首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We extend the equations for the dimensionless collision kernel and filtration efficiency, attained previously via mean first-passage time (MFPT) calculations, to particles of arbitrary shape. Specifically, we show that the regression equations for the dimensionless collision rate found considering particle-fiber collisions driven by simultaneous diffusion and interception remain valid for non-spherical particles, provided that an appropriate collision length scale for the non-spherical particle (L) is defined and incorporated into the definitions of the dimensionless collision rate (H) and the diffusive Knudsen number (KnD). Regression equations are provided to calculate this length scale for quasifractal aggregates of varying fractal dimension, as well as cylinders. MFPT calculations reveal that, over ~5 orders of magnitude in H, these regression equations for the collision length are valid. Furthermore, using the previously attained proportionality between the predicted dimensionless collision rate and the single-fiber efficiency, comparison is made between the equations presented here and measurements of the penetration of both multiwalled carbon nanotubes and quasifractal aggregates through fibrous filters. Reasonable agreement is found between measured and predicted single-fiber efficiencies in both circumstances, supporting the use of the single-fiber efficiency calculation approach we developed.

Copyright 2014 American Association for Aerosol Research  相似文献   


2.
It is currently admitted that for each filtration process using pleated filters, at least three steps can be distinguished: depth and surface filtration, which are common to flat filters, and surface reduction. This step is caused by inefficient filling of the pleat due to the filter geometry. For combustion aerosol, it has been proved that this third step strongly depends on the filtration velocity resulting in an increase of the resistance when air flow decreases. This observation leads one to think that Brownian diffusion, higher for low velocities, could influence the clogging dynamic of a pleated filter.

In this article, a protocol derived from the dust cake preparation method published by Schmidt is developed. The aim of this study is to measure the aerosol penetration inside a filter media as well as in a pleat using a scanning electronic microscope and energy dispersive X-ray spectroscopy elementary detection. This method has also been extended to the study of pleated filters to measure the particle distribution inside the pleat. Filters were loaded with nanoparticles in order to evaluate the specificity of the diffusional regime on the clogging of pleated HEPA filters. For pleated filters, two filtration velocities were investigated: 2.5 and 0.2 cm/s.

Copyright 2014 American Association for Aerosol Research  相似文献   


3.
Near traffic routes and urban areas, the outdoor air particle number concentration is typically dominated by ultrafine particles. These particles can enter into the nearby buildings affecting the human exposure on ultrafine particles indoors. In this study, we demonstrate an aerosol generation system which mimics the characteristic traffic related aerosol. The aerosol generation system was used to determine the size-resolved particle filtration efficiencies of five typical commercial filters in the particle diameter range of 1.3–240 nm. Two different HEPA filters were observed to be efficient in all particle sizes. A fibrous filter (F7) was efficient at small particle sizes representing the nucleation mode of traffic related aerosol, but its efficiency decreased down to 60% with the increasing particle size. In contrast, the filtration efficiency of an electrostatic precipitator (ESP) increased as a function of the particle size, being more efficient for the soot mode of traffic related aerosol than for the nucleation mode. An electret filter with a charger was relatively efficient (filtration efficiency >85%) at all the observed particle sizes. The HEPA, F7 and electret filters were found to practically remove the particles/nanoclusters smaller than 3 nm. All in all, the filtration efficiencies were observed to be strongly dependent on the particle size and significant differences were found between different filters. Based on these results, we suggest that the particulate filter test standards should be extended to cover the ultrafine particles, which dominate the particle concentrations in outdoor air and are hazardous for public health.

