首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Radiation protection dosimetry in radiation fields behind the shielding of high-energy accelerators such as CERN is a challenging task and the quantitative understanding of the detector response used for dosimetry is essential. Measurements with ionisation chambers are a standard method to determine absorbed dose (in the detector material). For applications in mixed radiation fields, ionisation chambers are often also calibrated in terms of ambient dose equivalent at conventional reference radiation fields. The response of a given ionisation chamber to the various particle types of a complex high-energy radiation field in terms of ambient dose equivalent depends of course on the materials used for the construction and the chamber gas used. This paper will present results of computational studies simulating the exposure of high-pressure ionisation chambers filled with different types of gases to the radiation field at CERN's CERN-EU high-energy reference field facility. At this facility complex high-energy radiation fields, similar to those produced by cosmic rays at flight altitudes, are produced. The particle fluence and spectra calculated with FLUKA Monte Carlo simulations have been benchmarked in several measurements. The results can be used to optimise the response of ionisation chambers for the measurement of ambient dose equivalent in high-energy mixed radiation fields.  相似文献   

2.
The monitoring of ambient doses at work places around high-energy accelerators is a challenging task due the complexity of the mixed stray radiation fields encountered. At CERN, mainly Centronics IG5 high-pressure ionisation chambers are used to monitor radiation exposure in mixed fields. The monitors are calibrated in the operational quantity ambient dose equivalent H*(10) using standard, source-generated photon- and neutron fields. However, the relationship between ionisation chamber reading and ambient dose equivalent in a mixed high-energy radiation field can only be assessed if the spectral response to every component and the field composition is known. Therefore, comprehensive studies were performed at the CERN-EU high-energy reference field facility where the spectral fluence for each particle type has been assessed with Monte Carlo simulations. Moreover, studies have been performed in an accessible controlled radiation area in the vicinity of a beam loss point of CERN's proton synchrotron. The comparison of measurements and calculations has shown reasonable agreement for most exposure conditions. The results indicate that conventionally calibrated ionisation chambers can give satisfactory response in terms of ambient dose equivalent in stray radiation fields at high-energy accelerators in many cases. These studies are one step towards establishing a method of 'field calibration' of radiation protection instruments in which Monte Carlo simulations will be used to establish a correct correlation between the response of specific detectors to a given high-energy radiation field.  相似文献   

3.
For an accurate determination of the absorbed doses in complex radiation fields (e.g. mixed neutron-gamma fields), a better interpretation of the response of ionisation chambers is required. This study investigates a model of the ionisation chambers using a different approach, analysing the collected charge per minute as a response of the detector instead of the dose. The MCNPX Monte Carlo code is used. In this paper, the model is validated using a well-known irradiation field only: a (60)Co source. The detailed MCNPX models of a Mg(Ar) and TE(TE) ionisation chamber is investigated comparing the measured charge per minute obtained free-in-air and in a water phantom with the simulated results. The difference between the calculations and the measurements for the TE(TE) chamber is within +/-2% whereas for the Mg(Ar) chamber is around +7%. The systematic discrepancy in the case of Mg(Ar) chamber is expected to be caused by an overestimation of the sensitive volume.  相似文献   

4.
Monitoring of the radiation environment is one of the key tasks in operating a high-energy accelerator such as the Large Hadron Collider (LHC). The radiation fields consist of neutrons, charged hadrons as well as photons and electrons with energy spectra extending from those of thermal neutrons up to several hundreds of GeV. The requirements for measuring the dose equivalent in such a field are different from standard uses and it is thus necessary to investigate the response of monitoring devices thoroughly before the implementation of a monitoring system can be conducted. For the LHC, it is currently foreseen to install argon- and hydrogen-filled high-pressure ionisation chambers as radiation monitors of mixed fields. So far their response to these fields was poorly understood and, therefore, further investigation was necessary to prove that they can serve their function well enough. In this study, ionisation chambers of type IG5 (Centronic Ltd) were characterised by simulating their response functions by means of detailed FLUKA calculations as well as by calibration measurements for photons and neutrons at fixed energies. The latter results were used to obtain a better understanding and validation of the FLUKA simulations. Tests were also conducted at the CERF facility at CERN in order to compare the results with simulations of the response in a mixed radiation field. It is demonstrated that these detectors can be characterised sufficiently enough to serve their function as radiation monitors for the LHC.  相似文献   

