首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The actin cytoskeleton is a main component of cells and it is crucially involved in many physiological processes, e.g. cell motility. Changes in the actin organization can be effected by diseases or vice versa. Due to the nonuniform pattern, it is difficult to quantify reasonable features of the actin cytoskeleton for a significantly high cell number. Here, we present an approach capable to fully segment and analyse the actin cytoskeleton of 2D fluorescence microscopic images with a special focus on stress fibres. The extracted feature data include length, width, orientation and intensity distributions of all traced stress fibres. Our approach combines morphological image processing techniques and a trace algorithm in an iterative manner, classifying the segmentation result with respect to the width of the stress fibres and in nonfibre‐like actin. This approach enables us to capture experimentally induced processes like the condensation or the collapse of the actin cytoskeleton. We successfully applied the algorithm to F‐actin images of cells that were treated with the actin polymerization inhibitor latrunculin A. Furthermore, we verified the robustness of our algorithm by a sensitivity analysis of the parameters, and we benchmarked our algorithm against established methods. In summary, we present a new approach to segment actin stress fibres over time to monitor condensation or collapse processes.  相似文献   

2.
A theory for multiphoton fluorescence imaging in high aperture scanning optical microscopes employing finite sized detectors is presented. The effect of polarisation of the fluorescent emission on the imaging properties of such microscopes is investigated. The lateral and axial resolutions are calculated for one-, two- and three-photon excitation of p-quaterphenyl for high and low aperture optical systems. Significant improvement in lateral resolution is found to be achieved by employing a confocal pinhole. This improvement increases with the order of the multiphoton process. Simultaneously, it is found that, when the size of the pinhole is reduced to achieve the best possible resolution, the signal-to-noise ratio is not degraded by more than 30%. The degree of optical sectioning achieved is found to improve dramatically with the use of confocal detection. For two- and three-photon excitation axial full width half-maximum improvement of 30% is predicted.  相似文献   

3.
We present an integrated light‐electron microscope in which an inverted high‐NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high‐resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub‐10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum‐compatible immersion oil. For a 40‐nm‐diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry.  相似文献   

4.
The use of fast-staining DNA-specific dyes such as DAPI or Hoechst 33342/33258 has been a major problem for confocal scanning laser microscopy (CSLM) studies of intranuclear chromatin organization. Moreover, the availability of a confocal ultraviolet scanning laser microscope configuration, which allows an excitation at wavelengths of 364 nm as well as 488, 514 and 543 nm, is a prerequisite for single as well as multiple fluorescence parameter studies, especially if these studies are concerned with the precise localization of intranuclear signals. Here we report the characteristics and application of a CSLM, which was adapted for UV-excitation and therefore enables comparison of the spatial distribution of several types of signals within one preparation. In addition to multiple-parameter studies, we have also investigated the sensitivity of the system with regard to the identification of the double-stranded DNA of lampbrush chromosome loops in germinal vesicles of amphibian oocytes.  相似文献   

5.
6.
We have developed a near‐video‐rate dual‐mode reflectance and fluorescence confocal microscope for the purpose of imaging ex vivo human specimens and in vivo animal models. The dual‐mode confocal microscope (DCM) has light sources at 488, 664 and 784 nm, a frame rate of 15 frames per second, a maximum field of view of 300 × 250 μm and a resolution limit of 0.31 μm laterally and 1.37 μm axially. The DCM can image tissue architecture and cellular morphology, as well as molecular properties of tissue, using reflective and fluorescent molecular‐specific optical contrast agents. Images acquired with the DCM demonstrate that the system has the sub‐cellular resolution needed to visualize the morphological and molecular changes associated with cancer progression and has the capability to image animal models of disease in vivo. In the hamster cheek pouch model of oral carcinogenesis, the DCM was used to image the epithelium and stroma of the cheek pouch; blood flow was visible and areas of dysplasia could be distinguished from normal epithelium using 6% acetic acid contrast. In human oral cavity tissue slices, DCM reflectance images showed an increase in the nuclear‐to‐cytoplasmic ratio and density of nuclei in neoplastic tissues as compared to normal tissue. After labelling tissue slices with fluorescent contrast agents targeting the epidermal growth factor receptor, an increase in epidermal growth factor receptor expression was detected in cancerous tissue as compared to normal tissue. The combination of reflectance and fluorescence imaging in a single system allowed imaging of two different parameters involved in neoplastic progression, providing information about both the morphological and molecular expression changes that occur with cancer progression. The dual‐mode imaging capabilities of the DCM allow investigation of both morphological changes as well as molecular changes that occur in disease processes. Analyzing both factors simultaneously may be advantageous when trying to detect and diagnose disease. The DCM's high resolution and near‐video‐rate image acquisition and the growing inventory of molecular‐specific contrast agents and disease‐specific molecular markers holds significant promise for in vivo studies of disease processes such as carcinogenesis.  相似文献   

