogen elimination rates of 980 g N.m(-2).yr(-1) could be achieved. Two vertical flow beds with intermittent loading have been operated in series. The first stage uses sand with a grain size of 2-3.2 mm for the main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a drainage layer with free drainage. The high nitrogen removal can be achieved without recirculation thus it is possible to operate the two-stage CW system without energy input. The paper shows performance data for the two-stage CW system regarding removal of organic matter and nitrogen for the two year operating period of the system. Additionally, its efficiency is compared with the efficiency of a single-stage vertical flow CW system designed and operated according to the Austrian design standards with 4 m2 per person equivalent. The comparison shows that a higher effluent quality could be reached with the two-stage system although the two-stage CW system is operated with the double organic load or half the specific surface area requirement, respectively. Another advantage is that the specific investment costs of the two-stage CW system amount to 1,200 EUR per person (without mechanical pre-treatment) and are only about 60% of the specific investment costs of the singe-stage CW system.  相似文献   

6.
One of the limits for the application of constructed wetlands (CWs) in mountain regions (such as the Alps) is associated with the considerable land area requirements. In some mountain areas, the treatment of domestic wastewater at popular tourist destinations is particularly difficult during the summer, when the presence of visitors increases hydraulic and organic loads. This paper aims to evaluate whether a hybrid CW plant designed on the basis of the resident population only, can treat also the additional load produced by the floating population during the tourist period (summer, when temperatures are favourable for biological treatment), without a drastic decrease of efficiency and without clogging problems. The research was carried out by considering two operational periods: the first one was based on literature indications (3.2 m(2)/PE in the VSSF unit) and the second one assumed higher hydraulic and organic loads (1.3 m(2)/PE in the VSSF unit). The removal efficiency in the hybrid CW system decreased slightly from 94 to 88% for COD removal and from 78 to 75% for total N removal, even after applying a double hydraulic (from 55 to 123 L m(-2) d(-1)) and organic load (from 37 to 87 g COD m(-2) d(-1) and from 4.4 to 10.3 g TKN m(-2) d(-1)). The results showed that in the summer period the application of high loads did not affect the efficiency of the hybrid CW plant significantly, suggesting that it is possible to refer the CW design to the resident population only, with subsequent considerable savings in superficial area.  相似文献   

7.
This research was conducted to investigate the phosphorus forms present in water, soil and sediment and to estimate the phosphorus mass balance in a surface flow constructed wetland (CW). Water quality and sediment samples were collected from each cell along the hydrologic path in the CW from October 2008 to December 2010. At the same time, three dominant plant species (e.g. common reed and cattails) were observed through the measurement of the weight, height and phosphorus content. Based on the results, the orthophosphate constituted 24-34% of total phosphorus in water for each cell. The overall average phosphorus removal efficiency of the CW was approximately 38%. The average inflow and outflow phosphorus loads during the monitoring period were 1,167 kg/yr and 408 kg/yr, respectively. The average phosphorus retention rate was 65%, was mainly contributed by the settling of TP into the bottom sediments (30%). The phosphorus uptake of plants was less than 1%. The estimated phosphorus mass balance was effective in predicting the phosphorus retention and release in the CW treating wastewater. Continuous monitoring is underway to support further assessment of the CW system and design.  相似文献   

8.
The phosphate removal abilities and crystallization performance of quartz sand, ceramsite, blast furnace slag and steel slag were investigated. The residual phosphate concentrations in the reaction solutions were not changed by addition of the ceramsite, quartz sand and blast furnace slag. The steel slag could provide alkalinity and Ca(2+) to the reaction solution due to its hydration activity, and performed a better phosphate removal performance than the other three. Under the conditions of Ca/P 2.0, pH 8.5 and 10 mg P/L, the phosphate crystallization occurred during 12 h. The quartz sand and ceramsite did not improve the phosphate crystallization, but steel slag was an effective seed crystal. The phosphate concentration decreased drastically after 12 h after addition of steel slag, and near complete removal was achieved after 48 h. The XRD analysis showed that the main crystallization products were hydroxyapatite (HAP) and the crystallinity increased with the reaction time. Phosphate was successfully recovered from low phosphate concentration wastewater using steel slag as seed material.  相似文献   

