首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Monitoring of ionising radiation around high-energy particle accelerators is a difficult task due to the complexity of the radiation field, which is made up of neutrons, charged hadrons, muons, photons and electrons, with energy spectra extending over a wide energy range. The dose-equivalent outside a thick shield is mainly owing to neutrons, with some contribution from photons and, to a minor extent, the other particles. Neutron dosimetry and spectrometry are thus of primary importance to correctly evaluate the exposure of personnel. This paper reviews the relevant techniques and instrumentation employed for monitoring radiation fields around high-energy proton accelerators, with particular emphasis on the recent development to increase the response of neutron measuring devices > 20 MeV. Rem-counters, pressurised ionisation chambers, superheated emulsions, tissue-equivalent proportional counters and Bonner sphere spectrometers are discussed.  相似文献   

2.
Recombination chambers and different recombination methods have been used for dosimetry of mixed radiation fields at high-energy accelerators for over 40 years. This paper gives a short overview of 11 selected recombination methods used for the determination of H*(10) in mixed radiation fields at high-energy accelerators. A new correction factor is proposed, mainly in order to take into account the dependence of the chamber sensitivity on radiation quality. This factor depends only on the measurable index of radiation quality and can be determined for a particular chamber during the calibration in a reference field of neutron radiation. A comparison of the results obtained at high-energy accelerators showed that all the methods gave the same values of H(10), within a specified accuracy of about 20%, so all of them are suitable for monitoring complex mixed radiation fields at workplaces.  相似文献   

3.
The monitoring of ambient doses at work places around high-energy accelerators is a challenging task due the complexity of the mixed stray radiation fields encountered. At CERN, mainly Centronics IG5 high-pressure ionisation chambers are used to monitor radiation exposure in mixed fields. The monitors are calibrated in the operational quantity ambient dose equivalent H*(10) using standard, source-generated photon- and neutron fields. However, the relationship between ionisation chamber reading and ambient dose equivalent in a mixed high-energy radiation field can only be assessed if the spectral response to every component and the field composition is known. Therefore, comprehensive studies were performed at the CERN-EU high-energy reference field facility where the spectral fluence for each particle type has been assessed with Monte Carlo simulations. Moreover, studies have been performed in an accessible controlled radiation area in the vicinity of a beam loss point of CERN's proton synchrotron. The comparison of measurements and calculations has shown reasonable agreement for most exposure conditions. The results indicate that conventionally calibrated ionisation chambers can give satisfactory response in terms of ambient dose equivalent in stray radiation fields at high-energy accelerators in many cases. These studies are one step towards establishing a method of 'field calibration' of radiation protection instruments in which Monte Carlo simulations will be used to establish a correct correlation between the response of specific detectors to a given high-energy radiation field.  相似文献   

4.
Radiation protection around CERN's high-energy accelerators represents a major challenge due to the presence of complex, mixed radiation fields. Behind thick shielding neutrons dominate and their energy ranges from fractions of eV to about 1 GeV. In this work the response of various portable detectors sensitive to neutrons was studied at CERN's High-Energy Reference Field Facility (CERF). The measurements were carried out with conventional rem counters, which usually cover neutron energies up to 20 MeV, the Thermo WENDI-2, which is specified to measure neutrons up to several GeV, and a tissue-equivalent proportional counter. The experimentally determined neutron dose equivalent results were compared with Monte Carlo (MC) simulations. Based on these studies field calibration factors can be determined, which result in a more reliable estimate of H(*)(10) in an unknown, but presumably similar high-energy field around an accelerator than a calibration factor determined in a radiation field of a reference neutron source.  相似文献   

5.
A reference facility for the calibration and intercomparison of active and passive detectors in broad neutron fields has been available at CERN since 1992. A positively charged hadron beam (a mixture of protons and pions) with momentum of 120 GeV/c hits a copper target, 50 cm thick and 7 cm in diameter. The secondary particles produced in the interaction traverse a shield, at 90 degrees with respect to the direction of the incoming beam. made of either 80 to 160 cm of concrete or 40 cm of iron. Behind the iron shield, the resulting neutron spectrum has a maximum at about 1 MeV, with an additional high-energy component. Behind the 80 cm concrete shield, the neutron spectrum has a second pronounced maximum at about 70 MeV and resembles the high-energy component of the radiation field created by cosmic rays at commercial flight altitudes. This paper describes the facility, reports on the latest neutron spectral measurements, gives an overview of the most important experiments performed by the various collaborating institutions over recent years and briefly addresses the possible application of the facility to measurements related to the space programme.  相似文献   

