首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Outdoor particles can penetrate through wall assemblies and influence the indoor air quality (IAQ). In this study, a computational fluid dynamics (CFD) model was developed for predicting the particle penetration through wood-framed residential wall assemblies. The model included a simplified approach to account for the particle loss due to the fiberglass insulation material layer in the wall assemblies. Particles ranging from 0.001 to 10 μm in diameter were studied. Particle movement was modeled following an Eulerian approach, while particle deposition in the fiberglass insulation was accounted for by an additional sink term in the governing equation, derived from the classical filtration theory. The model was applied to a typical residential wall assembly, assuming crack heights of 1 mm in the vertical direction and 3 mm in the horizontal direction and a fiberglass insulation width of 0.14 m. The results showed that 0.05–1 μm particles were the most penetrable particles. The fiberglass insulation media reduced the particle penetration by more than 85% when the air permeability of the fiberglass insulation was larger than 0.001 s.

Copyright 2015 American Association for Aerosol Research  相似文献   

2.
Isokinetic sampling is required when evaluating the aerodynamic sizes of particles released from dry powder inhalers (DPI) under simulated breathing condition since anisokinetic sampling may lead to significant sampling error for coarse particles. We propose an isokinetic measuring system for aerosol particles from a stream in a narrow conduit of variable flow rates (variable flow rate aerosol sampler, VFAS) combined with Aerodynamic Particle sizer® APSTM spectrometer (model 3321, TSI Inc.). The VFAS was capable of generating variable sampling flow rates by adjusting the flow resistance of makeup air to produce constant flow rate of aerosol to the APS. The penetrations through the VFAS-APS system were measured using monodisperse particles with a size range of 0.7–15 μm by applying a rectangular flow rate–time pattern of sampling air, and we found that the VFAS-APS system can measure the number concentration of particles with the particle detection efficiency (particle penetration through the system) of almost unity. The VFAS-APS system may be a powerful tool to measure the size and concentration of powder released by the DPI in the size range of 0.5–15 μm.

Copyright 2012 American Association for Aerosol Research  相似文献   

3.
《分离科学与技术》2012,47(7):1583-1594
Abstract

To investigate the dependence of filter ripening on particle size and surface charge, multiple experiments were conducted under different particle destabilization conditions including pH control, alum, and polymer destabilization. Laboratory‐scale filtration experiments were performed at a filtration velocity of 5 m/h using spherical glass beads with mean diameter of 0.55 mm as collectors. Particle suspensions with a broad size distribution and a 1.7 µm mean particle size were filtered through a 10 cm depth filter column. Better initial solids removal was confirmed under favorable particle and collector conditions (i.e., under smaller surface charge), but better initial particle removal does not necessarily mean better overall particle removal efficiency. It was shown that changes of the particle size distribution (PSD) in the effluent can significantly influence overall particle removal efficiency. Chemical parameters such as zeta potential can be important during the initial stage of filtration, but their importance can decrease over time depending on the specific chemical conditions. The influent PSD and the removal of certain size particles during the initial stage of filtration can significantly influence ripening, which in turn, can influence the overall particle removal efficiency.  相似文献   

4.
This paper explores numerical and experimental studies on the performance of a pneumatic conveying dryer. The four-way coupling Eulerian–Lagrangian approach is utilized in the numerical study and the experimental study is carried out in a pilot-scale vertical pneumatic conveying dryer of diameter 8.1 cm and 4.5 m length. The effects of Reynolds number, particle size, solid mass flow rate, and inlet gas temperature on the dryer performance are investigated. It is found that the present model predictions agree well with the experimental data. Generally, it is concluded that the drying rate increases as the Reynolds number increases, while increasing the particle size or the solid mass flow rate decreases the drying rate.  相似文献   

