首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
A cloud point extraction (CPE) method for the preconcentration of trace aluminum prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) has been developed. The CPE method is based on the complex of Al(III) with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), and then entrapped in non-ionic surfactant Triton X-114. PMBP was used not only as chelating reagent in CPE preconcentration, but also as chemical modifier in GFAAS determination. The main factors affecting CPE efficiency, such as pH of sample solution, concentration of PMBP and Triton X-114, equilibration temperature and time, were investigated in detail. An enrichment factor of 37 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of this method for Al(III) is 0.09 ng mL(-1), and the relative standard deviation is 4.7% at 10 ng mL(-1) Al(III) level (n=7). The proposed method has been applied for determination of trace amount of aluminum in biological and water samples with satisfactory results.  相似文献   

2.
A novel method has been developed for the speciation of chromium in natural water samples based on cloud point extraction (CPE) separation and preconcentration, and determination by graphite furnace atomic absorption spectrometry (GFAAS). In this method, Cr(III) reacts with 1-phenyl-3-methyl-4-benzoylpyrazol-5-one (PMBP) yielding a hydrophobic complex, which then is entrapped in the surfactant-rich phase, whereas Cr(VI) remained in aqueous phase. Thus, separation of Cr(III) and Cr(VI) could be realized. Total chromium was determined after the reduction of Cr(VI) to Cr(III) by using ascorbic acid as reducing reagent. PMBP was used not only as chelating reagent in CPE procedure, but also as chemical modifier in GFAAS determination of chromium. The detection limit for Cr(III) was 21 ng L(-1) with an enrichment factor of 42, and the relative standard deviation was 3.5% (n=7, c=10 ng mL(-1)). The proposed method has been applied to the speciation of chromium in natural water samples with satisfactory results.  相似文献   

3.
A new micell-mediated phase separation method for preconcentration of ultra-trace quantities of cadmium as a prior step to its determination by flame atomic absorption spectrometry has been developed. The method is based on the cloud point extraction (CPE) of cadmium in iodide media with Triton X-114 in the absence of any chelating agent. The optimal extraction and reaction conditions (e.g., acid concentration, iodide concentration, effect of time) were studied, and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration, and improvement factors) were obtained. Linearity was obeyed in the range of 3-300 ng mL(-1) of cadmium. The detection limit of the method is 1.0 ng mL(-1) of cadmium. The interference effect of some anions and cations was also tested. The method was applied to the determination of cadmium in tap water, waste water, and sea water samples.  相似文献   

4.
Lead and nickel were preconcentrated as their ethylenediaminetetraacedic acid (EDTA) complexes from aqueous sample solutions using a column containing Ambersorb-572 and determined by flame atomic absorption spectrometry (FAAS). pH values, amount of solid phase, elution solution and flow rate of sample solution have been optimized in order to obtain quantitative recovery of the analytes. The effect of interfering ions on the recovery of the analytes has also been investigated. The recoveries of Pb and Ni under the optimum conditions were 99 +/- 2 and 97 +/- 3%, respectively, at 95% confidence level. Seventy-five-fold (using 750 mL of sample solution and 10 mL of eluent) and 50-fold (using 500 mL of sample solution and 10 mL of eluent) preconcentration was obtained for Pb and Ni, respectively. Time of analysis is about 4.5 h (for obtaining enrichment factor of 75). By applying these enrichment factors, the analytical detection limits of Pb and Ni were found as 3.65 and 1.42 ng mL(-1), respectively. The capacity of the sorbent was found as 0.17 and 0.21 mmol g(-1) for Pb and Ni, respectively. The interferences of some cations, such as Mn2+, Co2+, Fe3+, Al3+, Zn2+, Cd2+, Ca2+, Mg2+, K+ and Na+ usually present in water samples were also studied. This procedure was applied to the determination of lead and nickel in parsley, green onion, sea water and waste water samples. The accuracy of the procedure was checked by determining Pb and Ni in standard reference tea leaves sample (GBW-07605). The results demonstrated good agreement with the certified values.  相似文献   

