首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An atmospheric pressure plasma jet generated in Ar and O2/Ar mixtures has been investigated by specially designed equipment with double power electrodes at 20~32 kHz, and their effects on the cleaning of surfaces have been studied. Properties of the jet discharge are studied by electrical diagnostics, including the waveform of discharge voltage, discharge current and the Q-V Lissajous figures. The optical emission spectroscopy is used to measure the plasma parameters, such as the excitation temperature and the gas temperature. It is found that the consumed power and the excitation temperature increase with increase of the discharge frequency. On the other hand, at the same discharge frequency, these parameters in O2/Ar mixture plasma are found to be much larger. The effect on surface cleaning is studied from the changes in the contact angle. For Ar plasma jet, the contact angle decreases with increase of the discharge frequency. For O2/Ar mixture plasma jet, the contact angle decreases with increase of discharge frequency up to 26 kHz, however, further increase of discharge frequency does not show further decrease in the contact angle. At the same discharge frequency, the contact angle after O2/Ar mixture plasma cleaning is found to be much lower compared to the case of pure Ar. From the results of quadrupole mass-spectrum analysis, we can identify more fragment molecules of CO and H2O in the emitted gases after O2/Ar plasma jet treatment compared with Ar plasma jet treatment, which are produced by the decomposition of surface organic contaminants during the cleaning process.  相似文献   

2.
The pulsed corona discharge (CD) generated in contact with water and directly in water, and high-power air plasma jet (APJ) were studied for production of plasma activated water (PAW). The changes of physical (pH, redox potential, conductivity, temperature) and chemical (peroxides, nitrites, nitrates concentrations) properties of treated water were investigated. The comparison of CD generated in gas/water interface and underwater configuration in the same system showed that the interaction of reactive oxygen and nitrogen species formed in ambient air in gas/water system induces different chemical processes, leading to lower pH, higher oxidation-reduction potential (ORP) and higher conductivity of PAW than in underwater discharge. High yield of peroxide was observed in both configurations. The PAW prepared by APJ exhibits high concentration of nitrites and nitrates according to supplied energy, and related significant decrease of pH and increase of ORP and conductivity after treatment. The antimicrobial effect of PAW prepared by CD and plasma jet on lentils sprouts was studied in different treatment and washing times. The APJ appears to have great efficacy on water activation resulted in strong decontamination effect. The PAW treated by APJ for 10 min led to bacterial reduction from initial 8.3 to 5.9 and 4.0 log10 CFU g−1 after 10 and 30 min of washing, respectively.  相似文献   

3.
《等离子体科学和技术》2015,17(12):1053-1060
A discharge plasma reactor with a point-to-plane structure was widely studied experimentally in wastewater treatment.In order to improve the utilization efficiency of active species and the energy efficiency of this kind of discharge plasma reactor during wastewater treatment,the electrode configuration of the point-to-plane corona discharge reactor was studied by evaluating the effects of discharge spacing and adjacent point distance on discharge power and discharge energy density,and then dye-containing wastewater decoloration experiments were conducted on the basis of the optimum electrode configuration.The experimental results of the discharge characteristics showed that high discharge power and discharge energy density were achieved when the ratio of discharge spacing to adjacent point distance(d/s) was 0.5.Reactive Brilliant Blue(RBB) wastewater treatment experiments presented that the highest RBB decoloration efficiency was observed at d/s of 0.5,which was consistent with the result obtained in the discharge characteristics experiments.In addition,the biodegradability of RBB wastewater was enhanced greatly after discharge plasma treatment under the optimum electrode configuration.RBB degradation processes were analyzed by GC-MS and IC,and the possible mechanism for RBB decoloration was also discussed.  相似文献   

4.
In the paper, a hybrid gas–liquid dielectric barrier discharge (DBD) plasma system was set up to treat a methylene blue (MB) solution. The effects of the change of the carrier gas, the gas bubbling rate and different kinds of scavenger addition, including sodium carbonate (Na2CO3), para benzoquinone (p-BQ), triethylenediamine and sodium dihydrogen phosphate (NaH2PO4), on the MB decoloration were reviewed to clarify the critical active species for the dye decoloration in the DBD plasma system. The obtained results show that higher decoloration of the MB solution could be achieved when O2 was used as the carrier gas, which could be 100% after 20 min discharge treatment, and the result confirmed the crucial effect of O3 in the MB decoloration. Based on the experiments of the scavenger addition, it could be concluded that O2 and 1O2 were two other important reactive oxygen species (ROS) for the MB decoloration. The results of the higher chemical oxygen demand removal and faster disappearance of the characteristic peak of the MB from the UV–vis analysis under O2 bubbling conditions also proved the critical effect of the ROS formed by O2 on the MB decoloration.  相似文献   

