首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Many ice rink arenas have ice resurfacing equipment that uses fossil fuel as power. The combustion byproducts are a major source of contamination. Ventilation along with other pollution source control measures is the most widely applied strategy to lower the contaminant level below the threshold limit and maintain acceptable indoor air quality (IAQ). A computational fluid dynamics (CFD) model has been developed and used to predict the contaminant concentrations, air velocity, and air temperature distributions in ice rinks. The numerical results agree reasonably with the corresponding experimental data for both steady-state and transient conditions. The CFD model is a useful and inexpensive tool to investigate ventilation parameters, such as air distribution methods, ventilation effectiveness, air exchange rates, and various ventilation control strategies.  相似文献   

2.
Building heating, ventilation and air-conditioning (HVAC) system can be potential contaminant emission source. Released contaminants from the mechanical system are transported through the HVAC system and thus impact indoor air quality (IAQ). Effective control and improvement measures require accurate identification and prompt removal of contaminant sources from the HVAC system so as to eliminate the unfavourable influence on the IAQ. This paper studies the application of the adjoint probability method for identifying a dynamic (decaying) contaminant source in building HVAC system. A limited number of contaminant sensors are used to detect contaminant concentration variations at certain locations of the HVAC ductwork. Using the sensor inputs, the research is able to trace back and find the source location. A multi-zone airflow model, CONTAM, is employed to obtain a steady state airflow field for the studied building with detailed duct network, upon which the adjoint probability based inverse tracking method is applied. The study reveals that the adjoint probability method can effectively identify the decaying contaminant source location in building HVAC system with few properly located contaminant concentration sensors.  相似文献   

3.
本文首先阐述了研究室内空气品质(IAQ)问题的重要性和必要性,介绍了目前已有的与室内空气品质相关的模拟软件。而后,基于"室内健康、环保和节能"的理念,提出了新的室内污染物浓度动态网络模拟分析与评估软件(DeST-IAQ)的理论框架,主要是将自然通风通路和机械通风网络集成,构成建筑通风和污染物传播的多区域网络模型,实现建筑通风和污染物浓度的联合动态预测,解决建筑通风模型、热模型和IAQ模型统一模拟的难题,满足建筑物能耗和室内空气品质预测的双重需求。该软件已在一些实际案例中得到了初步应用,其实用性具有较好的实验验证。  相似文献   

4.
Indoor air quality (IAQ) has a significant influence on occupants' comfort, health, productivity, and safety. Existing studies show that the primary causes of many IAQ problems are various airborne contaminants that either are generated indoors or penetrate into indoor environments with passive or active airflows. Accurate and prompt identification of contaminant sources can help determinate appropriate IAQ control solutions, such as, eliminating contaminant sources, isolating and cleaning contaminated spaces. This study develops a fast and effective inverse modeling method for identifying indoor contaminant source characteristics. The paper describes the principles of the probability-based adjoint inverse modeling method and formulates a multi-zone model based inverse prediction algorithm that can rapidly track contaminant source location with known source release time in a building with many compartments. The paper details the inverse modeling procedure with modification of an existing multi-zone airflow and contaminant transport simulation program. The application of the method has been demonstrated with two case studies: contaminant releases in a multi-compartment residential house and in a complex institutional building. The numerical experiments tested the source identification capability of the program for various contaminant sensing scenarios. The investigation verifies the effectiveness and accuracy of the developed method for indoor contaminant source tracking, which will be further explored to identify more complicated indoor contamination episodes.  相似文献   

5.
Building modelers need simulation tools capable of simultaneously considering building energy use, airflow and indoor air quality (IAQ) to design and evaluate the ability of buildings and their systems to meet today’s demanding energy efficiency and IAQ performance requirements. CONTAM is a widely-used multizone building airflow and contaminant transport simulation tool that requires indoor temperatures as input values. EnergyPlus is a prominent whole-building energy simulation program capable of performing heat transfer calculations that require interzone and infiltration airflows as input values. On their own, each tool is limited in its ability to account for thermal processes upon which building airflow may be significantly dependent and vice versa. This paper describes the initial phase of coupling of CONTAM with EnergyPlus to capture the interdependencies between airflow and heat transfer using co-simulation that allows for sharing of data between independently executing simulation tools. The coupling is accomplished based on the Functional Mock-up Interface (FMI) for Co-simulation specification that provides for integration between independently developed tools. A three-zone combined heat transfer/airflow analytical BESTEST case was simulated to verify the co-simulation is functioning as expected, and an investigation of a two-zone, natural ventilation case designed to challenge the coupled thermal/airflow solution methods was performed.  相似文献   