Copyright © 2017 American Association for Aerosol Research  相似文献   


4.
The Institute of Radioprotection and Nuclear Safety (IRSN in French) is conducting research on the impact of a fire on the behaviour of containment devices such as high efficiency particulate air (HEPA) pleated filters for radioactive materials. This work aims to study the clogging of HEPA filters in case of fire involving realistic materials (polymers making up gloves boxes, waste treatment solvent, hydraulic oil, solid material mixtures making up a trash bin, electrical cables, and cabinets) used in nuclear facilities, from the medium to large scale. The clogging kinetics of industrial pleated HEPA filters is monitored by measuring the pressure drop of the filters and the filtered air temperature at a given filtration velocity (from 0.23 to 2.1 cm/s). Upstream HEPA filters, combustion aerosols are characterized in terms of size distribution, mass concentration, composition, and particle morphology using, respectively, a DMS500 (CambustionLTD), glass fiber filter sampling, and transmission electron microscope analysis of particles deposited on TEM grids. Particles emitted denote well-known fractal morphology, are composed of carbonaceous primary particles with diameters ranging from 31 nm to 48 nm and showing an high clogging efficiency. An empirical relationship has been successfully applied to the obtained results for a larger range of fuels, filtration velocities and fire conditions.

Finally, experiments have been performed on a large-scale facility, using full-scale fire scenarios (electrical cabinet, constant, and variable filtration velocity) and a reasonable agreement was observed with our empirical relationship. At this scale, particles appear to be compact, with a complex composition and diameters close to 220 nm with a lower clogging efficiency.

Copyright 2014 American Association for Aerosol Research  相似文献   


5.
The net acoustic force acting on submicron particles suspended in a gas and exposed to a standing wave field is investigated as a function of particle size, by measuring both the aerosol number density and size distribution in a flow-through resonator. By taking into account all contributions relevant to the net force, this experimental study provides a first estimate for the acoustic radiation force in a size range where molecular effects are expected to be significant. The experiment consists of an electrostatic transducer generating a standing wave in the 50–80 kHz frequency range, with the submicron aerosol particles concentrated at pressure antinodes located across the height of a rectangular channel. A section of the flow is sampled isokinetically and analyzed using a Scanning Mobility Particle Sizer (SMPS), while the nodal patterns are visualized simultaneously using light scattering. The net acoustic force is calculated from their measured displacement along the axis of the 1D standing wave field. The component of this force resulting from radiation pressure is estimated by subtracting contributions from other forces. The results provide the first experimental estimation of the size dependence of the acoustic contrast factor for submicron aerosol particles, demonstrating the possibility of performing acoustic separation for diameters as small as 150 nm.

Copyright © 2018 American Association for Aerosol Research  相似文献   


6.
Fibrous filters are commonly used for aerosol purification and sampling. The filtration efficiency has been extensively studied using standard aerosol generators, yet the literature on experimental data and theoretical study concerning the filtration of agglomerates from real engines remains scarce. A filtration efficiency test system was developed to determine the filtration efficiency of two types of filters (uncoated and fluorocarbon coated) loaded by particulate matter (PM) emissions from a gasoline direct injection (GDI) engine. The experimental results showed that the filtration efficiency in terms of PM mass and number increased over time for both types of filters. The fractional efficiency (penetration efficiency) curves for the test fibrous filters rendered a U-shaped curve for particle sizes from 70 to 500 nm, and the most penetrating particulate size (MPPS) decreased over time. A small fraction of accumulation mode particles with the size between 70 nm to 500 nm penetrated the filters while almost all nucleation mode particles with the size below 50 nm were captured by the filters. The filtration efficiency derived from an empirical model based on classical single-fiber theory for laden filters generally agreed with the experimental data for the first 500 s, but suffered a significant deviation by approximately one order of magnitude at 948 s. A better estimate of the filtration efficiency trend with the maximum deviation of about 20% (except for large particles at the high end of the measurement spectra) was obtained by using a revised model which incorporates the effects of the increase in filter solidity, local velocity, dynamic shape factor and effective total length of fibers during the filtration process.

