首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Columns employed so far in capillary electrochromatography (CEC) contain both a packed and an open segment with concomitant changes of the electric field strength and the flow velocity at the interface of the two segments in such duplex columns. To take this into account in measuring, processing, and interpreting CEC data, a framework is presented for the evaluation of the conductivity ratio and the interstitial electrosmotic flow (EOF) mobility and their usage as tools for characterizing CEC columns. This is illustrated by experimental data obtained from measurement of the current and the EOF in capillary columns packed with different stationary phases. The current data yielded the ratio of the conductivities of the packed and open segments that has been shown to be useful for the evaluation of the porosity and tortuosity. It is assumed that these important packing characteristics are the same for the flow of current and for the flow of the bulk mobile phase in the CEC column. The EOF mobility in such duplex columns is defined in two different ways. The apparent mobility, which is widely reported at present, is obtained from the length of packed segment, the migration time, and the overall electric field strength. On the other hand, the actual mobility is obtained after taking into account the porosity and tortuosity of the packing as well. Thus, the actual mobility is made independent of the porosity and tortuosity and therefore can be useful to estimate the zeta potential for characterizing the packing surface. Measurements of both the apparent and actual electrosmotic mobilities for a number of different columns have shown that the apparent and actual mobilities are significantly different in their magnitude. For this reason, it is recommended that, instead of the apparent EOF mobility, the actual mobility is used for the characterization of the packing in CEC columns.  相似文献   

2.
Hayes JD  Malik A 《Analytical chemistry》2000,72(17):4090-4099
Sol-gel chemistry was used to prepare porous monolithic columns for capillary electrochromatography. The developed sol-gel approach proved invaluable and generates monolithic columns in a simple and rapid manner. Practically any desired column length ranging from a few tens of centimeters to a few meters may be readily obtained. The incorporation of the sol-gel precursor, N-octadecyldimethyl[3-(trimethoxysilyl)propyl]ammonium chloride, into the sol solution proved to be critical as this reagent possesses an octadecyl moiety that allows for chromatographic interactions of analytes with the monolithic stationary phase. Additionally, this reagent served to yield a positively charged surface, thereby providing the relatively strong reversed electroosmotic flow (EOF) in capillary electrochromatography. The enhanced permeability of the monolithic capillaries allowed for the use of such columns without the need for modifications to the commercial CE instrument. There was no need to pressurize both capillary ends during operation or to use high pressures for column rinsing. With the developed procedure, no bubble formation was detected during analysis with the monolithic capillaries when using electric field strengths of up to 300 V cm(-1). The EOF in the monolith columns was found to be dependent on the percentage of organic modifier present in the mobile phase. Separation efficiencies of up to 1.75 x 10(5) plates/m (87,300 plates/column) were achieved on a 50 cm x 50 microm i.d. column using polycyclic aromatic hydrocarbons and aromatic aldehydes and ketones as test solutes.  相似文献   

3.
Bubble formation, which is associated with bed-retention frits, is a critical experimental problem in capillary electrochromatography systems. In this investigation, porous silica frits were prepared via spot-heating of a silicate solution, and the effects of several experimental parameters on their performance were studied. The optimal sodium silicate concentrations were 10.8% and 5.4% (w/v) for outlet and inlet frits, respectively. The heating times were 5-6 s for outlet frits and < 1 s for inlet frits. Under optimized conditions, outlet frits were 75 microns (+/- 12 microns) and the heat treatment did not make the capillary fragile at the frit location. Bubble formation was affected by frit length, density, and silanization of the frits with trimethylchlorosilane. Packed capillaries with optimized frits were used successfully in a commercial CE instrument over a normal working day without pressurization, at relatively high ionic strengths (10 mM), and over a wide range of acetonitrile compositions (20%-80%). Currents were also stable for > or = 3 h under very high current (27 microA) conditions. As part of this study, the efficiency and reproducibility of packed capillaries were also briefly evaluated.  相似文献   

