首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Hourly mean wind-speed data for the period 1986–1997 [except the years 1989 (some data is missing) and 1991 (Gulf War)] recorded at the solar radiation and meteorological monitoring station, Dhahran (26°C 32′ N, 50° 13′ E), Saudi Arabia, have been analyzed to investigate the optimum size of battery storage capacity for hybrid (wind+diesel) energy conversion systems at Dhahran. The monthly average wind speeds for Dhahran range from 4.12 to 6.42 m/s. As a case study, the hybrid system considered in the present analysis consists of two 10 kW Wind Energy Conversion Systems (WECS), together with a battery storage system and a diesel back-up. The yearly and monthly average energy generated from the above hybrid system have been presented. More importantly, the study explores the impact of variation of battery storage capacity on hybrid power generation. The results exhibit a trade-off between size of the storage capacity and diesel power to be generated to cope with specific annual load distribution [41,500], and for given energy generation from WECS. The energy to be generated from the back-up diesel generator and the number of operational hours of the diesel system to meet a specific annual electrical energy demand have also been presented. The diesel back-up system is operated at times when the power generated from WECS fails to satisfy the load and when the battery storage is depleted. The present study shows that for economic considerations, for optimum use of battery storage and for optimum operation of diesel system, storage capacity equivalent to one to three days of maximum monthly average daily demand needs to be used. It has been found that the diesel energy to be generated without any storage is considerably high; however, use of one day of battery storage reduces diesel energy generation by about 35%; also the number of hours of operation of the diesel system are reduced by about 52%.  相似文献   

2.
《Applied Energy》2009,86(2):163-169
Solar energy and wind energy are the two most viable renewable energy resources in the world. Good compensation characters are usually found between solar energy and wind energy. This paper recommend an optimal design model for designing hybrid solar–wind systems employing battery banks for calculating the system optimum configurations and ensuring that the annualized cost of the systems is minimized while satisfying the custom required loss of power supply probability (LPSP). The five decision variables included in the optimization process are the PV module number, PV module slope angle, wind turbine number, wind turbine installation height and battery capacity. The proposed method has been applied to design a hybrid system to supply power for a telecommunication relay station along south-east coast of China. The research and project monitoring results of the hybrid project were reported, good complementary characteristics between the solar and wind energy were found, and the hybrid system turned out to be able to perform very well as expected throughout the year with the battery over-discharge situations seldom occurred.  相似文献   

3.
Integration of wind machines and battery storage with the diesel plants is pursued widely to reduce dependence on fossil fuels. The aim of this study is to assess the impact of battery storage on the economics of hybrid wind‐diesel power systems in commercial applications by analyzing wind‐speed data of Dhahran, East‐Coast, Kingdom of Saudi Arabia (K.S.A.). The annual load of a typical commercial building is 620,000 kWh. The monthly average wind speeds range from 3.3 to 5.6 m/s. The hybrid systems simulated consist of different combinations of 100‐kW commercial wind machines (CWMs) supplemented with battery storage and diesel generators. National Renewable Energy Laboratory's (NREL's) (HOMER Energy's) Hybrid Optimization Model for Electric Renewables (HOMER) software has been employed to perform the economic analysis. The simulation results indicate that for a hybrid system comprising of 100‐kW wind capacity together with 175‐kW diesel system and a battery storage of 4 h of autonomy (i.e. 4 h of average load), the wind penetration (at 37‐m hub height, with 0% annual capacity shortage) is 25%. The cost of generating energy (COE, $/kWh) from this hybrid wind–battery–diesel system has been found to be 0.139 $/kWh (assuming diesel fuel price of 0.1$/L). The investigation examines the effect of wind/battery penetration on: COE, operational hours of diesel gensets. Emphasis has also been placed on un‐met load, excess electricity, fuel savings and reduction in carbon emissions (for wind–diesel without battery storage, wind–diesel with storage, as compared to diesel‐only situation), cost of wind–battery–diesel systems, COE of different hybrid systems, etc. The study addresses benefits of incorporation of short‐term battery storage (in wind–diesel systems) in terms of fuel savings, diesel operation time, carbon emissions, and excess energy. The percentage fuel savings by using above hybrid system is 27% as compared to diesel‐only situation Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

