首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper, an attempt has been made to evaluate the overall performance of hybrid PV/thermal (PV/T) air collector. The different configurations of hybrid air collectors which are considered as unglazed and glazed PV/T air heaters, with and without tedlar. Analytical expressions for the temperatures of solar cells, back surface of the module, outlet air and the rate of extraction of useful thermal energy from hybrid PV/T air collectors have been derived. Further an analytical expression similar to Hottel–Whiller–Bliss (HWB) equation for flat plate collector has also been derived in terms of design and climatic parameters. Numerical computations have been carried out for composite climate of New Delhi and the results for different configurations have been compared. The thermal model for unglazed PV/T air heating system has also been validated experimentally for summer climatic conditions. It is observed that glazed hybrid PV/T without tedlar gives the best performance.  相似文献   

2.
In this communication, an analytical expression for the water temperature of an integrated photovoltaic thermal solar (IPVTS) water heater under constant flow rate hot water withdrawal has been obtained. Analysis is based on basic energy balance for hybrid flat plate collector and storage tank, respectively, in the terms of design and climatic parameters. Further, an analysis has also been extended for hot water withdrawal at constant collection temperature. Numerical computations have been carried out for the design and climatic parameters of the system used by Huang et al. [Huang BJ, Lin TH, Hung WC, Sun FS. Performance evaluation of solar photovoltaic/thermal systems. Sol Energy 2001; 70(5): 443–8]. It is observed that the daily overall thermal efficiency of IPVTS system increases with increase constant flow rate and decrease with increase of constant collection temperature. The exergy analysis of IPVTS system has also been carried out. It is further to be noted that the overall exergy and thermal efficiency of an integrated photovoltaic thermal solar system (IPVTS) is maximum at the hot water withdrawal flow rate of 0.006 kg/s. The hourly net electrical power available from the system has also been evaluated.  相似文献   

3.
Performance evaluation of solar photovoltaic/thermal systems   总被引:6,自引:0,他引:6  
The major purpose of the present study is to understand the performance of an integrated photovoltaic and thermal solar system (IPVTS) as compared to a conventional solar water heater and to demonstrate the idea of an IPVTS design. A commercial polycrystalline PV module is used for making a PV/T collector. The PV/T collector is used to build an IPVTS. The test results show that the solar PV/T collector made from a corrugated polycarbonate panel can obtain a good thermal efficiency. The present study introduces the concept of primary-energy saving efficiency for the evaluation of a PV/T system. The primary-energy saving efficiency of the present IPVTS exceeds 0.60. This is higher than for a pure solar hot water heater or a pure PV system. The characteristic daily efficiency ηs* reaches 0.38 which is about 76% of the value for a conventional solar hot water heater using glazed collectors (ηs*=0.50). The performance of a PV/T collector can be improved if the heat-collecting plate, the PV cells and the glass cover are directly packed together to form a glazed collector. The manufacturing cost of the PV/T collector and the system cost of the IPVTS can also be reduced. The present study shows that the idea of IPVTS is economically feasible too.  相似文献   

4.
Performance evaluation of solar PV/T system: An experimental validation   总被引:8,自引:2,他引:6  
In this communication, an attempt has been made to develop a thermal model of an integrated photovoltaic and thermal solar (IPVTS) system developed by previous researchers. Based on energy balance of each component of IPVTS system, an analytical expression for the temperature of PV module and the water have been derived. Numerical computations have been carried out for climatic data and design parameters of an experimental IPVTS system. The simulations predict a daily thermal efficiency of around 58%, which is very close to the experimental value (61.3%) obtained by Huang et al.  相似文献   

5.
The objective of this work is to simulate a water-based flat plate photovoltaic/thermal system with glass cover and without it in laminar and turbulent regime and investigating the effects of solar irradiation, packing factor, Reynolds number, collector length, pipes diameter and number of pipes on the performance of this system. The accuracy of the model has been validated with the available data in the literature, where good agreements between the results have been achieved. The results showed that the energy efficiency in the glazed photovoltaic/thermal system is higher than unglazed one, while its exergy efficiency depends on the packing factor, Reynolds number and collector length. The results also indicated that increasing of solar radiation and packing factor increases total energy and exergy efficiency in both laminar and turbulent regime. Besides, it was found that there are the optimum values for mass flow rate and number of pipes that maximize exergy efficiency. The value of the optimum mass flow rate is larger in the case of unglazed system compared to that of glazed one. Furthermore, in most cases, the total energy efficiency in turbulent regime is higher, whereas the total exergy efficiency in laminar regime is superior.  相似文献   

