在建筑物平移前需要对平移对象进行不同形式的加固.随着平移工程的日益复杂,对建筑加固也提出了新的要求.以厦门后溪长途汽车站平移工程为例,针对建筑平移前的整体加固措施和某些特定部位加固进行分析.详细介绍了整体加固、门厅前弧形钢结构加固、电梯加固中采取的具体施工技术措施.  相似文献   

2.
为了研究后植筋加固砌体棱柱体的受力性能,本文对6个未加固砌体棱柱体和6个采用后植筋加固的砌体棱柱体试件进行了受压试验,分析了后植筋加固砌体试件与未加固砌体试件的破坏形态、开裂荷载、极限承载力及变形能力.结果表明:后植筋砌体试件的开裂荷载、抗压强度较未加固砌体试件有所降低,但变形能力有一定程度提高.  相似文献   

3.
某现浇框架楼由于用途改变导致结构荷载增加,致使原框架柱、梁、板、基础承载力均不满足要求.根据结构安全性鉴定结果,选择加固方案,进行加固设计.最终采用了加大截面法进行结构整体加固处理.该建筑经过加固处理后,经检测验收,各项指标均可满足设计要求,加固效果良好.  相似文献   

4.
本文通过采用CFG桩加固软弱地基的工程实例,对该方法加固的设计、施工以及加固后的效果检验进行的论述.证明用该方法加固软弱地基技术的可行性,是值得推广应用的地基加固技术.  相似文献   

5.
讨论了钢筋锈蚀、混凝土强度、碳纤维布加固耐久性以及荷栽等影响因素变化对桥梁结构承栽力的影响.研究了加固后桥梁抗力计算方法,并结合实际桥梁工程进行了加固后可靠度计算.  相似文献   

6.
针对震损框架节点加固后的抗震性能,进行了5个空间框架节点加固试验.试验研究了灌缝、预损程度等因素对外包钢套法加固效果的影响.试验结果表明,外包钢套法在提高节点承载力、刚度及抗震性能等方面效果明显,节点破坏形式由加固前的“弱柱强梁”转变成加固后的“强柱弱梁”.试验表明加固后节点恢复并超过受损前的抗震性能,说明外包钢套法是合理而有效的.  相似文献   

7.
碳纤维加固设计中一些问题的探讨   总被引:1,自引:0,他引:1  
杨华  刘军 《建筑技术》2006,37(6):458-459
《碳纤维片材加固修复混凝土结构技术规程》颁布后,在结构加固设计中遇到碳纤维布加固量的控制、抗弯承载力加固后的提高幅度和工程简化计算的误差等问题,本文对上述问题进行探讨.  相似文献   

8.
本文分别采用抗震(桥墩补强)和隔震(更换隔震支座)两种不同的理念进行桥梁抗震加固.其中,影响桥梁加固后性能的影响因素主要包括桥墩的刚度参数和隔震支座的力学参数两个方面.通过有限元分析采用变参数控制的方法对加固后的桥梁进行抗震性能评价,得出不同加固方法中参数变化对桥梁抗震性能的影响.同时对加固后的桥梁进行经济性对比,主要考虑的经济影响因素包括:桥梁重要性、人员成本、施工难易程度、材料成本价格、材料运输费用、施工周期等.最后,采用量化的性能评价参数和工程经济学中常用的“功能/成本”概念,找到两种不同加固方法中“功能/成本”最优的加固点,从而制定出最优的抗震加固方案,并将论文中的研究成果运用到具体的工程实例当中,为今后我国桥梁抗震加固领域研究与应用提供参考和借鉴.  相似文献   

9.
该文主要介绍了采用通电加速钢筋锈蚀的方法对钢筋混凝土构件进行加速退化试验,并对退化后的构件进行碳纤维加固试验研究.通过时控制构件、退化后构件和加固后构件的力学性能对比,研究了钢筋混凝土构件力学性能退化情况和碳纤维加固效果,得到了可靠的结论.  相似文献   

10.
介绍了某结构楼层加固的工程实例,通过几种加固方案的比较,采用改变受力途径和其它方法相结合的加固方法进行处理,减少了加固工作量.并针对施工中节点的技术处理进行了探讨,提出了实用、可靠的施工方法,给出了一些具体的加固详图,加固完成后,投入使用多年,使用状况良好,可供类似工程加固设计参考.  相似文献   

11.
火灾后混凝土结构检测和加固技术研究   总被引:4,自引:4,他引:0  
钢筋混凝土结构在遭受火灾后,由于高温的影响,混凝土材料会发生化学变化,强度和延性降低,导致整个结构和构件的物理力学性能降低,产生损伤。通过对某住宅遭受火灾后工程检测和加固的实例,介绍火灾后钢筋混凝土结构的检测以及钢筋网复合砂浆加固受火灾结构的加固方案,重点探讨钢筋网复合砂浆加固该结构梁、板的施工工艺。工程实践证明,该方法加固效果明显,施工方便且节省投资。  相似文献   

12.
某双层网架由于建筑外形发生改变,需进行加固改造.鉴于网架焊接球无法加固,所以需改变受力模式,对杆件进行加固.经计算分析,对原有的网架杆件通过外包槽钢的做法来进行加固.该方法不仅可以满足安全度的要求,且施工便捷,加固效果良好.  相似文献   