© 2017 American Association for Aerosol Research  相似文献   


7.
The effect of image force on the penetration of nanometer particles through metal grids remains a controversial issue. Experimental evidence of the existence and of the absence of such effect have both been reported in the past. A careful experimental work to measure penetration of particles in the mobility equivalent diameter range between 3.4 and 10 nm has been carried out. The possible particle size change between the aerosol generator and the filter has been considered, as well as the possible effect of particle number concentration on the filtration efficiency. The geometric dimensions of the filter allowed attainment of the fully developed parabolic flow velocity profile upstream the grid. Measurements were done at two values of the fiber Reynolds number, 0.09 and 0.12, much smaller than 1, as demanded by the currently accepted filtration theory. Penetration of charged particles, measured in three alternative ways, has been compared with penetration of uncharged and neutral particles (the latter consisting of a mixture of positive, negative, and uncharged particles). Two main conclusions have been reached: (1) the charging state of the particles does not affect their penetration through the metal grid and (2) the experimentally measured penetrations are fairly well predicted by the fan filter model of Cheng and Yeh.

Copyright © 2018 American Association for Aerosol Research  相似文献   


8.
An external electric field was applied on the filter to improve its collection efficiency, and the collection efficiencies of the different filters under various conditions were evaluated. Dominant electrical filtration mechanisms for each condition were investigated using experimental and theoretical approaches. Four types of air filters were used as test filters: a charged fiber filter, a low-grade filter with 50% collection efficiency in the most penetration particle size (MPPS) zone, and two high-grade filters with more than 95% collection efficiency in the MPPS zone. Three different particle charge states—neutralized, single-charged and uncharged—were considered. For neutralized particles, the external electric field led to a 14.5%p. and 2.5%p. increase in the collection efficiencies of the low-grade filter and charged fiber filter, respectively. With the electric field, the collection efficiency of the low-grade filter increased by 30%p. for single-charged particles. The electric field also affected the collection efficiencies of the charged filter and high-grade filters, but the effect was not significant. For uncharged particles, the electric field did not lead to a remarkable increase in the collection efficiencies of any of the filters. Through experimental and theoretical analysis, it was found that the polarization force imposed on the charged fiber was the dominant factor for the charged fiber filter regardless of application of the external electric field. The Coulombic force imposed on the electric field was the dominant factor for the low-grade filter, while both the Coulombic and the polarization forces affected the collection efficiency of the high-grade filter.

Copyright © 2017 American Association for Aerosol Research  相似文献   


9.
Many well-established models can be applied to calculate the filtration efficiencies. In these models the filtration velocity and challenging particle size are assumed to be known accurately. However, in realistic filtration tests, the filtration velocity has profiles dependent on the filter holder geometry and experimental conditions; the challenging particles have size distributions dependent on the instruments and operation conditions. These factors can potentially affect the measured filtration efficiency and lead to discrepancies with the models.

This study aims to develop an integrative model to predict the filtration efficiencies in realistic tests by incorporating the effects of the filtration velocity profile and challenging particle size distribution classified by a differential mobility analyzer (DMA) into the existing filtration models. Face velocity profile is modeled with fluid mechanics simulations; the initial generated particle size distribution, the particle charging status and the DMA transfer function are modeled to obtain the challenging particle size distribution. These results are then fed into the filtration models. Simulated results are compared with experimental ones to verify the model accuracy. This model can be used to reduce filtration test artifacts and to improve the experimental procedure.

The results reveal that the face velocity upstream the filter exhibits high degree of homogeneity not affecting the filtration efficiency if the filter pressure drop is not very low. The generated particle size distribution and the DMA selection size window could influence the challenging particle size distribution and therefore the measured filtration efficiency.

Copyright © 2017 American Association for Aerosol Research  相似文献   


10.
Particulate gas filters are a critical element in the purification systems used to ensure defect-free manufacturing in semiconductor industry. In atomic layer deposition (ALD) processes, these filters are typically operated under sub-atmospheric pressure conditions, but their filtration characteristics are, often, only known at atmospheric pressure. In this study, performance of a metal filter that is typically used in low-pressure ALD precursor delivery systems is studied experimentally and theoretically down to 4.5 kPa. The experimental procedure was designed to minimize the presence of multiply charged particles in the test aerosol for different operating pressures and flowrates. The experimental results suggest that most penetrating particle size only slightly varies with pressure, but the shape of the penetration curve and the maximum value of the penetration changes significantly with pressure. The experimental data are used to test predictions of filter performance at low pressures made using classical theory. The comparison results suggest that the combination of classical theory and manufacturer-specified parameters results in large errors in calculated penetration values at low pressures. Accurate predictions are seen to be possible for particle Stokes numbers less than 0.1, when an inhomogenous filtration model is used in combination with effective filter parameters that are obtained from experimental measurements of filter efficiency and pressure drop at atmospheric pressures.

