变压器的现场局部放电试验 总被引:1,自引:1,他引:1
变压器在现场进行局部放电试验前应根据被试变压器的结线组别、容量、电压、变比来科学地选用试验结线,合理地估算出有功和无功功率,尤其是无功功率,否则将会给现场试验带来很大不便。本文叙述了计算方法、现场的几种试验接线和局部放电的测量方法。 相似文献
5.
电力变压器局部放电试验时容性无功的分析与估算 总被引:1,自引:0,他引:1
高压大容量变压器在现场进行局部放电(简称局放)试验以及超高压、超大容量变压器在制造厂内进行局放试验时,均需用电抗器来补偿被试变压器的容性无功功率,以避免发电机组出现自励磁。为了合理地选择电抗器,试验前需准确地估算被试变压器的容性无功。对变压器容性无功进行了分析与估算,通过2个实例验证了容性无功功率估算公式的准确性,并具有较高的估算精度。 相似文献
6.
大型变压器现场局部放电试验容性功率的计算 总被引:3,自引:1,他引:2
由于受试验装置容量的限制,目前大型变压器现场局部放电试验需要用电抗器来补偿变压器的容性功率。本文着重探讨了一种较准确估算被试变压器容性功率的方法,并已在实践中加以验证。 相似文献
7.
110 kV变压器局部放电试验分析 总被引:1,自引:0,他引:1
介绍110 kV变压器局部放电试验电源类型及容量的选择,分析现场试验接线方式、干扰抑制措施等,结合实例说明开展110 kV变压器局部放电试验的必要性. 相似文献
8.
针对500kV变压器现场局部放电试验受到各种因素的影响,依照现场经验及相关文献逐条分析了涉及500kV变压器局部放电试验的几个关键问题,还探讨了分接开关档位设置问题、高压端绕组变形检测问题、交直流去磁问题及容量补偿问题,并给出了具体的解决方法。 相似文献
9.
10.
11.
Gulski E. Burger H.P. Vaillancourt G.H. Brooks R. 《Dielectrics and Electrical Insulation, IEEE Transactions on》2000,7(1):95-101
The partial discharge (PD) measurements on power transformers are studied with a view toward discrimination and classification of different discharge sources. For this purpose digital analysis is applied to power transformers and reactors going through acceptance testing. Furthermore, based on these measurements, PD databases have been developed to support the discharge evaluation during induced voltage tests of transformers. Using this technique, a clear distinction is possible between transformers showing different discharge behavior 相似文献
12.
13.
14.
介绍了一例500kV大型变压器缺陷的分析、处理过程,它综合了常规电气试验、油中溶解气体色谱分析、局部放电试验、局部放电定位等多种检测手段。认为油色谱分析对于发现变压器的潜伏性缺陷十分有效,局部放电试验是检验大型变压器绝缘性故障的有效手段,而大型变压器的超声波局部放电定位还属初步尝试,需积累更多的经验。 相似文献
15.
Converter transformers are one of the key components in high voltage DC power networks. The insulation of these transformers is stressed by both AC and DC voltages. Therefore, AC and DC voltage tests are routinely applied during factory tests to verify the performance of the insulation structure. Partial discharges in an insulation system are incipient discharges that can damage materials and may eventually lead to complete failure of the insulation system during operation. Recently it has been shown that monitoring such discharges formed under AC stress is feasible using Ultra High Frequency (UHF) measurement technique and that there is a reasonable correlation between the partial discharge magnitude and the amplitude of the UHF signal generated by partial discharges. However, the partial discharge activity under DC voltages is not fully understood. This paper describes a study using the UHF technique to improve our understanding of particle-induced partial discharge activity under DC voltages in mineral oil insulation. UHF signals generated due to conducting particle contamination in transformer oil under AC and DC voltages are compared and analyzed. A method for distinguishing particle discharges in regions of high or low electric field stress is proposed based on frequency-domain analysis of the measured UHF signal. 相似文献
16.
17.
18.
19.
局放试验作为变压器现场交接试验的一种,是考核变压器最严厉的方法之一,可以有效检测其内部是否存在缺陷故障。特高压变压器的现场局部放电试验中,在计算分析被试变压器的容性无功及感性补偿的基础上,首次提出了基于大容量可调电抗器的无级调感技术以及感性无功实时监测方法,可调电抗器可以平滑的调节电抗值从而改变感性补偿,感性补偿实时监测方法可实时反映试验中的补偿状态,保障试验高效安全进行。 相似文献
20.
局部放电是电力变压器绝缘劣化的主要原因,研究局部放电定位对提高电网的安全运行至关重要,研究局部放电的定位首先要明确局部放电的定向。文章提出了一种基于最小方差信号无畸变响应(MVDR)聚焦波束形成的方法,对变压器单个局部放电源定向进行仿真研究,将MVDR方位估计与聚焦波束形成相结合,在定向方面与常规的聚焦波束形成(CBF)相比较,分辨率升高,旁瓣级有明显降低,"混叠"效应的影响更小,该方法还具有抗电磁干扰能力强、系统稳定性好、能够进行现场实时监测等优点。最后通过对该方法的空间谱仿真证明其正确性和有效性。 相似文献