首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The electric charge of the radon decay product, 218Po, has an influence on its mobility characterised by the diffusion coefficient, which chiefly controls the formation of the radioactive aerosol by attachment and the plateout processes on surfaces. These processes strongly affect the dose relevant quantities like concentration and particle size distribution of the short-lived radon decay products. The neutralisation rate of the positive 218Po ions in environmental air was determined quantitatively in chamber experiments. The experimental results show the great influence of the ionisation rate and the humidity concentration on the neutralisation rate of the 218Po ions in air. The obtained neutralisation rates were described by equations, taking into account the neutralisation processes like ion recombination, charge transfer and electron scavenging. In 'normal' environmental air with an ionisation rate of 45 muR.h(-1) = 1.16 x 10(-8) C/(kg.h) and a relative humidity of 50% (T = 20 degrees C), a neutralisation rate of the 218Po ions of 1.54 x 10(-2) s(-1) was obtained. Taking into account this neutralisation rate leads to a fraction of about 51% of the Po cluster that are neutral in air.  相似文献   

2.
Different parameters enter models of the human respiratory tract. The unattached fraction of the radon progeny was identified as the most important parameter, with the strongest influence on lung dose. The unattached fraction depends on the indoor aerosol concentration and other environmental conditions. The recoil factor, p, which influences the unattached fraction of 214Pb and 214Bi, defined as the average detachment probability from the aerosol after an alpha decay of 218Po, has almost always been taken as a constant. Here the recoil factor was recalculated under different assumptions and found to be in the range between 0.1 and 0.8. A smaller recoil factor means lower unattached fractions of 214Pb and 214Bi. The influence of the recoil factor on lung dose was also estimated. The lung dose is smaller by about 10% if p = 0.1 is assumed in calculating the unattached fraction instead of p = 0.8.  相似文献   

3.
The present work focuses on assessing the influence of biological and aerosol parameters on human lung dose. The dose conversion factor (DCF), which gives the relationship between the effective dose and the potential alpha energy concentration of inhaled short-lived radon progeny (218Po, 214Pb, 214Bi/214Po) is estimated using a dosimetric approach related to the International Commission on Radiological Protection(ICRP). The calculations are based on the measurements of the distribution of activity size of indoor radon progeny, their unattached fraction (f(b)) and potential alpha energy concentration (E). These experimental data are measured using a low-pressure cascade impactor and a wire-screen diffusion battery. Because of the short half-lives of the investigated nuclides, modifications that simplify the dose calculation are possible. The radioactive aerosol and biological parameters are varied in order to assess the DCF arising from the uncertainty of these parameters. The main emphasis is on the variation of the ventilation rate, breathing mode, critical cells for the induction of lung cancer and the parameters of the attached and unattached activity size distribution of the radon progeny. The investigation shows that the DCF is more than a factor of two higher than the values recommended by the ICRP, namely 3.9 mSv WLM(-1) for the public and 5.1 mSv WLM(-1) for working places. The dose results for indoor aerosol conditions are in the range 2.3-2.6 mSv WLM(-1) depending on the breathing mode.  相似文献   

4.
A radon detector of pulse-ionization chamber (PIC) type could have some sensitivity for thoron. Thus, the presence of thoron could interfere with precise measurement of radon. In the present study, effects of thoron on the most common type of PIC detector (commercial name AlphaGUARD) were investigated using an exposure chamber. The AlphaGUARD was exposed to a mixture of radon and thoron, together with a radon/thoron discriminative monitor that employs a silicon solid-state detector. The thoron sensitivity of the PIC detector was estimated by comparing the two detectors. As a result, the thoron sensitivity was about 10% compared with the radon sensitivity. In other words, the radon concentration (Bq m(-3)) measured with the PIC detector was approximately the sum of the actual radon concentration (Bq m(-3)) and 10% of the thoron concentration (Bq m(-3)). The sensitivity to thoron should be considered in measurements in thoron-enhanced areas.  相似文献   

5.
The dose per exposure unit of the short-lived radon and thoron decay products was calculated using a dosimetric approach. The calculations are based on a lung dose model with the structure that is related to the ICRP 66 respiratory tract model. The dose relevant parameters, unattached fraction of the decay product clusters (fp) and size distribution of the unattached and aerosol-attached decay products for different living and working places are reported. Taking into account these characteristics the dose conversion factors (DCF) of the radon and thoron decay products were estimated. In addition, the living and working places were divided concerning their aerosol parameters like particle number concentration and activity size distribution.  相似文献   