5.
Electric field is an important parameter of plasma,which is related to electron temperature,electron density,excited species density,and so on.In this work,the electric field of an atmospheric pressure plasma jet is diagnosed by the electric field induced second harmonic(E-FISH) method,and the time-resolved electric field under different conditions is investigated.When positive pulse voltage is applied,the electric field has a peak of about 25 kV cm-1 at the rising edge of the voltage...  相似文献   

6.
The multifunctionality and the advantages of thermal plasma for the fast inactivation of viable cells and degradation of organic compounds dissolved in waste water are presented.A complete bacterial inactivation process was observed and studied using a thermal plasma treatment source with very short application times,in particular for Staphylococcus aureus bundle spore survival.The survival curves and analyses of the experimental data of the initial and final densities of S.aureus bacteria show a dramatic inhibitory effect of the plasma discharge on the residual bacteria survival ratio.As the exposure time increased,the inactivation process rate increased for direct exposure more than it did for indirect exposure.The evaluation of direct and indirect exposure was based on the analysis of the ultraviolet spectrum from the absorbance spectra of the organic compound dye called benzene sulfonate(C_(16)H_(11)N_2Na O_4S)and of viable cells called S.aureus.Organic compounds were degraded and viable cells were killed in a short time by thermal plasma.Moreover,analyses of total carbon,total organic carbon,and total inorganic carbon showed a fast decrease in organically bound carbon,however,this was not as fast as the absorbance spectra revealed by the exposure time increasing more for direct exposure than indirect exposure.After 100 s of exposure to the organic compound dye the removal had a maximun of 40%for samples with indirect exposure to the plasma and a maximum of 90%for samples with the direct exposure.For both samples,where some organic contaminants still remained in treated water,four electrolytes(KCl,Na Cl,Na_2SO_4,and CH_3COONa)were added to be effective for complete sterilization,reaching a purity of 100%.A proposal is made for an optimized thermal plasma water purification system(TPWPS)to improve fast inactivation of microbes and the degradation of organic compounds dissolved in water(especially for direct exposure rather than indirect exposure)using a hybrid plasma torch with an electrical power of 125 kW(500 V–250 A)producing a high-temperature(10 000 K–19 000 K)plasma jet with a maximum gas consumption of 28 mg s~(-1).  相似文献   

7.
A direct-current air plasma jet operated underwater presents three stable modes including an intermittently-pulsed discharge, a periodically-pulsed discharge and a continuous discharge with increasing the power voltage. The three discharge modes have different appearances for the plasma plumes. Moreover, gap voltage-current characteristics indicate that the continuous discharge is in a normal glow regime. Spectral lines from reactive species(OH, N_2, N_2~+, H_α,and O) have been revealed in the emission spectrum of the plasma jet operated underwater.Spectral intensities emitted from OH radical and oxygen atom increase with increasing the power voltage or the gas flow rate, indicating that reactive species are abundant. These reactive species cause the degradation of the methylene blue dye in solution. Effects of the experimental parameters such as the power voltage, the gas flow rate and the treatment time are investigated on the degradation efficiency. Results indicate that the degradation efficiency increases with increasing the power voltage, the gas flow rate or the treatment time. Compared with degradation in the intermittently-pulsed mode or the periodically-pulsed one, it is more efficient in the continuous mode, reaching 98% after 21 min treatment.  相似文献   

8.
A dielectric barrier discharge (DBD) reactor with a rod-plate electrode configuration was used for the oxidative decomposition of Congo red dye in an aqueous solution.Plasma was generated in the gas space above the water interface under atmospheric pressure.Discharge characteristics were analyzed by voltage-current waveforms.Effects of applied voltage,initial conductivity,and initial concentration were also analyzed.Congo red discoloration increased with increased applied voltage and decreased conductivity.The initial conductivity significantly influenced the Congo red discoloration.Under the same conditions,the highest discoloration rate was obtained at 25 mg/L.The presence of ferrous ions in the solutions had a substantial positive effect on Fenton dye degradation and flocculation.At an applied voltage of 20 kV,about 100%of dye was degraded after 4 min of Fe2+/DBD treatment.Results showed that adding a certain dosage of hydrogen peroxide to the wastewater could enhance the discoloration rate.Possible pathways of Congo red discoloration by DBD plasma were proposed based on GC/MS,FTIR,and UV-vis spectroscopy analyses.  相似文献   

