首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A 2 microm wavelength, 90 mJ, 5 Hz pulsed Ho laser is described with wavelength control to precisely tune and lock the wavelength at a desired offset up to 2.9 GHz from the center of a CO(2) absorption line. Once detuned from the line center the laser wavelength is actively locked to keep the wavelength within 1.9 MHz standard deviation about the setpoint. This wavelength control allows optimization of the optical depth for a differential absorption lidar (DIAL) measuring atmospheric CO(2) concentrations. The laser transmitter has been coupled with a coherent heterodyne receiver for measurements of CO(2) concentration using aerosol backscatter; wind and aerosols are also measured with the same lidar and provide useful additional information on atmospheric structure. Range-resolved CO(2) measurements were made with <2.4% standard deviation using 500 m range bins and 6.7 min? (1000 pulse pairs) integration time. Measurement of a horizontal column showed a precision of the CO(2) concentration to <0.7% standard deviation using a 30 min? (4500 pulse pairs) integration time, and comparison with a collocated in situ sensor showed the DIAL to measure the same trend of a diurnal variation and to detect shorter time scale CO(2) perturbations. For vertical column measurements the lidar was setup at the WLEF tall tower site in Wisconsin to provide meteorological profiles and to compare the DIAL measurements with the in situ sensors distributed on the tower up to 396 m height. Assuming the DIAL column measurement extending from 153 m altitude to 1353 m altitude should agree with the tower in situ sensor at 396 m altitude, there was a 7.9 ppm rms difference between the DIAL and the in situ sensor using a 30 min? rolling average on the DIAL measurement.  相似文献   

2.
The ratio of temporally adjacent lidar pulse returns is commonly used in differential absorption lidar (DIAL) to reduce correlated noise. These pulses typically are generated at different wavelengths with the assumption that the dominant noise is common to both. This is not the case when the mean number of laser speckle integrated per pulse by the lidar receiver is small (namely, less than 10 speckles at each wavelength). In this case a large increase in the standard deviation of the ratio data results. We demonstrate this effect both theoretically and experimentally. The theoretical value for the expected standard deviation of the pulse-pair ratio data compares well with the measured values that used a dual CO(2) laser-based lidar with a hard target. Pulse averaging statistics of the pulse-pair data obey the expected varsigma(1)/ radicalN reduction in the standard deviation, varsigma(N), for N-pulse averages. We consider the ratio before average, average before ratio, and log of the ratio before average methods for noise reduction in the lidar equation. The implications of our results are discussed in the context of dual-laser versus single-laser lidar configurations.  相似文献   

3.
A dual CO(2) laser-based differential absorption lidar (DIAL) system has been constructed and demonstrated for range-resolved mapping of chemical vapor plumes. The system acquires high range resolution through the use of plasma-shutter pulse clippers that extinguish the nitrogen tail of the CO(2)-laser output. Aprogrammable servomotor-driven scanner allows full hemispherical coverage of the interrogated field. A high-speed direct-detection receiver subsystem is used to gather, process, and display vapor-concentration data in near real time. Data demonstrating range-resolved detection of low concentrations of chemical plumes from ranges of 1 to 2 km are presented. In the column-content detection mode, trace levels of secondary vapors from various organophosphate liquids were monitored. Detection of an SF(6) vapor plume released 16 km from the DIAL system is also adduced.  相似文献   

4.
激光雷达探测大气中的CO2气体目前还处在探索阶段,在差分吸收原理基础上,利用气体的受激拉曼散射增益效应,设计出测量CO2气体的非线性拉曼激光雷达系统,并模拟实验得到了增益开关两种状态下的光子计数信号,从而反演出CO2气体的浓度分布结果,在垂直方向上,CO2气体浓度随距离变化不大,合肥地区的浓度含量大约在400ppm左右。  相似文献   

5.
An airborne differential absorption lidar (DIAL) system has been developed for the remote measurement of gas and aerosol profiles in the troposphere and lower stratosphere. The multipurpose DIAL system can operate from 280 to 1064 nm for measurements of ozone, sulfur dioxide, nitrogen dioxide, water vapor, temperature,pressure, and aerosol backscattering. The laser transmitter consists of two narrow linewidth Nd: YAG pumped dye lasers with automatic wavelength control. The DIAL wavelengths are transmitted with a 00-,usec temporal separation to reduce receiver system complexity. A coaxial receiver system is used to collect and optically separate the DIAL and aerosol lidar returns. Photomultiplier tubes detect the backscattered laser returns after optical filtering, and the analog signals from three tubes are digitized and stored on high-speed magnetic tape. Real-time gas concentration profiles or aerosol backscatter distributions are calculated and displayed for experiment control. Operational parameters for the airborne DIAL system are presented for measurements of ozone, water vapor, and aerosols in the 290-, 720-, and 600-nm wavelength regions, respectively. The first ozone profile measurements from an aircraft using the DIAL technique are discussed in this paper. Comparisons between DIAL and in situ ozone measurements show agreement to within +/-5 ppbv in the lower troposphere. Lidar aerosol data obtained simultaneously with DIAL ozone measurements are presented for a flight over Virginia and the Chesapeake Bay. DIAL system performance for profiling ozone in a tropopause folding experiment is evaluated, and the applications of the DIAL system to regional and global-scale tropospheric investigations are discussed.  相似文献   