6.
In addition to the workers in uranium mines, the staff of other underground mines, such as workers in underground phosphate mines, can be exposed to 222Rn and its progeny. In this study the individual radon progeny concentrations were measured in three Egyptian underground phosphate mines to estimate the occupational exposure of the workers at those sites. A filter method was used to measure individual radon progeny concentrations (218Po, 214Pb and 214Po). The reported mean values of radon progeny concentrations exceed the action levels which are recommended by ICRP 65 (1993). Based on the measured individual radon progeny concentrations (218Po, 214Pb and 214Po) in these mines, the annual effective dose for the workers has been calculated using the lung dose model of ICRP 66 (1994). According to the obtained results, some countermeasures were recommended in this study to minimise these exposure levels.  相似文献   

7.
Commercial hair gel material (polyvinyl pyrolydone triethanolamine carbopol in water) and bacteriological agar (phycocolloid extracted from a group of red-purple algae, usually Gelidium sp.) have been studied as radioactive radon gas detectors. The detection method is based on the diffusion of the radioactive gas in the gel material, and the subsequent measurement of trapped products of the natural decay of radon by gamma spectrometry. From the several radon daughters with gamma radiation emission (214Pb, 214Bi, 214Po, 210Pb, 210Po), two elements, 214Pb (0.352 MeV) and 214Bi (0.609 MeV), were chosen for the analysis in this work; in order to determine the best sensitivity, corrections were made for the short half-life of the analysed isotopes. For the gamma spectrometry analysis, a hyperpure germanium solid state detector was used, associated with a PC multichannel analyser card with Maestro and Microsoft Excel software. The results show the viability of the method: a linear response in a wide radon concentration range (450-10,000 Bq m(-3)), reproducibility of data, easy handling and low cost of the gel material. This detection methodology opens new possibilities for measurements of radon and other radioactive gases.  相似文献   

8.
Seven nose breathing and seven mouth breathing volunteers were exposed to atmospheres enriched with unattached radon progeny (218Po, 214Pb and 214Bi). The activity of these radionuclides deposited in the respiratory tract was measured in vivo after the exposures. The results of these measurements are in agreement with predictions calculated with the ICRP Publication 66 Human Respiratory Tract Model. Temporal analysis of the activity deposited in the heads of the volunteers leads to the conclusion that a significant amount of the deposited activity associated with particle diameters of about 1 nm is not subject to a fast transport to the gastrointestinal tract as generally reported for larger aerosol particles.  相似文献   

9.
Prior work studying radon progeny in a small enclosed chamber found that at high (222)Rn concentrations an enhanced surface deposition was observed. Subsequent measurements for unfiltered air showed minimal charged particle mobility influence. Progeny particle size measurements reported here, performed at the US Department of Energy Environmental Measurement Laboratory (now with Home Security Department), using the EML graded screen array (GSA) system show in unfiltered air that the high (222)Rn levels causes a reduction in the attached (218)Po progeny airborne particulates and formation of additional normal sized unattached ( approximately 0.80 nm) and also even smaller (218)Po below 0.50 nm. At a (222)Rn level of 51 kBq m(-3), 73% of all (218)Po are of a mean particle diameter of about 0.40 +/- 0.02 nm. At this (222)Rn level, the ratio of (218)Po to (222)Rn airborne concentrations is reduced significantly from the concentration ratio at low (222)Rn levels. Similar reductions and size reformations were observed for the (214)Pb and (214)Bi/Po progeny. The particle size changes are further confirmed using the plateout rates and corresponding deposition velocities. The Crump and Seinfeld deposition theory provides the corresponding particle diffusion coefficients. With the diffusion coefficient to ultrafine clustered particle diameter correlation of Ramamurthi and Hopke, good agreement is obtained between EML GSA and deposition velocity data down to 0.40 nm. Strong evidence is presented that the progeny size reduction is due to, as a result of air ionization, the increased neutralization rate (primarily from electron scavenging of OH molecules) of the initially charged progeny. This is shown to increase with the (1/2) power of (222)Rn concentration and relative humidity as well as increased air change rate in the chamber. These results imply that at (222)Rn levels above 50 kBq m(-3), at relative humidity of 52%, a considerable reduction in lung dose could occur from preferential deposition of the progeny in the nasal and oral passages.  相似文献   