9.
A 2.0 L volume of EGSB reactor was operated at 20 degrees C for more than 500 days with 0.3-0.4 g COD/L of sucrose base wastewater to investigate the influence of effluent-recirculation on the process performance. At the start up period, the reactor was operated in EGSB mode with 5 m/h upflow velocity by continuous effluent recirculation. The COD loading was set to 7.2-9.6 kg COD/m(3) day with HRT of 1 hour. However, in this mode, EGSB reactor exhibited insufficient COD removal efficiency, i.e., 50-60%. Therefore, UASB mode (without recirculation, 0.7 m/h upflow velocity) was used for 30 minutes in every 40 minutes cycle to increase the COD concentration in the sludge bed. As a result, an excellent process performance was shown. The COD removal efficiency increased from 65% to 91% and the reactor could maintain a good physical property of retained sludge (sludge concentration: 33.4 g VSS/L and SVI: 25 mL/g VSS). Furthermore, retained sludge possessed sufficient level of methanogenic activity at 20 degrees C.  相似文献   

10.
In the first two years of operation a nitrogen removal efficiency of 53% and a high average elimination rate of 1,000 g N m(-2) yr(-1) could be observed for a two-stage vertical flow (VF) constructed wetland (CW) system. The two-stage system consists of two VF beds with intermittent loading operated in series, each stage having a surface area of 10 m2. The first stage uses sand with a grain size of 2-3.2 mm for the 50 cm main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a conventional drainage layer (with free drainage). The two-stage VF system was designed for and operated with an organic load of 40 g COD m(-2) d(-1) (i.e. 2 m2 per person equivalent). Data from the following years of operation showed that from the third year nitrogen elimination increased and stabilized. The median values of the nitrogen elimination rate in the first five years of operation have been 3.51, 2.76, 4.20, 3.84 and 4.07 g N m(-2) d(-1), the median value of the last three years being 3.8 g N m(-2) d(-1) and 1,380 g N m(-2) yr(-1), respectively, and the nitrogen removal > 60%. It can be assumed that the vegetation as well as the biofilm development in the two-stage VF CW system plays the major role for the enhancement of the nitrogen elimination rate.  相似文献   

11.
The removal of phosphate as magnesium ammonium phosphate (MAP, struvite) has gained a lot of attention. A novel approach using ureolytic MAP crystallization (pH increase by means of bacterial ureases) has been tested on the anaerobic effluent of a potato processing company in a pilot plant and compared with NuReSys(?) technology (pH increase by means of NaOH). The pilot plant showed a high phosphate removal efficiency of 83 ± 7%, resulting in a final effluent concentration of 13 ± 7 mg · L(-1) PO(4)-P. Calculating the evolution of the saturation index (SI) as a function of the remaining concentrations of Mg(2+), PO(4)-P and NH(4)(+) during precipitation in a batch reactor, resulted in a good estimation of the effluent PO(4)-P concentration of the pilot plant, operating under continuous mode. X-ray diffraction (XRD) analyses confirmed the presence of struvite in the small single crystals observed during experiments. The operational cost for the ureolytic MAP crystallization treating high phosphate concentrations (e.g. 100 mg · L(-1) PO(4)-P) was calculated as 3.9 € kg(-1) P(removed). This work shows that the ureolytic MAP crystallization, in combination with an autotrophic nitrogen removal process, is competitive with the NuReSys(?) technology in terms of operational cost and removal efficiency but further research is necessary to obtain larger crystals.  相似文献   

12.
Phosphorus (P) leaching from agricultural soils is a serious environmental concern. Application of aluminium water treatment residuals (Al-WTRs) at a rate of 20 Mg ha(-1) to clay soils from central Sweden significantly increased mean topsoil P sorption index (PSI) from 4.6 to 5.5 μmol kg(-1) soil. Mean degree of P saturation in ammonium lactate extract (DPS-AL) significantly decreased from 17 to 13%, as did plant-available P (P-AL). Concentrations of dissolved reactive P (DRP) decreased by 10-85% in leaching water with Al-WTR treatments after exposure of topsoil lysimeters to simulated rain. Soil aggregate stability (AgS) for 15 test soils rarely improved. Three soils (clay loam, silty loam and loam sand) were tested in greenhouse pot experiments. Aluminium-WTR application of 15 or 30 ton ha(-1) to loam sand and a clay loam with P-AL values of 80-100 mg kg(-1) soil significantly increased growth of Italian ryegrass when fertilised with P but did not significantly affect growth of spring barley on any soil. Al-WTR should only be applied to soils with high P fertility where improved crop production is not required.  相似文献   

