首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The electron-trapping probability in OSL traps as a function of irradiation temperature is investigated for sedimentary quartz and feldspar. A dependency was found for both minerals; this phenomenon could give rise to errors in dose estimation when the irradiation temperature used in laboratory procedures is different from that in the natural environment. No evidence was found for the existence of shallow trap saturation effects that could give rise to a dose-rate dependency of electron trapping.  相似文献   

2.
The reliability of equivalent-dose determinations on quartz made with the single-aliquot regenerative-dose (SAR) protocol is examined using a suite of sedimentary samples for which the equivalent dose is expected to be >200 Gy. Experiments on one sample were used to evaluate the precision obtained using the standard measurement procedure with (a) a range of pre-heat temperatures, and (b) a single pre-heat temperature. The precision is compared with that achieved using SAR for a repeated dose point after an initial pre-heat, and for a known dose given before the initial pre-heat. It is concluded that, at least for this sample, the scatter in OSL measurements dominates the spread in the estimates of De.  相似文献   

3.
We have developed a system to irradiate samples and record radioluminescence (RL), optically stimulated luminescence (OSL), and thermoluminescence (TL) at temperatures ranging from -150 degrees C to 200 degrees C. The system consists of a cryostat, an irradiation/stimulation unit fitted with an X-ray tube (40 kV Moxtek) and a quartz window for optical stimulation, and a detection unit that utilises a photomultiplier tube and an interchangeable filter pack. Experiments have been conducted with quartz and albite (a feldspar). TL and OSL experiments show that several optically sensitive trapping states are stable below -50 degrees C. In addition, an increase in OSL is seen as the OSL stimulation temperature is lowered below -50 degrees C, and an increase in RL is apparent as the temperature is lowered during irradiation. This indicates that not only are optically sensitive low temperature traps present but that luminescence becomes more efficient at low temperatures.  相似文献   

4.
Thermal treatment before optically stimulated luminescence (OSL) measurement is an important step in all widely accepted OSL dating procedures used with quartz. This is a major constraint on the design of a portable luminescence instrument for estimating ages in the field. Preliminary experiments show that using a standard dating protocol without heating caused a 30-50% underestimation of equivalent dose. This underestimate arises mainly from OSL derived from the 110 degrees C thermoluminescence (TL) trap; because of the thermal instability of this trap, this OSL contribution is only present in unheated laboratory-regenerated signals, but not in the natural signal. An alternative to thermal pre-treatment is investigated, based on the mathematical separation of the stable dosimetry OSL signal from the total OSL; the latter is the sum of signals from several traps, including the 110 degrees C TL trap. Our results show consistency with dose estimates obtained using a standard measurement protocol including pre-heating.  相似文献   

5.
In the development of techniques for the retrospective assessment of the dose absorbed by communities living and working adjacent to the site of a nuclear accident, attention has concentrated on the use of natural minerals such as quartz and feldspar as dosemeters. These minerals are widely found in household earthenware and almost all types of bricks and concrete. Their main disadvantages are variable and often low sensitivity, and the possibility of a comparatively large natural dose prior to the accident, depending on the age of the building and the type or building material. However, there are other potential unheated crystalline materials found in the domestic and industrial environment which may also act as retrospective dosemeters, and may be considerably more sensitive. We have surveyed the thermoluminescent and optically stimulated luminescent (OSL) characteristics of several such chemicals and this paper reports on the OSL sensitivity, the size of the residual dose immediately after manufacture, stability and derived minimum detection limits.  相似文献   

6.
Lime mortars mixed with sand are well suited for connecting structural materials, like stones and bricks, due to the mechanical properties this material exhibits. Their extensive use in architectural and decorative works during the last 4000 years motivated the introduction of the 'Luminescence clock' for age determination of mortars. The same principles as for quartz optically stimulated luminescence (OSL) dating of sediments were applied for age estimation of a mortar fragment removed from a Byzantine church monument dated by archaeological means to 1050-1100 years ago (the first half of the 10th century). The OSL from the quartz was monitored under blue light stimulation and UV detection, using a single-aliquot-regenerative-dose protocol. The quartz-OSL dating of the mortar resulted in 870 +/- 230 a. TL polymineral fine grain dating was also performed on a brick fragment which was connected to the mortar, resulting in a TL age of 1095 +/- 190 a.  相似文献   