6.
A CO2 differential-absorption lidar system has been used for the remote sensing of ammonia in the atmosphere. For CO2 lidar returns backscattered from topographic targets at ranges up to 2.7 km, the path-averaged sensitivity of the DIAL system was 5 ppb of NH3 . Concentrations of atmospheric ammonia were found to vary during the day from undetectable levels (<5 ppb) to as high as 20 ppb, depending on temperature and humidity conditions.  相似文献   

7.
An airborne differential absorption lidar (DIAL) system has been developed at the NASA Langley Research Center for remote measurements of atmospheric water vapor (H(2)O) and aerosols. A solid-state alexandrite laser with a 1-pm linewidth and > 99.85% spectral purity was used as the on-line transmitter. Solid-state avalanche photodiode detector technology has replaced photomultiplier tubes in the receiver system, providing an average increase by a factor of 1.5-2.5 in the signal-to-noise ratio of the H(2)O measurement. By incorporating advanced diagnostic and data-acquisition instrumentation into other subsystems, we achieved additional improvements in system operational reliability and measurement accuracy. Laboratory spectroscopic measurements of H(2)O absorption-line parameters were perfo med to reduce the uncertainties in our knowledge of the absorption cross sections. Line-center H(2)O absorption cross sections were determined, with errors of 3-6%, for more than 120 lines in the 720-nm region. Flight tests of the system were conducted during 1989-1991 on the NASA Wallops Flight Facility Electra aircraft, and extensive intercomparison measurements were performed with dew-point hygrometers and H(2)O radiosondes. The H(2)O distributions measured with the DIAL system differed by ≤ 10% from the profiles determined with the in situ probes in a variety of atmospheric conditions.  相似文献   

8.
Belmonte A 《Applied optics》2006,45(27):7097-7103
The presence of atmospheric refractive turbulence makes it necessary to use simulations of beam propagation to examine the uncertainty added to the differential absorption lidar (DIAL) measurement process of a practical heterodyne lidar. The inherent statistic uncertainty of coherent return fluctuations in ground lidar systems profiling the atmosphere along slant paths with large elevation angles translates into a lessening of accuracy and sensitivity of any practical DIAL measurement. This technique opens the door to consider realistic, nonuniform atmospheric conditions for any DIAL instrument configuration.  相似文献   

9.
A single-laser Raman differential absorption lidar (DIAL) for ozone measurements in clouds is proposed. An injection-locked XeCl excimer laser serves as the radiation source. The ozone molecule number density is calculated from the differential absorption of the anti-Stokes rotational Raman return signals from molecular nitrogen and oxygen as the on-resonance wavelength and the vibrational-rotational Raman backscattering from molecular nitrogen or oxygen as the off-resonance wavelength. Model calculations show that the main advantage of the new rotational vibrational-rotational (RVR) Raman DIAL over conventional Raman DIAL is a 70-85% reduction in the wavelength-dependent effects of cloud-particle scattering on the measured ozone concentration; furthermore the complexity of the apparatus is reduced substantially. We describe a RVR Raman DIAL setup that uses a narrow-band interference-filter polychromator as the lidar receiver. Single-laser ozone measurements in the troposphere and lower stratosphere are presented, and it is shown that on further improvement of the receiver performance, ozone measurements in clouds are attainable with the filter-polychromator approach.  相似文献   

10.
Vertical concentration profiles of atmospheric SO(2) of the order of parts in 10(9) (ppb) were measured by a multiwavelength differential absorption lidar system. The error that was due to O(3) and aerosols was successfully reduced by a three-wavelength dual differential absorption lidar (DIAL), and a SO(2) concentration of 1.2 ppb for 2400-3000-m altitude was obtained with 300-m range resolution. The measurement error in dual DIAL was estimated to be <1.1 ppb when several factors were considered. The influence of O(3) on SO(2) measurement error was experimentally evaluated from simultaneous measurements of atmospheric SO(2) and O(3) by two conventional DIAL pairs, each using two wavelengths.  相似文献   