13.
The efficacy of using constructed wetlands (CWs) to sequester organic carbon and nutrients from irrigation tailwaters was studied in the San Joaquin Valley, California. Two CWs were monitored during the 2004 irrigation season, a new CW (W-1) and 10-year-old CW (W-2). Input/output waters from CW were collected weekly and analyzed for a variety of water quality contaminants. Organic carbon, nutrient and sediment retention efficiencies were evaluated from input/output concentrations. Characteristics of sediment were examined spatially at W-2. Results indicate that W-2 was more efficient at contaminant removal. Average particulate organic carbon retention, was 70+/-13% (mean +/-standard deviation) in W-2 and 48+/-32% in W-1. Chlorophyll-a, a measure of algal biomass, was higher at W-1, especially in input waters. Initially, output concentration of chlorophyll-a increased 15-fold in W-2, however over time, as emergent vegetation established, chlorophyll-a decreased to 35% of input levels. Average total N removal efficiency was 45 +/-18% for W-2 compared to 22 +/-32% in W-1. Total P removal efficiency was 72+/-14% at W-2 compared to 18+/-26% at W-1. CWs were most effective at removing total suspended solids, 84 +/-15% and 97+/-2% for W-1 and W-2, respectively. Results demonstrate that CWs are effective at capturing POC, sediment and nutrients from irrigation tailwaters.  相似文献   

14.
针对我国目前大量钢渣未能有效利用的问题,考虑将其与粉煤灰混合作为路面基层材料。通过击实试验可以得到不同比例的钢渣粉煤灰的最大干密度与最佳含水率,最佳含水率最小为12.9%,最大干密度最大为2.04 g/cm3。钢渣粉煤灰配比为1:1、外加剂掺量为2.5%时抗压强度最大,达到了8.36 MPa,此配比的劈裂强度为0.82 MPa,其抗压强度与劈裂强度仅小于水泥稳定碎石。通过抗裂性能试验可以得到钢渣粉煤灰的平均干缩系数为25.91×10-6、平均温缩系数10.13×10-6,均小于水泥稳定碎石,因此钢渣粉煤灰是一种良好的路面基层材料。  相似文献   

15.
A comparative study to explore the characteristics of partially and fully packed biological aerated filters (BAFs) in the removal of carbon pollutant, reveals that the partial-bed reactor can perform comparably well with the full-bed reactor. The organic removal rate was 5.34 kg COD m(-3) d(-1) at Organic Loading Rates (OLR) 5.80+/-0.31 kg COD m(-3) d(-1) for the full-bed, and 5.22 kg COD m(-3) d(-1) at OLR 5.79+/-0.29 kg COD m(-3) d(-1) for the partial-bed. In the partial-bed system, where the masses of biomass were only 41-51% of those of the full-bed, the maximum carbon removal limit was still between 5 to 6 kg COD m(-3) d(-1). At organic loadings above 5.0 kg COD m(-3) d(-1), the carbon removal capacity in both systems was limited by the mass and activity of microorganisms. The SRT in the full and partial-bed reactors was primarily controlled by the biomass loss in the effluent and during backwash operation. The SRT was reduced from 20.08 days at OLR 4.18+/-0.20 kg COD m(-3) d(-1) to 7.62 days at OLR 5.80+/-0.31 kg COD m(-3) d(-1) in the full-bed, and from 7.17 days to 4.21 days in the partial-bed. After all, SRT values in the partial-bed were always lower than those in the full-bed.  相似文献   

16.
Constructed wetlands (CWs) are well recognized as having low construction and maintenance cost and low energy requirement. However, CW design has been mainly based on rule-of-thumb approaches. In this study, the efficiency of a modular horizontal subsurface flow (HSSF) CW using four different design schemes was investigated. Based on the results, the four systems have attained more than 90% removal of total suspended solids and more than 50% removal efficiency for total phosphorus, PO(4)-P and Zn. The planted system achieved higher pollutant removal rates than the unplanted system. In terms of media, bottom ash was more effective than woodchip in reducing the pollutants. Considering the flow length, optimum removal efficiency was achieved after passing the sedimentation tank and vertical media layer; with respect to depth, more pollutants were removed in the upper sand layer than in the lower gravel layer. This study recommended a surface area of 0.25 to 0.8% of catchment area for planted CW and 0.26 to 0.9% for unplanted CW using the 7.5 to 10 mm design rainfall.  相似文献   

