首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The consequences of hydrogen leaks and explosions are predicted for the sake of the safety in hydrogen refueling stations. In this paper, the effect of wind speed on hydrogen leak and diffusion is analyzed in different regions of a hydrogen refueling station, and the influence of delayed ignition time on hydrogen explosion after an accidental hydrogen leak is further studied by numerical simulation. Results show that the effect of wind speed on the probability of hydrogen fires is distinctive in different regions of hydrogen refueling station. The size of combustible clouds in the trailer front region and the outer region increases in the low wind speed case, and the front of combustible clouds is formed in a spherical shape in the outer region, which can greatly increase the probability of hydrogen explosion. However, the high wind speed may cause an increase of the risk of accidents in the near ground region. Moreover, a non-linear correlation is shown between the rate of combustible cloud dissipation and wind speed after the hydrogen stops leaking. In addition, it is found that an increase in delayed ignition time may lead to an increase in explosion intensity, which is related with the larger high temperature area and stronger explosion overpressure. Two flame fronts and the reverse propagation of the explosion overpressure can be observed, when the delayed ignition time is larger.  相似文献   

2.
A quantitative risk assessment of human life during the operation of a hydrogen refueling station (HRS) is conducted. We calculate the risks for three accident scenarios: a hydrogen leak from the external piping surrounding a dispenser, a hydrogen leak from an accumulator connection piping and a hydrogen leak from a compressor/connection piping in the HRS. We first calculate the probability of accident by multiplying the estimated leak frequency with the incident occurrence probability considering the ignition probability and failure probability of the safety barrier systems obtained through event tree analysis for each scenario. We next simulate the blast and flame effects of the ignition of concentration fields formed by hydrogen leakage. We then use existing probit functions to estimate the consequences of eardrum rupture, fatalities due to displacement by the blast wave, fatalities due to head injuries, first-degree burns, second-degree burns, and fatal burn injuries by accident scenario, leak size, and incident event, and we estimate the risk distribution in 1-m cells. We finally assess the risk reduction effects of barrier placement and the distance to the dispenser and quantify the risk level that HRSs can achieve under existing law. Quantitative risk assessment reveals that the risk for a leak near the dispenser is less than 10−6 per year outside a distance of 6 m to the dispenser. The risk for a leak near the accumulators and compressors exceeds 10−4 per year within a distance of 10 m from the ignition point. A separation of 6 m to the dispenser and a barrier height of 3 m keep the fatal risk from burns to the workers, consumers and residents and passersby below the acceptable level of risk. Our results therefore show that current laws sufficiently mitigate the risks posed by HRSs and open up the possibility for a regulatory review.  相似文献   

3.
Promoting fuel cells has been one of China's ambitious hydrogen policies in the past few years. Currently, several hydrogen fueling stations (HRSs) are under construction in China to fuel hydrogen-driven vehicles. In this regard, it is necessary to assess the risks of hydrogen leakage in HRSs. Aiming at conducting a comprehensive consequence assessment of liquid hydrogen (LH2) leakage on China's first liquid hydrogen refueling station (LHRS) in Pinghu, a pseudo-source model is established in the present study to simulate the LH2 leakage using a commercial CFD tool, FLACS. The effects of the layout of the LHRS, leakage parameters, and local meteorological conditions on the LH2 leakage consequence has been assessed from the perspectives of low-temperature hazards and explosion hazards. The obtained results reveal that considering the prevailing southeast wind in Pinghu city, the farthest low-temperature hazard distance and lower flammable limit (LFL) -distance occurs in the leakage scenario along the north direction. It is found that the trailer parking location in the current layout of the LHRS will worsen the explosion consequences of the LH2 leakage. Moreover, the explosion will completely destroy the control room and endanger people on the adjacent road when the leakage equivalent diameter is 25.4 mm. The performed analyses reveal that as the wind speed increases, the explosion hazard decreases.  相似文献   

4.
Hydrogen is one of important energy source in the next generation of renewable energy. It has powerful strength such as no emission from CO2 for fuel, Nevertheless, many countries have difficulties to expand hydrogen infra due to high risky from hydrogen. Especially, the hydrogen refueling station which is located in urban area has congested structure and high population around, it has higher risk than conventional refueling station. This paper presents a quantitative risk assessment (QRA) of a high pressure hydrogen refueling station in an urban area with a large population and high congestion between the instruments and equipment. The results show that leaks from the tube-trailer and dispenser as well as potential explosion of the tube-trailer are the main risks. For the safety of the station operator, customers and people surrounding the refueling station, additional mitigation plans such as adding additional safety barrier system have to be implemented on the compressor and dispenser in order to prevent continuous release of hydrogen from an accident.  相似文献   