11.
Harney RC 《Applied optics》1983,22(23):3747-3750
Laser pulse repetition frequency (prf) is a major factor in determining the performance of differential absorption lidar (DIAL) systems. The effects of laser prf on concentration measurement accuracy and maximum usable range are quantified. Heterodyne-detection (coherent) and direct-detection (noncoherent) as well as path-averaged and range-resolved DIAL systems are analyzed.  相似文献   

12.
A systematic analysis is presented of the extent to which the accuracy of a differential-absorption lidar (DIAL) measurement may be improved by using the combined effects of signal averaging and temporal cross correlation. Previous studies which considered these effects separately are extended by incorporating both effects into a single analytical framework. In addition, experimental results involving lidar returns from a diffusely reflecting target using a dual-CO2 laser DIAL system with both heterodyne and direct detection are presented. These results are shown to be in good agreement with the theoretical analysis and help establish the limits of accuracy achievable under various experimental conditions.  相似文献   

13.
Single and tandem Fabry-Perot etalons as solar background filters for lidar   总被引:1,自引:0,他引:1  
McKay JA 《Applied optics》1999,38(27):5851-5858
Atmospheric lidar is difficult in daylight because of sunlight scattered into the receiver field of view. In this research methods for the design and performance analysis of Fabry-Perot etalons as solar background filters are presented. The factor by which the signal to background ratio is enhanced is defined as a measure of the performance of the etalon as a filter. Equations for evaluating this parameter are presented for single-, double-, and triple-etalon filter systems. The role of reflective coupling between etalons is examined and shown to substantially reduce the contributions of the second and third etalons to the filter performance. Attenuators placed between the etalons can improve the filter performance, at modest cost to the signal transmittance. The principal parameter governing the performance of the etalon filters is the etalon defect finesse. Practical limitations on etalon plate smoothness and parallelism cause the defect finesse to be relatively low, especially in the ultraviolet, and this sets upper limits to the capability of tandem etalon filters to suppress the solar background at tolerable cost to the signal.  相似文献   

14.
Wulfmeyer V  Walther C 《Applied optics》2001,40(30):5304-5320
The performance of a future advanced water-vapor differential absorption lidar (DIAL) system is discussed. It is shown that the system has to be a direct-detection system operating in the rhovarsigmatau band of water vapor in the 940-nm wavelength region. The most important features of the DIAL technique are introduced: its clear-air measurement capability, its flexibility, and its simultaneous high resolution and accuracy. It is demonstrated that such a DIAL system can contribute to atmospheric sciences over a large range of scales and over a large variety of humidity conditions. An extended error analysis is performed, and errors (e.g., speckle noise) are included that previously were not been discussed in detail and that become important for certain system designs and measurement conditions. The applicability of the derived equation is investigated by comparisons with real data. Excellent agreement is found.  相似文献   

15.
The availability of new laser sources that are tunable in the IR spectral region opens new perspectives for differential absorption lidar (DIAL) measurements. A region of particular interest is located in the near IR, where some of the atmospheric pollutants have absorption lines that permit monitoring of emissions from industrial plants and in urban areas. In DIAL measurements, the absorption lines for the species to be measured must be carefully chosen to prevent interference from other molecules, to minimize the dependence of the absorption cross section on temperature, and to optimize the measurements with respect to the optical depth. We analyze the influence of these factors and discuss a set of criteria for selecting the best pairs of wavelengths (lambda(on) and lambda(off)) to be used in DIAL measurements of several molecular species (HCl, CO, CO(2), NO(2), CH(4), H(2)O, and O(2)). Moreover, a sensitivity study has been carried out for selected lines in three different regimes: clean air, urban polluted air, and emission from an incinerator stack.  相似文献   

16.
Irgang TD  Hays PB  Skinner WR 《Applied optics》2002,41(6):1145-1155
A direct-detection Doppler lidar system is demonstrated that uses a CCD as a detector for the first time to our knowledge. The ability to use this linear device with the circular output from a Fabry-Perot etalon comes from use of a circle-to-line converter [Appl. Opt. 29, 1482 (1990)]. In addition to the gains in quantum efficiency obtained through use of this detector, the lidar system described in this paper also has the capability to measure winds from aerosol and molecular backscatter simultaneously in two separate channels by directing the light reflected from one channel into the other. Early measurements with this system are presented; it is shown that, although accurate aerosol wind measurements are easily obtained, molecular measurements require a carefully calibrated inverse model and special hardware to derive accurate wind measurements with this channel.  相似文献   