5.
A cloud point extraction method for the preconcentration of ultra-trace bismuth in human serum prior to its determination by inductively coupled plasma optical emission spectrometry had been developed in this paper. The cloud point extraction method was based on the complex of Bi(III) with 8-hydroxyquinoline and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time were investigated in detail. An enrichment factor of 81 was obtained for the preconcentration of Bi(III) with 25 mL solution. Under the optimal conditions, the detection limit of Bi(III) is 0.12 μg L−1. The relative standard deviation (n = 7) of determination was 2.3%, values of recovery of bismuth were from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination trace bismuth in human serum.  相似文献   

6.
A new method of continuous flow microextraction (CFME) combined with graphite furnace atomic absorption spectrometry (GFAAS) was proposed for the determination of trace lead in water samples. A drop of 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP) dissolved in benzene is injected into a glass chamber by a microsyringe and held at the outlet tip of a PTFE connecting tube, the sample solution flows right through the tube and the glass chamber, the solvent drop interacts continuously with the sample solution, and the analyte was extracted into the drop and concentrated. After extracting for a period of time, the drop was retracted into the microsyringe and directly injected into graphite furnace for determination of Pb. Several factors affecting the extraction efficiency, such as solution pH, sample flow rate, drop volume and extraction time, were optimized. Under the optimized conditions, a concentration factor of 45 was achieved, and the detection limits for Pb were 12 pg mL(-1). The relative standard deviation for six replicate analyses of 10 ng mL(-1) Pb was 6.8%. The proposed method was applied to determine of trace Pb in water samples with satisfactory results.  相似文献   

7.
In the present work, an efficient microextraction method was applied to separation and preconcentration of Ni(II), Co(II), Pb(II) and Cr(III). This method is dispersive liquid-liquid microextraction based on solidification of floating organic drop, which overcomes the most important problems of each aforementioned technique. The influences of analytical parameters, including pH, extraction solvent volume, disperser solvent type and its volume, concentration of chelating agent, salt effect and extraction time on the quantitative recoveries of nickel, cobalt, lead and chromium ions were investigated. Under the optimized conditions, the limits of detection were 0.2 ng L(-1) for Cr and 1.3 ng L(-1) for Co, Ni and Pb, with a preconcentration factor of 800 times. The relative standard deviations of 6.2% at 6.0 ng L(-1) of Cr and 7.2% at 10 ng L(-1) of Co, Ni and Pb were obtained (n=7). The proposed method was successfully applied for the analysis of ultra trace metals in water and wastewater samples.  相似文献   

8.
A simple and efficient cloud point extraction-spectrofluorimetric method for the determination of copper(II) in different samples has been proposed. The procedure is based on the oxidation of thiamine with copper(II) to form highly fluorescent thiochrome, its extraction to Triton X-114 micelles and spectrofluorimetric determination. The variables affecting the analytical performance were studied and optimized. The calibration graphs using the preconcentration system for copper were linear over the range 1.0-250 ng ml-1 with limit of detection of 0.29 ng ml-1. Relative standard deviation for five replicate determinations of copper at 100 ng ml-1 concentration level was 2.12%. Average recoveries between 94 and 105% were obtained for spiked samples. The method has been applied to water samples and parenteral solutions and the amounts of copper found are very similar to those obtained by a standard method.  相似文献   

9.
A novel alumina hollow fiber was synthesized by sol-gel template method and was characterized by scanning electron microscopy, N(2) adsorption technique and X-ray diffraction. With the use of prepared alumina hollow fiber as extraction membrane, a new method of flow injection (FI)-membrane solid phase microextraction (MSPME) on-line coupled to inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed for simultaneous determination of trace metals (Cu, Mn and Ni) in environmental water samples. The adsorption capacities of the alumina hollow fiber for Cu, Mn and Ni were found to be 6.6, 8.7 and 13.3 mg g(-1), respectively. With a preconcentration factor of 10, the limits of detection (LODs) for Cu, Mn and Ni were found to be 0.88, 0.61 and 0.38 ng mL(-1), respectively, and the relative standard deviations (RSDs) were ranging from 6.2 to 7.9% (n = 7, c = 10 ng mL(-1)). To validate the accuracy, the proposed method was applied to the analysis of certified reference material GSBZ50009-88 environmental water and the determined values are in good agreement with the certified values. The developed method was also employed for the analysis of Yangtze River water and East Lake water, and the recoveries for the spiked samples were in the range of 87.4-110.2%.  相似文献   