4.
Sol-gel chemistry was successfully used for the fabrication of open tubular columns with surface-bonded octadecylsilane (ODS) stationary-phase coating for capillary electrochromatography (OT-CEC). Following column preparations, a series of experiments were performed to investigate the performance of the sol-gel coated ODS columns in OT-CEC. The incorporation of N-octadecyldimethyl[3-(trimethoxysilyl)propyl]ammonium chloride as one of the sol-gel precursors played an important role in the electrochromatographic performance of the prepared columns. This chemical reagent possesses a chromatographically favorable, bonded ODS moiety, in conjunction with three methoxy groups allowing for sol-gel reactivity. In addition, a positively charged nitrogen atom is present in the molecular structure of this reagent and provides a positively charged capillary surface responsible for the reversed electroosmotic flow (EOF) in the columns during CEC operation. Comparative studies involving the EOF within such sol-gel ODS coated and uncoated capillaries were performed using acetonitrile and methanol as the organic modifiers in the mobile phase. The use of a deactivating reagent, phenyldimethylsilane, in the sol-gel solution was evaluated. Efficiency values of over 400,000 theoretical plates per meter were achieved in CEC on a 64 cm x 25 microm i.d. sol-gel ODS open tubular column. Test mixtures of polycyclic aromatic hydrocarbons, benzene derivatives, and aromatic aldehydes and ketones were used to evaluate the CEC performances of both nondeactivated and deactivated open tubular sol-gel columns. The effects of mobile-phase organic modifier contents and pH on EOF in such columns were evaluated. The prepared sol-gel ODS columns are characterized by switchable electroosmotic flow. A pH value of approximately 8.5 was found correspond to the isoelectric point for the prepared sol-gel ODS coatings.  相似文献   

5.
He Y  Geng L 《Analytical chemistry》2001,73(22):5564-5575
The distribution of solute molecules in the stationary phase in capillary electrochromatography (CEC) has been investigated with time-resolved fluorescence in the frequency domain. The analysis of fluorescence decay poses a challenging problem for the complex decay kinetics of heterogeneous systems such as the C18 stationary phase. The nonlinear least-squares (NLLS) method selects the decay model by minimizing the chi2 value. The chi2 criterion, in conjunction with the requirement that the residues should be randomly distributed around zero, frequently leads to a feasible set of multiple decay models that can all fit the data satisfactorily. The maximum entropy method (MEM) further chooses a unique model from the group of feasible ones by maximizing the Shannon-Jaynes entropy. The unique model, however, is not necessarily the most probable one. In this paper, the best model for the fluorescence decays of solute molecules is selected with NLLS using the chi2 statistics, the stability of the fit, and the consistency within replicate experiments. In addition, the recovered lifetime parameters of the true model should display the same trend as the fluorescence decay profiles when an experimental condition is varied. Using these criteria, a Gaussian distribution of fluorescence lifetimes satisfactorily fits the data under all experimental conditions. An additional minor component with a discrete lifetime is attributed to the systematic errors in the measurements. The distribution is a manifestation of an ensemble of heterogeneous microenvironments in the stationary phase of CEC. MEM is not suitable for the modeling of CEC data because of its inaccuracy in recovering broad fluorescence lifetime distributions and its lack of consistency in the replicate measurements in the studies of high-voltage effects.  相似文献   

6.
Two sets of peptides, each having structurally similar amino acid sequences, have been investigated by capillary electrochromatography (CEC) using etched chemically modified capillaries as the separation medium. In comparison to gradient RP-HPLC, the resolving power of the described CEC methods has been found to be superior. A number of variables have been examined with respect to optimization of the separation of these closely related peptides with several different etched chemically modified capillaries. These experimental variables included the nature of the bonded moiety, the pH, the organic modifier type, and the amount of organic modifier in the buffer electrolyte. Systematic variation of these parameters results in significant changes in the migrational behavior of the investigated peptides and provides important insight into the underlying molecular separation processes that prevail in open tubular CEC. Moreover, under optimized conditions, efficient separations characterized by highly symmetrical peaks were achieved. In addition, this study has permitted the long-term stability as well as the short-term and long-term reproducibility of the etched chemically modified capillaries to be documented.  相似文献   

