共查询到20条相似文献,搜索用时 19 毫秒
1.
本文介绍采样时和采样后测量混合氡氢子体浓度的方法,编成多用途计算机程序,计算给出了最佳采样和测量时间,用逆矩阵和加权最小二乘法处理测量数据,得到了较精确的测定结果。 相似文献
2.
3.
<正>Soil radon measurement of high stability and sensitivity is widely applied,and in some applications,such as in uranium prospecting,~(222)Rn should be distinguished from ~(220)Rn.To meet this requirement,a practical method based on soil radon diffusion and accumulation theory to measure soil radon by Alpha Particle Spectroscopy(α-PS)is discussed in this paper.Theα-PS measurement method can effectively overcome the effects of ~(220)Rn and its daughters (~(216)Po,~(212)Bi,~(212)Po).The system can eliminate the impact of soil radon field disturbance and non-uniformity through soil radon static diffusion.Radon daughters(~(218)Po,~(214)Po)are accumulated under the action of an electrostatic force, which not only enhances the measurement sensitivity,but also increases robustness of the measurement.Simultaneous measurement of multiple points can increase the comparability of measurement data and the measurement efficiency. Experimental data shows that the soil radon measurement method was robust.So it has wide applications such as in geological prospecting,in fissure groundwater exploration and in ground subsidence inspection. 相似文献
4.
5.
室内氡子体的行为和防护措施 总被引:3,自引:0,他引:3
室内氡对居民的辐射危害主要来自吸入氧的短寿命衰变产物。空气中的凝结核(例如粉尘或烟雾)的浓度是影响氡子体附着和沉积速率的主要因素。本文给出了氡子体浓度和通风、附着和沉积、以及放射性衰变之间的关系。并介绍了沉积速率的直接测量方法。基于对室内氡子体来源和行为的研究,推荐了控制居民的氡子体照射的一些措施(包括降低氡浓度和降低氡子体浓度),并简单地讨论了各种措施的有效性和局限性。 相似文献
6.
利用matlab仿真产生了氡及其子体的仿核脉冲数据,它满足氡及其子体的衰变规律;同时根据产生的数据,利用matlab仿真延迟符合法分辨氡的短寿命同位素~(219)Rn;探索在延迟符合测量氡短寿命同位素~(219)Rn最佳的开门时间;通过仿真对符合测量装置的研究具有指导作用. 相似文献
7.
《IEEE transactions on nuclear science》2005,52(4):932-937
An image acquisition system is presented for use with position sensitive detectors (PSD). The system is based on a high-resolution time-to-digital converter (TDC) and a field programmable gate array (FPGA). The detectors use gas as absorbing medium and two delay lines to identify the coordinates of each detected particle. The TDC translates the time information coming from the delay lines into digital words, from which the particle position coordinates are encoded. The FPGA is responsible for processing each event, controlling the data acquisition and communicating with a personal computer. 256 pixels$times$ 256 pixels images are stored into an on-board memory. This resolution is increased to 512 pixels$times$ 512 pixels by using a time multiplexing technique. The maximum data acquisition rate is 1.2 million events per second. X-ray images obtained with the system are shown, which illustrate the overall performance. 相似文献
8.
Todd J.H. Rooney B.D. Spencer R.H. Weston L.W. 《IEEE transactions on nuclear science》1993,40(2):166-169
A multiparameter data acquisition system for the Oak Ridge Electron Linear Accelerator (ORELA) is described. This system uses a personal computer and a data handler with a 2048-word buffer. The buffer can accept data at a rate exceeding one million events per second in bursts of 512 words 64-b in length. The acquisition system, limited by software, can acquire data from one, two or three digitizers; multiplex up to four detectors; read and control up to 16 scalers or registers; and output up to 32 DC logic lines that can be used to control external instrumentation. Software was developed for the OS/2 operating system, supporting multiparameter data storage for up to those million channels. Data can be collected in background mode to make the computer available for other tasks while collecting data. The system supports multiparameter biasing and can collect, crunch, and store data at rates of 30000 events/s, each event containing up to 64 b of information 相似文献
9.
10.
11.
12.
针对运用动态稳定技术实现氡室氡浓度稳定的密闭型氡室,推导了氡室氡及其短寿子体浓度的变化规律公式;通过详细分析首次补氡和中途补氡过程中密闭型氡室中放射性平衡变化规律,得出密闭型氡室进入放射性平衡期后,氡箱中的氡及其短寿子体长期处在平衡或近平衡状态,工作在平衡期的氡室可以开展仪器标定、调整结合态份额等实验和工作。该研究方法和成果为进一步开展氡室氡子体潜能浓度控制、放射性气溶胶浓度控制、氡子体动力学行为研究提供了方法和理论基础。 相似文献
13.