5.
Several low-volume inlets (flow rates ≤ 16.7 liters per minute (Lpm)) are commercially available as components of low-cost, portable ambient particulate matter samplers. Because the inlets themselves do not contain internal fractionators, they are often assumed to representatively sample “total” mass concentrations from the ambient air, independent of aerodynamic particle size and wind speed. To date, none of these so-called “TSP” inlets have been rigorously tested under controlled conditions. To determine their actual size-selective performance under conditions of expected use, wind tunnel tests of six commonly used omnidirectional, low-volume inlets were conducted using solid, polydisperse aerosols at wind speeds of 2, 8, and 24 km/h. With the exception of axially-oriented, isokinetic sharp-edge nozzles operating at 5 and 10 Lpm, all low-volume inlets showed some degree of nonideal sampling performance as a function of aerodynamic particle size and wind speed. Depending upon wind speed and assumed ambient particle size distribution, total mass concentration measurements were estimated to be negatively biased by as much as 66%. As expected from particle inertial considerations, inlet efficiency tended to degrade with increasing wind speed and particle size, although some exceptions were noted. The implications of each inlet's non-ideal behavior are discussed with regards to expected total mass concentration measurement during ambient sampling and the ability to obtain representative sampling for size ranges of interest, such as PM2.5 and PM10. Overall test results will aid in low-volume inlet selection and with proper interpretation of results obtained with their ambient field use.

Copyright © 2018 American Association for Aerosol Research  相似文献   


6.
We designed a thermal precipitator in a cylindrical configuration with a size-selective inlet, and investigated its performance in experiments using differential mobility analyzer (DMA)-classified particles of sodium chloride (NaCl) and polystyrene latex (PSL). Our investigation was performed in two parts: (1) using the size-selective inlet to determine the best inlet-to-wall distance for optimal impaction of 1 μm particles; (2) using a simple inlet tube to measure particle collection via thermophoresis over a size range from 40 nm to 1000 nm. The results showed that the inlet had a particle cut-off curve, with a 50% particle cut-off Stokes number of 0.238, resulting in removing particles with sizes larger than 1 μm at an aerosol flow rate of 1.5 lpm. The thermophoretic particle collection efficiency in the prototype was measured without the size-selective inlet installed. The size dependence of the collection efficiency was negligible for particles with diameters ≤300 nm and became noticeable for those with diameters >300 nm. An analytical model was further developed to estimate the particle collection efficiency due to thermophoresis of the prototype under various aerosol flow rates and temperature gradients. For particles with diameters less than 400 nm, reasonable agreement was obtained between the measured data and the collection efficiency calculated from the developed analytical model. It was further concluded that the derived formula for the calculation of thermophoretic particle collection efficiency could serve as the backbone for future design of thermal precipitators in any configuration, when combined with the proper formula for the dimensionless thermophoretic particle velocity.

Copyright 2012 American Association for Aerosol Research  相似文献   

7.
Understanding the filtration characteristics of fibrous particles is important since those particles have caused health and environmental concerns. Due to the straight morphology of metal nanowires, unlike carbon nanotube (CNT) particles nanowires can be considered as appropriate test material to evaluate existing filtration theory for cylindrical particles. We measured the penetration of silver nanowires in the size range of dm = 200 to 400 nm through screen mesh filter. By using Li et al. (2012)'s theory, we determined the orientation status of silver nanowires inside differential mobility analyzer (DMA) and calculated the dynamic shape factor of nanowires. Theoretical penetration was obtained by using single fiber theory with modified interception parameter including orientation angle between a filter wire and a particle. The orientation angle obtained by fitting experimental data into single fiber theory for the 1 layer of screen mesh filter is found to be close to 40° indicating random orientation of nanowires near filter. However, in the experiments with multi-layers of screen mesh, any tendency related to the orientation angle was not found. We performed numerical simulations for the filtration processes such as impaction, diffusion, interception, and interception of diffusing particles by introducing modified slip correction factor. Overall, when interception of diffusing particles is considered in addition to diffusion and interception, numerically simulation results and theoretical prediction agree better with experimental data regarding the penetration of silver nanowires through the 1 layer of screen mesh filter.

Copyright 2014 American Association for Aerosol Research  相似文献   


8.
This article presents a cylindrical counter-current flow diffusion denuder with high efficiency penetration of nanoparticles, for non-specific removal of trace gases from an air flow. The denuder was designed to exchange gases in the sample flow by diffusion to the purge flow across a cylindrical microporous glass tube. Laboratory test results indicated that removal efficiencies of gases increased with a lower sample flow rate and a higher sample to purge flow rate ratio. Additionally, the pore size of the microporous glass did not affect gas removal efficiency and particle penetration following optimization of sample and purge flow rate conditions. Significantly high particle penetration was obtained for the counter flow denuder technique (94% penetration for 20 nm of polystyrene latex particle [PSL]) that agreed with theoretical estimation attributed to diffusion loss.