4.
The storage and balancing needs of a simplified European power system, which is based on wind and solar power generation only, are derived from an extensive weather-driven modeling of hourly power mismatches between generation and load. The storage energy capacity, the annual balancing energy and the balancing power are found to depend significantly on the mixing ratio between wind and solar power generation. They decrease strongly with the overall excess generation. At 50% excess generation the required long-term storage energy capacity and annual balancing energy amount to 1% of the annual consumption. The required balancing power turns out to be 25% of the average hourly load. These numbers are in agreement with current hydro storage lakes in Scandinavia and the Alps, as well as with potential hydrogen storage in mostly North-German salt caverns.  相似文献   

5.
从风光互补系统的经济性出发研究了风光互补系统的优化设计问题。以年度平均电量成本最小化作为目标,将太阳能光伏板面积、风电机组额定功率和蓄电池最大储能容量作为决策变量,构建了风光互补系统优化设计模型,并通过引入互补约束条件,将分段函数转化为连续函数,利用改进的拉格朗日分解法,由上而下分阶段求解模型。实例应用结果表明,利用优化模型计算所得结果在经济性和运算效率上有明显提高,验证了模型的可行性和算法的有效性。  相似文献   

6.
This paper aims to show the use of the response surface methodology (RSM) in size optimization of an autonomous PV/wind integrated hybrid energy system with battery storage. RSM is a collection of statistical and mathematical methods which relies on optimization of response surface with design parameters. In this study, the response surface, output performance measure, is the hybrid system cost, and the design parameters are the PV size, wind turbine rotor swept area and the battery capacity. The case study is realized in ARENA 10.0, a commercial simulation software, for satisfaction of electricity consumption of the global system for mobile communications (GSM) base station at Izmir Institute of Technology Campus Area, Urla, Turkey. As a result, the optimum PV area, wind turbine rotor swept area, and battery capacity are obtained to be 3.95 m2, 29.4 m2, 31.92 kWh, respectively. These results led to $37,033.9 hybrid energy system cost, including auxiliary energy cost. The optimum result obtained by RSM is confirmed using loss of load probability (LLP) and autonomy analysis.  相似文献   

7.
System power reliability under varying weather conditions and the corresponding system cost are the two main concerns for designing hybrid solar–wind power generation systems. This paper recommends an optimal sizing method to optimize the configurations of a hybrid solar–wind system employing battery banks. Based on a genetic algorithm (GA), which has the ability to attain the global optimum with relative computational simplicity, one optimal sizing method was developed to calculate the optimum system configuration that can achieve the customers required loss of power supply probability (LPSP) with a minimum annualized cost of system (ACS). The decision variables included in the optimization process are the PV module number, wind turbine number, battery number, PV module slope angle and wind turbine installation height. The proposed method has been applied to the analysis of a hybrid system which supplies power for a telecommunication relay station, and good optimization performance has been found. Furthermore, the relationships between system power reliability and system configurations were also given.  相似文献   

8.
As non-polluting reliable energy sources, stand-alone photovoltaic/wind/fuel cell (PV/wind/FC) hybrid systems are being studied from various aspects in recent years. In such systems, optimum sizing is the main issue for having a cost-effective system. This paper evaluates the performance of different artificial intelligence (AI) techniques for optimum sizing of a PV/wind/FC hybrid system to continuously satisfy the load demand with the minimal total annual cost. For this aim, the sizing problem is formulated and four well-known heuristic algorithms, namely, particle swarm optimization (PSO), tabu search (TS), simulated annealing (SA), and harmony search (HS), are applied to the system and the results are compared in terms of the total annual cost. It can be seen that not only average results produced by PSO are more promising than those of the other algorithms but also PSO has the most robustness. As another investigation, the sizing is also performed for a PV/wind/battery hybrid system and the results are compared with those of the PV/wind/FC system.  相似文献   