Copyright © 2016 American Association for Aerosol Research  相似文献   


11.
The purpose of this study was to compare the performance efficiency of melt-blown and currently used glass fiber filter media under the same environmental conditions. To evaluate filter efficiency, filter class was determined according to ISO and European standards (EN 1822-1:2009) using an automated filter tester (0.3 μm size), taking into account particle filtration, fractional efficiency for negative pressure devices, and consumption of electrical power. The average fractional efficiency, quality factor (QF), fractional efficiency by dust loading amount, pressure by dust loading amount, and QF by dust loading amount were higher in the case of melt-blown media than in the case of glass fiber filters. The fractional efficiency of hydrocharged melt-blown filters was higher than that of uncharged media. Based on performance efficiency, melt-blown filters are more effective high efficiency particulate air filters than glass fiber media.

Copyright © 2018 American Association for Aerosol Research  相似文献   


12.
Cabin air filters are the main barrier for protecting automobile passengers from on road particulate matter. There are many studies about the evaluation of their performance in terms of filtration efficiency. However, the knowledge about the loading capacity of them is still lacking. Meanwhile, there has been no quantitative method to estimate the proper filter service life time. This study focuses on testing the loading capacity of different types of cabin air filters under the conditions of different relative humidity values and particle types. The results indicate that when the relative humidity increases, the activated carbon coated filters can adsorb significant amounts of water with no significant increase of the pressure drop. The normal fibrous filters show in contrast negligible water adsorbance. Compared with the filters loaded by Arizona road dust only, loading the filters by Arizona road dust and soot particles simultaneously will result in the steeper loading curves as well as the shift of most penetrating particle size to the smaller diameter. Finally, a new method to estimate the proper service life time of the cabin air filters is suggested based on the loading curves.

© 2016 American Association for Aerosol Research  相似文献   


13.
This paper presents results from a water treatment pilot testing program in Winnipeg, Canada (pop. 650,000) which evaluated a DAF/ozone/deep bed filtration process. As part of the testing program, biological filtration using GAC and anthracite media was assessed for the removal of ozone DBPs and background chlorine DBPs (due to upstream chlorination of the source water). The results were used to evaluate the effectiveness of biological filtration for DBP removal.

High filtration rates were tested in this study. The 2.1m deep filters were run at a hydraulic loading rate (HLR) of 35 m/h with an empty bed contact time (EBCT) of only 3.6 minutes.

The important findings of this work are

?The high-rate biologically active carbon (BAC) filters met the objective of controlling ozone DBPs. These results confirm that high rate, low EBCT filters can provide significant biodegradation. Anthracite biofilters provided significantly less removal of ozone DBPs.

?The high rate BAC filters showed significant reduction of background HAAs. BAC reduced the background HAAs to below the long-term target of 30 μg/L. Anthracite biofilters did not exhibit HAA removal.

?Biological filtration with either media was ineffective for background THM removal. The long-term target of 40 μg/L could not be achieved without GAC adsorption.  相似文献   


14.
The silicon carbide (SiC) ceramic filter is the most favorable component to remove particulate matter from hot flue gas due to its high filtration efficiency and high thermal durability. The effect of SiC powder size on the physical properties and filtration performance to prepare high-performance granular ceramic filter media was investigated in this study. Disk-type filter media were prepared by mixing ceramic components followed by physical compression and sintering. The porosity and average pore diameter in the filter media increased with increasing powder size. However, the mechanical strength decreased with increasing powder size, while it increased with increasing physical compressive force. The filter performance factor, qFM was introduced to evaluate the ceramic filter properties, and the SiC50 filter was the best of the ceramic filters prepared in this study. We also found that diffusion was a dominant collection mechanism for particles smaller than 0.7 μm, and direct interception and inertia were dominant collection mechanisms for particles larger than 0.7 μm in the SiC50 filter based on a single collector efficiency model. In addition, the predicted collection efficiencies showed reasonably good agreement with the experimental ones.