5.
Alanine and Radio-Photo-Luminescence (RPL) dosemeters are passive dosemeters used to monitor absorbed dose in all kind of radiation fields. However, up to now both dosemeter types are calibrated to photon sources only. In order to study the response of RPL and alanine dosemeters to mixed high-energy particle fields like those occurring at CERN's accelerators, an irradiation campaign at the CERN-EC High-Energy Reference field Facility (CERF-field) was performed. In this facility a copper target is irradiated by hadrons with a momentum of 120 GeV/c. Dosemeters were exposed to various mixed radiation fields by placing them at various positions on the surface of the target. In addition to the experiment FLUKA Monte Carlo simulations were carried out, which provide information concerning the energy deposition at the dosemeter locations. This paper compares the measurements with the simulation results and discusses the radiation field compositions present at the various dosemeter positions on the target.  相似文献   

6.
Radiation protection around CERN's high-energy accelerators represents a major challenge due to the presence of complex, mixed radiation fields. Behind thick shielding neutrons dominate and their energy ranges from fractions of eV to about 1 GeV. In this work the response of various portable detectors sensitive to neutrons was studied at CERN's High-Energy Reference Field Facility (CERF). The measurements were carried out with conventional rem counters, which usually cover neutron energies up to 20 MeV, the Thermo WENDI-2, which is specified to measure neutrons up to several GeV, and a tissue-equivalent proportional counter. The experimentally determined neutron dose equivalent results were compared with Monte Carlo (MC) simulations. Based on these studies field calibration factors can be determined, which result in a more reliable estimate of H(*)(10) in an unknown, but presumably similar high-energy field around an accelerator than a calibration factor determined in a radiation field of a reference neutron source.  相似文献   

7.
The purpose of this work was to develop a method for estimating the patient peak entrance surface air kerma from measurements using a pencil ionisation chamber on dosimetry phantoms exposed in a computed tomography (CT) scanner. The method described is especially relevant for CT fluoroscopy and CT perfusion procedures where the peak entrance surface air kerma is the risk-related quantity of primary concern. Pencil ionisation chamber measurements include scattered radiation, which is outside the primary radiation field, and that must be subtracted in order to derive the peak entrance surface air kerma. A Monte Carlo computer model has therefore been used to calculate correction factors, which may be applied to measurements of the CT dose index obtained using a pencil ionisation chamber in order to estimate the peak entrance surface air kerma. The calculations were made for beam widths of 5, 7, 10 and 20 mm, for seven positions of the phantom, and for the geometry of a GE HiSpeed CT/i scanner. The program was validated by comparing measurements and calculations of CTDI for various vertical positions of the phantom and by directly estimating the peak ESAK using the program. Both validations showed agreement within statistical uncertainties (standard deviation of 2.3% or less). For the GE machine, the correction factors vary by approximately 10% with slice width for a fixed phantom position, being largest for the 20 mm beam width, and at that beam width range from 0.87 when the phantom surface is at the isocentre to 1.23 when it is displaced vertically by 24 cm.  相似文献   

8.
A new method is proposed for the determination of dose components in mixed radiation fields (gamma + neutrons) using a recombination chamber. The method involves the determination of the ratio of ionisation currents measured at two different voltages applied to the chamber without the need of determining the saturation current, neither in the radiation field investigated nor during calibration. Therefore, the chamber can be filled with a gas under a pressure much higher than that used in presently available recombination chambers. This paper presents theoretically derived formulae supporting the method and the experimental results of dose component measurements using a high-pressure recombination chamber filled with methane. The method can be used for determining neutron and gamma dose components in the environment, especially in the vicinity of nuclear centres.  相似文献   