9.
This paper presents an optimum sizing methodology to optimize the hybrid energy system (HES) configuration based on genetic algorithm. The proposed optimization model has been applied to evaluate the techno‐economic prospective of the HES to meet the load demand of a remote village in the northern part of Saudi Arabia. The optimum configuration is not achieved only by selecting the combination with the lowest cost but also by finding a suitable renewable energy fraction that satisfies load demand requirements with zero rejected loads. Moreover, the economic, technical and environmental characteristics of nine different HES configurations were investigated and weighed against their performance. The simulation results indicated that the optimum wind turbine (WT) selection is not affected only by the WT speed parameters or by the WT rated power but also by the desired renewable energy fraction. It was found that the rated speed of the WT has a significant effect on optimum WT selection, whereas the WT rated power has no consistent effect on optimal WT selection. Moreover, the results clearly indicated that the HES consisting of photovoltaics (PV), WT, battery bank (Batt) and diesel generator (DG) has superiority over all the nine systems studied here in terms of economical and environmental performance. The PV/Batt/DG hybrid system is only feasible when wind resource is very limited and solar energy density is high. On the other hand, the WT/Batt/DG hybrid system is only feasible at high wind speed and low solar energy density. It was also found that the inclusion of batteries reduced the required DG and hence reduced fuel consumption and operating and maintenance cost. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Recently, there has been a growing interest in harnessing renewable energy resources particularly for electricity generation. One of the main concerns in the design of an electric power system that utilizes renewable energy sources, is the accurate selection of system components that can economically satisfy the load demand. This depends on the load that ought to be met, the capacity of renewable resources, the available space for wind machines and solar panels, and the capital and running costs of system components. Once size optimization is achieved, the autonomous system must be controlled in order to correcly match load requirements with instantaneous variation of input energy. In this paper, a new formulation for optimizing the design of an autonomous wind-solar-diesel-battery energy system is developed. This formultation employs linear programming techniques to minimize the average production cost of electricity while meeting the load requirements in a reliable manner. The computer program developed reads the necessary input data, formulates the optimization problem by computing the coefficients of the objective function and the constraints and provides the optimum wind, solar, diesel, and battery ratings. In order to study the effect of parameters predefined by the designer on the optimum design, several sensitivity analysis studies are performed, and the effects of the expected energy not served, the load level, the maximum available wind area, the maximum available solar area, and the diesel engines' lifetime are investigated. A controller the monitors the operation of the autonomous system is designed. The operation of this controller is based on three major policies; in the first, batteries operate before diesel engines and hence the storage system acts as a fuel saver, while in the second diesel engines are operated first so that the unmet energy is lower but the fuel cost is high. According to the third policy, the supply is made through diesel engines only. This is done for the purpose of making a performance comparison between the isolated diesel system and the hybrid renewable energy system. The proposed optimization and control techniques are tested on Lebanese data. Although three different control policies have been adopted in this work, the software is able to accommodate other policies.  相似文献   

11.
The sizing and techno-economical optimization of a stand-alone hybrid photovoltaic/wind system (HPWS) with battery storage is presented in this paper. The main objective of the present study is to find the optimum size of system, able to fulfill the energy requirements of a given load distribution, for three sites located at Corsica island and to analyze the impact of different parameters on the system size. The methodology used provides a useful and simple approach for sizing and analyzing an HPWS. In the proposed stand-alone system, a new concept such as the supply of wind power via a uninterruptible power supply (UPS) is introduced and therefore the energy produced by the wind generator can be sent directly to the load.  相似文献   

12.
The combined utilization of renewables such as solar and wind energy is becoming increasingly attractive and is being widely used for substitution of oil-produced energy, and eventually to reduce air pollution. In the present investigation, hourly wind-speed and solar radiation measurements made at the solar radiation and meteorological monitoring station, Dhahran (26°32′N, 50°13′E), Saudi Arabia, have been analyzed to study the impact of key parameters such as photovoltaic (PV) array area, number of wind machines, and battery storage capacity on the operation of hybrid (wind + solar + diesel) energy conversion systems, while satisfying a specific annual load of 41,500 kWh. The monthly average wind speeds for Dhahran range from 4.1 to 6.4 m/s. The monthly average daily values of solar radiation for Dhahran range from 3.6 to 7.96 kWh/m2. Parametric analysis indicates that with two 10 kW wind machines together with three days of battery storage and photovoltaic deployment of 30 m2, the diesel back-up system has to provide about 23% of the load demand. However, with elimination of battery storage, about 48% of the load needs to be provided by diesel system.  相似文献   