5.
Ningbo's seaport hydrogen refueling station was used as the research object. The effects of different leakage angles, wind direction, roof shape, leakage hole diameters, temperature, and humidity on the diffusion of hydrogen leakage were studied by numerical simulation. The influence of leakage angle on hydrogen leakage is mainly reflected in the presence or absence of obstacles. The volume of the flammable hydrogen cloud was reduced by 31.16%, and the volume of the hazardous hydrogen cloud was reduced by 63.22% when there was no obstacle. The wind direction can significantly impact hydrogen leakage, with downwind and sidewind accelerating hydrogen discharge and reducing the risk. At the same time, headwind significantly increases the volume of the flammable hydrogen cloud. Compared with no wind, the volume of the flammable hydrogen cloud increased by 71.73% when headwind, but the volume of the hazardous hydrogen cloud decreased by 24.00%. If hydrogen shows signs of accumulation under the roof, the sloping roof can effectively reduce the hydrogen concentration under the roof and accelerate the hydrogen discharge. When the leakage angle θ = 90°, the sloping roof reduced the volume of the flammable hydrogen cloud by 11.74%. The leakage process was similar for different leak hole diameters in the no wind condition. The inverse of the molar fraction of hydrogen on the jet centerline was linearly related to the dimensionless axial distance of the jet in different cases. Using a least squares fit, the decay rate was obtained as 0.0039. In contrast, temperature and humidity have almost no effect on hydrogen diffusion. Hydrogen tends to accumulate on the lower surface of the roof, near the roof pillars and the hydrogen dispenser. In this paper, a set of hydrogen detector layout schemes was developed, and the alarm success rate was verified to be 83.33%.  相似文献   

6.
Although hydrogen refueling stations (HRSs) are becoming widespread across Japan and are essential for the operation of fuel cell vehicles, they present potential hazards. A large number of accidents such as explosions or fires have been reported, rendering it necessary to conduct a number of qualitative and quantitative risk assessments for HRSs. Current safety codes and technical standards related to Japanese HRSs have been established based on the results of a qualitative risk assessment and quantitative effectiveness validation of safety measures over ten years ago. In the last decade, there has been much development in the technologies of the components or facilities used in domestic HRSs and much operational experience as well as knowledge to use hydrogen in HRSs safely have been gained through years of commercial operation. The purpose of the present study is to conduct a quantitative risk assessment (QRA) of the latest HRS model representing Japanese HRSs with the most current information and to identify the most significant scenarios that pose the greatest risks to the physical surroundings in the HRS model. The results of the QRA show that the risk contours of 10?3 and 10?4 per year were confined within the HRS boundaries, whereas the risk contours of 10?5 and 10?6 per year are still present outside the HRS. Comparing the breakdown of the individual risks (IRs) at the risk ranking points, we conclude that the risk of jet fire demonstrates the highest contribution to the risks at all of the risk ranking points and outside the station. To reduce these risks and confine the risk contour of 10?6 per year within the HRS boundaries, it is necessary to consider risk mitigation measures for jet fires.  相似文献   

7.
Development of efficient hydrogen refueling station (HRS) is highly desirable to reduce the hydrogen cost and hence the life cycle expense of fuel cell vehicles (FCVs), which is hindering the large scale application of hydrogen mobility. In this work, we demonstrate the optimization of gaseous HRS process and control method to perform fast and efficient refueling, with reduced energy consumption and increased daily fueling capacity. The HRS was modeled with thermodynamics using a numerical integration method and the accuracy for hydrogen refueling simulation was confirmed by experimental data, showing only 2 °C of temperature rise deviation. The refueling protocols for heavy duty FCVs were first optimized, demonstrating an average fueling rate of 2 kg/min and pre-cooling demand of less than 7 kW for 35 MPa type III tanks. Fast refueling of type IV tanks results in more significant temperature rise, and the required pre-cooling temperature is lowered by 20 K to achieve comparable fueling rate. The station process was also optimized to improve the daily fueling capacity. It is revealed that the hydrogen storage amount is cost-effective to be 25–30% that of the nominal daily refueling capacity, to enhance the refueling performance at peak time and minimize the start and stop cycles of compressor. A novel control method for cascade replenishment was developed by switching among the three banks in the order of decreased pressure, and results show that the daily refueling capacity of HRS is increased by 5%. Therefore, the refueling and station process optimization is effective to promote the efficiency of gaseous HRS.  相似文献   