6.
In photovoltaic–thermal (PV/T) technology, the use of glass cover on the flat-plate hybrid solar collector is favorable to the photothermic process but not to the photovoltaic process. Because of the difference in the usefulness of electricity and thermal energy, there is often no straight forward answer on whether a glazed or unglazed collector system is more suitable for a specific application. This glazing issue was tackled in this paper from the viewpoint of thermodynamics. Based on experimental data and validated numerical models, a study of the appropriateness of glass cover on a thermosyphon-based water-heating PV/T system was carried out. The influences of six selected operating parameters were evaluated. From the first law point of view, a glazed PV/T system is found always suitable if we are to maximize the quantity of either the thermal or the overall energy output. From the exergy analysis point of view however, the increase of PV cell efficiency, packing factor, water mass to collector area ratio, and wind velocity are found favorable to go for an unglazed system, whereas the increase of on-site solar radiation and ambient temperature are favorable for a glazed system.  相似文献   

7.
The overall electrical efficiency of the photovoltaic (PV) module can be increased by reducing the temperature of the PV module by withdrawing the thermal energy associated with the PV module. In this communication an attempt has been made to develop analytical expression for electrical efficiency of PV module with and without flow as a function of climatic and design parameters. The four different configurations of PV modules are considered for the present study which are defined as; case A (Glass to glass PV module with duct), case B (Glass to glass PV module without duct), case C (Glass to tedlar PV module with duct), case D (Glass to tedlar PV module without duct). Further, experiments were carried out for all configurations under composite climate of New Delhi.  相似文献   

8.
The use of unglazed transpired solar collectors for desiccant regeneration in a solid desiccant cooling cycle was investigated because these collectors are less expensive than conventional glazed flat-plate collectors. Using computer models, we studied the performance of a desiccant cooling ventilation cycle integrated with either unglazed transpired collectors or conventional glazed flat-plate collectors. We found that the thermal coefficient of performance of the cooling system with unglazed collectors was lower than that of the cooling system with glazed collectors because the former system did not use the heat of adsorption released during the dehumidification process. Although the area required for the unglazed collector array was 70% more than that required for the glazed collector array in a 10.56 kW (3 ton) solar cooling system, the cost of the unglazed array was 45% less than the cost of the glazed array. The simple payback period of the unglazed collector was half of the payback period of the glazed collector when replacing an equivalent gas-fired air heater. Although the use of unglazed transpired collectors seems to make economic sense relative to use of glazed conventional collectors, some practical considerations may limit their use for desiccant regeneration.  相似文献   

9.
利用太阳能空气加热系统实验台,对黑、深绿和深蓝3种颜色无盖板渗透型集热器的热性能进行了户外瞬态对比试验。试验结果表明:太阳辐射照度和风量是影响系统热性能的重要因素。在高档和低档两种风量下,黑色集热器的瞬时平均热效率分别为76.04%和67.50%,高于普通平板太阳能空气集热器;集热器表面颜色对其热性能有一定影响,在高档和低档两种风量下,深绿色和深蓝色集热器的瞬时平均热效率比黑色集热器低15%~22%,空气温升低3~4℃,但仍然优于普通平板空气集热器。从保持建筑立面美观考虑,无盖板渗透型集热器的集热板可以采用颜色较深的彩色,不会对系统热性能造成较大影响。  相似文献   

10.
The integration of solar collectors in buildings should be compatible with the architectural design, and solar collectors with colored absorbers would be aesthetically preferable. In our laboratory we constructed and tested flat plate solar collectors with colored absorbers for water heating applications. The study includes collectors in their typical form with the protective glazing, and also collectors without glazing. Unglazed solar collectors are not widely used, although they are cost effective solar devices, suitable for low temperature thermal applications. We tested outdoors the constructed models, glazed and unglazed, with black, blue and red brown absorbers. In order to overcome the high thermal losses of the unglazed collectors and the low optical efficiency of the colored absorbers, we used flat booster reflectors. The additional solar radiation input from the reflectors increases the thermal energy output of the collectors, improving their performance. Theoretical steady state efficiency curves are also given for collectors with or without glazing. The presented experimental and theoretical results determine the range of the effective operation of the proposed solar collector types, which can be used in a variety of applications, instead of glazed or unglazed solar collectors with a black absorber.  相似文献   

