首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper evaluates the failure and wear properties of the alumina ceramic posterior cruciate condylar total knee prosthesis, and reports the preliminary clinical results of this prosthesis. Thirteen sets of the alumina ceramic prostheses were used for destruction and wear tests. The average ultimate load in the static destruction tests showed 2.63 x 10(4) Newtons in the femoral component, and 1.28 x 10(4) Newtons in the tibial component. The average ultimate energy in the impact destruction tests showed 22.1 Joules in the femoral components, and 20.3 Joules in the tibial components. The wear test demonstrated that the average depth of wear was 0.04 mm in the alumina ceramic prostheses, and 0.20 mm in the Vitallium prostheses. Observation of the UHMWPE wear surface with a scanning electron microscope indicated many deep scratches and a scooped concave lesion in the Vitallium prostheses; there were few deep scratches in the alumina ceramic prostheses. Thirty patients underwent 32 total knee arthroplasties using the alumina ceramic posterior cruciate condylar prosthesis between 1988 and 1990. The results were evaluated as excellent for 59%, good for 28%, fair for 10%, and poor for 3%. Critical roentgenographic review demonstrated no cases of loosening or sinking after arthroplasties using the alumina ceramic prosthesis. Radiolucent lines were observed only in 4 knees (12%) cases. All were observed around the tibial components, but were less than 1 mm in thickness. The frequency of the radiolucent lines is less than that observed in the Vitallium prosthesis at the same followup period. The alumina ceramic posterior cruciate condylar prosthesis may have sufficient durability and excellent wear properties for low friction total knee arthroplasty.  相似文献   

2.
A prospective study of a hybrid total knee arthroplasty (TKA) with an uncemented femoral component and cemented tibial and patellar components was performed to combine the advantage of a press-fit femur while avoiding the problems in uncemented tibial and patellar implants. A total of 329 posterior cruciate-preserving TKA were studied at an average of 4.7 years after surgery: 84% of the knees had at most mild or occasional pain, 68% had good or excellent knee scores, and 62% could walk more than 1000 m. The function scores were 40% good or excellent in this collective, with an average age of 69.4 years at surgery. The component position and alignment were biomechanically correct. Radiolucent lines were observed regularly at the edges of the tibial and femoral components. There were no revisions for aseptic loosening. Hybrid TKA provides good results comparable to cemented TKA.  相似文献   

3.
Analysis of an on-going prospective study of seventy-seven hinged total knee arthroplasties in sixty-seven patients revealed that most patients had improvement in function, although major complications occurred in eighteen knees (23.4 per cent. These complications included sepsis, loosening, patellar tendon rupture, peroneal palsy, and patellar subluxation. Eight of nine knees with deep sepsis required removal of the prosthesis, and three of sixteen knees with patellar pain required realignment of the quadriceps. When prosthetic failure occurred, salvage of a functional extremity was difficult. Hinged total arthroplasty is not without its problems, and a cautious approach to its use is indicated. Whenever possible, a moderately constrained replacement arthroplasty should be considered.  相似文献   

4.
Polycentric total knee arthroplasty in 56 patients provided significant relief of pain in 90.7% and a stable knee in 92.7%. Postoperative increase in range of motion averaged 13.7 degrees for all patients (18.5 degrees in rheumatoid arthritis and 8.7 degrees in degenerative arthritis). This increase in excursion is attributed to the design of the prosthesis, a vigorous postoperative rehabilitation program, and careful surgical technic. A failure rate of 12.7% was due to infection, mechanical instability and unexplained pain. Contraindications to surgery and technical recommendations are noted.  相似文献   

5.
The Rotaglide knee (Cozim Medical, UK) is a three-part knee containing a mobile polyethylene meniscal platform, imparting reduced loosening forces to the tibia. The femoral component design provides a high degree of congruency throughout the range of motion from 0 degree to 110 degrees, and both femoral and tibial components ensure minimal bone removal. The system is versatile, including a large number of component options, and it may be used in both primary and revision arthroplasties. The first results in 170 cemented knees (161 patients) with 2- to 5-year follow-up periods (average, 3.1 years) were very encouraging (excellent or good in 95% of knees, based on the British Orthopaedic Association knee assessment system). Poor results were seen only in revision cases. There have been no mechanical implant failures and no platform bearing dislocations, and the platforms continue to move as documented by postoperative roentgenograms, which show the metal markers of the platforms moving anteriorly in flexion and posteriorly in extension.  相似文献   