10.
CFD modelling of thoron and thoron progeny in the indoor environment   总被引:1,自引:0,他引:1  
Thoron (220Rn) exhalation from building materials has become increasingly recognised as a potential source for radiation exposure in residences. However, contrary to radon (222Rn), limited information on thoron exposure is available. The purpose of this study is to estimate the concentration of thoron and its progeny products in a typical Dutch living room using computational fluid dynamics. The predicted thoron concentration is ~9 Bq m(-3) using a source term of 14 Bq s(-1) for the thoron exhalation from building materials. The concentration varies from 15 Bq m(-3) near the building materials to 2.7 Bq m(-3) in the centre of the living room. The mean effective dose from thoron progeny is calculated as 0.09 mSv y(-1), with a total effective dose from radon and thoron progeny of 0.38 mSv y(-1).  相似文献   

11.
Hungarian detectors modified and developed at the National Institute of Radiological Sciences (NIRS), Japan were placed at different sites, including homes and underground workplaces in Hungary, in order to gain information on the average radon (222Rn) and thoron (220Rn) concentration levels. Measurements were carried out in dwellings in a village and a manganese mine in Hungary. The radon and thoron concentrations in the dwellings of the village in the summer period were found to be 154 (17-1083) and 98 (1-714) Bq m(-3), respectively. Considering the results of other radon measurements during the winter (814 Bq m(-3)) and summer (182 Bq m(-3)) periods, the thoron concentrations were also expected to be higher in winter. In the manganese mine, radon and thoron were measured at 20 points for 6 months, changing the detectors each month. The averages were 924 (308-1639) and 221 (61-510) Bq m(-3) for radon and thoron, respectively. These results showed significant variance with the date and place of the measurement.  相似文献   

12.
Measurements of radon, thoron and their progeny were carried out in some houses from Garhwal and Kumaun Himalayas of India using a LR-115 plastic track detector. The measurements were made in various residential houses of the area at a height of 2.5 m above the ground level using a twin chamber radon dosemeter, which can record the values of radon, thoron and their progeny separately. The concentrations of radon and thoron in these homes were found to vary from 11 to 191 and 1 to 156 Bq m(-3), respectively. The equilibrium factor between radon and progeny varies from 0.02 to 0.90, with an average of 0.26 for the region. The resulting dose rate due to radon, thoron and their decay products was found to vary from 0.02 to 0.84 μSv h(-1) with an arithmetic mean of 0.27 μSv h(-1). A detailed analysis of the distribution of radon, thoron and their decay products inside a house is also reported. The observed dose rates due to radon, thoron and progeny were found somewhat higher but well below the international recommendations.  相似文献   

13.
Simultaneous indoor radon, radon-thoron progeny and high-resolution in situ gamma spectrometry measurements, with portable high-purity Ge detector were performed in 26 dwellings of Thessaloniki, the second largest town of Greece, during March 2003-January 2005. The radon gas was measured with an AlphaGUARD ionisation chamber (in each of the 26 dwellings) every 10 min, for a time period between 7 and 10 d. Most of the values of radon gas concentration are between 20 and 30 Bq m(-3), with an arithmetic mean of 34 Bq m(-3). The maximum measured value of radon gas concentration is 516 Bq m(-3). The comparison between the radon gas measurements, performed with AlphaGUARD and short-term electret ionisation chamber, shows very good agreement, taking into account the relative short time period of the measurement and the relative low radon gas concentration. Radon and thoron progeny were measured with a SILENA (model 4s) instrument. From the radon and radon progeny measurements, the equilibrium factor F could be deduced. Most of the measurements of the equilibrium factor are within the range 0.4-0.5. The mean value of the equilibrium factor F is 0.49 +/- 0.10, i.e. close to the typical value of 0.4 adopted by UNSCEAR. The mean equilibrium equivalent thoron concentration measured in the 26 dwellings is EEC(thoron) = 1.38 +/- 0.79 Bq m(-3). The mean equilibrium equivalent thoron to radon ratio concentration, measured in the 26 dwellings, is 0.1 +/- 0.06. The mean total absorbed dose rate in air, owing to gamma radiation, is 58 +/- 12 nGy h(-1). The contribution of the different radionuclides to the total indoor gamma dose rate in air is 38% due to 40K, 36% due to thorium series and 26% due to uranium series. The annual effective dose, due to the different source terms (radon, thoron and external gamma radiation), is 1.05, 0.39 and 0.28 mSv, respectively.  相似文献   