6.
At high-energy particle accelerators, area monitoring needs to be performed in a wide range of neutron energies. In principle, neutrons occur from thermal energies up to the energy of the accelerated ions, which is for the present GSI (Gesellschaft für Schwerionenforschung) accelerator facility approximately 1-2 GeV per nucleon. There are no passive dosemeters available, which are designed for the use at high-energy accelerators. At GSI, a neutron dosemeter was developed, which is suitable for the measurement of high-energy neutron radiation by the insertion of a lead layer around Thermoluminescence (TL) detection elements (pairs of TL 600/700) at the centre of the dosemeter. The design of the sphere was derived from the construction of the extended range rem-counters for the measurement of ambient dose equivalent H(10). In this work, the dosemeter fluence response was measured in the quasi-monoenergetic neutron fields of the accelerator facility of the PTB in Braunschweig and in the thermal neutron field of the GKSS research reactor FRG-1 in Geesthacht. For the accelerator measurements, the reactions (7)Li(p,n)(7)Be, (3)H(p,n)(3)He and (2)H(d,n)(3)He were used to produce neutron fields with energy peaks between 144 keV and 19 MeV. The measured fluence responses are 27% too low for thermal energies and show an agreement with approximately 14% for the accelerator produced neutron fields related to the computed fluence responses (MCNP, FLUKA calculations). The measured as well as the computed fluence responses of the dosemeter are compared with the corresponding conversion coefficients.  相似文献   

7.
Workplace monitoring is a common procedure for determining measures for routine radiation protection in a particular working environment. For mixed radiation fields consisting of neutrons and photons, it is of increased importance because it contributes to the improved accuracy of individual monitoring. An example is the determination of field-specific correction factors, which can be applied to the readings of personal dosemeters. This paper explains the general problems associated with individual dosimetry of neutron radiation, and describes the various options for workplace monitoring. These options cover a range from the elaborate field characterisation using transport calculations or spectrometers to the simpler approach using area monitors. Examples are given for workplaces in nuclear industry, at particle accelerators and at flight altitudes.  相似文献   

8.
The stray radiation field outside the shielding of high-energy accelerators comprises neutrons, photons and charged particles with a wide range of energies. Often, accelerators operate by accelerating and ejecting short pulses of particles, creating an analogue, pulsed radiation field. The pulses can be as short as 10 micros with high instantaneous fluence rates and dose rates. Measurements of average dose equivalent (rate) for radiation protection purposes in these fields present a challenge for instrumentation. The performance of three instruments (i.e. a recombination chamber, the Sievert Instrument and a HANDI-TEPC) measuring total dose equivalent is compared in a high-energy reference radiation field (CERF) and a strongly pulsed, high-energy radiation field at the CERN proton synchrotron (PS).  相似文献   

9.
Radiation protection dosimetry in radiation fields behind the shielding of high-energy accelerators such as CERN is a challenging task and the quantitative understanding of the detector response used for dosimetry is essential. Measurements with ionisation chambers are a standard method to determine absorbed dose (in the detector material). For applications in mixed radiation fields, ionisation chambers are often also calibrated in terms of ambient dose equivalent at conventional reference radiation fields. The response of a given ionisation chamber to the various particle types of a complex high-energy radiation field in terms of ambient dose equivalent depends of course on the materials used for the construction and the chamber gas used. This paper will present results of computational studies simulating the exposure of high-pressure ionisation chambers filled with different types of gases to the radiation field at CERN's CERN-EU high-energy reference field facility. At this facility complex high-energy radiation fields, similar to those produced by cosmic rays at flight altitudes, are produced. The particle fluence and spectra calculated with FLUKA Monte Carlo simulations have been benchmarked in several measurements. The results can be used to optimise the response of ionisation chambers for the measurement of ambient dose equivalent in high-energy mixed radiation fields.  相似文献   

10.
Unlike other fields of toxicology, radiation protection has a dual system of quantities, one set for assessment and the derivation of authorised limits and another set for monitoring radiation performance and compliance. Neutrons are an important or dominant constituent of the radiation field around high energy accelerators and the evolution of the radiation protection quantities used to measure neutrons is described. In 1990 ICRP introduced a new quantity, the effective dose. E. with which to express its protection limits. E represented a radical departure from previous advice of the Commission, particularly in the manner by which it weighted the absorbed dose deposited by high LET radiations. This advice had profound consequences for neutron dosimetry. Over the past decade analyses have revealed logical flaws and inconsistencies in the definition of effective dose. These are briefly discussed with most emphasis being placed on inconsistencies in radiation weighting. Suggestions are made with a view to resolving these inconsistencies.  相似文献   