6.
Four knee-scoring systems were used to evaluate 200 adult subjects who had no history of injury, abnormality, or treatment of the knees, hips, lower extremities, or spine. All subjects were in the age-range (fifty to 100 years; average, 65.5 years) typical of candidates for total knee replacement. In addition to a physical examination, complete demographic data were collected for each subject. The knee scores were normalized by dividing the observed score by the maximum possible score. The average normalized total knee score was 91 per cent (range, 22 to 100 per cent) according to the knee score of The Hospital for Special Surgery, 95 per cent (range, 10 to 100 per cent) according to the system of Hungerford and Kenna, 89 per cent (range, -7.75 to 100 per cent) according to a modification of the scoring system of The Knee Society, and 95 per cent (range, 26.5 to 100 per cent) according to the system of Hofmann et al. Demographic variables that had a significant negative correlation with the knee scores included advanced age (particularly of eighty-five years or more), a family income below the poverty level, and two major medical conditions or more. Observed differences in knee scores between different study groups that have not been matched for various clinically relevant factors are at least as likely to represent differences in the patient populations as they are to represent differences in the operative technique or the design of the implant.  相似文献   

7.
OBJECTIVE: The objective of this study was to examine the effect of family and neighborhood income on health care use of young children born prematurely and of low birth weight (N = 619). DESIGN: A birth cohort was enrolled in a clinical randomized trial of early childhood educational and family services. SETTINGS/PARTICIPANTS: Infant Health and Development Program provided a sample of low birth weight premature infants stratified by clinical site, birth weight, and treatment group. Maternal reports of health care use, family income, and heath insurance were obtained at 12, 24, and 36 months of corrected age. Neighborhood income was based on census tract residence at birth. MAIN OUTCOME MEASURES: Maternal reports of hospitalizations, doctor visits, and emergency department visits were used; data were averaged over the child's first 3 years of life. RESULTS: Children from poorer families were more likely to be hospitalized and to have more emergency department visits than were children from more affluent families. Residence in poor and middle-income neighborhoods was associated with more emergency department visits than residence in affluent neighborhoods. Families in middle-income neighborhoods reported more doctor visits than families in poor or affluent neighborhoods. CONCLUSION: Neighborhood residence influences health care use by poor and nonpoor families and by insured and uninsured families. The use of the emergency department for low birth weight premature children in middle-income and poor neighborhoods is discussed.  相似文献   

8.
The survivorship method of analysis was used to compare the failure rate and overall success of 2629 cemented primary total knee arthroplasties during a 22-year period by the senior surgeon. There were 215 Total Condylar prostheses with a polyethylene tibia, 265 of the Posterior Stabilized type with an all polyethylene tibia, 2036 Posterior Stabilized with a metal backed tibial component, 49 Posterior Stabilized with modular augmented components, and 64 with the Constrained Condylar system. Failure was considered revision or planned revision. The Total Condylar series had an average annual failure rate of 0.46% and a 21-year success rate of 90.77%. The Posterior Stabilized prosthesis with an all polyethylene tibia had an average annual rate of failure of 0.38% and a 16-year success rate of 94.10%, and this prosthesis with a metal backed tibial component had an annual failure rate of 0.14% and a 14-year success rate of 98.10%. The Posterior Stabilized series with modular components had an average annual rate of failure of 0.59% and a 10-year success rate of 93.63%. The Constrained Condylar knee series had an average annual failure rate of 0.26% and a 7-year success rate of 98.12%. This review represents a retrospective analysis of consecutive series of cemented, total knee arthroplasties, whose annual failure and success rates were done during differing time spans. The overall success rate was not influenced by gender, age, diagnosis, or percentage of ideal body weight. Failure was considered revision or planned revision. The best and worse case scenarios were calculated for each series. Long term results of cemented, total knee arthroplasty with a relatively conforming articular surface has been shown to be a reliable procedure with excellent survivorship.  相似文献   

9.
Early results of 76 geometric total knee replacements were reviewed with assistance from computer analysis. A 92% patient follow-up for one to three years showed an overall satisfactory result with substantial improvement, especially in relief of severe pain. However, several problems are noted, including fractures beneath the tibial plateau and loosening. The long-term results are still unknown. The indications for total knee replacements should remain conservative until long-term results and experience have been achieved.  相似文献   