14.
On the case of a parallel metrological measurement of unattached and attached concentrations of radon progeny, the evaluation by an inversion of the Jacobi-Porstend?rfer room model indicates a real overestimation of the concentration of RaA ((218)Po).  相似文献   

15.
The monitoring of radon exposure at workplaces is of great importance. Up to now passive measurement systems have been used for the registration of radon gas. Recently an electronic radon gas personal dosemeter came onto the market as an active measurement system for the registration of radon exposure (DOSEman; Sarad GmbH, Dresden, Germany). In this personal monitor, the radon gas diffuses through a membrane into a measurement chamber. A silicon detector system records spectroscopically the alpha decays of the radon gas and of the short-lived progeny 218Po and 214Po gathered onto the detector by an electrical field. In this work the calibration was tested and a proficiency test of this equipment was made. The diffusion behaviour of the radon gas into the measurement chamber, susceptibility to thoron, efficiency, influence of humidity, accuracy and the detection limit were checked.  相似文献   

16.
To estimate annual average concentrations in Korean dwellings and the effective dose to the general public, nationwide surveys on radon were conducted in 1989, 1999-2000 and 2002-2005. The total number of dwellings was about 5600. A survey of thoron and its decay products was also conducted in 2002-2005. In 2008-2009, a new radon survey in 1100 public buildings was conducted. The annual arithmetic (AM) and geometric (GM) means of indoor radon concentration in total were 62.1 ± 66.4 and 49.0 ± 1.9 Bq m(-3), respectively. The annual AM and GM means of indoor thoron concentrations were 40.4 ± 56.0 and 10.7 ± 2.9 Bq m(-3), respectively. The radon and thoron concentrations in detached houses were much higher than those in apartments. The locations of the high radon or thoron houses seem to be correlated with the concentrations of their parent nuclides in surface soil. The mean individual doses of radon and thoron were calculated to be 1.65 and 0.17 mSv y(-1), respectively.  相似文献   

17.
Uranium and thorium series radionuclides are present in all soils and rocks. Thus, radon and thoron, the radioactive noble gases originating in the uranium ((238)U) and thorium ((232)Th) decay chains is ubiquitous and everyone is exposed to both radon and thoron gases and their particulate radioactive decay products. As described in UNSCEAR Annex E (2006), radon and its decay products have been recognised for many years as a hazard to underground miners. More recently, the risks from exposure to residential radon have been demonstrated through residential case-control epidemiological studies. However, as discussed by UNSCEAR, exposures to thoron and its decay products have often been relatively ignored. Moreover, unlike radon the effects of exposure to thoron and its decay products are not available from epidemiology and thus, a dosimetric approach is required to assess risks. UNSCEAR continues to recommend the use of a dose conversion factor for thoron decay products of 40 nSv (Bq h m(-3))(-1). UNSCEAR Annex E suggests there is an emerging problem, namely, that the contribution of (220)Rn (thoron) gas to the (222)Rn (radon) gas measurement signal is not well known. Until recently, this has largely been ignored. This is an important consideration as measurements at work and homes are the basis for investigating lung cancer exposure-response relationships. Based on UNSCEAR Annex E, this paper provides an overview of the sources and levels of thoron and its associated decay products at home and work. In addition, this paper provides an overview of the thoron dosimetry considered by UNSCEAR Annex E and some recent results.  相似文献   