Copyright © 2017 American Association for Aerosol Research  相似文献   


9.
Particulate gas filters are a critical element in the purification systems used to ensure defect-free manufacturing in semiconductor industry. In atomic layer deposition (ALD) processes, these filters are typically operated under sub-atmospheric pressure conditions, but their filtration characteristics are, often, only known at atmospheric pressure. In this study, performance of a metal filter that is typically used in low-pressure ALD precursor delivery systems is studied experimentally and theoretically down to 4.5 kPa. The experimental procedure was designed to minimize the presence of multiply charged particles in the test aerosol for different operating pressures and flowrates. The experimental results suggest that most penetrating particle size only slightly varies with pressure, but the shape of the penetration curve and the maximum value of the penetration changes significantly with pressure. The experimental data are used to test predictions of filter performance at low pressures made using classical theory. The comparison results suggest that the combination of classical theory and manufacturer-specified parameters results in large errors in calculated penetration values at low pressures. Accurate predictions are seen to be possible for particle Stokes numbers less than 0.1, when an inhomogenous filtration model is used in combination with effective filter parameters that are obtained from experimental measurements of filter efficiency and pressure drop at atmospheric pressures.

Copyright © 2016 American Association for Aerosol Research  相似文献   


10.
《Drying Technology》2013,31(6):1049-1064
Abstract

The main objective of this work is to study the rice whiteness and paddy qualities of rice in terms of hardness, stickiness, cohesiveness, and germination of rice. The prediction results of moisture content and whiteness are compared with the experimental results using a near-equilibrium drying model, which is modified by including whiteness kinetics of rice kernel. The long grain rice (Suphanburi 1 high amylose indica variety), which consists of 27% amylose was used for all experiments. The experiments were carried out at the average ambient temperature range of 28.6–30.8°C, average relative humidity of 65.2–80.6% with a fixed bed depth of 1.0 m. Specific air flow rates of 0.65 and 0.93 m3/min-m3 of paddy were forced continuously through the paddy bulk at initial moisture contents of 18.5% and 20.1% wet basis, respectively. The desired final moisture content of paddy is about 13.3 ± 0.6% wet basis. The results show that drying rate and the whiteness predictions are in good agreement with those from the experiments. The in-store drying using ambient air condition did not produce notable effect on the rice whiteness, head rice yield, and the percentage of paddy germination. However, the hardness, stickiness, and cohesiveness of rice were changed.  相似文献   

11.
The collection efficiencies of commonly used membrane air sampling filters in the ultrafine particle size range were investigated. Mixed cellulose ester (MCE; 0.45, 0.8, 1.2, and 5 μm pore sizes), polycarbonate (0.4, 0.8, 2, and 5 μm pore sizes), polytetrafluoroethylene (PTFE; 0.45, 1, 2, and 5 μm pore sizes), polyvinyl chloride (PVC; 0.8 and 5 μm pore sizes), and silver membrane (0.45, 0.8, 1.2, and 5 μm pore sizes) filters were exposed to polydisperse sodium chloride (NaCl) particles in the size range of 10–400 nm. Test aerosols were nebulized and introduced into a calm air chamber through a diffusion dryer and aerosol neutralizer. The testing filters (37 mm diameter) were mounted in a conductive polypropylene filter-holder (cassette) within a metal testing tube. The experiments were conducted at flow rates between 1.7 and 11.2 l min?1. The particle size distributions of NaCl challenge aerosol were measured upstream and downstream of the test filters by a scanning mobility particle sizer (SMPS). Three different filters of each type with at least three repetitions for each pore size were tested. In general, the collection efficiency varied with airflow, pore size, and sampling duration. In addition, both collection efficiency and pressure drop increased with decreased pore size and increased sampling flow rate, but they differed among filter types and manufacturer. The present study confirmed that the MCE, PTFE, and PVC filters have a relatively high collection efficiency for challenge particles much smaller than their nominal pore size and are considerably more efficient than polycarbonate and silver membrane filters, especially at larger nominal pore sizes.  相似文献   

12.