11.
Due to the pronounced energy dependence of the neutron quality factor, accurate assessment of the biologically relevant dose requires knowledge of the spectral neutron fluence rate. Bonner sphere spectrometers (BSSs) are the only instruments which provide a sufficient response over practically the whole energy range of the cosmic ray induced neutron component. Measurements in a 62 MeV proton beam at Paul Scherrer Institute, Switzerland, and in the CERN-EU high-energy reference field led to the assumption that conventional active devices for the detection of thermal neutrons inside the BSS, e.g. 6Lil(Eu) scintillators, also respond to charged particles when used in high-energy mixed radiation fields. The effects of these particles cannot be suppressed by amplitude discrimination and are subsequently misinterpreted as neutron radiation. In contrast, paired TLD-600 and TLD-700 thermoluminescence dosemeters allow the determination of a net thermal neutron signal.  相似文献   

12.
Reliable measurement of neutron radiation is a difficult task due to the large energy range of neutrons, their complex and energy-dependent interaction mechanisms with matter and, consequently, the imperfect response characteristics of most instruments. Therefore, Calibration procedures and calibration facilities play an important role. Different types of calibration fields have been developed and made available at several institutions. The primary reference quantity used for the calibration of neutron measuring devices--area monitors, personal dosemeters, spectrometers, etc.--is the neutron fluence. This quantity is determined by appropriate experimental methods whereas dosimetric quantities are derived by applying recommended fluence-to-dose conversion coefficients. This paper summarises the basic principles underlying neutron production, the metrology employed to characterise the radiation fields and the calibration procedures employed. Examples of calibration facilities will be given, which enable routine calibrations, investigations of energy dependence and application-specific calibrations.  相似文献   

13.
The use of high-energy linear electron accelerators (LINACs) for medical cancer treatments is widespread on an international scale. The associated bremsstrahlung X rays may produce neutrons as a result of subsequent photonuclear reactions with the different materials constituting the accelerator head. The generated neutron field is highly variable and depends strongly on the beam energy, on the accelerator shielding, on the flattering filter as well as on the movable collimators (jaws) design and on the irradiation field geometry. An estimate of this photoneutron component is, thus, of practical interest to quantify the radiological risk for the working staff and patients. Due to high frequency electromagnetic fields, and also to the presence of abundant leaked and scattered photons in these installations, measurements of the corresponding neutron fields by active dosemeters are extremely difficult. A modified version of the Bonner sphere system, based on passive gold activation detectors, has been used to perform neutron measurements at two points in a Varian 2,100C LINAC facility. A home-made unfolding procedure (CDM) has been utilised to determine the neutron spectra present at the measurement points. Results indicate that the giant dipole resonance process is the most adequate model to explain neutron production in the LINAC and that a thermal component is present at the measurement points.  相似文献   

14.
The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments.In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to E<20 MeV if only polyethylene spheres are used, but can be extended to hundreds of MeV by including metal-loaded spheres (extended range BSS, indicated with ERBSS).With the aim of providing useful data to the scientific community involved in neutron measurements at hadron therapy facilities, an ERBSS experiment was carried out at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) of INFN—LNS (Laboratori Nazionali del Sud), where a proton beam routinely used for ophthalmic cancer treatments is available. The 62 MeV beam was directed towards a PMMA phantom, simulating the patient, and two neutron measurement points were established at 0° and 90° with respect to the beam-line. Here the ERBSS of UAB (Universidad Autónoma de Barcelona—Grup de Física de les Radiacions) and INFN (Istituto Nazionale di Fisica Nucleare—Laboratori Nazionali di Frascati) were exposed to characterize the “forward” and “sideward” proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and independently established and calibrated, is important for guaranteeing the robustness of the measured spectra and estimating their overall uncertainties.  相似文献   

15.
Neutrons can be produced with low-energy ion accelerators for many applications, such as the characterisation of neutron detectors, the irradiation of biological samples and the study of the radiation damage in electronic devices. Moreover, accelerator-based neutron sources are under development for boron neutron capture therapy (BNCT). Thin targets are used for generating monoenergetic neutrons, while thick targets are usually employed for producing more intense neutron fields. The associated photon field produced by the target nuclei may have a strong influence on the application under study. For instance, these photons can play a fundamental role in the design of an accelerator-based neutron source for BNCT. This work focuses on the measurement of the photon field associated with neutrons that are produced by 4.0-6.8 MeV protons striking both a thin 7LiF target (for generating monoenergetic neutrons) and a thick beryllium target. In both cases, very intense photon fields are generated with energy distribution extending up to several MeV.  相似文献   

