首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The plasma diagnostic method using the transmission attenuation of microwaves at double frequencies (PDMUTAMDF) indicates that the frequency and the electron-neutral collision frequency of the plasma can be deduced by utilizing the transmission attenuation of microwaves at two neighboring frequencies in a non-magnetized plasma. Then the electron density can be obtained from the plasma frequency. The PDMUTAMDF is a simple method to diagnose the plasma indirectly. In this paper, the interaction of electromagnetic waves and the plasma is analyzed. Then, based on the attenuation and the phase shift of a microwave in the plasma, the principle of the PDMUTAMDF is presented. With the diagnostic method, the spatially mean electron density and electron collision frequency of the plasma can be obtained. This method is suitable for the elementary diagnosis of the atmospheric-pressure plasma.  相似文献   

2.
The propagation of the high-power microwave (HPM) with a frequency of 6 GHz in the low-pressure argon plasma was studied by the method of fluid approximation.The two-dimensional transmission model was built based on the wave equation,the electron drift-diffusion equations and the heavy species transport equations,which were solved by means of COMSOL Multiphysics software.The simulation results showed that the propagation characteristic of the HPM was closely related to the average electron density of the plasma.The attenuation of the transmitted wave increased nonlinearly with the electron density.Specifically,the growth of the attenuation slowed down as the electron density increased uniformly.In addition,the concrete transmission process of the HPM wave in the low-pressure argon plasma was given.  相似文献   

3.
As advanced linear plasma sources, cascaded arc plasma devices have been used to generate steady plasma with high electron density, high particle flux and low electron temperature. To measure electron density and electron temperature of the plasma device accurately, a laser Thomson scattering(LTS) system, which is generally recognized as the most precise plasma diagnostic method, has been established in our lab in Dalian University of Technology. The electron density has been measured successfully in the region of 4.5?×?10(19)m~(-3) to7.1?×?10~(20)m~(-3) and electron temperature in the region of 0.18 eV to 0.58 eV. For comparison,an optical emission spectroscopy(OES) system was established as well. The results showed that the electron excitation temperature(configuration temperature) measured by OES is significantly higher than the electron temperature(kinetic electron temperature) measured by LTS by up to 40% in the given discharge conditions. The results indicate that the cascaded arc plasma is recombining plasma and it is not in local thermodynamic equilibrium(LTE). This leads to significant error using OES when characterizing the electron temperature in a non-LTE plasma.  相似文献   

4.
This paper reports the use of machine learning to enhance the diagnosis of a dusty plasma. Dust in a plasma has a large impact on the properties of the plasma. According to a probe diagnostic experiment on a dust-free plasma combined with machine learning, an experiment on a dusty plasma is designed and carried out. Using a specific experimental device, dusty plasma with a stable and controllable dust particle density is generated. A Langmuir probe is used to measure the electron density and electron temperature under different pressures, discharge currents, and dust particle densities. The diagnostic result is processed through a machine learning algorithm,and the error of the predicted results under different pressures and discharge currents is analyzed,from which the law of the machine learning results changing with the pressure and discharge current is obtained. Finally, the results are compared with theoretical simulations to further analyze the properties of the electron density and temperature of the dusty plasma.  相似文献   

5.
Plasma source is the most important part of the laboratory plasma platform for fundamental plasma experimental research. Barium oxide coated cathode plasma source is well recognized as an effective technique due to its high electron emission current. An indirectly heated oxide coated cathode plasma source has been constructed on a linear magnetized plasma device. The electron emission current density can reach 2 A/cm 2 to 6 A/cm 2 in pulsed mode within pulse length 5–20 ms. A 10 cm diameter, 2 m long plasma column with density 10 18 m −3 to 10 19 m 3 and electron temperature Te ≈ 3–7 eV is produced. The spatial uniformity of the emission ability is less than 4% and the discharge reproducibility is better than 97%. With a wide range of the plasma parameters, this kind of plasma source provides great flexibility for many basic plasma investigations. The detail of construction and initial characterization of oxide coated cathode are described in this paper.  相似文献   