6.
Abstract Many factors affect the airflow patterns, contaminant removal efficiency and the indoor air quality at individual workstations in office buildings. The effects of office furniture design and workstation layouts on ventilation performance, contaminant removal efficiency and thermal comfort conditions at workstations were studied. The range of furniture configurations and environmental parameters investigated included: 1) partition heights, 2) partition gap size, 3) diffuser types, 4) supply air diffuser location relative to the workstation, 5) return air grill location relative to the workstation, 6) heat source locations, 7) presence of furniture, 8) supply air temperatures, 9) adjacent workstations, 10) contaminant source locations, 11) supply air flow rates, and 12) outdoor air flow rates. The tracer gas technique was used to study experimentally the relative impact of these parameters on the air distribution and ventilation performance, as well as contaminant removal efficiency. Thermal environmental parameters such as air velocity and temperature were monitored at several locations to characterize the impact of these parameters on the thermal comfort conditions. The results showed that the outdoor air flow rate had a significant influence on the mean age of air. The air distributions at all the workstations were good even when the supply air flow rate was relatively low (i.e 5 L/s). At the same time, most of the parameters tested had a significant influence on contaminant removal efficiency when there was a contaminant source present somewhere in the office.  相似文献   

7.
Large variation in indoor air quality (IAQ) and thermal comfort can occur in partitioned office spaces due to heterogeneous air mixing. However, few published studies examined IAQ, thermal comfort, and energy performance of partitioned occupied spaces, which are commonly found in today’s buildings. The objective of this study is to evaluate indoor environmental quality and air conditioning performance of a partitioned room under two typical ventilation modes: (1) mixing ventilation and (2) displacement ventilation. For a total of six representative air-conditioning scenarios, three-dimensional computational fluid dynamics (CFD) simulations are performed to examine temperature distribution, ventilation effectiveness, energy consumption, and local thermal comfort for two partitioned spaces. Simulation results indicate that temperature distribution in a partitioned room is a strong function of ventilation strategy (mixing vs. displacement), but marginally affected by diffuser arrangements. Local age-of-air (air freshness) significantly varies with both diffuser arrangement and ventilation strategy. Regarding energy consumption, displacement ventilation can achieve an indoor set-point temperature in the partitioned spaces about two times faster than mixing ventilation. Under mixing ventilation, the time to achieve a set-point temperature was notably reduced when each partitioned space is served by its own diffuser. For the same supply airflow rate, displacement ventilation can generate local draft risk at ankle level, while mixing ventilation may result in a draft sensation in wider areas around an occupant. Overall, the results suggest that mixing ventilation system can save energy if each partitioned zone is served by its own diffuser such as a multi-split air conditioning. However, when multiple partitioned zones are served by only one diffuser, displacement ventilation is more energy-efficient and can achieve higher ventilation effectiveness than mixing ventilation.  相似文献   

8.
To evaluate the control effect on indoor air quality (IAQ) of the local ventilation systems in industrial buildings with centralized contaminant sources, a new index, namely, normalized concentration in the target zone (NC-TZ), was proposed in this paper. According to theoretical analysis, NC-TZ is non-dimensional and ranges from 0 to 1. When NC-TZ tends toward 0, the control effect of the local ventilation system on IAQ is more satisfactory. When NC-TZ tends toward 1, the control effect on IAQ is less satisfactory. The numerical simulation on a push–pull ventilation system with varying exhaust flow rates and varying distances between push and pull hoods was performed. The results demonstrate that for the same capture efficiency, changing the local ventilation system characteristics can change the control effect on the local environment. The results for obstacles at different positions also indicate that NC-TZ can clearly reflect the control effect on IAQ of the local ventilation systems in industrial buildings.  相似文献   

9.
He G  Yang X  Srebric J 《Indoor air》2005,15(5):367-380
This paper presents the experimental and numerical modeling of contaminant dispersion in a full-scale environmental chamber with different room air distribution systems. For the experimental modeling, an area source with uniform emissions of a hypothetical contaminant (SF6) from the entire floor surface is designed and constructed. Two different types of ventilation are studied: displacement and mixing ventilation. A computer model for predicting the contaminant dispersion in indoor spaces was validated with experimental data. The validated model is used to study the effects of airflow and the area-source location on contaminant dispersion. Results show that the global airflow pattern has a strong impact on the distribution of the contaminants. In general, the personal exposure could be estimated by analyzing the relative source positions in the airflow pattern. Accordingly, the location of an exhaust diffuser may not greatly affect the airflow pattern, but can significantly affect the exposure level in the room. PRACTICAL IMPLICATIONS: When designing ventilation in addition to bringing fresh air to occupants, it is important to consider the removal of contaminants released in the off-gassing of building materials. Typical indoor off-gassing examples are emissions of volatile organic compounds from building enclosure surfaces such as flooring and painted walls. In this study, we conducted experimental and numerical modeling of different area sources in a mock-up office setup, with displacement or mixing ventilation. Displacement ventilation was as successful as mixing ventilation in removing the contaminant source from the floor area. Actually, the most important consideration in the removal of these contaminants is the relative position of the area source to the main airflow pattern and the occupied zone.  相似文献   