16.
Selecting the instruments to determine the operational quantities in the neutron fields produced by particle accelerators involves a combination of aspects, which is peculiar to these environments: the energy distribution of the neutron field, the continuous or pulsed time structure of the beam, the presence of other radiations to which the neutron instruments could have significant response and the large variability in the dose rate, which can be observed when moving from areas near the beam line to free-access areas. The use of spectrometric techniques in support of traditional instruments is highly recommended to improve the accuracy of dosimetric evaluations. The multi-sphere or Bonner Sphere Spectrometer (BSS) is certainly the most used device, due to characteristics such as the wide energy range, large variety of active and passive detectors suited for different workplaces, good photon discrimination and the simple signal management. Disadvantages are the poor energy resolution, weight and need to sequentially irradiate the spheres, leading to usually long measurement sessions. Moreover, complex unfolding analyses are needed to obtain the neutron spectra. This work is an overview of the BSS for area monitoring in particle accelerators.  相似文献   

17.
Experiments were performed in Cave C of GSI (Gesellschaft für Schwerionenforschung) using the LAND (Large Area Neutron Detector) in combination with the deflection magnet ALADIN (A LArge DIpol magNet) in front of the LAND where charged particles and neutrons can be separated. This arrangement is used to create high-energetic neutron fields by irradiation of a thick lead target (5 cm) with deuteron beams with the energies of 500 or 800 MeV per nucleon. In break-up reactions the neutron is separated from the proton which is deflected in the magnetic field of the ALADIN. The produced neutron radiation, which has a pronounced peak at the nucleon energy, is used to measure the fluence response of the GSI neutron ball. A thermoluminescence (TL) based spherical neutron dosemeter was developed for the area monitoring for the quantity H(10) at high-energy accelerators. In the same experiment, the spectral neutron fluence Phi(E) is measured with the LAND in the energy range from 100 MeV to 1 GeV. The measured fluence responses are compared with results of FLUKA calculations and the corresponding fluence-to-dose conversion coefficients. The measured dosemeter responses are too high in comparison to the calculated ones (up to approximately 50%), the dosemeter reading gives dose values which are too high by a factor of 1.1-2.2 related to the corresponding fluence-to-dose conversion factors.  相似文献   

18.
High-energy linear accelerators (linacs) have several advantages, including low skin doses and high dose rates at deep-seated tumours. But, at energies more than 8 MeV, photonuclear reactions produce neutron contamination around the therapeutic beam, which may induce secondary malignancies. In spite of improvements achieved in medical linac designs, many countries still use conventional (non-intensity-modulated radiotherapy) linacs. Hence, in these conventional machines, fitting the beam over the treatment volume may require using blocks. Therefore, the effect of these devices on neutron production of linacs needs to be studied. The aim of this study was to investigate the effect of field shaping blocks on photoneutron dose in the treatment plane for two high-energy medical linacs. Two medical linacs, a Saturn 43 (25 MeV) and an Elekta SL 75/25 (18 MeV), were studied. Polycarbonate (PC) films were used to measure the fluence of photoneutrons produced by these linacs. After electrochemical etching of the PC films, the neutron dose equivalent was calculated at the isocentre and 50 cm away from the isocentre. It was noted that by increasing the distance from the centre of the X-ray beam towards the periphery, the photoneutron dose equivalent decreases rapidly for both the open and blocked fields. Increasing the energy of the photons causes an increase in the amount of photoneutron dose equivalent. At 25 MeV photon energy, the lead blocks cause a meaningful increase in the dose equivalent of photoneutrons. In this research, a 30% increase was seen in neutron dose contribution to central axis dose at the isocentre of a 25 MeV irregular field shaped by lead blocks. It is concluded that lead blocks must be considered as a source of photoneutron production when treating irregular fields with high-energy photons.  相似文献   

19.
During X-ray therapeutic irradiation with energies above the threshold of (X,n) reactions in the structural materials of medical accelerators, a photoneutron fluence is generated. In Brazil, no measurements of neutron doses in radiotherapy rooms are being done yet, when licensing these equipment. Consequently, it is very important to obtain accurate analytical formulae and/or simulation of these dose rates, in order to estimate the increase in dose received by the patient and staff, as well as to correctly project the additional shielding for the treatment room. In this work, we present MCNP simulation of dosimetric quantities at the isocentre of some models of high-energy linear accelerators, and compare it with the values given by the manufacturers, finding good agreement between both.  相似文献   

20.
张辉  张彦立  夏渲 《计量学报》2018,39(1):109-114
中子周围剂量当量(率)仪作为中子辐射水平监测的主要设备须采用适当的方法进行准确校准。亚太计量规划组织于2012年组织了该类仪器的校准比对(APMP.RI(III)-S1),比对协议规定采用放射性核素中子源的中子参考辐射场校准主导实验室提供的比对仪器,并推荐采用影锥法和距离变化法对校准结果进行散射中子修正,参比实验室将比对仪器的校准因子及其不确定度作为比对结果上报。中国计量科学研究院参加了本次比对,比对结果表明参比实验室的校准结果在不确定度范围内一致。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号