6.
The coaxial surface wave linear plasma with preeminent axial uniformity is developed with the 2.45 GHz microwave generator. By optical emission spectroscopy, parameters of the argon linear plasma with a length over 600 mm are diagnosed under gas pressure of 30 and 50 Pa and different microwave powers. The spectral lines of argon and Hβ (486.1 nm) atoms in excited state are observed for estimating electron excitation temperature and electron density. Spectrum bands in 305–310 nm of diatomic OH (${{\rm{A}}}^{2}{{\rm{\Sigma }}}^{+}-{{\rm{X}}}^{2}{{\rm{\Pi }}}_{{\rm{i}}}$) radicals are used to determine the molecule rotational temperature. Finally, the axial uniformity of electron density and electron excitation temperature are analyzed emphatically under various conditions. The results prove the distinct optimization of compensation from dual powers input, which can narrow the uniform coefficient of electron density and electron excitation temperature by around 40% and 22% respectively. With the microwave power increasing, the axial uniformity of both electron density and electron excitation temperature performs better. Nevertheless, the fluctuation of electron density along the axial direction appeared with higher gas pressure. The axial uniformity of coaxial surface wave linear plasma could be controlled by pressure and power for a better utilization in material processing.  相似文献   

7.
In this work,microwaves and terahertz waves have performed a dual-frequency combineddiagnosis in high-temperature,large-scale plasma.According to the attenuation and phase shift of electromagnetic waves in the plasma,the electron density and collision frequency of theplasma can be inversely calculated.However,when the plasma size is large and the electron density is high,the phase shift of the electromagnetic wave is large (multiple times 2π period).Due to the limitations of the test equipment,the true phase shift is difficult to test accurately or to recover reality.That is,there is a problem of phase integer ambiguity.In order to obtain a phase shift of less than 180°,a higher electromagnetic wave frequency (terahertz wave with 890 GHz)is used for diagnosis.However,the attenuation of the terahertz wave diagnosis is too small (less than 0.1 d B),only the electron density can be obtained,and the collision frequency cannot be accurately obtained.Therefore,a combined diagnosis was carried out by combining twofrequencies (microwave with 36 GHz,terahertz wave with 890 GHz) to obtain electron density and collision frequency.The diagnosis result shows that the electron density is in the range of(0.65–1.5)×10~(19)m~(-3),the collision frequency is in the range of 0.65–2 GHz,and the diagnostic accuracy is about 60%.  相似文献   

8.
The argon plasma induced by the L-/C-band high-power microwave(HPM) is investigated theoretically and experimentally. Influences of the microwave power, pulse width, polarization and the plasma electron density on the protection performance of the plasma array against HPM are studied. The results show that the effect of HPM is caused by energy accumulation, with the gas breakdown emerging only after a short time. The attenuation of the wave by the plasma array with the tubes off can reach approximately 23 dB at 1.3 GHz. It can also be obtained that the protection performance of the plasma array against the TE wave is better than that against the TM one. The plasma array shows better protection performance in the L-band than in the C-band. In addition,the attenuation of 5.6 GHz HPM can reach 30 dB when the tubes are turned on in the experiment.The research shows that the plasma array has protection ability against HPM.  相似文献   

9.
A method is proposed to built up plasma based on a nonlinear enhancement phenomenon of plasma density with discharge by multiple internal antennas simultaneously. It turns out that the plasma density under multiple sources is higher than the linear summation of the density under each source. This effect is helpful to reduce the fast exponential decay of plasma density in single internal inductively coupled plasma source and generating a larger-area plasma with multiple internal inductively coupled plasma sources. After a careful study on the balance between the enhancement and the decay of plasma density in experiments, a plasma is built up by four sources, which proves the feasibility of this method. According to the method, more sources and more intensive enhancement effect can be employed to further build up a high-density, large-area plasma for different applications.  相似文献   