7.
Since the beginning of the 1990s the exploration of optically stimulated luminescence (OSL) in retrospective accident dosimetry has driven an intensive investigation and development programme at Ris? into measurement facilities and techniques. This paper reviews some of the outcomes of this programme, including the evaluation of the single-aliquot regenerative-dose (SAR) measurement protocol with brick quartz and the determination of dose-depth profiles in building materials as a guide to determining the mean energy of the incident radiation. Investigations into heated materials are most advanced, and a lower detection limit for quartz extracted from Chernobyl bricks was determined to be <10 mGy. The first results from the measurement of doses in unheated building materials such as mortar and concrete are also discussed. Both small-aliquot and single-grain techniques have been used to assess accident doses in these cement based building materials more commonly found in workplaces. Finally some results of a preliminary investigation of the OSL properties of household chemicals are discussed with reference to their potential as accident dosemeters.  相似文献   

8.
We present the first quartz optically stimulated luminescence (OSL) ages for palaeochannel sediments from the Riverine Plain in southeastern Australia. For young fluvial sediments, we agree with the notion that analysis of the leading edge of a dose distribution curve provides an objective method for determining the OSL age. For a modern flood deposit (less than 200 years old), the OSL ages estimated using the leading edge method (250 +/- 50 years) and by using the lowest 5% of the measured dose in single aliquots (230 +/- 50 years) agree within experimental errors. For older sediments, we suggest that the mean estimate of the dose distribution is likely to provide a reliable estimate of the OSL age. The luminescence ages suggest that the Coleambally and Kerarbury palaeochannel systems were active between 105 and 80 ky and 55 and 35 thousand years ago; the Yanco palaeochannel system could have been active as recently as 9000 years ago.  相似文献   

9.
The single-aliquot regenerative-dose (SAR) protocols used in retrospective dosimetry for optically stimulated luminescence measurements have been mainly developed for archaeological and geological dating of quartz and feldspar. The aim in this study is to find a read-out protocol that can generate the most reproducible signal for household salt (NaCl) at absorbed doses below 100 mGy. The relation between the reproducibility of the signal, in terms of the ratio between given absorbed dose and SAR-calculated dose, and parameters such as test-dose pre-heat temperature has been studied. It was found that a temperature of 200 °C yielded the best reproducibility in the SAR-calculated dose, which is a somewhat higher pre-heat temperature than what is used for dating of quartz.  相似文献   

10.
Food irradiation is extremely effective at reducing food-borne illness as well as losses caused by infestation and contamination. Despite the well-established regulations that permit irradiation to control pathogens in spices, there are no widespread methods to detect previously irradiated food. Therefore, it has become necessary to develop new detection and dose determination methods for food subjected previously to irradiation. The present work deals with the application of the thermoluminescence (TL) phenomenon to detect irradiated spices. The process is based upon the thermoluminescence properties exhibited by the polymineral content of the irradiated specimen. After separating the organic material, it is possible to extract some polymineral substances that are suitable for thermoluminescence analysis due to interaction of the spice to ionising radiation. The method was successfully applied to examine irradiated and non-irradiated paprika of Mexican origin. The spice was irradiated with gamma rays at doses of 5, 10 and 15 kGy. The separated thermoluminescent polymineral was found to be composed mainly of quartz and feldspar. The thermoluminescence glow curve of the irradiated specimen shows a wide band peaked 228, 268 and 336 degrees C, resembling closely the combined TL of quartz and feldspars. The method allows for the determination of the retrospective dose exposure.  相似文献   