7.
陶振强  贾南南  阮斌 《光学仪器》2015,37(2):170-174
为了获得细胞图像,利用Visual Studio C#开发了移动位移平台的控制程序,使用位移平台单点扫描的方式设计激光共聚焦扫描显微镜(laser confocal scanning microscope,LCSM)。为了获得高分辨率的位移,位移由精度可以达到1nm的压电陶瓷驱动器驱动。设计了梳状和矩形两种扫描路径,通过程序设计位移补偿的方法弥补了机械运动的偏差。利用算术平均值的数字滤波方法处理数据采集卡采集的数据以减小随机噪声的影响。实验结果证明,利用C#程序控制的单点式平台扫描LCSM具有较好地测量效果。  相似文献   

8.
Three levels of organization in DNA structure in the interphase cell nucleus are assessed by confocal laser scanning microscopy: (i) the conformational state of the double helix; (ii) the distribution of eu- and heterochromatin; and (iii) the localization of replication complexes throughout S phase. Multi-parameter measurements were carried out in each optical section using two laser sources and combined stereoscopic reconstructions were used to assess the co-localization of nuclear components. DNA is highly polymorphic and can adopt a variety of different helical conformations as well as unusual structures (curved, cruciform, multi-stranded). We have assessed by laser scanning microscopy the presence of left-handed Z-DNA in polytene chromosomes of Diptera as well as the spatio-temporal distribution of Z-DNA binding proteins in whole-mount Drosophila embryos and ovaries. We have determined the 3-D distribution of replication sites relative to heterochromatin regions, nucleoli and nuclear membrane by using short pulses of BrdU incorporation in synchronized mouse and human fibroblasts. Replication sites were visualized with a monoclonal anti-BrdU antibody combined with DNA fluorescent staining and antibody labelling of nuclear lamin. The implications of dynamic DNA movement and structural rearrangement to the organization of the nucleus in domains are discussed.  相似文献   

9.
Filamentous bacteriophage has been proposed as a vehicle that can carry and deliver therapeutics into mammalian cells for disease treatment, thus a protocol for imaging phage‐cell interaction is essential. Because high signal intensity is necessary to study the mechanism of interaction between filamentous bacteriophage and mammalian cells, it is important to optimize the procedure for fluorescence labeling of phage in order to understand such interaction. Here, we describe a procedure that gives intense fluorescence labeling and can show interactions between fd‐tet bacteriophage selected from phage libraries and mammalian cells (SKBR‐3 and MCF‐10A). The indirect labeling of phage with dye‐conjugated antibody and cytoskeleton associated proteins was significantly enhanced in the presence of a cross‐linking reagent called dithiobissuccinimidylpropionate (DSP) as shown by qualitative and quantitative fluorescence microscopy. The use of DSP resulted in high signal intensity in fluorescence imaging of phage‐cell complex. The DSP cross‐linker is believed to preserve soluble unbound proteins for fluorescence imaging. The interaction between the phage and mammalian cells was further confirmed by scanning electron microscopy. Microsc. Res. Tech., 2010. © 2009 Wiley‐Liss, Inc.  相似文献   

10.
Confocal microscopy is based on measurement of intensity of fluorescence originating from a limited volume in the imaged specimen. The intensity is quantized in absolute (albeit arbitrary) units, producing a digital 3D micrograph. Thus, one may obtain quantitative information on local concentration of biomolecules in cells and tissues. This approach requires estimation of precision of light measurement (limited by noise) and conversion of the digital intensity units to absolute values of concentration (or number) of molecules of interest. To meet the first prerequisite we propose a technique for measurement of signal and noise. This method involves registration of a time series of images of any stationary microscope specimen. The analysis is a multistep process, which separates monotonic, periodic and random components of pixel intensity change. This approach permits simultaneous determination of dark and photonic components of noise. Consequently, confidence interval (total noise estimation) is obtained for every level of signal. The algorithm can also be applied to detect mechanical instability of a microscope and instability of illumination source. The presented technique is combined with a simple intensity standard to provide conversion of relative intensity units into their absolute counterparts (the second prerequisite of quantitative imaging). Moreover, photobleaching kinetics of the standard is used to estimate the power of light delivered to a microscope specimen. Thus, the proposed method provides in one step an absolute intensity calibration, estimate of precision and sensitivity of a microscope system.  相似文献   