9.
Epoxy resin (EP) tends to accumulate a large amount of charge on its surface when exposed to a high-voltage DC electric field,which leads to a reduction in its insulative performance and an increase in potential safety risks in power systems.To suppress charge accumulation,improve the flashover voltage of the EP,and reduce the risk of gas insulated switchgear (GIS)/gas insulated transmission line (GIL) failure,we used two plasma-etching methods,i.e.,atmospheric-pressure dielectric barrier discharge (DBD) and the atmospheric-pressure plasma jet(APPJ),to modify the surface of the EP.The surface morphology and electrical properties of the modified materials were explored as a function of time.The results show that after DBD treatment,the roughness of the sample increases by 103.9 nm,the conductivity increases by3.9?×?10~(–18)S,and the flashover voltage increases by 14.4%;after APPJ treatment,the roughness of the sample increases by 223.5 nm,the conductivity increases by 3.4?×?10~(–17)S,and the flashover voltage increases by 18%.This shows that both plasma-etching methods can improve the insulation properties of materials by improving the surface-charge characteristics.The two methods are compared with each other:the APPJ treatment method is better at improving the surface roughness and electrical properties of materials,and this flexible treatment method has greater potential in industrial applications.  相似文献   

10.
In this study,we investigated the effects of the quartz tube diameter,air flow rate,and applied voltage on the characteristics of an air plasma jet to obtain the optimized discharge characteristics.The physicochemical properties and concentration of reactive oxygen and nitrogen species(RONS)in plasma-activated medium(PAM)were characterized to explore their chemical activity.Furthermore,we investigated the inactivation effect of air plasma jet on tumour cells and their corresponding inactivation mechanism.The results show that the tube diameter plays an important role in sustaining the voltage of the air plasma jet,and the gas flow rate affects the jet length and discharge intensity.Additionally,the air plasma jet discharge displays two modes,namely,ozone and nitrogen oxide modes at high and low gas flow rates,respectively.Increasing the voltage increases the concentration of reactive species and the length of discharge.By evaluating the viability of A549 cells under different parameters,the optimal treatment conditions were determined to be a quartz tube diameter of 4 mm,gas flow rate of 0.5 SLM,and voltage of 18 kV.Furthermore,an air plasma jet under the optimized conditions effectively enhanced the chemical activity in PAM and produced more aqueous RONS.The air plasma jet induced significant cytotoxicity in A549 cancer cells after plasma treatment.H2O2 and NO2 are regarded as key factors in promoting cell inactivation.The present study demonstrates the potential use of tumour cell therapy by atmospheric air PAM,which aids a better understanding of plasma liquid chemistry.  相似文献   

11.
In the last two decades a growing interest has been shown in the investigation of atmospheric pressure plasma jets (APPJs) that operate in contact with liquid samples. In order to form a complete picture about such experimental systems, it is necessary to perform detailed diagnostics of plasma jets, as one step that will enable the adjustment of system properties for applications in different areas. In this work, we conducted a detailed electrical characterisation of a plasma system configuration used for water treatment. A helium plasma jet, with a pin electrode powered by a continuous sine wave at a frequency of 330 kHz, formed a streamer that was in contact with a distilled water sample. An electrical circuit allowed the monitoring of electrical signals supplied to the jet and also to the plasma itself. An electrical characterisation together with power consumption measurements was obtained by using two different methods. The first method was based on the direct measurements of voltage and current signals, while in the second method we used 'Lissajous figures'. We compared these two methods when used for discharge power estimation and addressed their advantages and limitations. The results showed that both of these methods could be used to successfully determine power consumed by a discharge in contact with water, but only when taking into account power dissipation without plasma.  相似文献   

12.
Through using a direct-current driven plasma jet operated underwater, degradation of methylene blue(MB) is investigated with air and oxygen used as working gases. With a low power voltage,a plasma plume extends from the needle electrode, which is purple in air. It turns pink after it bridges the two electrodes. During the process, oxygen plasma remains white. Discharge operates in a pulsed mode or a continuous one, which depends on the magnitude of power voltage. For the pulsed mode, oxygen discharge has a shorter plume and a higher pulse frequency than air discharge under the same power voltage. For the same current of the continuous mode, both power and gap voltages of oxygen discharge are higher than those of air discharge. Moreover, MB degradation efficiency increases with increasing power voltage or initial concentration of MB solution. Compared with air discharge, oxygen discharge has a higher degradation efficiency with the same power voltage and treatment time. The pulsed oxygen discharge with power voltage of about 6.5 k V has the highest efficiency in degrading MB dye, reaching approximately 85.8% after 10 min treatment. As a comparison, after 10 min treatment in air discharge, the highest degradation efficiency is 63.7%, which appears in the continuous mode at a power voltage of 10.6 kV. Besides, optical spectra from the discharges are also compared for the two types of working gases.  相似文献   