11.
This study includes design and experimental analysis of a solar domestic water heating system. Water heating systems with glazed and unglazed collectors were constructed and tested at Dhaka, Bangladesh, at a latitude of 23.7 °N. Collector thermal efficiency and capability of raising water temperature were considered as performance evaluation measures. A typical day analysis showed that collector efficiency varied with time and touched its peak at around 12:00 h. During testing, the efficiency of the glazed collector increased by about 70.3% when compared with the unglazed collector. Average collector efficiency over the whole test period was also estimated to be 57.3% and 33.7% for glazed and unglazed collectors, respectively. Maximum water temperatures measured at daytime user outlets were, respectively, 82.4 °C and 65.5 °C for domestic water heating systems with glazed and unglazed collectors and approximated to be 49 °C and 32 °C higher than the ambient temperature. The glazed collector eventually offered significantly higher performances over the unglazed collector in improving system performance.  相似文献   

12.
无盖板渗透型太阳能空气集热器是一种易于实现建筑一体化的高效新风预热及干燥装置。为了掌握无盖板渗透型集热器在实际工况下的热性能,建造了集热面积为2.2 m2的太阳能空气加热系统实验台,并在2009年2月至2009年4月对其热性能进行了户外瞬态实验研究。实验结果表明出口空气温度随辐射强度的增加而升高,太阳辐射强度是影响集热器出口空气温度的最重要因素,而室外空气温度的影响极小。空气温升随风量的增加而减小,集热器热效率随风量的增加而增大。在三个测试日中集热器的平均热效率分别为58%、63%和72%,高于普通平板太阳能空气集热器。  相似文献   

13.
An attempt has been made to utilise solar energy more efficiently by developing the single pass hybrid photovoltaic thermal system at the climatic condition of Bangladesh. As the electric energy conversion efficiency of the photovoltaic module falls with the surrounding temperature and air or water used as a suitable solution to make it cool. In this study, air was used as the cooling medium for the solar panel and circular copper tube was placed on the glazed collector for water heating to ensure maximum exploitation of solar energy. Moreover, the photovoltaic panel power was used to circulate the air and make the system self-powered. Maximum collector efficiency was 24.64% for water and 11.20% for air is observed at a mass flow rate 0.00158 and 0.00221 kg/s for water and air respectively at a solar radiation of 1050 W/m2. In addition, the combined efficiency of the hybrid system was about 39.68%. By adding glycerin with water at a ratio of 50:1 (% of weight) the combined efficiency reached up to 45.76%. The computational fluid dynamics (CFD) simulation and economic analysis of the designed system strongly support the feasibility of the solar hybrid photovoltaic thermal system as the future sustainable energy source.  相似文献   

14.
Performance of jet impingement in unglazed air collectors   总被引:1,自引:0,他引:1  
Jet impingement is effective at improving the heat transfer between air and a heated surface. Studies have shown that jet impingement can marginally improve the thermal efficiency of a glazed collector. However, little attention has been placed on applying jet impingement to an unglazed solar air collector. This paper presents a theoretical and experimental investigation identifying the performance characteristics of jet impingement. Overall, jet impingement was able to improve the thermal efficiency of the collector by 21%. An increase in the pressure loss was also measured but found to be small. The flow distribution of jets along the collector was the most significant factor in determining the efficiency. Increasing the hole spacing was found to improve the efficiency.  相似文献   

15.
Unglazed transpired collectors or UTC (also known as perforated collectors) are a relatively new development in solar collector technology, introduced in the early nineties for ventilation air heating. These collectors are used in several large buildings in Canada, USA and Europe, effecting considerable savings in energy and heating costs. Transpired collectors are a potential replacement for glazed flat plate collectors. This paper presents the details of a mathematical model for UTC using heat transfer expressions for the collector components, and empirical relations for estimating the various heat transfer coefficients. It predicts the thermal performance of unglazed transpired solar collectors over a wide range of design and operating conditions. Results of the model were analysed to predict the effects of key parameters on the performance of a UTC for a delivery air temperature of 45–55 °C for drying applications. The parametric studies were carried out by varying the porosity, airflow rate, solar radiation, and solar absorptivity/thermal emissivity, and finding their influence on collector efficiency, heat exchange effectiveness, air temperature rise and useful heat delivered. Results indicate promising thermal performance of UTC in this temperature band, offering itself as an attractive alternate to glazed solar collectors for drying of food products.The results of the model have been used to develop nomograms, which can be a valuable tool for a collector designer in optimising the design and thermal performance of UTC. It also enables the prediction of the absolute thermal performance of a UTC under a given set of conditions.  相似文献   