This study investigates the filtration characteristics of a miniature dual saw-like electrodes electrostatic precipitator (ESP). Parameters such as particle size, rate of airflow through the ESP, voltage of charge electrode, and discharge polarity were considered to study their influence on aerosol penetration through the ESP. Polydisperse and monodisperse particles with sizes ranging from 30 nm to 10 w m were used as the challenge aerosols. Experimental results indicated that the aerosol penetration through the ESP decreased (from 96% to 15% for 0.3 w m) as the voltage of the discharge electrode increased (from + 4 kV to +8 kV) at a flow rate of 30 L/min. At a fixed electrode voltage (+8 kV), aerosol penetration increased from 15% to 69% for 0.3 w m particles as the flow rate increased from 30 to 120 L/min. The most penetrating particle size was in the range of 0.25 w m to 0.5 w m depending on the discharge voltage and the flow rate. In general, the most penetrating particle size of the ESP decreased with decreasing discharge voltage or with increasing flow rate. At the same voltage level but opposite polarity, the aerosol penetration through the ESP with negative corona was lower than that with positive corona. The difference in aerosol penetration was a factor of about 2 between the negative and positive coronas for 0.3 w m particles, and this difference was found to be independent of discharge voltage. Regarding energy conservation, use of a negative-polarity ESP was more economical if the same efficiency was required. However, the ozone generated by the ESP with negative polarity was about five times greater than that generated with positive polarity. Therefore when using an ESP as an indoor air cleaner, the search for an optimum balance between ozone production and aerosol collection efficiency should be considered.  相似文献   

13.
14.
15.
This paper presents a novel approach for simulation of filtration process when velocity gradient within pore space cannot be neglected. The new model is useful for accurate prediction of the filtration performance and particle retention efficiency. Artificial porous media such as filters, by design, have a large surface-to-volume ratio because of an inherent homogeneity present within their structure; the homogenous structure is realized due to organized packing of grains as building blocks, which leads to a significant velocity gradient inner pore space. In this work, the inner-pore flow characteristics of two different homogeneous packing patterns (cubic and oblique hexagonal packing) were examined. The multiple constricted tubes analogy was adopted to model porous media to simplify the inner-pore geometrical structure. A new integrated simulation approach was utilized through implementing the particle trajectory model to every unit bed element of the simulation domain. The accuracy of the numerical simulations used in this study was verified by comparing the particle distribution pattern and penetration depth obtained from simulations to those monitored via a visual experiment. A sensitivity analysis was carried out to study parameters that may affect the particle distribution and penetration length, such as grain-to-particle size ratio, flow rate, and fluid viscosity. The simulation method utilized in this paper provides an in-depth understanding of the fine particle migration during filtration process through artificial porous media, and, thus, provide useful insights for improved filtration design.  相似文献   

16.
Computational fluid dynamics (CFD) was used to study aerosol penetration through the entrance section of a bell-shaped omni-directional ambient aerosol sampling inlet. The entrance section did not include either an insect screen or a large-particle pre-separator. Simulations of the flow field were carried out for wind speeds of 2, 8, and 24 km/h and a fixed exhaust flow rate of 100 L/min; and, particle tracking was performed for 2 to 20 μ m aerodynamic diameter particles. Penetration calculated from CFD simulations was in excellent agreement with experimental results from previous studies with the root mean square relative error between simulation and experimental data being 3.8%. CFD results showed that the most significant regional particle deposition occurred on the upwind side of a curved flow passage between two concentric axisymmetric shells of the inlet housing and that deposition at the leading edges of the shells and within the exhaust tube was far less significant. At a wind speed of 2 km/h, penetration was affected by gravitational settling, e.g., penetration of 20 μ m particles was 71.9% when gravity was included and 80.4% without gravity. At higher wind speeds gravity had little effect. An empirical equation was developed to relate aerosol penetration to a Stokes number, a gravitational settling parameter, and a velocity ratio. Good fits of the correlation curves to experimental data and numerical results were obtained.  相似文献   

17.
The effect of image force on the penetration of nanometer particles through metal grids remains a controversial issue. Experimental evidence of the existence and of the absence of such effect have both been reported in the past. A careful experimental work to measure penetration of particles in the mobility equivalent diameter range between 3.4 and 10 nm has been carried out. The possible particle size change between the aerosol generator and the filter has been considered, as well as the possible effect of particle number concentration on the filtration efficiency. The geometric dimensions of the filter allowed attainment of the fully developed parabolic flow velocity profile upstream the grid. Measurements were done at two values of the fiber Reynolds number, 0.09 and 0.12, much smaller than 1, as demanded by the currently accepted filtration theory. Penetration of charged particles, measured in three alternative ways, has been compared with penetration of uncharged and neutral particles (the latter consisting of a mixture of positive, negative, and uncharged particles). Two main conclusions have been reached: (1) the charging state of the particles does not affect their penetration through the metal grid and (2) the experimentally measured penetrations are fairly well predicted by the fan filter model of Cheng and Yeh.