8.
In recent decades, the consequences of climate changes due to greenhouse gas (GHG) emissions have become ever more impactful, forcing international authorities to find green solutions for sustainable economic development. In this regard, one of the global targets is the reduction of fossil fuels utilization in the transport sector to encourage the diffusion of more environmentally friendly alternatives. Among them, hydrogen is emerging as a viable candidate since it is a potentially emission-free fuel when produced by exploiting renewable energy sources (RES). Nevertheless, to allow widespread use of this gas in the transport sector, several technoeconomic barriers, including production cost, and lack of distribution and storage infrastructure, have to be overcome. Distributed hydrogen production via renewable energy-powered electrolysis could be an effective solution to reduce cost and lead to economies of scale. In this study a multi-hub configuration with on-site production from PV-powered electrolysis and centralized production from steam methane reforming (SMR) is proposed. In particular, an infrastructure network for a bus refueling station located in Lazio is considered as a case study. First, each hub, composed of PV panels, an electrolyzer, a compression system, high-pressure and low-pressure storages, and hydrogen dispensers with chiller, is modeled in a Matlab/Simulink environment. Then, a design perturbation analysis is carried out to determine the impact of the configuration on the refueling station performance in terms of carbon emissions levels and the Levelized Cost of hydrogen (LCOH). The results show a significant influence of the station size on the economic performance highlighting significant benefits (reduction up to 40% in the LCOH) for a 80 bus HUB with a saturating trend towards larger sizes. CO2 emissions per unit mass of hydrogen are kept limited for all the stations thanks to the synergistic effects of SMR and Electrolyzer. Interconnecting more than one station each other further benefits can be achieved from the environmental perspective (savings up to 5 tons of CO2 are demonstrated for a typical summer case study).  相似文献   

9.
Numerous accidents in HRSs have been reported worldwide in accident databases; therefore, many researchers have performed quantitative risk assessments (QRAs) of HRSs to enable risk-informed decision making in determining the safety distances or risk mitigation measures. The HRSs, located in urban areas such as Tokyo in Japan, are situated in congested areas with tall buildings and high population density; thus, they have relatively narrow station areas. However, the QRAs are generally suitable for large plants such as nuclear power plants or chemical plants; therefore, relatively small plants or installations, such as HRSs, have not yet been considered as QRA objects. Hence, it is necessary to conduct detailed QRAs with risk analyses and reduce the applied uncertainties for relatively small plants or installations. We applied a model-based approach of risk assessment to model the HRS process using multi-physics system-level modeling and simulated a target system using Modelica—an equation-based, object-oriented modeling language that allows acausal modeling of complex cyber-physical systems The primary aim of this study was to conduct a QRA of an HRS based on multi-physics system-level modeling. First, we modeled the HRS components and physical relationships between the components using basic physical equations. Then, we elucidate a QRA based on the constructed model. The difference in the leakage rates due to the leak positions and dynamic behavior of the model parameters were calculated using the constructed model. Finally, we estimated the individual risks of all the scenarios and compared the resulting risk contours based on the constructed model that includes the hydrogen-fuel dynamic behavior with those based on the traditional model. These results indicate that it is possible to assess whether the risks around the station boundary are acceptable based on the scenario information obtained by evaluating the risks near the station.  相似文献   

10.
Creating a distribution network and establishing refueling stations arises as an important problem in order to meet the refueling needs of hydrogen fuel cell vehicles. In this study, a multi-objective and multi-period hydrogen refueling station location problem that can take into account long-term planning decisions is proposed. Firstly, single objective mathematical models are proposed for the problem by addressing the cost, risk and population convergence objectives. Afterwards, a goal programming model is proposed and the results that will arise when three objectives are taken into consideration at the same time are examined. A risk analysis approach applied for each location alternative is considered in order to handle risk concerns about the hydrogen refueling station settlement. A case study is conducted in Adana, one of the crowded cities in Turkey, to determine the long-term location network plan. Covered population, operational risk and earthquake risks are used as input of the risk analysis method. The case study results show that the goal programming model covers the area with 77 hydrogen refueling stations by different types and capacities during the years from 2020 to 2030. In addition, a computational study is carried out with different alternative scenarios (different number of consumption nodes and all parameters in the model). The computational study results show that the highest deviations from the optimal solution on the model are observed in the distances between consumption nodes and targeted service area parameters which affect about 50% of absolute deviations on average. According to results, the proposed approach selects the station location suitable for the expected changes over the years.  相似文献   