11.
李兵  蔡贵民 《光学仪器》2020,42(3):9-14
为实现物质荧光量子产率的绝对法测量,研制了一套绝对荧光量子产率测量系统。系统主机采用国产荧光分光光度计,激发和发射波长范围均为200~900 nm。光路设计采用积分球技术,保证了样品的散射和发射光线被充分收集,具备进行绝对法荧光量子产率计算的基础。光谱校正采用罗丹明B量子计数器和标准钨灯相结合的方式,确保测量结果的准确性。研制的荧光量子产率分析软件具备自动光谱校正和自动计算量子产率功能。测试结果表明,系统的测量准确性较高,可满足大部分荧光物质的测试要求。  相似文献   

12.
We demonstrate the possibility to increase substantially the number of simultaneously detected fluorophores by utilizing both spectral and lifetime information. Using a two-detector confocal scanning laser microscope, experiments confirm that four different fluorophores can be detected with good channel separation. The signal-to-noise ratio (SNR) of the recorded images is investigated both theoretically and experimentally. It is found that in order to obtain a high SNR fluorophore lifetimes should differ by approximately an order of magnitude.  相似文献   

13.
Video microscopy, including video-enhanced contrast, ultraviolet and video-intensified fluorescence microscopy, was applied to the visualization and analysis of organelles and cytoskeletal elements at the border of resolution of the light microscope. We describe the principles of video microscopy and the necessary technical equipment, and discuss the advantages and limitations with the example of three selected plant cells. In characean internodal cells we observed the motility and disappearance of Golgi secretory vesicles during wound wall formation by video-enhanced contrast microscopy. In Byblis gland hairs we investigated the movement of different organelles along bundles of actin microfilaments by ultraviolet microscopy, and in onion inner epidermal cells we visualized the arrangement of actin microfilaments during different stages of plasmolysis with video-intensified fluorescence microscopy.  相似文献   

14.
Thin, uniformly fluorescing reference layers can be used to characterize the imaging conditions in confocal, or more general, sectioning microscopy. Through-focus datasets of such layers obtained by standard microscope routines provide the basis for the approach. A set of parameters derived from these datasets is developed for defining a number of relevant sectioned imaging properties. The main characteristics of a particular imaging situation can then be summarized in a Sectioned Imaging Property-chart or SIPchart. We propose the use of such charts for the characterization of imaging properties in confocal and multiphoton microscopy. As such, they can be the basis for comparison of sectioned imaging condition characteristics, quality control, maintenance or reproduction of sectioned imaging conditions and other applications. Such charts could prove useful in documenting the more relevant properties of the instrumentation used in microscopy studies. The method carries the potential to provide the basis for a general characterization of sectioned imaging conditions as the layers employed can be characterized and fabricated to standard specifications. A limited number of such thin, uniformly fluorescing layers is available from our group for this purpose. Extension of the method to multiphoton microscopy is discussed.  相似文献   

15.
We develop a method, which utilizes a combined atomic force microscope (AFM)/fluorescence microscope and small copy number polymerase chain reaction (PCR), to affinity-select individual aptamer species in a single cycle from a small pool of random-sequence oligonucleotides (oligos). In this method, a library of small beads, each of which is functionalized with fluorescent oligos of different sequences, is created. This library of oligo-functionalized beads is flowed over immobilized target molecules on a glass cover slip. High-affinity target-specific aptamers bind tightly to the target for prolonged periods and resist subsequent washes, resulting in a strong fluorescence signal on the substrate surface. This signal is observed from underneath the sample via fluorescence microscopy. The AFM tip, situated above the sample, is then directed to the coordinates of the fluorescence signal and is used to capture a three-dimensional high-resolution image of the surface-bound bead and to extract the bead (plus attached oligo). The extracted oligo is PCR-amplified, sequenced, and may then be subjected to further biochemical analysis. Here, we describe the underlying principles of this method, the required microscopy instrumentation, and the results of proof-of-principle experiments. In these experiments, we selected aptamers in eight trials from a binary pool containing a 1:1 mixture of thrombin aptamer oligo and a nonsense oligo. In each of the eight trials, the positive control aptamer was successfully detected, imaged, extracted, and characterized by PCR amplification and sequencing. In no case was the nonsense oligo selected, indicating good selectivity at this early stage of technology development.  相似文献   