9.
Free-air ionisation chambers are widely used at standards laboratories as primary standards for absolute measurements of air kerma in X-ray fields. The area of the diaphragm aperture of a free-air ionisation chambers is an important factor for absolute measurements because it defines the size of the X-ray beam incident on the free-air chamber. In this study, correction factors for the contribution of X rays transmitted through the diaphragm of a free-air ionisation chamber and those scattered from the surface of the diaphragm aperture are obtained by Monte Carlo simulation for two different sized free-air ionisation chambers and for various diaphragm aperture sizes, X-ray energies and source-to-chamber distances.  相似文献   

10.
Absorbed dose rate measurements of a 50 kV(p) handheld X-ray probe source in a water phantom are described. The X-ray generator is capable of currents of up to 40 microA, and is designed for cranial brachytherapy and intraoperative applications with applicators. The measurements were performed in a computer-controlled water phantom in which both the source and the detectors are mounted. Two different LiF thermoluminescence dosemeter (TLD) phosphors were employed for the measurements, MTS-N (LiF:Mg,Ti) and MCP-N (LiF:Mg,Cu,P). Two small ionisation chambers (0.02 and 0.0053 cm(3)) were also employed. The TLDs and chambers were positioned in watertight mounts made of water-equivalent plastic. The chambers were calibrated in terms of air-kerma rate, and conventional protocols were used to convert the measurements to absorbed dose rate. The TLDs were calibrated at National Institute of Standards and Technology (NIST) in terms of absorbed dose rate using a (60)Co teletherapy beam and narrow-spectrum X-ray beams. For the latter, absorbed dose was inferred from air-kerma rate using calculated air-kerma-to-dose conversion factors. The reference points of the various detectors were taken as the center of the TLD volumes and the entrance windows of the ionisation chambers. Measurements were made at distances of 3-45 mm from the detector reference point to the source center. In addition, energy dependence of response measurements of the TLDs used was made using NIST reference narrow spectrum X-ray beams. Measurement results showed reasonable agreement in absorbed dose rate determined from the energy dependence corrected TLD readings and from the ionisation chambers. Volume averaging effects of the TLDs at very close distances to the source were also evident.  相似文献   

11.
To investigate and monitor environmental radiation at ground level, Physikalisch-Technische Bundesanstalt (PTB) has installed several dosemeters and particle detectors at the new Ambient Radiation Dosimetry Site. The separation of the total ambient dose equivalent rate H*10(env) of environmental radiation into the different contributions is achieved by comparing the data of different detectors: the muon detector MUDOS, a modified neutron dosemeter, proportional counters and ionisation chambers. The response of the latter two dosemeter systems to cosmic radiation was determined at the Cosmic Radiation Dosimetry Site on a lake near PTB. Besides the increase of the ambient dose equivalent rate during rainfall, variations owing to air pressure, solar activity and temperature changes in the upper atmosphere are observed. Without rain and solar effects, smooth variations of the cosmic component at ground level of +/-6.9 nSv h(-1) should be treated as naturally occurring variations during an entire year.  相似文献   

12.
This work investigates the relevance of several factors affecting the response of silicon diode dosemeters in depth-dose scans of electron beams. These factors are electron energy, instantaneous dose rate, dose per pulse, photon/electron dose ratio and electron scattering angle (directional response). Data from the literature and our own experiments indicate that the impact of these factors may be up to +/-15%. Thus, the different factors would have to cancel out perfectly at all depths in order to produce true depth-dose curves. There are reports of good agreement between depth-doses measured with diodes and ionisation chambers. However, our measurements with a Scantronix electron field detector (EFD) diode and with a plane-parallel ionisation chamber show discrepancies both in the build-up and in the low-dose regions, with a ratio up to 1.4. Moreover, the absolute sensitivity of two diodes of the same EFD model was found to differ by a factor of 3, and this ratio was not constant but changed with depth between 5 and 15% in the low-dose regions of some clinical electron beams. Owing to these inhomogeneities among diodes even of the same model, corrections for each factor would have to be diode-specific and beam-specific. All these corrections would have to be determined using parallel plane chambers, as recommended by AAPM TG-25, which would be unrealistic in clinical practice. Our conclusion is that in general diodes are not reliable in the measurement of depth-dose curves of clinical electron beams.  相似文献   