Copyright 2014 American Association for Aerosol Research  相似文献   


15.
We describe an approach to filtration-efficiency calculations as an alternative to the traditional depth filtration theory. The new approach involves linking the single-fiber efficiency to the collision rate coefficient/kernel between nanoparticles and fibers, and correspondingly inferring the collision kernel via dimensionless mean first-passage time (MFPT) calculations. This method has the advantage of easily incorporating the influences of particle diffusion, inertia, and particle size; therefore, all filtration mechanisms can be considered simultaneously. Through non-dimensionalization of the equation of motion for a particle in MFPT calculations (the Langevin equation), it is shown that both the single-fiber efficiency Ef and dimensionless particle-fiber collision kernel, H, are functions of the ratio of particle radius to filter-fiber radius, R, the solid volume fraction in the filter, Vf, the ratio of particle persistence distance to the particle-filter collision distance, KnD (the diffusive Knudsen number), and the ratio of the particle translational kinetic energy to the thermal energy χf. Using a Kuwabara flow-cell model to define the geometry and flow field, MFPT calculations are used to determine H and Ef for nanoparticles in atmospheric pressure systems, i.e., when particle inertia is negligible but when diffusion and interception act in tandem to collect particles. From MFPT results, regression equations for both H and Ef are developed. A comparison is made between MFPT results and commonly invoked depth-filtration single-fiber efficiency relationships, experimentally measured values, and H equations derived from Sherwood number correlations based upon measurements of heat transfer from a fluid flowing perpendicular to an array of cylinders. Good agreement is found with both measurements and previously developed equations over a wide range of parameter space.

Copyright 2014 American Association for Aerosol Research  相似文献   


16.
Soot particle removal performance of two types of metallic filter media, sintered metal powder and sintered metal fiber, is experimentally evaluated as potential improvements to conventional ceramic filtration media for gasoline direct injection (GDI) engine PM after-treatment application. Soot collection efficiency and flow resistance of several grades of metallic media are measured at temperatures of 25, 350, and 650°C and a range of representative filtration velocities for sub-micrometer soot particles generated from a propane flame. Theoretical collection efficiency based on single fiber efficiency theory shows good agreement with experimental data for nearly spherical KCl particles at 350°C. Improved collection efficiency is observed for soot particles in the interception-dominated size range above ~100 nm due to enhanced interception length. Soot collection is slightly enhanced at higher temperature, which is consistent with model predictions. Sintered metal fiber media are found capable of removing ~75% of soot particles by mass with an incremental flow resistance of less than 1.5 kPa under 10 cm/s and 350°C, which is promising for gasoline particulate filter (GPF) application. The media level figure of merit (FOM) is used to quantify the soot collection efficiency versus flow resistance tradeoff of all media tested. It is found that due to their more open structure (higher porosity) sintered metal fiber media have FOMs nearly one order of magnitude higher than those of sintered metal powder media, and by analogy those of conventional wall flow ceramic media. This suggests that sintered metal fiber media represents an attractive alternative to ceramic media for designing GPFs; however, further research into creating comparable surface area to the honeycomb structures used for wall flow filters is needed to extract the full potential of metal fiber media.