11.
The construction of hydrogenation infrastructure is important to promote the large-scale development of hydrogen energy industry. The technical performance of hydrogen refueling station (HRS) largely determines the refueling efficiency and cost of hydrogen fuel cell vehicles. This paper systematically lists the hydrogen refueling process and the key equipment applicable in the HRS. It comprehensively reviews the key equipment configuration from the hydrogen supply, compression, storage and refueling of the HRS. On the basis of the parameter selection and quantity configuration method, the process optimization technology related to the equipment utilization efficiency and construction cost was quantitatively evaluated. Besides, the existing problems and prospects are put forward, which lays the foundation for further research on the technical economy of HRSs.  相似文献   

12.
Studies focused on the behavior of the hydrogen leakage and diffusion are of great importance for facilitating the large scale application of the hydrogen energy. In this paper, the hydrogen leakage and diffusion in six scenarios which including comparison of different leakage position and different wind effect are analyzed numerically. The studied geometry is derived from the hydrogen refueling station in China. Due to the high pressure in hydrogen storage take, the hydrogen leakage is momentum dominated. The hydrogen volume concentration with the variation of the leakage time in different scenarios is plotted. More importantly, profiles of the flammable gas cloud at the end of the leakage are quantitatively studied. Results indicate that a more narrow space between the leakage hole and the obstacle and a smaller contact area with the obstacle make the profile of the flammable gas cloud more irregular and unpredictable. In addition, results highlight the wind effect on the hydrogen leakage and diffusion. Comparing with scenario which the wind direction consistent with the leakage direction, the opposite wind direction may result in a larger profile of the flammable gas cloud. With wind velocity increasing, the profile of the flammable gas cloud is confined in a smaller range. However, the presence of the wind facilitates the form of the recirculation zone near the obstacle. With an increase of the wind velocity, the recirculation zone moves downward along the obstacle. Thus, the hydrogen accumulation is more prominent near the obstacle.  相似文献   

13.
Air driven gas boosters are often deployed in small scale compression systems. Manufacturers specifications, reporting outlet flow for a fixed inlet pressure, do not reflect the batch operation from a limited source storage. Thus, the dynamic variation of critical process parameters such as efficiency, temperature and flow are not documented.Using a hydrogen refueling station demonstrator, the data from more than 20′000 compression cycles is compiled and analyzed. Experimentally derived correlations are determined for an air driven gas booster feeding a cascade storage. A specific analysis of the clearance volume and the working air pressure is introduced.An engineering tool was developed in MATLAB for performance forecasting. It allows the user to simulate the process trends with an accuracy of ±5%. In the context of a hydrogen refueling station, duration, temperature, compression cycles and air consumption data can be used for process management and maintenance planning.  相似文献   

14.
Several countries are incentivizing the use of hydrogen (H2) fuel cell vehicles, thereby increasing the number of H2 refueling stations (HRSs), particularly in urban areas with high population density and heavy traffic. Therefore, it is necessary to assess the risks of gaseous H2 refueling stations (GHRSs) and liquefied H2 refueling stations (LHRSs). This study aimed to perform a quantitative risk assessment (QRA) of GHRSs and LHRSs. A comparative study is performed to enhance the decision-making of engineers in setting safety goals and defining design options. A systematic QRA approach is proposed to estimate the likelihood and consequences of hazardous events occurring at HRSs. Consequence analysis results indicate that catastrophic ruptures of tube trailer and liquid hydrogen storage tanks are the worst accidents, as they cause fires and explosions. An assessment of individual and societal risks indicates that LHRSs present a lower hazard risk than GHRSs. However, both station types require additional safety barrier devices for risk reduction, such as detachable couplings, hydrogen detection sensors, and automatic and manual emergency shutdown systems, which are required for risk acceptance.  相似文献   

15.
A low flow rate and short diaphragm life are the two disadvantages of diaphragm compressors when applied in hydrogen refueling stations. A new generatrix of the cavity profile of a diaphragm compressor was developed in this study to increase the cavity volume and decrease the diaphragm radial stress. A reduction in the diaphragm radial stress that resulted from the new design was validated by experiment and numerical simulation. The volumes of the cavities with different generatrices and the radial stress distribution of the diaphragm were investigated under various design conditions. The results indicated that the volume of the cavity with the new generatrix was approximately 10% larger than that with a traditional generatrix at the same allowable stress and cavity radius. At a similar cavity volume and radius, the radial stress values of the diaphragm in the cavity with the new generatrix were low. The decrease rate of the maximal radial stress of the diaphragm in the cavity with the new generatrix reached 13.8%. In the diaphragm centric region, where additional stress was induced by discharge holes, the maximal radial stress decrease rate reached 19.6%.  相似文献   