10.
Using a retrospective cohort study design, the authors examined complications, readmissions, morbidity and mortality, and function scores in two groups of patients attended by the same surgeon for the year before and the year after the implementation of an outcomes management program with clinical pathways for patients undergoing total knee arthroplasty at an academic health center. The effectiveness of the pathway constantly was adjusted using variance analysis and continuous quality improvement techniques. This program reduced the length of stay by 57% from a premanagement value of 10.9 +/- 5.4 days in 1994 (Group 1) to 4.7 +/- 1.4 days in 1996 (Group 2). Hospital costs (based on an inflation adjusted cost to charge ratio) for all total knees were reduced 11% from $13,328 +/- $3905 in 1994 to $11,862 +/- $4763 in 1996. Preoperative and postoperative knee scores were 41.1 +/- 16.3 and 84.2 +/- 16.0 for Group 1 and 42.5 +/- 13.0 and 87.0 +/- 10.4 for Group 2, respectively. There was no statistically significant difference between the preoperative or the postoperative knee scores of Groups 1 and 2. The application of clinical pathways, variance analysis, and continuous quality improvement toward the treatment of patients who had total knee arthroplasty at an academic health center resulted in significant savings in length of stay without adversely affecting overall outcome.  相似文献   

11.
A retrospective matched-pair comparative analysis was done between 30 total knee arthroplasties following failed high tibial osteotomies and 30 total knee arthroplasties following failed unicompartmental knee arthroplasties. The groups were matched according to age, gender, type of prosthesis, primary disease, and length of followup. A minimum followup of 2 years was required for inclusion in the study, and the average followup was 3.8 years (range, 2-9 years). The Knee Society Knee Score for the high tibial osteotomy group was significantly higher than that for the unicompartmental arthroplasty group. More osseous reconstructions were required in the unicompartmental revisions. Difficulty with exposure was not significantly greater in the osteotomy group. Rates of component loosening were not significantly different between the groups. A failed unicompartmental knee arthroplasty and a failed high tibial osteotomy can be revised successfully to a total knee arthroplasty. The results confirm that revisions after unicondylar arthroplasty and high tibial osteotomy are technically demanding. In this series, the results of total knee arthroplasty following unicompartmental knee arthroplasty approached but did not equal those obtained after high tibial osteotomy.  相似文献   

12.
Femoral and sciatic nerve blocks have been used occasionally for unilateral total knee arthroplasty (TKA). In order to evaluate the effectiveness of this technique, combined femoral 3-in-1 and sciatic nerve blocks were performed in 20 cases of TKA, by the same surgeon. This surgeon also performed unilateral TKA under spinal anesthesia in another 20 cases. The anesthetic effectiveness of the two types of anesthesia was compared in terms of the time needed to complete the surgery, amount of intraoperative blood loss, and time interval until the first dose of analgesic. The results showed that the two types of anesthesia had comparable anesthetic effects. Ten of the 20 patients who had spinal anesthesia complained of postoperative urinary retention, while none of those who had nerve block had this complaint. Neither group experienced postpunctural headache, neurovascular damage, or drug-over-dose toxicity. We conclude that combined femoral 3-in-1 and sciatic nerve block is an effective anesthetic alternative for unilateral TKA.  相似文献   

13.
A review of 356 Kinemax (Howmedica, Inc, Rutherford, NJ) cemented posterior cruciate ligament-retaining condylar total knee arthroplasties employing a symmetrical femoral component articulating with a medially offset symmetrical dome patella component was carried out to examine the results and determine the incidence and nature of the patellofemoral complications. Follow-up was from 3 to 8 years, with a mean of 5.1 years. A review of patellofemoral complications in previously reported homogeneous series of symmetrical and asymmetrical implants is presented. Mean postoperative Knee Society scores improved to 91, function scores to 86, and Hospital of Special Surgery scores to 90 yielding 95% good and excellent results. Mean postoperative range of motion was -1.5 degrees extension to 113 degrees flexion. There were five patellofemoral complications (1.4%), including two symptomatic subluxations, two distal pole avulsion fractures, and one lateral facet fracture. There were two reoperations necessary for patellofemoral problems (0.56%), one to correct subluxation and one for excision of the fractured lateral facet. These rates are lower than those previously reported for asymmetrical implants as well as current and phased-out symmetrical designs of total knee arthroplasty in the intermediate term. This review suggests that cemented total knee arthroplasty with symmetrical patellofemoral resurfacing with an offset patella dome and posterior cruciate ligament retention yields low patellofemoral complications and reoperations. The symmetrical femoral component appears to be a satisfactory compromise of "normal" femoral anatomy, which decreases inventory and cost without adversely affecting patellofemoral function and complications.  相似文献   