13.
大型场馆异形钢结构屋面概念设计若干问题探讨   总被引:1,自引:0,他引:1       下载免费PDF全文
本文提出了大型场馆异形钢结构屋面的概念设计问题。对于周边墙体封闭的“馆”类建筑,屋面风的体型系数一般为负,即受风吸作用。对于“场”类建筑,则应根据屋盖各部分形状与风向的相对关系来确定屋面受风吸还是风压。对于异形屋面排水问题,屋面形状应尽可能满足快捷排水的要求。排水路径要短,水流要向结构的支座处会聚,尽量避免聚向悬挑端。评定一个结构是否是空间结构,看其在结构效应中,是以弯曲为主还是以轴向拉压为主。如果是前者,则结构的厚度和跨度之比就要求较大;而对于以拉压效应为主的空间结构,则其厚度和跨度之比可以较小。铸钢节点用于杆件交汇数量多、交角小的节点,可以避免较大的应力集中。但对于少量几根钢管之间的连接,不太适合使用铸钢节点,采用相贯线焊接,也同样能满足受力要求。  相似文献   

14.
The professional architect was a scarce commodity in early-nineteenth century America. Most buildings were built by skilled housewrights, members of trades, many of whom relied on pattern books. Because such a builder was legally obligated to perform “in a workmanlike manner,” i.e., to produce a structure free of defects, judges and juries believed that a builder architect should similarly guarantee his or her work. Growing private and corporate wealth created a demand for sophisticated design adequate to support a profession of architecture in America, and as professional education developed and professional associations were founded, the law began to recognize architects as professionals and to develop standards of care for architects similar to those applied to doctors and lawyers. The notion of the architect as guarantor of a defect-free building was rejected, and courts determined instead that the legal test of an architect's performance would be a test of professional judgment, not craft. To defend successfully against a claim of negligence, or to show an entitlement to collect a fee for services, the architect would have to prove not that he or she had designed a perfect building, but had acted with reasonable skill, knowledge and judgment equivalent to that generally exhibited by other members of the architectural profession.  相似文献   

15.
CCTV主楼SRC结构节点优化与施工   总被引:1,自引:1,他引:0  
CCTV主楼工程存在大量的劲性结构(SRC结构),需要从满足设计要求和现场可操作两方面进行SRC结构节点优化,并在钢结构深化设计和加工制作阶段进行相应节点连接件的定位、焊接等工作,以保证钢构件安装后混凝土构件的顺利施工。  相似文献   

16.
李翀  凡俊  张建勇 《工程质量》2014,32(9):66-69
很多混凝土结构在建设和使用过程中会出现不同程度、不同形式的裂缝,这是一个相当普遍的现象,而板、梁等受弯构件出现裂缝的情况更为突出。通过对裂缝出现的原因分析可知,大部分均为非受力裂缝。裂缝的出现对于构件的结构性能造成的影响程度是论文的主要研究内容。通过多个实验数据及对结果的分析,得出大部分裂缝对受弯构件的结构性能不会造成较大影响的实验结论。  相似文献   

17.
孙亚民 《钢结构》2012,(Z1):24-27
某冶炼项目的渣库,42m(长)x42m(宽)x10m(高)。业主方要求42m跨度内不能立柱;且几年后需要将结构整体搬迁到邻近二期场地,继续使用,要求结构易于拆装和运输;同时建设场地处在大面积新近填土区,需要结构能够较好地抵抗地基不均匀沉降。本文经过多种方案比较,最终采用三铰拱式平面桁架体系的方案,并经计算分析、经济性比较表明该体系能很好地满足使用要求并节约投资,满足安全、适用、经济的设计原则。  相似文献   

18.
在高层建筑对局部构件进行强度验算时,不应采用整体结构的风荷载计算公式.局部构件自身及其与主体结构连接处的风荷载内力效应,应为主体结构由于风荷载引起的振动,对于局部构件的支座动力输入,另加局部构件的直接风荷载.本文给出与规范相衔接的近似计算方法.  相似文献   

19.
夏大桥  陶亚东 《特种结构》2010,27(3):54-55,63
在钢塔结构中,塔柱是主要的受力构件,其稳定性直接关系到结构整体的安全,在工程设计中不容忽视。对于节点连接复杂的塔体结构,由于考虑到其他相连杆件的约束作用,一般不能简单将塔柱两端视为铰接,此时钢塔柱的计算长度在现行设计规范中没有明确说明,不能简单按照规范方法进行设计。为此,本文以江苏太仓市电视塔工程为例,选取其代表性结构单元,通过线性和非线性屈曲分析方法对钢塔柱在整体结构中的稳定性进行了计算。通过本文的研究,给出了塔柱的计算长度系数的估算方法,并针对太仓塔工程给出了合理的塔柱计算长度系数值。  相似文献   

20.
熊雄  周雷靖  曹洋 《特种结构》2011,28(2):40-43
采用分离式环梁提升烟囱钢内筒时,钢内筒受力状态不同于其使用时,因而对钢内筒需要加固,同时还要保证吊装各构件的安全,但相关验算在规范和手册中均没有参考。本文利用ABAQUS有限元软件对这一吊装过程进行有限元模拟,分析了钢内筒、倒牛腿、环梁和下锚固垫板等主要构件的受力和变形特征,并与附壁式环梁模型进行了对比。分析表明,各构件应力较小,吊装过程安全可靠,多数构件具有较大的优化潜力。重力荷载在环梁上分布不均匀。当分离式环梁整体刚度相对于钢内筒大的多时,采用节点耦合的简化计算模型对结果影响并不大。分析结论对设计起到了一定的指导作用,实际吊装过程也证实了本分析的正确性。  相似文献   