10.
Stimulated Raman scattering(SRS)in a longitudinal magnetized plasma is studied by theoretical analysis and kinetic simulation.The linear growth rate derived via one-dimensional fluid theory shows the dependence on the plasma density,electron temperature,and magnetic field intensity.One-dimensional particle-in-cell simulations are carried out to examine the kinetic evolution of SRS under low magnetic intensity of ωc/ω0<0.01.There are two density regions distinguished in which the absolute growth of enveloped electrostatic waves and spectrum present quite different characteristics.In a relatively low-density plasma(ne~0.20nc),the plasma wave presents typical absolute growth and the magnetic field alleviates linear SRS.While in the plasma whose density is near the cut-off point(ne~0.23nc),the magnetic field induces a spectral splitting of the backscattering and forward-scattering waves.It has been observed in simulations and verified by theoretical analysis.Due to this effect,the onset of reflectivity delays,and the plasma waves form high-frequency oscillation and periodic envelope structure.The split wavenumber Δk/k0 is proportional to the magnetic field intensity and plasma density.These studies provide novel insight into the kinetic behavior of SRS in magnetized plasmas.  相似文献   

11.
This work reports spectroscopic studies of uranium containing plasma generated in air and argon environments. The 532 nm Q-switched Nd:YAG laser generates the optical breakdown plasma, which was recorded by a spectrometer and an intensified charge coupled device having a resolution of 25 pm. Neutral and ionized uranium lines in the wavelength range of 385.8–391.9 nm indicate significant width and shift variations during the first few microseconds. Electron temperature and density of the plasma are determined using the Boltzmann plot and the Saha–Boltzmann equation at various time delay. The study reveals the power law decay pattern of electron temperature and density, which changes to exponential decay pattern if large gate- width is used to acquire the signal, due to an averaging effect.  相似文献   

12.
A high-flux linear plasma device in Sichuan University plasma-surface interaction(SCU-PSI)based on a cascaded arc source has been established to simulate the interactions between helium and hydrogen plasma with the plasma-facing components in fusion reactors.In this paper,the helium plasma has been characterized by a double-pin Langmuir probe.The results show that the stable helium plasma beam with a diameter of 26 mm was constrained very well at a magnetic field strength of 0.3 T.The core density and ion flux of helium plasma have a strong dependence on the applied current,magnetic field strength and gas flow rate.It could reach an electron density of1.2?×?10~(19)m~(-3)and helium ion flux of 3.2?×?10~(22)m~(-2)s~(-1),with a gas flow rate of 4 standard liter per minute,magnetic field strength of 0.2 T and input power of 11 k W.With the addition of-80 Vapplied to the target to increase the helium ion energy and the exposure time of 2 h,the flat top temperature reached about 530°C.The different sizes of nanostructured fuzz on irradiated tungsten and molybdenum samples surfaces under the bombardment of helium ions were observed by scanning electron microscopy.These results measured in the SCU-PSI linear device provide a reference for International Thermonuclear Experimental Reactor related PSI research.  相似文献   

13.
We report spectroscopic studies on plasma electron number density of laser-induced plasma produced by ns-Nd:YAG laser light pulses on an aluminum sample in air at atmospheric pressure.The effect of different laser energy and the effect of different laser wavelengths were compared.The experimentally observed line profiles of neutral aluminum have been used to extract the excitation temperature using the Boltzmann plot method,whereas the electron number density has been determined from the Stark broadened as well as using the Saha-Boltzmann equation(SBE).Each approach was also carried out by using the Al emission line and Mg emission lines.It was observed that the SBE method generated a little higher electron number density value than the Stark broadening method,but within the experimental uncertainty range.Comparisons of N_e determined by the two methods show the presence of a linear relation which is independent of laser energy or laser wavelength.These results show the applicability of the SBE method for N_e determination,especially when the system does not have any pure emission lines whose electron impact factor is known.Also use of Mg lines gives superior results than Al lines.  相似文献   

14.
Diagnosis of the particle number density of plasma plays an important role in the understanding of plasma sources and processing.Regular radiation signals from plasma oscillation in filaments of atmospheric nitrogen discharge,which were excited by the injection of secondary electron beams during the propagation of the streamer,are employed to determine the ion density of plasma and its evolution in the filaments.Results show that the density of N_4~+ in a filament of atmospheric nitrogen discharge is of the order of 10~(13) cm~(-3).It is also found that the recombination processes play a dominant role in plasma decay,and that the ion density decreases non-monotonically with time during streamer propagation.  相似文献   