11.
In a recent paper Bailey proposed a general model to describe many optically stimulated luminescence (OSL) and thermoluminescence properties of natural quartz. This model consists of five electron trapping centres and four recombination centres: one of the recombination centres is assumed to be radiative and the remaining non-radiative. This paper investigates some additional aspects of the Bailey model. Firstly, the single-aliquot regenerative-dose (SAR) method has been simulated using the model. It is shown that the simulated natural dose (2 Gy) given to the 'sample' in the simulation can be estimated to within approximately 2% using the SAR method. Furthermore, sensitivity-corrected OSL growth curves have been calculated over a dose range of 0 to 2500 Gy. Using the model, it is also demonstrated that the shape of the sensitivity-corrected OSL growth curve is independent of dose rate, for dose rates of 0.001 Gy x s(-1) and 0.1 Gy x s(-1), over a dose range of 0-500 Gy.  相似文献   

12.
This paper presents two different approaches of quantifying the optically stimulated luminescence (OSL) response of Al(2)O(3):C to high-energy heavy charged particles (HCPs). The OSL efficiency of Al(2)O(3):C exposed to different HCPs is defined as the sensitivity of the material to HCPs normalised by the sensitivity to gamma. In this paper, we investigate the possibility of introducing a 'mean efficiency' eta(mean), which when used in conjunction with the total gamma dose D(gamma) measured for a mixed radiation exposure allows for the determination of the absorbed dose without the need to determine the individual contributions of different types of radiation to the OSL signal. We tested the hypothesis that information regarding the 'mean efficiency' eta(mean) is contained in the shape of the OSL decay curve, using several approaches in the analysis of the OSL data. This analysis was applied to various mixed field irradiations performed at the HIMAC facility, Chiba, Japan. The results of this analysis are discussed.  相似文献   

13.
An objective methodology for dose distribution analysis   总被引:1,自引:0,他引:1  
The advent of single aliquot optically stimulated luminescence (OSL) techniques along with parallel equipment advances have made it possible and practical to obtain statistically meaningful quantities of equivalent dose (De) data from individual samples. Now that hundreds of dose determinations can be made for one sample De distributions may be scrutinised, leading to the problem of how to make unbiased comparisons among distributions, and how to decide objectively which dose is representative of the age of the deposit. In this paper, an objective analytical method is presented for treating dose distributions, including a mathematically rigorous means of determining a representative equivalent dose and a statistical definition of its corresponding uncertainty. This analytical method has been applied to Holocene aeolian and fluvial quartz sands from Central Oklahoma. The results are compared to equivalent doses determined via other proposed analytical procedures.  相似文献   

14.
Most attempts to apply retrospective dosimetry to building materials have made use of heated (sensitised) items such as brick or tile ceramic. Unfired materials, such as concrete, are far more widespread in the industrial environment, but unfortunately these cannot be assumed to contain a negligible dose at the time of construction. This paper reports on preliminary attempts to measure, using optically stimulated luminescence (OSL), a dose-depth profile in a new concrete brick which had been given a known dose in the laboratory. The dose distribution in individual samples was measured before and after irradiation using small aliquots each of 65 quartz grains, and also using single grains, extracted from the concrete. Despite the material being very poorly zeroed prior to irradiation, both approaches gave satisfactory results and it is concluded that measurement of individual grains from poorly zeroed building materials can provide useful information on accident doses.  相似文献   

15.
Results of a study of optically and thermally stimulated luminescence (OSL and TL) of thin nanostructured aluminum oxide coatings obtained with evaporation of the target by a pulsed electron beam and deposited on quartz glass, Al, steel, Cu, Ta, and graphite wafers are presented. It follows from data of X-ray phase analysis that the obtained Al2O3 layers have an amorphous nanocrystal structure with different contents of the γ phase depending on the geometry of the wafer location on evaporation and annealing temperature of the samples. It is established that the material of the wafer and the ratio of the amorphous and γ phase in Al2O3 layers affect the yields of OSL and TL. Annealing at up to 970 K results in an increase of γ-phase concentration and OSL and TL responses. It was found that the yields of OSL and TL for the most emission-effective coating samples are comparable with those for the detectors on the basis of anion-defective corundum. The dose-dependence for β radiation, which was linear in the range 20–5000 mGy, was investigated.  相似文献   