7.
Que AH  Novotny MV 《Analytical chemistry》2002,74(20):5184-5191
While developing a combination of capillary electrochromatography (CEC) with tandem mass spectrometry (MS) for the benefit of characterizing complex oligosaccharide mixtures, we needed highly efficient CEC columns operating in an "MS-friendly" mode. We demonstrate here novel types of polar, monolithic CEC columns that separate effectively complex mixtures of saccharides with the use of mobile phases containing acetonitrile/dilute ammonium formate buffers. Using the positive-ion mode of detection for neutral saccharides, the detection conditions were optimized down to the low-femtomole sensitivities with the use of an ion trap mass spectrometer. This column technology provides a nearly universal system that can separate a wide range of carbohydrates: mono- and oligosaccharides with the intact reducing end, as well as saccharide alditols. Even the anomers formed due to mutarotation could be resolved with a high content of organic phase.  相似文献   

8.
A rotary valve nanoinjector was devised for use in capillary electrophoresis (CE) and capillary electrochromatography (CEC). A fused-silica capillary tip was inserted in a small through-hole in the rotor. The narrow and short capillary tip, with an inner volume of 6-24 nL, was embedded in the hole using epoxy resin. The injection volume was confirmed chromatographically by comparing the peak areas obtained with the nanoinjector to those of a conventional injector. In addition, both the rotor and stator of the injector were made of a nonconducting material, polyimide resin, to be utilized for CE and CEC. The application of the nanoinjector for CE was demonstrated.  相似文献   

9.
A novel protein-encapsulation technique using sol-gels was developed for the preparation of monolithic capillary columns for capillary electrochromatography. Two chiral compounds, bovine serum albumin (BSA) and ovomucoid (OVM) from chicken egg white, were encapsulated in tetramethoxysilane-based hydrogel and their chiral selectivity was evaluated for the separation of some selected enantiomers (tryptophan, benzoin, eperisone, chlorpheniramine). The protein encapsulation was carried out within a capillary in a single step under mild conditions. The resultant monolithic columns showed adequate chromatographic performance, including mechanical strength, penetration of pressurized flow, and chiral separation. Two different proteins, BSA and OVM, were successfully encapsulated into the gel matrixes by changing the alkoxysilane compositions of the gel. Run-to-run repeatability was quite satisfactory. The consecutive analysis of the neutral compound, benzoin, by the OVM-encapsulated column showed good repeatability in the retention time (RSD = 1.23% for the first peak, N = 10). Under optimized conditions, the theoretical plate number for the first peak of benzoin reached 72,000 plates/m.  相似文献   

10.
Photopolymerized sol-gel monoliths for capillary electrochromatography   总被引:2,自引:0,他引:2  
A solution of methacryloxypropyltrimethoxysilane in the presence of an acid catalyst, water, toluene, and a photoinitiator was irradiated at 365 nm for 5 min in a 75-microm i.d. capillary to prepare a porous monolithic sol-gel column by a one-step, in situ, process. The photopolymerized sol-gel (PSG) column shows reversed-phase behavior. Using this column, a variety of low-molecular-weight neutral compounds, including polycyclic aromatic hydrocarbons, alkyl benzenes, alkyl phenyl ketones, and steroids are separated from mixtures. Various different operational parameters, such as buffer composition, field strength, and column temperature, were varied to assess their influence on column performance. Use of PSG as a stationary phase for a pressure-driven separation is also demonstrated.  相似文献   