16.
无盖板PV/T组件相比于盖板式PV/T组件有更高的光电转换效率,在电能输出方面的优势明显。基于此,提出一种无盖板型水冷式PV/T模块,并搭建由光伏对比模块、水冷式PV/T模块以及无冷却水循环的PV/T对比模块构成的实验平台开展对比实验,研究温度、流量对无盖板PV/T模块电、热转换效率的影响。结果表明,在水冷作用下,PV/T模块的光伏组件温度显著降低,与PV/T对比模块相比发电效率提升11.54%;环境平均温度为21.7 ℃、平均辐照度650 W/m2的测试条件下,流量0.12 m3/h时模块的电效率为17.44%,热效率为19.80%,综合效率达到65.69%,考虑到循环泵消耗的电能,表面积1.93 m2的水冷式PV/T模块全天可存储有效能3.72 MJ。  相似文献   

17.
The paper presents the results of experimentally supported numerical analysis performed in order to investigate the possibilities to improve the thermal efficiency of plate solar collectors. Different numerical models were developed in order to asses the influence of design and operating parameters such as bond conductance between absorber plate and tube, tube diameter, glass cover to absorber plate distance, optical properties of absorber and flow rate on thermal efficiency of collectors. Following the results, two designs of collector without tubes, with parallel flat and corrugated absorber plates of chevron type, is further considered and shown to be an effective way to increase the thermal efficiency of solar energy conversion beyond that of commercial glazed and unglazed solar water heaters. Based on the results, the guidelines for design of a new collector prototype consisting of chevron type corrugated plates normally used in plate heat exchangers are provided.  相似文献   

18.
渗透型太阳能空气集热器集热效率研究   总被引:5,自引:0,他引:5  
将CFD模拟引入太阳能空气集热器设计研究领域,对渗透型太阳能空气集热器(UTC)的工作特性进行了模拟分析,并与传统空气集热器进行了比较.在数值模拟的基础上,制作了几种实验模型并进行了实验研究,对其送风温度和热效率进行了测试.通过模拟和模型实验,说明了UFC在新风预热领域中无可比拟的优势,显示了CFD工具在空气集热器研究领域中的优势.  相似文献   

19.
The electrical efficiency of a photovoltaic system drops as its operating temperature rises and PV cooling is necessary. The photovoltaic/thermal (PV/T) system is a relatively recent type of solar collector where a circulating fluid of lower temperature than PV module extracts heat from it, cooling the module to improve its output power while the solar pre-heated fluid provides sensible heat. In the present work, air cooling of a commercial PV module configured as PV/T air solar collector by natural flow is presented, where two low cost modification techniques to enhance heat transfer to air stream in the air channel are studied. The considered methods consist of thin metal sheet suspended at the middle or fins attached to the back wall of the air-channel to improve heat extraction from the module. A numerical model was developed and validated against the experimental data obtained from outdoor test campaigns for both glazed and unglazed PV/T prototype models studied. The validation results show good agreement between predicted values and measured data and thus could be used to study analytically the performance of these PV/T air collectors with respect to several design and operating parameters. The modified systems present better performance than the usual type and will contribute to better performance of integrated PV systems for natural ventilation applications in buildings, both space cooling and heating.  相似文献   

20.
The performance of two collectors/regenerators, one glazed and the other unglazed, was studied when tested side-by-side under the meteorological conditions of Tempe, Arizona. One half of an 11 m by 11 m roof structure was covered with a series of seven Tedlar panels, each measuring 1.76 cm by 4.88 m, and the other remained unglazed. When the performance of the collector/regenerator (C/R) was expressed in terms of the quantity of water evaporated from it, which in effect was a measure of the cooling capacity of the system, the unglazed C/R performed better than the glazed C/R under the climatic conditions considered here. Nondimensional correlations for heat and mass transfer were developed from the experimental data for subsequent use with a performance model. The glazed C/R was found less sensitive to changes in independent variables and its regeneration efficiency was, on the average, 7.6% lower than the unglazed C/R. The performance of the glazed C/R approaches that of unglazed C/R at a larger height of the glazing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号