16.
Three different methods for characterising the dose deposition profile of a (90)Sr/(90)Y radioactive source are described: GAFChromic film dosimetry, Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL). For the film measurements, GAFChromic film samples were stacked at different depths between polyethylene terephthalate (PET) foils. For TL, the thickness of a TLD-500 dosemeter was gradually reduced by polishing and the TL from chips of different thickness was used in conjunction with a mathematical model based on the exponential attenuation of dose inside the crystal to determine the decay constant for the dose-depth profile. Finally, an OSL reader with confocal stimulation / detection capabilities was used to map the two-dimensional dose distribution in TLD-500 dosemeters as a function of depth. The shapes of the dose deposition profiles obtained from all the investigated methods are in good agreement.  相似文献   

17.
Optically stimulated luminescence (OSL) has become the technique of choice in many areas of dosimetry. Natural materials like topaz are available in large quantities in Brazil and other countries. They have been studied to investigate the possibility of use its thermoluminescence (TL) properties for dosimetric applications. In this work, we investigate the possibility of utilising the OSL properties of natural Brazilian topaz in dosimetry. Bulk topaz samples were exposed to doses up to 100 Gy of beta radiation and the integrated OSL as a function of the dose showed linear behaviour. The fading occurs in the first 20 min after irradiation but it is <6% of the integrated OSL measured shortly after exposure. We conclude that natural colourless topaz is a very suitable phosphor for OSL dosimetry.  相似文献   

18.
The characteristics of thermoluminescence (TL) and optical stimulated luminescence (OSL) in undoped alpha-Al2O3 single crystals were studied. The TL glow curves of the crystal samples irradiated at various dose levels were measured by Ris? TL/OSL-DA-15B/C reader with U-340 or 7-59 filters at different heating rates. The glow peaks measured with U-340 at approximately 210 degrees C of the undoped alpha-Al2O3 can be well fitted by first-order kinetic equation whereas the glow peaks measured with 7-59 filters are a composite of two first-order glow peaks. It indicates that the TL glow curves are dependent upon the filter used in the reader that is related to the emission spectra of luminescence materials. The OSL were also measured and fitted by two exponential functions to get the luminescence intensities. The TL and OSL dose responses of the undoped alpha-Al2O3 crystal were obtained in the dose range of 0.12-248 Gy and fitted by the composite action dose-response function to get nonlinear characteristic parameters. The TL and OSL dose responses are linear-sublinear.  相似文献   

19.
The thermoluminescence (TL) and optically stimulated luminescence (OSL) of SrSO4:Eu (0.1 mol%) powder sample were studied. The TL and OSL emission spectrum are measured after irradiation (absorbed dose 100 Gy) of 90Sr source; both of them showed that the emission wavelength is at approximately 375 nm, which indicates that TL and OSL have the same luminescence centres, and the luminescence comes from transitions between the energy levels of Eu2+. The TL glow curves and OSL decay curves illustrate that there is only one main TL peak but two main components in OSL curves. By a comparative study of TL and OSL it is concluded that OSL traps are different from TL traps. The TL and OSL dose responses of SrSO4:Eu phosphor were measured, and it showed that phosphor has similar dose responses for OSL and TL.  相似文献   

20.
为了高附加值地利用铁尾矿,实验以铁尾矿、页岩和云母为基材并添加适量的长石和发泡剂,通过烧结的方法制备铁尾矿基多孔保温材料。采用TGA法分析云母和页岩掺量对粉料低共熔温度和烧成温度的影响,利用XRD、SEM研究云母和页岩比例的变化对铁尾矿基多孔保温材料矿物组成和形貌的影响。结果表明云母-页岩二元体系中云母含量的增加会降低试样的低共熔温度和烧成温度;页岩含量的增加能促使更多的石英参与反应生成斜长石,试样中斜长石的含量略有增加,石英则有所降低;试样内部含有大量分布均匀的气孔,最大孔的孔径约为2mm,在大气孔之间和内部存在许多小气孔。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号