11.
Macroporous polymer frits have been fabricated in fused-silica capillaries by the UV photopolymerization of a solution of glycidyl methacrylate and trimethylopropane trimethacrylate. This in situ preparation is a simple, rapid, and reproducible process. The frit can be placed at any desired position along the column. Photopolymer frits can withstand the short exposure to a high pressure (over 6000 psi). Bubble formation is no observed to occur with these frits under our experimental conditions. By choice of porogens, it is possible to control the porous properties. The use of such frits in capillaries to retain particles of chromatographic packing has been demonstrated to be stable and robust with continuous operation over 3 days.  相似文献   

12.
In this paper, we report on investigations related to the performance characteristics of two different types of etched chemically (n-octadecyl- and cholesterol-) modified capillaries in the open tubular format of capillary electrochromatography (CEC) for the analysis of synthetic peptides. The results confirm that the nature of the surface chemistry used to modify the capillary wall and type of chemically bonded group employed can affect the selectivity as well as the resolution of peptide samples. The results are consistent with the participation of selective peptide interactions with the bonded phase, although other factors, such as the morphology of the capillary wall surfaces, appear to be also involved. Moreover, several surprising observations related to peptide-specific multi-zoning effects have been observed. Additional experimental variables that can also be utilized to affect the retention of peptides in this approach to OTCEC include the type and percentage of organic solvent modifier employed in the eluent and the pH of the buffer system. To evaluate the reproducibility of different batches of the n-octadecyl- and cholesterol-modified capillaries and the stability of the chemically modified surface, the OTCEC selectivity and peak shape behavior of two small basic molecules (serotonin and tryptamine) and two proteins (turkey and chicken lysozyme) were also investigated. Finally, the use of the "bubble" cell technology for creating the detector window has been shown to provide significantly higher detection sensitivity with peptides, as compared with the conventional capillary format.  相似文献   

13.
Wang Y  Zhang Z  Zhang L  Li F  Chen L  Wan QH 《Analytical chemistry》2007,79(13):5082-5086
Fritless packed beds comprised of magnetically responsive octadecylsilane bonded silica particles have been constructed for reversed-phase electrochromatography. The magnetic particles were immobilized in the capillary by applying an external magnetic field transverse to the direction of electroosmotic flow. Being subjected to the interplay of fluid dragging and magnetic forces, the initial loosely packed particle assembly was compacted into a uniform packing structure. The magnetically immobilized beds obtained were used as stationary phases for separation of neutral compounds, with retention behavior and column efficiency similar to those of slurry-packed columns. The results suggest that the magnetic attraction approach to fritless column packing may be used for construction of advanced chip-based chromatography, especially in complex architectures comprising curved and intersecting channels.  相似文献   

14.
Large perfusive silica beads (particle size 110 microm, through pore approximately 2 microm) held in place by the keystone effect were used as single-particle frits for the manufacture of particulate packed capillary columns. High-quality capillary electrochromatographic separations of a standard test mixture of alkylbenzenes were obtained over the full voltage range of 5-30 kV, with no requirement for pressurization. Excellent robustness was demonstrated by the reproducibility of migration times, peak efficiencies, and resolution during 100 consecutive runs at the highest voltage (30 kV) without thermostating and pressurization. Superior performance relative to traditional sinter-fritted columns is ascribed to the heat-free fritting process and short frit length of approximately 110 microm.  相似文献   

15.
Graphene oxide (GO) has received great interest for its unique properties and potential diverse applications. Here, we show the fabrication of GO nanosheets incorporated monolithic column via one-step room temperature polymerization for capillary electrochromatography (CEC). GO is attractive as the stationary phase for CEC because it provides not only ionized oxygen-containing functional groups to modify electroendoosmotic flow (EOF) but also aromatic macromolecule to give hydrophobicity and π-π electrostatic stacking property. Incorporation of GO into monolithic column greatly increased the interactions between the tested neutral analytes (alkyl benzenes and polycyclic aromatics) and the stationary phase and significantly improved their CEC separation. Baseline separation of the tested neutral analytes on the GO incorporated monolithic column was achieved on the basis of typical reversed-phase separation mechanism. The precision (relative standard deviation (RSD), n = 3) of EOF was 0.3%, while the precision of retention time, peak area, and peak height for the tested neutral analytes were in the range of 0.4-3.0%, 0.8-4.0%, and 0.8-4.9%, respectively. In addition, a set of anilines were well separated on the GO incorporated monolith. The GO incorporated monolithic columns are promising for CEC separation.  相似文献   