17.
In France, gravel vertical flow constructed wetlands (gVFCWs) were adapted to treat raw wastewater, which led to important accumulations of matter in filters (organic and mineral). To prevent clogging, large gravel sizes were employed (O 2-6 mm). The aim of this paper was to present the influences of matter accumulation on the hydraulic and biological behaviour of the system. A one-year survey of accumulated matter content and potential respiration activities was completed in three gVFCWs (operating for 3, 4 and 8 years). Cores were sampled into filters. Results showed a vertical stratification of accumulated matter and respiration rates. Dry accumulated matter quantities ranged from 20 kg m(-2) (3 and 4 years operating) to 80 kg m(-2) in the oldest plant (8 years). Potential respiration was larger in the oldest plant (75g O2m(-2)h(-1)) than in the most recent one (15g O2m(-2)h(-1)). Accumulated matter seemed to play a role both on the water retention (enhancing initial percolation time by 5 times) and biological profile (enhancing microfauna's diversity). Contrary to what is generally proposed in the literature, accumulated matter in French gVFCWs seemed to provide better treatment efficiency without leading to surface clogging compared to systems using sand.  相似文献   

18.
Algal blooms in the Great Lakes are a concern due to excess nutrient loading from non-point sources; however, there is uncertainty over the relative contributions of various non-point sources under different types of land use in rural watersheds, particularly over annual time scales. Four nested subwatersheds in Southern Ontario, Canada (one natural woodlot, two agricultural and one mixed agricultural and urban) were monitored over one year to identify peak periods (‘hot moments’) and areas (‘hot spots’) of nutrient (dissolved reactive phosphorus, DRP; total phosphorus, TP; and nitrate, NO3) export and discharge. Annual nutrient export was small at the natural site (0.001 kg DRP ha−1; 0.004 kg TP ha−1; 0.04 kg NO3N ha−1) compared to the agricultural and mixed-use sites (0.10–0.15 kg DRP ha−1; 0.70–0.94 kg TP ha−1; 9.15–11.55 kg NO3N ha−1). Temporal patterns in P concentrations were similar throughout the sites, where spring was the dominant season for P export, irrespective of land use. Within the Hopewell Creek watershed, P and N hot spots existed that were consistently hot spots across all events with the location of these hot spots driven by local land use patterns, where there was elevated P export from a dairy-dominated sub-watershed and elevated N export from both of the two agricultural sub-watersheds. These estimates of seasonal- and event-based nutrient loads and discharge across nested sub-watersheds contribute to the growing body of evidence demonstrating the importance of identifying critical areas and periods in which to emphasize management efforts.  相似文献   

19.
Faecal sludge (FS) from the on-site sanitation systems is a nutrient-rich source but can contain high concentrations of toxic metals and chemicals and infectious micro-organisms. The study employed 3 vertical-flow CW units, each with a dimension of 5 x 5 x 0.65 m (width x length x media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/m(2).yr and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80-96%. A solid layer of about 80 cm was found accumulated on the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation sunflower plant (Helianthus annuus) plots, each with a dimension of 4.5 x 4.5 m (width x length). In the study, tap water was mixed with 20%, 80% and 100% of the CW percolate at the application rate of 7.5 mm/day. Based on a 1-year data in which 3 crops of plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increase in CW percolate ratios. In a plot with 100% of CW percolate irrigation, the maximum Zn, Mn and Cu concentrations of 5.0, 12.3 and 2.5 mg/kg, respectively, were detected in the percolate-fed soil, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower were detected. The highest plant biomass yield and oil content of 1000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate.  相似文献   

20.
In this study we investigated total and hexavalent chromium removal in an h-SSF constructed wetland (CW) planted with Phragmites australis and operating as post-treatment of effluent wastewater from an activated sludge plant serving the textile industrial district of Prato (Italy). Two measurement campaigns were carried out in 2006 and 2008-2010 in which more than 950 inlet and outlet samples were analyzed. When inlet and outlet concentrations were compared one to the other, the latter were found to be significantly lower than the former (p < 0.001); during the entire period of investigation, removal of hexavalent chromium equal to about 70% was achieved. Outlet concentrations ranged between values lower than the quantification limit (0.5 microg L(-1)) and 4.5 microg L(-1), and in all cases were therefore lower than the limit indicated for hexavalent chromium in the Italian regulation for water reuse (5 microg L(-1)). The comparison of the removal efficiencies achieved for hexavalent and trivalent chromium during the two campaigns suggested that the removal of the former can be sustained in the long term, while for the latter, the treatment efficiency is more sensitive to the age of the CW, being that it is it based on trivalent chromium retention in the reed bed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号