14.
Osteolysis has not been mentioned as a complication or cause of failure of cemented total knee arthroplasties in long-term follow-up studies. We are aware of a single case report of osteolysis after cemented total knee arthroplasty. We report the case of an 87-year-old woman with massive osteolysis beneath a cemented tibial component.  相似文献   

15.
Equal resection of the posterior femoral condyles combined with a 90 degree tibial resection results in a trapezoidal flexion space. Two groups of patients were studied; in one group, the flexion space was allowed to remain trapezoidal, whereas in the other group, the anteroposterior femoral resections were externally rotated to allow rectangularization of the flexion space. In the second group, the range of flexion was increased and the incidence of medial tibial pain and zone I radiolucencies decreased. Other than for knees in a hypervalgus position before surgery, the mean amount of rotation required was 3 degrees +/- 0.2 degrees.  相似文献   

16.
17.
From 1981 through 1991, 3,032 primary total knee arthroplasties were performed using the Insall-Burstein Posterior Stabilized Condylar Prosthesis (IB-I, IB-II, and IB-II modified) (Zimmer, Warsaw, IN). Fifteen posterior dislocations occurred: 4 with the IB-I system occurring 2 or more years after surgery, 10 with the IB-II system (8 occurring 6 months after surgery and 2 occurring 2-3 years after surgery), and 1 with the IB-II modified system occurring 9 months after surgery. Statistically significant differences for the rate of dislocation between both the IB-I and IB-II modified arthroplasties versus the IB-II arthroplasties were found (P < .001). In an attempt to identify a cause for these dislocations, the authors retrospectively assessed the 15 dislocated cases with respect to sex, age, weight, height, preoperative and postoperative Hospital for Special Surgery scores, preoperative and postoperative alignment, preoperative versus postoperative reconstruction dimensions, patellar thickness and height, and postoperative flexion and compared the results with those patients who did not experience dislocation. Possible etiologies and mechanisms of dislocation were sought. There were no significant differences between the control and study groups for any variable assessed, with the exception of postoperative flexion, which averaged 118 degrees for the study group and 105 degrees for the control group (P < .001). Conservative management was successful in 11 cases. In September 1988 the IB-II system was introduced; modification of the tibial insert was made in January 1990.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

18.
Postoperative knee flexion in patients undergoing Insall-Burstein-II total knee arthroplasty at 2 years was evaluated regarding two basic questions: what groups of patients gain or lose the most flexion and what groups of patients have the best or worst postoperative flexion. Thirteen preoperative variables (maximum flexion, flexion arc, tibiofemoral angle, quadriceps strength, extensor lag, Knee Society score, Knee Society patient assessment, gender, age, height, weight, diagnosis, and surgeon) and four postoperative variable (leg length change, tibiofemoral angle, distance from patella to the joint line, and the tibial prosthesis anteroposterior translation on a lateral radiograph) were used in an attempt to explain postoperative flexion. The analysis was performed on 164 consecutive Insall-Burstein-II total knees in which the data were gathered prospectively on a time oriented medical record database. A regression tree analysis was used to identify several groups of patients, characterized by preoperative factor values, who had markedly above average performance on postoperative flexion. The preoperative factors identified include preoperative flexion, flexion arc, tibiofemoral angle, extensor lag, diagnosis, and age. The only postoperative variable of significance was tibiofemoral angle. Among the potential determinants of postoperative flexion that failed to appear predictive were the Knee Society scores and surgeon. Preoperative flexion is known to be a critical determinant of postoperative flexion in total knee replacement. However, in the current study, preoperative flexion accounted for only half of the difference between the best (122 degrees) and the worst (88 degrees) group, as determined with regression tree analysis.  相似文献   

19.
During evaluation of 29 Ortholoc II tibial polyethylene components retrieved at revision surgery, the authors noticed that components with a lot number prefix of CP (Custom Product) consistently had minimal wear and those with a standard lot number had severe wear, regardless of patient age, weight, gender, and activity level. Non-CP components had earlier and more severe wear than CP components in service for the same amount of time. Microscopic evaluation of the polyethylene revealed major differences in the material. Large subsurface cracks, fusion defects, and intergranular cracks were present in the non-CP components, but these defects were minimal or nonexistent in the CP components. The components with defects had a significantly greater delamination rate than those without defects. Gamma irradiation did not seem to accelerate wear or delamination, because irradiated components that had minimal microscopic signs of fusion defects performed as well as nonirradiated components with a similar microscopic appearance. The manufacturing details disclosed that different materials and processing methods were used for the 2 groups. The results from this study suggest that improved quality control of polyethylene material would greatly decrease wear and delamination of total knee arthroplasty components.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号