16.
This paper presents a QRA study on a gaseous hydrogen refueling station of 2010 World Expo. Risks to station personnel, to refueling customers and to third parties are evaluated respectively. Uncertainties that intervene in the risk analysis are also discussed. The results show that the leaks from compressors and dispensers are the main risk contributors to first party and second party risks of the Expo station, indicating that risk mitigation measures should in the first place be implemented on compressors and dispensers. For the sake of the safety of station personnel, customers, and people outside the Expo station, additional safety barrier systems must be implemented on compressors and dispensers to prevent continuous release of hydrogen from happening. With appropriate mitigation measures on compressors and dispensers, risks to all three parties of the Expo station can be reduced to the value lower than the risk acceptance criteria.  相似文献   

17.
Ambient condition, especially the wind condition, is an important factor to determine the behavior of hydrogen diffusion during hydrogen release. However, only few studies aim at the quantitative study of the hydrogen diffusion in a wind-exist condition. And very little researches aiming at the variable wind condition have been done. In this paper, the hydrogen diffusion in different wind condition which including the constant wind velocity and the variable wind velocity is investigated numerically. When considering the variable wind velocity, the UDF (user defined function) is compiled. Characteristics of the FGC (flammable gas cloud) and the HMF (hydrogen mass fraction) are analyzed in different wind condition and comparisons are made with the no-wind condition. Results indicate that the constant wind velocity and the variable wind velocity have totally different effect for the determination of hydrogen diffusion. Comparisons between the constant wind velocity and the variable wind velocity indicate that the variable wind velocity may cause a more dangerous situation since there has a larger FGC volume. More importantly, the wind condition has a non-negligible effect when considering the HMF along the radial direction. As the wind velocity increases, the distribution of the HMF along the radial direction is not Gaussian anymore when the distance between the release hole and the observation line exceeds to a critical value. This work can be a supplement of the research on the hydrogen release and diffusion and a valuable reference for the researchers.  相似文献   

18.
Hydrogen precooling is an effective method to realize safe, adequate, and fast filling for fuel cell vehicles. Estimating cooling demand is essential for the precooling unit configuration and energy analysis. Complex pipelines exist between the station's storage tanks and the vehicle cylinder. However, their impact on the cooling demand is often underestimated. In this paper, a thermodynamic model of the whole hydrogen refueling process was established to investigate the impact of pipelines in different positions. Accordingly, the influence of pipelines on the thermodynamic parameters was analyzed. Then the effects on the precooling performance were concluded. The results show that flow resistance before the breakaway increases total cooling demand by 9.9%. Meanwhile, heat dissipation through the pipe, located between the control valve and the heat exchanger, smoothens the cooling demand curve and reduces the total cooling demand by 5.7%. After the break-away, the flow resistance of pipelines significantly changes the mass flow rate curve and cooling demand. Heat absorption from the pipe wall slightly influences the cooling demand but jeopardizes refueling safety.  相似文献   

19.
The Republic of Korea government has set yearly targets of hydrogen cars and buses and plans to install hydrogen refueling stations nationwide. This paper proposes a methodology for developing a strategic deployment plan with three mathematical models. For a given target, future refueling demand locations and amount from general road and expressway are systematically estimated. First, the required number of refueling stations to satisfy the target covering ratio of the total demand set by the government is determined by the Station number determination model. Next, the locations of the capacitated stations and the allocation of demand to the stations are determined by the second Max cover and the third p-median models. Since the max covering is more important than minimizing the travel time, the two models are used sequentially. The nationwide hydrogen station deployment plan for the years 2022–2040 obtained by the proposed methodology is reported.  相似文献   

20.
The literature lacks a systematic analysis of HRS equipment and operating standards. Researchers, policymakers, and HRS operators could find this information relevant for planning the network's future expansion. This study is intended to address this information need by providing a comprehensive strategic overview of the regulations currently in place for the construction and maintenance of hydrogen fueling stations.A quick introduction to fundamental hydrogen precautions and hydrogen design is offered. The paper, therefore, provides a quick overview of hydrogen's safety to emphasize HRS standards, rules, and regulations. Both gaseous and liquid safety issues are detailed, including possible threats and installation and operating expertise.After the safety evaluation, layouts, equipment, and operating strategies for HRSs are presented, followed by a review of in-force regulations: internationally, by presenting ISO, IEC, and SAE standards, and Europeanly, by reviewing the CEN/CENELEC standards. A brief and concise analysis of Italy's HRS regulations is conducted, with the goal of identifying potential insights for strategic development and more convenient technology deployment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