关于氡若干问题的讨论(一) 总被引:3,自引:0,他引:3
本文仅就提出的当前影响氡的研究及其发展的若干主要问题进行了讨论,并在此基础上提出了若干应予重视和解决的具体问题。其中有属于认识上的若干问题,它们是:氡的两种平衡与检测的问题;氡子体是氡致害的祸首;氡的多元控制和迁移问题;水中氡和壤中氡的重要性;建筑工程场地设计和评价的重要标准;对氡及其子体危害机制问题的一些思考;高氡与低氡都会致病;氡在室内不会很快消失;天然大理石一般不会有高氡等等;而另外几个问题则属于要具体解决的问题,如,尽快制定全国统一的氡标准;完善现场检测技术并开展全国性多学科的氡普查;加强氡危害机制的研究;尽快成立全国氡研究中心等。 相似文献
14.
为了弄清某矿山的辐射环境现状,在2005年5月至2007年5月期间,使用各种辐射监测仪器对该矿山的工作场所和生活区分别进行氡及其子体浓度、γ辐射水平、土壤和岩石中天然放射性核素含量的测量。结果表明,在所监测的工作场所中,大部分监测点的氡及其子体浓度和Y辐射水平低于核工业辐射环境质量评价中的管理限值;在居民区,扣除本底后所有监测点的个人剂量也都低于核工业辐射环境质量评价中的管理限值。 相似文献
15.
16.
为实现反应堆不同空间和能量的相对中子通量密度在线监测,本文研究开发了一套新型的用于狭小空间且位置灵敏的闪烁体中子探测系统。该套系统由5种探头、5路光子计数器、1台计算机及相应的软件组成。5种探头的主要构成物质分别为~6 LiF+ZnS(Ag)、~(232) ThO_2+ZnS(Ag)、~(238) UO_2+ZnS(Ag)、~9Be+ZnS(Ag)以及BGO晶体,故可测量不同能量的相对中子通量密度。其中,掺有~6 LiF的探头用于热中子的测量,BGO探头用于γ测量,其余3种探头用于快中子的测量。利用该系统进行了启明星1#装置内热中子及快中子的相对通量密度分布测量,并将测量结果与利用蒙特卡罗方法得到的理论分布结果进行了比较。考虑到理论设置参数与实际实验参数的差别,可认为测量结果是可信的。 相似文献
17.
采用固体径迹蚀刻法和瞬时法对成都某办公场所室内氡活度浓度展开调查研究。结果表明:该办公场所室内累积氡活度浓度的范围为10.82~102.50 Bq/m3,算术平均值为(36.56±17.38) Bq/m3,低于全国和世界平均水平。调查研究证实了玻璃墙体和橡胶地面等新型装修材料可有效减少室内氡,验证了通风是降低室内氡活度浓度的有效措施。研究发现,环境空气质量中高浓度的PM2.5和PM10对办公场所室内和户外氡活度浓度水平均会产生影响。通过发现污染并处理低本底实验室内的氡活度浓度异常给出建议:避免放射性核素浓度较高的样品暂存于测试设备附近;为降低氡及子体对测试的干扰,提高分析结果的准确度,建议升级改造低本底实验室的新风系统。 相似文献
18.
19.
20.
用复合砂浆防止来自楼房建筑物内混凝土氡污染的研究 总被引:5,自引:0,他引:5
介绍了一种用复合砂浆来降低楼房内混凝土材料所释放的氡气浓度的方法,进行了实验室试验和实际楼房的试验研究。实验室的试验中,利用扫描电子显微镜(SEM)等现代微观分析方法,探讨了楼房内部混凝土材料所释放的氡气来源,用不同的方法测试了复合砂浆的有效性。结果表明,该材料具有良好的阻止氡释放的能力和优良的屏蔽放射线的作用,同时也兼备普通砂浆的力学强度等性能,以及与普通砂浆基本相同的使用方法;实际楼房的试验现场是某高层住宅楼房内一个约60m^2的单元房,用阿尔法轨迹仪检测,封闭一周后本底氡浓度达2500Bq/m^3,应用本材料后氡浓度减至200Bq/m^3,平均减少90%。 相似文献