13.
A combination of the recombination principle of H(10) measurements with the use of the ionisation chambers containing boron has been presented, in order to increase the relative sensitivity of the chamber to neutrons by a factor close to the radiation quality factor of photoneutrons. Three types of the chambers were investigated. Two of them were filled with BF(3) and the third one contained electrodes covered with B(4)C. All the chambers were placed in paraffin moderators. The response of the chambers was investigated, depending on gas pressure and polarising voltage. The results showed that it was possible to obtain nearly the same response of the chamber to H(10) for photons and neutrons in a restricted energy range; however, further investigations are needed to make an optimum design.  相似文献   

14.
New generation of radiation therapy accelerators requires highly accurate dose measurements with high spatial resolution patterns. IMRT is especially demanding since the positioning accuracy of all the multi-leafs should be verified for each applied field and at any incidence. A new 2-D tissue equivalent dosemeter is presented with high spatial resolution that can fulfil these tasks. A plastic scintillator sheet is sandwiched between two polystyrene cubes, and the emitted light is observed by a high-resolution camera. A patented procedure allows efficient discrimination of the scintillation proportional to the dose from the parasitic Cerenkov radiation. This extraction made on the cumulated images taken during an irradiation field at a rate of 10 images s(-1) provides high-resolution mapping of the dose rate and cumulated dose in quasi real time. The dosemeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment, since phantom and detector materials are identical. The calibration is simple and independent of the irradiation conditions (energy, fluence, quality and so on). The principle of the dosemeter and its calibration procedure are discussed in this paper. The results and, in particular, the dose depth profiles are compared with standard ionisation chamber measurements in polystyrene for both photons and electrons. Finally, the detector specifications are summarised and one example of complex IMRT field is discussed.  相似文献   

15.
A set of cylindrical recombination chambers, including a tissue-equivalent chamber and three graphite chambers filled with different gases-CO(2), N(2) and (10)BF(3), was designed for the dosimetry of therapeutic neutron radiation beams used for BNCT. The separation of the dose components is based on differences of the shape of the saturation curve depending on the LET spectrum of the investigated radiation. The measurements using all the chambers were performed in a reactor beam of NRI ReZ (Czech Republic) and in the reference radiation fields of a (252)Cf radiation source free in air or in filters.  相似文献   

16.
The dependence of the doses on solar activity for intermediate levels of the solar modulation parameter has been studied by means of simulations carried out by the Monte Carlo transport code FLUKA. The vertical cut-off rigidities investigated lie between 0.4 and 6.1 GV. The calculated results show that the linear dependence proposed in a previous work, for the effective dose rate as a function of the solar modulation parameter, can be considered as an acceptable approximation. In addition, some dosimetric characteristics of cosmic radiation and some properties of the dosemeters in use for monitoring in the cosmic ray environment have been analysed with a view to simplifying measurements. The depth-dose curves in the ICRU sphere and the response of a tissue-equivalent ionisation chamber have been determined by the FLUKA code for a number of cosmic ray spectra On the basis of the calculated results, it is concluded that a value of the depth. d, which would make the ambient dose equivalent a conservative predictor of the effective dose, cannot be specified for cosmic radiation. However, the operational quantity can be useful in order to verify the predictions of Monte Carlo calculations. It is demonstrated that a crude approximation of the ambient dose equivalent could be obtained by multiplying by 2 the absorbed dose measured by a tissue-equivalent ionisation chamber with wall thickness of 10 mm.  相似文献   