18.
Naturally occurring isotopes of radon in indoor air are identified as the second leading cause of lung cancer after tobacco smoking. Radon-222 (radon gas) and radon-220 (thoron gas) are the most common isotopes of radon. While extensive radon surveys have been conducted, indoor thoron data are very limited. To better assess thoron exposure in Canada, radon/thoron discriminating detectors were deployed in 45 homes in Fredericton and 65 homes in Halifax for a period of 3 months. In this study, radon concentrations ranged from 16 to 1374 Bq m(-3) with a geometric mean (GM) of 82 Bq m(-3) and a geometric standard deviation (GSD) of 2.56 in Fredericton, and from 4 to 2341 Bq m(-3) with a GM of 107 Bq m(-3) and a GSD of 3.67 in Halifax. It is estimated that 18 % of Fredericton homes and 32 % of Halifax homes could have radon concentrations above the Canadian indoor radon guideline of 200 Bq m(-3). This conclusion is significantly higher than the previous estimates made 30 y ago with short-term radon measurements. Thoron concentrations were below the detection limit in 62 % of homes in both cities. Among the homes with detectable thoron concentrations, the values varied from 12 to 1977 Bq m(-3) in Fredericton and from 6 to 206 Bq m(-3) in Halifax. The GM and GSD were 86 Bq m(-3) and 3.19 for Fredericton, and 35 Bq m(-3) and 2.35 for Halifax, respectively. On the basis of these results, together with previous measurements in Ottawa, Winnipeg and the Mont-Laurier region of Quebec, it is estimated that thoron contributes ~8 % of the radiation dose due to indoor radon exposure in Canada.  相似文献   

19.
Long-term (circa 3 months) simultaneous measurements of indoor concentrations of thoron gas, airborne thoron progeny and radon were made using passive alpha track detectors in 205 dwellings in Ireland during the period 2007-09. Thoron progeny concentrations were measured using passive deposition monitors designed at the National Institute of Radiological Sciences (NIRS), Japan, whereas thoron gas concentrations were measured using Raduet detectors (Radosys, Budapest). Radon concentrations were measured in these dwellings by means of NRPB/SSI type alpha track radon detectors as normally used by the Radiological Protection Institute of Ireland (RPII). The concentration of thoron gas ranged from <1 to 174 Bq m(-3) with an arithmetic mean (AM) of 22 Bq m(-3). The concentration of radon gas ranged from 4 to 767 Bq m(-3) with an AM of 75 Bq m(-3). For radon, the estimated annual doses were 0.1 (min), 19.2 (max) and 1.9 (AM) mSv y(-1). The concentration of thoron progeny ranged from <0.1 to 3.8 Bq m(-3) [equilibrium equivalent thoron concentration (EETC)] with an AM of 0.47 Bq m(-3) (EETC). The corresponding estimated annual doses were 2.9 (max) and 0.35 (mean) mSv y(-1). In 14 or 7% of the dwellings, the estimated doses from thoron progeny exceeded those from radon.  相似文献   

20.
In the first part of this work, the potential alpha energy concentration (PAEC) of radon progeny, the equilibrium factor (F), the activity concentration of 222Rn gas (Co) and the unattached fraction (fp), were determined in 15 living rooms at El-Minia City, Egypt. The activity size distribution of (214)Pb was measured by using a low pressure Berner impactor. Based on the parameters of that distribution the total effective dose through the human lung was evaluated by using a dosimetric model calculation of ICRP. An electrostatic precipitation method was used for the determination of 222Rn gas concentration. The mean activity concentration of 222Rn gas (Co) was found to be 123 +/- 22 Bq m(-3). A mean unattached fraction (fp) of 0.11 +/- 0.02 was obtained at a mean aerosol particle concentration (Z) of (3.0 +/- 0.21) x 10(3) cm(-3). The mean equilibrium factor (F) was determined to be 0.35 +/- 0.03. The mean PAEC was found to be 37 +/- 8.1 Bq m(-3). The activity size distribution of (214)Pb shows mean activity median diameter of 290 nm with mean geometric standard deviation (sigma) of 2.45. At a total deposition fraction of approximately 23% the total effective dose to the lung was determined to be approximately 1.2 mSv. The second part of this paper deals with a study of natural radionuclide contents of samples collected from the building materials of those rooms under investigation given in part one of this paper. Analyses were performed in Marinelli beakers with a gamma multichannel analyser provided with a NaI(Tl) detector. The samples have revealed the presence of the uranium-radium and thorium radioisotopes as well as (40)K. Nine gamma-lines of the natural radioisotopes that correspond to 212Pb, 214Pb, 214Bi, 228Ac, 40K and 208Tl were detected and measured. The activity concentrations of 226Ra, 232Th and 40K were determined with mean specific activities of 65 +/- 22, 35 +/- 12 and 150 +/- 60 Bq kg(-1), respectively. These activities amount to a radium equivalent (Ra(eq)) of 126 Bq kg(-1) and to a mean value of external hazard index of 0.34.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