13.
Recently, a plasma catalyst was employed to efficiently degrade antibiotic residues in the environment. In this study, the plasma generated in a packed bed dielectric barrier reactor combined with TiO2 catalyst is used to degrade the antibiotic tiamulin (TIA) loaded on the surface of simulated soil particles. The effects of applied voltage, composition of the working gas, gas flow rate and presence or absence of catalyst on the degradation effect were studied. It was found that plasma and catalyst can produce a synergistic effect under optimal conditions (applied voltage 25 kV, oxygen ratio 1%, gas flow rate 0.6 l min−1, treatment time 5 min). The degradation efficiency of the plasma combined with catalyst can reach 78.6%, which is 18.4% higher than that of plasma without catalyst. When the applied voltage is 30 kV, the gas flow rate is 1 l min−1, the oxygen ratio is 1% and the plasma combined with TiO2 catalyst treats the sample for 5 min the degradation efficiency of TIA reached 97%. It can be concluded that a higher applied voltage and longer processing times not only lead to more degradation but also result in a lower energy efficiency. Decreasing the oxygen ratio and gas flow rate could improve the degradation efficiency. The relative distribution and identity of the major TIA degradation product generated was determined by high-performance liquid chromatography–mass spectrometry analysis. The mechanism of TIA removal by plasma and TiO2 catalyst was analyzed, and the possible degradation path is discussed.  相似文献   

14.
Two plasma reactors have been developed and used to degrade dye wastewater agents.The configuration of one plasma reactor is a comb-like extendable unit module consisting of 5 electrodes covered with a quartz tube and the other one is an array reactor which is extended from the unit module.The decomposition of wastewater by ns pulse dielectric barrier discharge(DBD) plasma have been carried out by atomizing the dyeing solutions into the reactors.During experiments,the indigo carmine has been treated as the waste agent.The measurements of UV-VIS absorption spectroscopy and the chemical oxygen demand(COD) are carried out to demonstrate the decomposition efect on the wastewater.It shows that the decoloration rate of 99% and the COD degradation rate of 65% are achieved with 15 min treatment in the unit reactor.The efect of electrical parameters on degradation has been studied in detail.Results from the array reactor indicate that it has a better degradation efect than the unit one.It can not only totally remove the chromogenic bond of the indigo carmine solution,but also efectively degrade unsaturated bonds.The decoloration rate reaches 99% after 10 min treatment,the decomposition rate of the unsaturated bond reaches 83% after 60 min treatment,and the COD degradation rate is nearly 74%.  相似文献   

15.
In this paper, the air plasma jet produced by micro-hollow cathode discharge(MHCD) is investigated. The discharge is powered by a positive nanosecond pulse high voltage supply. The waveforms of the discharge, the images of the jet, the evolution of the plasma bullet and the reactive species are obtained to analyze the characteristics of the MHCD plasma jet. It is found that the length of the plasma jet is almost proportional to the air flow rate of 2–6 slm. Two plasma bullets appear one after another during a single period of the voltage waveform, and both of the two plasma bullets are formed during the positive pulse voltage off. The propagation velocity of the two plasma bullets is on the order of several hundred m/s, which is approximate to that of the air flow. These results indicate that the gas flow has an important influence on the formation of this MHCD plasma jet.  相似文献   

16.
An atmospheric-pressure plasma jet array specially designed for HTV silicone rubber treatment is reported in this paper. Stable plasma containing highly energetic active particles was uniformly generated in the plasma jet array. The discharge pattern was affected by the applied voltage. The divergence phenomenon was observed at low gas flow rate and abated when the flow rate increased.Temperature of the plasma plume is close to room temperature which makes it feasible for temperature-sensitive material treatment. Hydrophobicity of contaminated HTV silicone rubber was significantly improved after quick exposure of the plasma jet array, and the effective treatment area reached 120 mm?×?50 mm(length?×?width). Reactive particles in the plasma accelerate accumulation of the hydrophobic molecules, namely low molecular weight silicone chains, on the contaminated surface, which result in a hydrophobicity improvement of the HTV silicone rubber.  相似文献   