Copyright © 2018 American Association for Aerosol Research  相似文献   


18.
Aerosol collection efficiency was studied for electrostatically charged fibrous filters (3M Filtrete?, BMF-20F). In this study, collection efficiencies at moderate filter face velocities (0.5–2.5 m/s) representative of some high volume sampling applications was characterized. Experimental data and analytical theories of filter performance are less common in this flow regime since the viscous flow field assumption may not be representative of actual flow through the filter mat. Additionally, electrostatic fiber charge density is difficult to quantify, and measurements of aerosol collection efficiency are often used to calculate this fundamental parameter. The purpose of this study was to assess the relative influence of diffusion, inertial impaction, interception, and electrostatic filtration on overall filter performance. The effects of fiber charge density were quantified by comparing efficiency data for charged and uncharged filter media, where an isopropanol bath was used to eliminate electrostatic charge. The effects of particle charge were also quantified by test aerosols brought into the equilibrium Boltzmann charge distribution, and then using an electrostatic precipitator to separate out only those test particles with a charge of zero. Electrostatically charged filter media had collection efficiencies as high as 70–85% at 30 nm. Filter performance was reduced significantly (40–50% collection efficiency) when the electrostatic filtration component was eliminated. Experiments performed with zero charged NaCl particles showed that a significant increase in filter performance is attributable to an induction effect, where electrostatic fiber charge polarizes aerosol particles without charge. As filter face velocity increased the electrostatic filtration efficiency decreased since aerosol particles had less time to drift toward electrostatically charged fibers. Finally, experimental data at 0.5 m/s were compared to theoretical predictions and good agreement was found for both electrostatic and nonelectrostatic effects.

© 2013 American Association for Aerosol Research  相似文献   

19.
《分离科学与技术》2012,47(15):3777-3797
Abstract

Effects of geometric structure parameters of 10 mm-diameter hydrocyclones on the particle separation efficiency are studied using computational fluid dynamics (CFD). The fluid velocity profiles and particle trajectories are simulated using RFLOW software with a standard isotropic k-ε turbulent model. The JIS standard CaCO3-17 particles are adopted as a particulate sample in simulations and experiments. Comparing the simulated results with experimental data, a maximum deviation about 20% in partition curves occurs for 5–10 µm particles. However, fairly good agreements for the cut-size predictions and the fish-hook phenomenon are obtained. The simulated cut-size d 50 is only 2 µm larger than that measured in experiments, while the value of d 100 can be accurately predicted. An increase in overflow diameter or a decrease in underflow diameter leads to a lower separation efficiency but a clearer separation sharpness due to lower fluid underflow rate. A short-and-wide rectangular inlet is more efficient for particle separation than a tall-and-narrow one. An inclined inlet conduit plays an inessential role on the efficiency improvement but gains a 2 µm reduction in d 100. Comparing the simulated results, the hydrocyclone used in the experiments of this study exhibits a higher separation sharpness than the Rietema type and a higher efficiency than the Bradley type based on the same operation capacity and hydrocyclone size.  相似文献   

20.
Bubble characteristics in a three‐dimension gas‐fluidized bed (FB) have been measured using noninvasive ultrafast electron beam X‐ray tomography. The measurements are compared with predictions by a two‐fluid model (TFM) based on kinetic theory of granular flow. The effect of bed material (glass, alumina, and low linear density polyethylene (LLDPE), dp ~1 mm), inlet gas velocity, and initial particle bed height on the bubble behavior is investigated in a cylindrical column of 0.1‐m diameter. The bubble rise velocity is determined by cross correlation of images from dual horizontal planes. The bubble characteristics depend highly upon the particle collisional properties. The bubble sizes obtained from experiments and simulations show good agreement. The LLDPE particles show high gas hold‐up and higher bubble rise velocity than predicted on basis of literature correlations. The bed expansion is relatively high for LLDPE particles. The X‐ray tomography and TFM results provide in‐depth understanding of bubble behavior in FBs containing different granular material types. © 2014 American Institute of Chemical Engineers AIChE J, 60: 1632–1644, 2014  相似文献   