10.
The purpose of this paper is to evaluate the effects of a building parameter, namely ceiling configuration, on indoor natural ventilation. The computational fluid dynamics (CFD) code Phoenics was used with the RNG k? turbulence model to study wind motion and ventilation flow rates inside the building. All the CFD boundary conditions were described. The simulation results were first validated by wind tunnel experiment results in detail, and then used to compare rooms with various ceiling configurations in different cases. The simulation results generated matched the experimental results confirming the accuracy of the RNG k? turbulence model to successfully predict indoor wind motion for this study. Our main results reveal that ceiling configurations have certain effects on indoor airflow and ventilation flow rates although these effects are fairly minor.  相似文献   

11.
Building indoor air quality (IAQ) has received growing attentions lately because of the extended time people spend indoors and the increasing reports of health problems related to poor indoor environments. Recent alarms to potential terrorist attacks with airborne chemical and biological agents (CBA) have further highlighted the research needs on building vulnerability and protection. To maintain a healthful and safe indoor environment, it is crucial to identify contaminant source locations, strengths, and release histories. Accurate and prompt identification of contaminant sources can ensure that the contaminant sources can be quickly removed and contaminated spaces can be effectively isolated and cleaned. This paper introduces a probability concept based prediction method—the adjoint probability method-that can track potential indoor airborne contaminant sources with limited sensor outputs. The paper describes the principles of the method and presents the general modeling algorithm and procedure that can be implemented with current computational fluid dynamics (CFD) or multi-zone airflow models. The study demonstrates the application of the method for identifying airborne pollutant source locations in two realistic indoor environments with few sensor measurement outputs. The numerical simulations verify the feasibility and accuracy of the method for indoor pollutant tracking applications, which forms a good foundation for developing an intelligent and integrated indoor environment management system that can promptly respond to indoor pollution episodes with effective detection, analysis, and control.  相似文献   

12.
Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: (a) conventional air distribution system with ceiling supply and return; (b) conventional air distribution system with ceiling supply and return near the floor; (c) underfloor air distribution system; and (d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the indoor/outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used.  相似文献   

13.
Surgical site infections (SSIs) are the second to third most common site of health care associated infections (HAIs). It is very important to maintain good indoor air quality (IAQ) and the best ventilation system in the operating theatre (OT) to ensure health and safety for the patient and surgical team, also to reduce the risk of post-operative wound infection. Then a significant consideration in OTs is the control of aerosols, anesthesia gases and smoke. The present paper uses the airflow modeling based on computational fluid dynamics (CFD) to study the indoor climate of a standard ISO5 class OT with an ultraclean air filter system and a total ceiling unidirectional diffuser. The OT has a heating, ventilation, and air conditioning (HVAC) plant with a laminar airflow (LAF) or ultraclean ventilation. A simple method to analyze the effects of different sliding door conditions combined with crossing persons and persons with a stretcher crossing, on the OT climate, airflow patterns and the indoor pressures scheme, is provided. The proposed simulation method, that belongs to the indirect approach for a numerical simulation of solid object movements in a fluid, provides important knowledge on complex flow phenomena combined with multi-physical conditions. Results obtained by transient simulation show disruptions of the airflow inside the OT and different airflow displacement and distribution caused by surgery staff movements and sliding door opening and closing, but in particular static pressure changes in the HVAC plant system with important effects on ventilation system working conditions and its energy performances.  相似文献   

14.
基于置换通风舒适、健康和节能的显著特点,本文回顾了置换通风的发展历程,从室内空气品质和节能等方面阐述了国内外置换通风的研究现状。气流组织、热舒适性和污染物分布是影响置换通风室内空气品质的主要因素,因而论文主要从置换通风的两个显著特性:热力分层和垂直温度梯度的角度讨论了室内热舒适性影响因素和研究现状,从颗粒和气体污染物的分布情况论述污染物对室内空气品质的影响,根据置换通风的气流特性,提出可以把室内污染物分为热源和冷源污染物进行研究;最后简要介绍了置换通风节能的情况和优势。  相似文献   