16.
In this paper, we present a new experimental methodology to combine mass spectrometry (NanoSIMS) with fluorescence microscopy to provide subcellular information on the location of small molecules in cultured cells. We demonstrate this by comparing the distribution of 5-bromo-2-deoxyuridine in the same cells given by both NanoSIMS analysis and by fluorescence immunohistochemistry. Fiducial markers in the substrates ensured that the images formed by SIMS mapping of bromine ions could be co-registered exactly with images from fluorescence microscopy. The NanoSIMS was shown to faithfully reproduce the information from fluorescence microscopy, but at a much higher spatial resolution. We then show preliminary SIMS images on the distribution of ATN-224, a therapeutic copper chelator for which there is no fluorescent marker, co-registered with conventional Lysotracker and Hoechst stains on the same cells.  相似文献   

17.
High hydrostatic pressure (HHP) becomes more and more interesting for life science research, since it can be employed to inactivate various cells. To directly monitor "cells under pressure," the development of an optical high-pressure chamber is required. Therefore, an optical pressure chamber that can be used for up to 300 MPa was constructed. This chamber has already been described as a tool for in situ observation of dynamic changes of microscopic structures in bright field as well as phase contrast. In combination with an inverted microscope, we obtained brilliant microscopic color pictures with an optical resolution more than 0.56 microm. Here, we demonstrate the capabilities of the HHP cell, in combination with epifluorescence microscopy. Using a nonadherent human B-cell line (Raji, ATCC CCL 86), stained with the fluorescent dyes propidium iodide, Hoechst 33342, or dihexyloxacarbocyanine iodide, we were able to show that the system is suitable to perform fluorescence microscopic analyses, with pressures up to 300 MPa, with viable mammalian cells.  相似文献   

18.
Three-dimensional confocal imaging of polymer samples was achieved by the use of two-photon excited fluorescence in both positive and negative contrast modes. The fluorophore was a new and highly efficient two-photon induced upconverter, resulting in improved signal strength at low pumping power. Because of the relatively long wavelength of the excitation source (798 nm from a mode-locked Ti:Sap-phire laser), this technique shows a larger penetration depth into the samples than provided by conventional single-photon fluorescence confocal microscopy. Single-photon and two-photon images of the same area of each sample show significant differences. The results suggest the possibility of using two-photon confocal microscopy, in conjunction with highly efficient fluorophores, as a tool to study the surface, interface, and fracture in material science applications.  相似文献   

19.
The detection of mitochondrial DNA (mtDNA) in living human cells could be useful for understanding mitochondrial behaviour during cellular processes and pathological mtDNA depletions. However, until now, human mtDNA has not been visualized in living cells with fluorescence microscopy, although it has been easily detected in organisms with larger mtDNA. Previous reports have stated that mtDNA staining results in homogeneous fluorescence of mitochondria or that animal mitochondria are refractory to DAPI staining. This paper shows that mtDNA of cultured green monkey kidney CV-1 can be stained using a very low concentration of DAPI, then detected by a cooled Photometrics CCD camera with 14-bit resolution detection. Indeed, under these conditions CV-1 cells have small fluorescent spots in the cytoplasm that colocalize with mitochondria, even after mitochondrial movements, uncoupling by carbonyl cyanide p-(trifluoromethoxy)phenylhydrazone and swelling. These observations have been reproduced for the human fibroblast foreskin cell line HS68. These results and known properties of DAPI as a specific DNA stain strongly suggest that mtDNA can be detected and visualized by fluorescence microscopy in human living cells, with potential developments in the study of mtDNA in normal and pathological situations.  相似文献   

20.
We have measured the point-spread function (PSF) for an MRC-500 confocal scanning laser microscope using subresolution fluorescent beads. PSFs were measured for two lenses of high numerical aperture—the Zeiss plan-neofluar 63 × water immersion and Leitz plan-apo 63 × oil immersion—at three different sizes of the confocal detector aperture. The measured PSFs are fairly symmetrical, both radially and axially. In particular there is considerably less axial asymmetry than has been demonstrated in measurements of conventional (non-confocal) PSFs. Measurements of the peak width at half-maximum peak height for the minimum detector aperture gave approximately 0·23 and 0·8 μm for the radial and axial resolution respectively (4·6 and 15·9 in dimensionless optical units). This increased to 0·38 and 1·5 μm (7·5 and 29·8 in dimensionless units) for the largest detector aperture examined. The resulting optical transfer functions (OTFs) were used in an iterative, constrained deconvolution procedure to process three-dimensional confocal data sets from a biological specimen—pea root cells labelled in situ with a fluorescent probe to ribosomal genes. The deconvolution significantly improved the clarity and contrast of the data. Furthermore, the loss in resolution produced by increasing the size of the detector aperture could be restored by the deconvolution procedure. Therefore for many biological specimens which are only weakly fluorescent it may be preferable to open the detector aperture to increase the strength of the detected signal, and thus the signal-to-noise ratio, and then to restore the resolution by deconvolution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号