17.
Hua D  Uchida M  Kobayashi T 《Applied optics》2005,44(7):1305-1314
A Rayleigh-Mie-scattering lidar system at an eye-safe 355-nm ultraviolet wavelength that is based on a high-spectral-resolution lidar technique is demonstrated for measuring the vertical temperature profile of the troposphere. Two Rayleigh signals, which determine the atmospheric temperature, are filtered with two Fabry-Perot etalon filters. The filters are located on the same side of the wings of the Rayleigh-scattering spectrum and are optically constructed with a dual-pass optical layout. This configuration achieves a high rejection rate for Mie scattering and reasonable transmission for Rayleigh scattering. The Mie signal is detected with a third Fabry-Perot etalon filter, which is centered at the laser frequency. The filter parameters were optimized by numerical calculation; the results showed a Mie rejection of approximately -45 dB, and Rayleigh transmittance greater than 1% could be achieved for the two Rayleigh channels. A Mie correction method is demonstrated that uses an independent measure of the aerosol scattering to correct the temperature measurements that have been influenced by the aerosols and clouds. Simulations and preliminary experiments have demonstrated that the performance of the dual-pass etalon and Mie correction method is highly effective in practical applications. Simulation results have shown that the temperature errors that are due to noise are less than 1 K up to a height of 4 km for daytime measurement for 300 W m(-2) sr(-1) microm(-1) sky brightness with a lidar system that uses 200 mJ of laser energy, a 3.5-min integration time, and a 25-cm telescope.  相似文献   

18.
A pulsed dual-wavelength dual-CO2-laser differential-absorption lidar (DIAL) system has been developed which permits simultaneous heterodyne and direct detection of the same lidar returns. This system has been used to make an experimental comparison of the SNRs and statistical and temporal characteristics of the DIAL returns from several topographic targets. These results were found to be in general agreement with theory and were used to quantify the relative merits of the two detection techniques. The measured parameter values were applied to an analytical treatment to predict system trade-offs for the remote sensing of atmospheric species, with application to both path-averaged and range-resolved measurements.  相似文献   

19.
Ridley KD  Pearson GN  Harris M 《Applied optics》2001,40(12):2017-2023
Remote detection of gaseous pollutants and other atmospheric constituents can be achieved with differential absorption lidar (DIAL) methods. The technique relies on the transmission of two or more laser wavelengths and exploits absorption features in the target gas by measuring the ratio of their detected powers to determine gas concentration. A common mode of operation is when the transmitter and receiver are collocated, and the absorption is measured over a return trip by a randomly scattering topographic target. Hence, in coherent DIAL, speckle fluctuation leads to a large uncertainty in the detected powers unless the signal is averaged over multiple correlation times, i.e., over many independent speckles. We examine a continuous-wave coherent DIAL system in which the laser wavelengths are transmitted and received by the same single-mode optical fibers. This ensures that the two wavelengths share a common spatial mode, which, for certain transmitter and target parameters, enables highly correlated speckle fluctuations to be readily achieved in practice. For a DIAL system, this gives the potential for improved accuracy in a given observation time. A theoretical analysis quantifies this benefit as a function of the degree of correlation between the two time series (which depends on wavelength separation and target depth). The results are compared with both a numerical simulation and a laboratory-based experiment.  相似文献   

20.
Modeling of direct detection Doppler wind lidar. I. The edge technique   总被引:2,自引:0,他引:2  
McKay JA 《Applied optics》1998,37(27):6480-6486
Analytic models, based on a convolution of a Fabry-Perot etalon transfer function with a Gaussian spectral source, are developed for the shot-noise-limited measurement precision of Doppler wind lidars based on the edge filter technique by use of either molecular or aerosol atmospheric backscatter. The Rayleigh backscatter formulation yields a map of theoretical sensitivity versus etalon parameters, permitting design optimization and showing that the optimal system will have a Doppler measurement uncertainty no better than approximately 2.4 times that of a perfect, lossless receiver. An extension of the models to include the effect of limited etalon aperture leads to a condition for the minimum aperture required to match light collection optics. It is shown that, depending on the choice of operating point, the etalon aperture finesse must be 4-15 to avoid degradation of measurement precision. A convenient, closed-form expression for the measurement precision is obtained for spectrally narrow backscatter and is shown to be useful for backscatter that is spectrally broad as well. The models are extended to include extrinsic noise, such as solar background or the Rayleigh background on an aerosol Doppler lidar. A comparison of the model predictions with experiment has not yet been possible, but a comparison with detailed instrument modeling by McGill and Spinhirne shows satisfactory agreement. The models derived here will be more conveniently implemented than McGill and Spinhirne's and more readily permit physical insights to the optimization and limitations of the double-edge technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号