17.
In this work, a typical pin-to-pin plasma synthetic jet in static air is excited by a pulsed DC power supply. The influences of the pulse rising time, the amplitude and the repetition frequency of the pulse voltage on the jet flow have been investigated. First, using a high-speed Schlieren imaging technique, the induced shock waves and the fast jet flow generated by the plasma synthetic jet are characterized. With a deposited energy of 44 mJ per pulse, the velocity of the shock wave and the maximum velocity of the jet flow reach 320 m s−1 and 100 m s−1, respectively. Second, when the applied voltage increases from 12.8 kV to 16 kV, the maximum jet velocity increases from 66 m s−1 to 93 m s−1. On the other hand, as the pulse rising time varies from 50 ns to 500 ns, or the pulse repetition frequency increases from 5 Hz to 40 Hz, the jet velocity induced by the plasma synthetic jet is weakly dependent. In addition, a comparative study of the plasma synthetic jets using three commercial pulsed power supplies (XJ-15, NPG- 18, and PG-30) is implemented. It reveals that the maximum jet velocity of 120 m s−1 is obtained in the case of PG-30, with the longest pulse rising time and the lowest breakdown voltage, while the maximum velocity of 33 m s−1 is detected in the case of NPG-18, even though it has the shortest pulse rising time and the highest breakdown voltage.  相似文献   

18.
The plasma synthetic jet is a novel active flow control method because of advantages such as fast response,high frequency and non-moving parts,and it has received more attention recently,especially regarding its application to high-speed flow control.In this paper,the experimental characterization of the plasma synthetic jet actuator is investigated.The actuator consists of a copper anode,a tungsten cathode and a ceramic shell,and with these three parts a cavity can be formed inside the actuator.A pulsed-DC power supply was adopted to generate the arc plasma between the electrodes,through which the gas inside was heated and expanded from the orifice.Discharge parameters such as voltage and current were recorded,respectively,by voltage and current probes.The schlieren system was used for flow visualization,and jet velocities with different discharge parameters were measured.The schlieren images showed that the strength of plasma jets in a series of pulses varies from each other.Through velocity measurement,it is found that at a fixed frequency,the jet velocity hardly increases when the discharge voltage ranges from 16 kV to 20 kV.However,with the discharge voltage fixed,the jet velocity suddenly decreases when the pulse frequency rises above 500 Hz,whereas at other testing frequencies no such decrease was observed.The maximum jet velocity measured in the experiment was up to110 m/s,which is believed to be effective for high-speed flow control.  相似文献   

19.
An atmospheric pressure radio-frequency plasma jet that can eject cold plasma has been developed. In this paper, the configuration of this type of plasma jet is illustrated and its discharge characteristics curves are studied with a current and a voltage probe. A thermal couple is used to measure the temperature distribution along the axis of the jet stream. The temperature distribution curve is generated for the He/O2 jet stream at the discharge power of 150 W. This jet can etch the photo-resistant material at an average rate of 100 nm/min on the surface of silicon wafers at a right angle.  相似文献   

20.
This work treats the Al2O3-ER sample surface using dielectric barrier discharge fluorination(DBD-F),DBD silicon deposition(DBD-Si),atmospheric-pressure plasma jet fluorination(APPJ-F)and APPJ silicon deposition(APPJ-Si).By comparing the surface morphology,chemical components and electrical parameters,the diverse mechanisms of different plasma modification methods used to improve flashover performance are revealed.The results show that the flashover voltage of the DBD-F samples is the largest(increased by 21.2%at most),while the APPJ-F method has the worst promotion effect.The flashover voltage of the APPJ-Si samples decreases sharply when treatment time exceeds 180 s,but the promotion effect outperforms the DBD-Si method during a short modified time.For the mechanism explanation,firstly,plasma fluorination improves the surface roughness and introduces shallow traps by etching the surface and grafting fluorine-containing groups,while plasma silicon deposition reduces the surface roughness and introduces a large number of shallow traps by coating SiOx film.Furthermore,the reaction of the DBD method is more violent,while the homogeneity of the APPJ modification is better.These characteristics influence the effects of fluorination and silicon deposition.Finally,increasing the surface roughness and introducing shallow traps accelerates surface charge dissipation and inhibits flashover,but too many shallow traps greatly increase the dissipated rate and facilitate surface flashover instead.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号