13.
In this paper, size of a PV/wind integrated hybrid energy system with battery storage is optimized under various loads and unit cost of auxiliary energy sources. The optimization is completed by a simulation based optimization procedure, OptQuest, which integrates various heuristic methods. In the study, the main performance measure is the hybrid energy system cost. And the design parameters are PV size, wind turbine rotor swept area and the battery capacity. The case study is realized for Izmir Institute of Technology Campus Area, Urla, Turkey. The simulation model of the system is realized in ARENA 12.0, a commercial simulation software, and is optimized using the OptQuest tool in this software. Consequently, the optimum sizes of PV, wind turbine and battery capacity are obtained under various auxiliary energy unit costs and two different loads. The optimum results are confirmed using Loss of Load Probability (LLP) and autonomy analysis. And the investment costs are investigated how they are shared among those four energy sources at the optimum points.  相似文献   

14.
《Energy》2005,30(5):555-572
The average annual increase in electricity consumption and peak demand in Northern Cyprus (N. Cyprus) during the past 20 years have been 7.1 and 5.5%, respectively. In recent years, the demand for electricity has been stretched to its limits in winter. This raised the question of whether renewable energy resources could be utilized to reduce the level of peak demand. Indeed, Cyprus being a Mediterranean island, enjoys an abundance of solar energy, and preliminary studies showed that a considerable potential of wind energy is also available. Utilization of renewable energy for space heating, water heating, pumping and power generation would increase electrical reserve margins, raise system load factor, improve load following capabilities, and reduce the need for capacity expansion. Currently, solar water heating which leads to a saving of at least 72 GWh energy per annum and a significant reduction in CO2 emission has been extensively used in N. Cyprus. In N. Cyprus, despite the availability of renewable energy resources constructing renewable base-load, electrical power stations has not been found feasible. However, constructing such systems is recommended for two reasons: firstly, as a supplement to saving fuel and secondly, expanding capacity. In this context, the economic analysis for both solar and wind energy systems, has shown a reasonable internal rate of return (IRR). Although, the IRR is higher for wind energy systems, the availability of wind is limited to a few locations and therefore energy distribution is required.  相似文献   

15.
In this paper, a methodology for calculation of the optimum size of a battery bank and the PV array for a standalone hybrid wind/PV power system is developed. Long term data of wind speed and irradiance recorded for every hour of the day for 30 years were used. These data were used to calculate the average power generated by a wind turbine and a PV module for every hour of a typical day in a month. A load of a typical house in Massachusetts, USA, was used as a load demand of the hybrid system. For a given load and a desired loss of power supply probability, an optimum number of batteries and PV modules was calculated based on the minimum cost of the power system  相似文献   

16.
This paper presents the results of investigations on the application of wind, photovoltaic (PV), and hybrid wind/PV power generating systems for utilization as stand-alone systems. A simple numerical algorithm has been developed for generation unit sizing. It has been used to determine the optimum generation capacity and storage needed for a stand-alone, wind, PV, and hybrid wind/PV system for an experimental site in a remote area in Montana with a typical residential load. Generation and storage units for each system are properly sized in order to meet the annual load and minimize the total annual cost to the customer. In addition, an economic analysis has been performed for the above three scenarios and is used to justify the use of renewable energy versus constructing a line extension from the nearest existing power line to supply the load with conventional power. Annual average hourly values for load, wind speed, and insolation have been used  相似文献   

17.
A methodology is developed for calculating the correct size of a photovoltaic (PV)-hybrid system and for optimizing its management. The power for the hybrid system comes from PV panels and an engine-generator – that is, a gasoline or diesel engine driving an electrical generator. The combined system is a stand-alone or autonomous system, in the sense that no third energy source is brought in to meet the load. Two parameters were used to characterize the role of the engine-generator: denoted SDM and SAR, they are, respectively, the battery charge threshold at which it is started up, and the storage capacity threshold at which it is stopped, both expressed as a percentage of the nominal battery storage capacity. The methodology developed is applied to designing a PV-hybrid system operating in Corsica, as a case study. Various sizing configurations were simulated, and the optimal configuration that meets the autonomy constraint (no loss of load) was determined, by minimizing of the energy cost. The influence of the battery storage capacity on the solar contribution is also studied. The smallest energy cost per kWh was obtained for a system characterized by an SDM=30% and an SAR=70%. A study on the effects of component lifetimes on the economics of PV-hybrid and PV stand-alone systems has shown that battery size can be reduced by a factor of two in PV-hybrid systems, as compared to PV stand-alone systems.  相似文献   