15.
空调系统新风和回风对室内空气品质的影响   总被引:3,自引:0,他引:3  
分析了目前空调系统新风和回风对室内空气品质的影响,认为室内污染的不断增加是室内品质变坏的主要原因;新风的质量直接影响室内空气品质;回风是室内空气的二次污染源,导出了回风对室内空气污染的理论计算公式,文中认为新风率是20%能明显提高室内空气品质。  相似文献   

16.
通风的有效性与室内空气品质   总被引:46,自引:3,他引:43  
马仁民 《暖通空调》2000,30(5):20-23
指出了通风有效性对改善室内空气品质的重要性,比较了不同送风方式的换气与通风效率,分析了通风效率与室内污染度的关系,最后提出了关于如何提高通风效率的建议。  相似文献   

17.
Zuraimi MS 《Indoor air》2010,20(6):445-457
Ventilation duct cleaning (DC) is widely advocated to provide good indoor air quality (IAQ), health benefits, cost savings, and enhance ventilation system performance. The aim of the present review is to evaluate the scientific evidence as shown in the literature. There is evidence that under normal operating conditions, ventilation ducts can be contaminated with dusts and serve as reservoirs for microbials to proliferate. While controlled experiments noted that contaminants resuspension can elevate exposure levels indoors, no field studies have correlated poor IAQ with duct contamination. Despite high efficiencies of contaminant removal within the ducts during cleaning, reductions for different indoor air pollutants vary widely, where, post-cleaning air pollutants concentrations can be higher than pre-cleaning levels. Further, there are health concerns in the use of biocides, sealants and encapsulants. There is inadequate evidence to show that DC can improve airflow in ducts and reduce energy consumption. Although epidemiological studies indicate suggestive evidence that improperly maintained ducts are associated with higher risks of symptoms among building occupants, this review finds insufficient evidence that DC can alleviate occupant's symptoms. In summary, the need for duct cleanliness has to be properly balanced by the probable generation of indoor pollution resulting from DC and subsequent potential health risks. PRACTICAL IMPLICATIONS: Existing evidence is insufficient to draw solid conclusions regarding positive impact of duct cleaning on IAQ, health benefits, cost savings and HVAC performance. Maintaining duct cleanliness has to be properly balanced by the probable generation of indoor pollution and potential health risks.  相似文献   

18.
本文介绍和综述国外有关置换通风的研究进展,影响置换通风热舒适性和室内空气品质的因素,以及人员活动和热源分布等对置换通风气流组织的影响。  相似文献   

19.
Conventional heating, ventilation, and air conditioning (HVAC) systems are incapable of providing control over individual environments or adjusting fresh air supply based on the dynamic occupancy of individual rooms in an office building. This paper introduces the concept of distributed environmental control systems (DECS) and shows that improvement in indoor air quality (IAQ) and energy efficiency can be achieved by providing required amounts of fresh air directly to the individual office spaces through distributed demand controlled ventilation (DDCV). In DDCV, fresh air is provided to each micro-environment (room or cubicle) based on input from distributed sensors (CO2, VOC, occupancy, etc.) or intelligent scheduling techniques to provide acceptable IAQ for each occupant, rather than for groups or populations of occupants. In order to study DECS, a numerical model was developed that incorporates some of the best available models for studying building energy consumption, indoor air flow, contaminant transport and HVAC system performance. The developed model was applied to a DECS in a model office building equipped with a DDCV system. By implementing DECS/DDCV and intelligent scheduling techniques it is possible to achieve an improvement in IAQ along with a reduction in annual energy consumption compared to conventional ventilation systems.  相似文献   

20.
We performed the experimental and the numerical studies on thermal comfort (TC) and indoor air quality (IAQ) in the lecture room with cooling loads when the operating conditions are changed. Predicted mean vote (PMV) value and CO2 concentration of the lecture room were measured and compared to the numerical results. Both of them showed a reasonable agreement with each other and then we applied the numerical model to analyze TC and IAQ for a couple of different operating conditions. From the results we found that the increment of the discharge angle of 4-way cassette air-conditioner makes uniformity of TC worse, but rarely affects IAQ. It turned out that TC and IAQ are hardly affected by the variation of the discharge airflow. Finally TC was merely affected by the increment of the ventilation rate, but when the ventilation rate is more than 800 m3/h, the average CO2 concentration can be satisfied with the standard limits of Japanese in our case studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号