15.
Effect of electron-ion collision on stimulated Raman backward scattering (SRBS) spectrum are investigated by numerical simulations. In the given parameters and plasma condition, the growth rates of SRBS are found to strongly depend on the electron density, and the gap in the SRBS spectrum corresponding to the high electron density could be explained by the collisional damping. In the low density region, a much higher Landau damping estimated by the linear theory makes the collisional damping negligible. However, the present results show that, collisions play a even more important role than known in the linear theory.  相似文献   

16.
射频感应等离子体制备球形Ti粉的工艺   总被引:3,自引:0,他引:3  
采用射频(RF)感应等离子体球化颗粒形状不规则的Ti颗粒。研究了加料速率、物料分散方式、Ti颗粒大小等因素对球化率的影响。电子扫描显微镜(SEM)观察的球化效果以及对钛粉振实密度的测定表明:当钛原粉以极短暂时间快速穿越等离子体炬时,钛粉颗粒因受热而熔化成液滴,快速冷却,形成球形固态颗粒。  相似文献   

17.
An electron Penning-Malmberg trap,which can confine an electron column and provide a good platform to investigate the cross-filed transportation of strongly magnetized electron plasma ,has been set up.With the device,an electron plasma with a density of 10^7 cm^-3 can be confined for a relatively long time.The structure of the trap,electron source,as well as the way how th measure electron plasma density profile and velocity distrbustion are introduced in detail.  相似文献   

18.
Dipole Research EXperiment(DREX) is a new terrella device as part of the Space Plasma Environment Research Facility(SPERF) for laboratory studies of space physics relevant to the inner magnetospheric plasmas. Adequate plasma sources are very important for DREX to achieve its scientific goals. According to different research requirements, there are two density regimes for DREX. The low density regime will be achieved by an electron cyclotron resonance(ECR) system for the ‘whistler/chorus' wave investigation, while the high density regime will be achieved by biased cold cathode discharge for the desired ‘Alfvén' wave study. The parameters of ‘whistler/chorus' waves and ‘Alfvén' waves are determined by the scaling law between space and laboratory plasmas in the current device. In this paper, the initial design of these two plasma sources for DREX is described. Focus is placed on the chosen frequency and operation mode of the ECR system which will produce relatively low density ‘artificial radiation belt' plasmas and the seed electrons, followed by the design of biased cold cathode discharge to generate plasma with high density.  相似文献   

19.
Stable operations of single direct current(DC) discharge, single radio frequency(RF) discharge and DC?+?RF hybrid discharge are achieved in a specially-designed DC enhanced inductivelycoupled plasma(DCE-ICP) source. Their plasma characteristics, such as electron density,electron temperature and the electron density spatial distribution profiles are investigated and compared experimentally at different gas pressures. It is found that under the condition of single RF discharge, the electron density distribution profiles show a ‘convex' shape and ‘saddle' shape at gas pressures of 3 m Torr and 150 m Torr respectively. This result can be attributed to the transition of electron kinetics from nonlocal to local kinetics with an increase in gas pressure.Moreover, in the operation of DC?+?RF hybrid discharge at different gas pressures, the DC discharge has different effects on plasma uniformity. The plasma uniformity can be improved by modulating DC power at a high pressure of 150 m Torr where local electron kinetics is dominant,whereas plasma uniformity deteriorates at a low pressure of 3 m Torr where nonlocal electron kinetics prevails. This phenomenon, as analyzed, is due to the obvious nonlinear enhancement effect of electron density at the chamber center, and the inherent radial distribution difference in the electron density with single RF discharge at different gas pressures.  相似文献   

20.
Lower hybrid heating (LHH) has been successfully carried out in the HT-6M tokamak.The H-mode has been obtained with a power threshold of 50kW under a boronized wall condition.Both energy and particle confinements have been improved along with a dropped edge plasma density and an increase electron temperature during the LHH phase.A negative Er well plays a key role of triggering and sustaining the good confinement.Both electrostatic fluctuation of the plasma potential and the density fluctuations dropped to an ultra-low level.The observation of an enhanced Er shear before the reduction in turbulence level is consistent with an increased Er shear as the cause of turbulence suppression.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号