18.
《Energy Conversion and Management》2005,46(15-16):2501-2513
In view of rising costs, pollution and fears of exhaustion of oil and coal, governments around the world are encouraging to seek energy from renewable/sustainable energy sources such as wind. The utilization of energy from wind (since the oil embargo of the 1970s) is being widely disseminated for displacement of fossil fuel produced energy and to reduce atmospheric degradation. A system that consists of a wind turbine and Diesel genset is called a Wind–Diesel power system.The literature indicates that the commercial/residential buildings in Saudi Arabia consume an estimated 10–40% of the total electric energy generated. In the present study, the hourly mean wind-speed data of the period 1986–1997 recorded at the solar radiation and meteorological station, Dhahran (26°32′N, 50°13′E in the Eastern Coastal Region of Saudi Arabia), has been analyzed to investigate the potential of utilizing hybrid (Wind–Diesel) energy conversion systems to meet the load requirements of a hundred typical two bedroom residential buildings (with annual electrical energy demand of 3512 MWh). The long term monthly average wind speeds for Dhahran range from 4.2 to 6.4 m/s. The hybrid systems considered in the present case study consist of different combinations/clusters of 150 kW commercial wind machines supplemented with battery storage and Diesel back-up. The deficit energy generated by the Diesel generator (for different battery capacities) and the number of operational hours of the Diesel system to meet a specific annual electrical energy demand of 3512 MWh have also been presented. The evaluation of the hybrid system shows that with seven 150 kW wind energy conversion system (WECS) and one day of battery storage, the Diesel back-up system has to provide 21.6% of the load demand. Furthermore, with three days of battery storage, the Diesel back-up system has to provide 17.5% of the load demand. However, in the absence of battery storage, about 37% of the load needs to be provided by the Diesel system. The study also places emphasis on the monthly average daily energy generation from different sizes (150 kW, 250 kW, 600 kW) of wind machines to identify the optimum wind machine size from the energy production point of view. It has been noted that for a given 6 MW wind farm size (for 50 m hub height), a cluster of forty 150 kW wind machines yields about 48% more energy as compared to a cluster of ten 600 kW wind machines.  相似文献   

19.
Junji Kondoh 《风能》2010,13(6):529-541
Output power fluctuation of high penetration of wind power causes demand and supply imbalance in electric power systems and results in frequency deviation if the fluctuation is not fully compensated by other regulable power plants. In Japan, some electric utilities have started to accept only the wind farms which disconnect and give up generating power during light‐load periods with less adjustable reserve. Otherwise, wind farms are required to employ battery energy storage systems (BESSs) to charge the generated power during the light‐load periods. Instead of these uneconomical solutions, this paper proposes autonomous frequency regulation by controllable loads such as electric water heaters (EWHs). In the paper, the acceptable increase of wind power generation by the proposed load control has been evaluated quantitatively in the power system of the Hokkaido Island in Japan. The result indicates that the acceptable increase of wind power generation goes from 250 to 675 MW by applying the proposed autonomous frequency regulation on all EWHs, and the total cost to implement the autonomous frequency regulation on the EWHs is around 1/26 compared with a solution using BESSs. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Depleting oil and gas reserves, combined with growing concerns of atmospheric pollution/degradation, have made the search for energy from renewable sources of energy, such as solar and wind, inevitable. Literature indicates that commercial/residential buildings in Saudi Arabia consume an estimated 10–40% of the total electric energy generated. In the present study, hourly mean wind-speed and solar radiation data for the period 1986–1997 recorded at the solar radiation and meteorological monitoring station, Dhahran (26°32′ N, 50°13′ E), Saudi Arabia, have been analyzed to investigate the potential of utilizing hybrid (wind+solar) energy conversion systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620 000 kWh). The monthly average wind speeds for Dhahran range from 4.1 to 6.4 m/s. The monthly average daily values of solar radiation for Dhahran range from 3.6 kWh/m2 to 7.96 kWh/m2. The hybrid systems considered in the present analysis consist of different combinations of commercial 10 kW wind energy conversion systems (WECS), photovoltaic (PV) panels supplemented with battery storage unit and diesel back-up. The study shows that with 30 10-kW WECS together with 150 m2 PV, and 3 days of battery storage, the diesel back-up system has to provide 17% of the load demand. However, in the absence of battery storage, about 38% of the load needs to be provided by the diesel system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号