Copyright © 2017 American Association for Aerosol Research  相似文献   


17.
Filtration performances of air handling unit (AHU) filters for particles and microbial aerosols were investigated. The influence of the AHU operational conditions on the behavior of microorganisms collected on the filters was also studied. A lab-scale AHU with two filtration stages was developed and validated for the study of downsized filters with industrial geometries. Three types of filters of different efficiency were considered: G4, F7, and F9, according to European standard EN 779. Two configurations of filters were studied: G4 pleated/F7 bag and F7/F9 bag. Filters were sequentially clogged by alumina particles, which provided a mineral fraction in the particulate cake, and then by micronized rice particles, which provided the fungus Penicillium chrysogenum and an organic fraction that acts as a substrate for microorganisms. Finally, a microbial aerosol composed of endospores of Bacillus subtilis and spores of Aspergillus niger was nebulized to contaminate filters. After clogging, periods of 5 days on and 2 day weekend stops with restarts of ventilation were simulated for 6 weeks. The results showed that the filter efficiency for particles was quite comparable to that for microbial aerosols expressed in cultivable concentration. The particulate cake composed of alumina and micronized rice particles enabled the growth of the endogenous species P. chrysogenum and the survival of exogenous species B. subtilis and A. niger on filters. During restarts of ventilation, low particle concentrations were detected downstream of the second filtration stages by release but the microbial concentration from the fraction of air sampled was below the detection limit.

© 2016 American Association for Aerosol Research  相似文献   


18.
The dust loading has a significant influence on the transient performance of air filters. This study developed two models based on the Lagrangian and Eulerian methods to simulate the unsteady filtration process in the pleated filter. The flow field through the filter was calculated by solving the Navier-Stokes equation with the DES-SA turbulence model. The filter media and the cake layer were modeled as the porous zone. The Lagrangian method tracked the particle trajectories to model the particle motion, but the Eulerian model treated the particle as continuous phase. Two cell models were proposed to simulate the transient particle deposition and the cake layer growth on the filter medium surface for the Lagrangian and Eulerian methods, respectively. The simulated results were validated by the available experimental data. Both of the methods could provide relative accurate results with acceptable error. But the computing speed of Eulerian model was faster than the Lagrangian method. Otherwise, the new developed Eulerian model was used to investigate the effect of dust loading on the optimal design of pleated filter.

© 2016 American Association for Aerosol Research  相似文献   


19.
We investigate, through simulation, a system of aggregating particles in the free molecular regime that undergoes a crossover from ballistic to diffusive motion. As the aggregates grow, the aggregate mean free path becomes smaller and the motion between collisions becomes more diffusive. From growth kinetics, we find that when the ratio of the aggregate mean path to the mean aggregate nearest neighbor separation reaches of the order of unity, a crossover to diffusive motion occurs. This ratio, called the nearest neighbor Knudsen number, becomes an important parameter in understanding aerosol aggregation in the free molecular regime.

Copyright 2014 American Association for Aerosol Research  相似文献   


20.
The performance of electrostatically charged blown microfiber filter media was characterized for high-volume sampling applications. Pressure drop and aerosol collection efficiency were measured at air pressures of 55.2 and 88.7 kilopascals (kPa) and filter face velocities ranging from 2.5 to 11.25 meters per second (m/s). Particle penetration was significant for particles above 0.5 micrometers (μm) in aerodynamic diameter where the onset of particle rebound was observed as low as 200 nanometers (nm). Particle retention was enhanced by treating filters in an aqueous solution of glycerol. Adding this retention agent eliminated electrostatic capture mechanisms but mitigated inertial rebound. Untreated filters had higher nanoparticle collection efficiencies at lower filter face velocities where electrostatic capture was still significant. At higher filter face velocities, nanoparticle collection efficiencies were higher for treated filters where inertial capture was dominant and particle rebound was mitigated. Significant improvements to microparticle collection efficiency were observed for treated filters at all air flow conditions. At high air pressure, filter efficiency was greater than 95% for particles less than 5 μm. At low air pressure, performance enhancements were not as significant since air velocities were significantly higher through the fiber mat. Measured single fiber efficiencies were normalized by the theoretical single fiber efficiency to calculate adhesion probability. The small fiber diameter (1.77 μm) of this particular filter gave large Stokes numbers and interception parameters forcing the single fiber efficiency to its maximum theoretical value. The adhesion probability was plotted as a function of the ratio of Stokes and interception parameter similar to the works of others. Single fiber efficiencies for inertial nanoparticle collection were compared to existing theories and correlations.

Copyright 2014 American Association for Aerosol Research  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号