16.
论文基于苯乙烯基功能整体柱,建立了五种环境雌激素的加压毛细管电色谱分析方法,并应用于鱼肉样品分析。实验考察了有机溶剂浓度、酸度、分离电压、盐浓度、流速等条件对五种雌激素分离的影响。在最优条件下,五种环境雌激素在18 min内实现了基线分离,在4.0×10-7-8.0×10-5g/mL范围内线性良好,检测限在0.8×10-7-5×10-7g/mL范围内。该方法应用于鱼肉实际样的测定,获得回收率范围是78.0%-88.5%。效果良好。  相似文献   

17.
论文应用氰基键合毛细管开管柱,建立了非甾体类抗炎药(舒林酸、芬布芬、布洛芬、萘普生、酮洛芬、氟比洛芬和双氯芬酸钠)的开管毛细管电色谱分析模式。在最优分离条件下,七种非甾体类抗炎药在18分钟内实现良好分离,其线性范围均为1.5×10~(-5)mol/L-4.0×10~(-4)mol/L,检测限在3.5×10~(-6)mol/L-1.0×10~(-5)mol/L之间。应用于猪肝样品分析,平均回收率在85.0%-92.6%之间。该方法为非甾体类抗炎药的分离测定提供了新的技术。  相似文献   

18.
The use of gold nanoparticles in conjunction with etched capillary-based open-tubular capillary electrochromatography (OTCEC) to improve the efficiency of separation and the selectivity between selected solutes is described. The fused-silica capillaries (50-microm i.d.) were etched with ammonium hydrogen difluoride, followed by prederivatization of the new surface with (3-mercaptopropyl)trimethoxysilane (MPTMS) for the immobilization of dodecanethiol gold nanoparticles, for OTCEC. The electrochromatography of a "reversed-phase" test mixture and of selected polycylic aromatic hydrocarbons was investigated, and efficient separations and high theoretical plate numbers per meter were obtained. The electroosmotic flow characteristics of the etched gold nanoparticle capillary, unetched gold nanoparticle capillary, bare capillary, and etched bare capillary were studied by varying the percentage of organic modifier in buffer, buffer pH, and separation voltage. Optical microscopy and scanning electron microscopy were used to examine the process of etching and modification and the surface features of the etched gold nanoparticle capillary. The results confirm that dodecanethiol gold nanoparticles bonded on the etched inner wall of the fused-silica capillary can provide sufficient solute-bonded phase interactions to obtain OTCEC separations with reproducible retention, as well as characteristic reversed-phase behavior, even with the inner diameter of the capillary of 50 microm.  相似文献   

19.
Bailey CG  Yan C 《Analytical chemistry》1998,70(15):3275-3279
The identification of explosives and their degradation products is important in forensic and environmental applications. Complete separation of these structurally similar compounds using reversed-phase liquid chromatography has proven to be a challenge. Here we present a demonstration of the use of capillary electrochromatography on the separation of a series of 14 nitroaromatic and nitramine explosive compounds. A separation with baseline resolution is achieved for all of the compounds in under 7 min, featuring efficiencies of over 500?000 theoretical plates/m. Using more aggressive running conditions, 13 of the 14 compounds are separated in under 2 min.  相似文献   

20.
A critical appraisal of capillary electrochromatography   总被引:1,自引:0,他引:1  
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号