17.
Neutron therapy beams are obtained by accelerating protons or deuterons on Beryllium. These neutron therapy beams present comparable dosimetric characteristics as those for photon beams obtained with linear accelerators; for instance, the penetration of a p(65)+Be neutron beam is comparable with the penetration of an 8 MV photon beam. In order to be competitive with conventional photon beam therapy, the dosimetric characteristics of the neutron beam should therefore not deviate too much from the photon beam characteristics. This paper presents a brief summary of the neutron beams used in radiotherapy. The dosimetry of the clinical neutron beams is described. Finally, recent and future developments in the field of physics for neutron therapy is mentioned. In the last two decades, a considerable number of centres have established radiotherapy treatment facilities using proton beams with energies between 50 and 250 MeV. Clinical applications require a relatively uniform dose to be delivered to the volume to be treated, and for this purpose the proton beam has to be spread out, both laterally and in depth. The technique is called 'beam modulation' and creates a region of high dose uniformity referred to as the 'spread-out Bragg peak'. Meanwhile, reference dosimetry in these beams had to catch up with photon and electron beams for which a much longer tradition of dosimetry exists. Proton beam dosimetry can be performed using different types of dosemeters, such as calorimeters, Faraday cups, track detectors and ionisation chambers. National standard dosimetry laboratories will, however, not provide a standard for the dosimetry of proton beams. To achieve uniformity on an international level, the use of an ionisation chamber should be considered. This paper reviews and summarises the basic principles and recommendations for the absorbed dose determination in a proton beam, utilising ionisation chambers calibrated in terms of absorbed dose to water. These recommendations are based on the recent IAEA TRS398 Code of Practice: 'Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water'.  相似文献   

18.
The RIKEN RI (radioactive isotope) Beam Factory is scheduled to commence operations in 2006, and its maximum energy will be 400 MeV u(-1) for ions lighter than Ar and 350 MeV u(-1) for uranium. The beam intensity will be 1 pmicroA (6 x 10(12) particles s(-1)) for any element at the goal. For the hands-on-maintenance and the rational shield thickness of the building, the beam loss must be controlled with several kinds of monitors. Three types of radiation monitors will be installed. The first one consists of a neutron dose equivalent monitor and an ionisation chamber, which are commercially available area monitors. The second one is a conventional hand-held dose equivalent monitor wherein the logarithmic signal is read by a programmable logic controller based on the radiation safety interlock system (HIS). The third one is a simple plastic scintillator called a beam loss monitor. All the monitors have threshold levels for alarm and beam stop, and HIS reads all these signals.  相似文献   

19.
A signal current from a cylindrical ionisation chamber with an ionisation volume of 62.7 cm3, 40 mm in diameter and 50 mm long, peaked when the chamber was lixed at 0 degrees and at 90 degrees in 137Cs and 60Co gamma ray fields for source-chamber distances of 1 m and 2 m. A smaller ionisation chamber showed a small peak at 0 degrees in both fields but not at 90 degrees. However, calculations indicated that the signal current from the smaller chamber would also show a peak at 90 degrees in a 137Cs point-source gamma ray field. Peaks occur because gamma rays attenuate along the cylindrical side wall or along the end walls when a chamber is tilted slightly from 0 degrees or 90 degrees and the direction of the gamma ray beam agrees with the plane of one of these walls. These facts suggest the need for care in the common practice of measuring and calculating responses for cylindrical ionisation chambers fixed perpendicular to gamma ray beams.  相似文献   

20.
A Monte Carlo code MCNPX (Monte Carlo N-particle) was used to model a 25 MV photon beam from a PRIMUS (KD2-Siemens) medical linear electron accelerator at the Centre Antoine Lacassagne in Nice. The entire geometry including the accelerator head and the water phantom was simulated to calculate the dose profile and the relative depth-dose distribution. The measurements were done using an ionisation chamber in water for different square field ranges. The first results show that the mean electron beam energy is not 19 MeV as mentioned by Siemens. The adjustment between the Monte Carlo calculated and measured data is obtained when the mean electron beam energy is approximately 15 MeV. These encouraging results will permit to check calculation data given by the treatment planning system, especially for small fields in high gradient heterogeneous zones, typical for intensity modulated radiation therapy technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号