10.
A solid-phase extraction method combined with flow injection (FI) on-line flame atomic absorption spectrometry (FAAS) for the determination of cadmium and nickel in tobacco samples is presented. The 2-aminothiophenol functionalized Amberlite XAD-4 (AT-XAD) resin was synthesized by covalent coupling of the ligand with the copolymer through a methylene group. A minicolumn packed with AT-XAD was connected into the automated on-line preconcentration system. Elution of metal ions from minicolumn can be made with 0.50 mol L−1 hydrochloric acid solution. With a consumption of 21.0 mL of sample solution, detection limits (3 s) of 0.3 (Cd) and 0.8 μg L−1 (Ni) were achieved at a sample throughput of 18 h−1. Enrichment factors (EF) of 99 (cadmium) and 43 (nickel) were obtained compared with the slope of the linear portion of the calibration curves before and after preconcentration. The contents of Cd and Ni in a certified reference material (NIST 1570a, spinach leaves) determined by the present method was in good agreement with the certified value. The developed procedure was also successfully applied to the determination of Cd and Ni in local tobacco samples.  相似文献   

11.
A solid phase extraction procedure is proposed for simultaneous separation and preconcentration trace amounts of Cu(II) and Cd(II) using alumina coated with N'-{4-[4-{1-[4-(dimethylamino)phenyl]methylidene}-5-(4-H)oxazolone]phenyle}acetamide and determination by flame atomic absorption spectrometry. Using 0.1g of the sorbent, the metal ions were sorbed at pH 7 and recovered with 5.0 mL of 0.5 mol L(-1) HNO(3). It was found that extraction can be performed from the sample volumes of 2000 and 800 mL for Cu and Cd, respectively (preconcentration factors of 400 for Cu and 160 for Cd). Obtained sorption capacities for 1g sorbent were 8 mg Cu and 14 mg Cd. The linearity was maintained in the concentration range of 0.1 ng mL(-1) to 7.0 μg mL(-1) for Cu and 0.13 ng mL(-1) to 2.0 μg mL(-1) for Cd in the original solution. Eight replicate determinations of a mixture containing 1.0 μg mL(-1) each of the elements in the final solution gave relative standard deviation ±1.6 and ±1.3% for Cu and Cd, respectively. The detection limit was calculated as 0.06 and 0.05 ng mL(-1) for Cu and Cd, respectively. The proposed method was successfully applied to the determination trace amounts of Cu and Cd in the water and plant samples.  相似文献   

12.
A convenient method is described for monitoring Cd, Ni, Cu, and Pb at trace levels in drinking water samples. These metals are preconcentrated on a chelating solid-phase extraction disk and then determined by X-ray fluorescence spectrometry. The method tolerates a wide pH range (pH 6-14) and a large amount of alkaline and alkaline earth elements. The preconcentration factor is well over 1600, assuming a 1 L water sample volume. The limits of detection for Cd, Ni, Cu, and Pb are 3.8, 0.6, 0.4, and 0.3 ng/mL, respectively. These are well below the federal maximum contaminant level values, which are 5, 100, 1300, and 15 ng/mL, respectively. The proposed method has many advantages including ease of operation, multielement capability, nondestructiveness, high sensitivity, and relative cost efficiency. The solid-phase extraction step can be conducted in the field and then the disks can be mailed to a laboratory for the analysis, eliminating the cost of transporting large volumes of water samples. Furthermore, the color of the used extraction disk provides an initial estimate of the degree of contamination for some transition metals (for example, Ni and Cu). Thus, the overall cost for analysis of metals in drinking water can be minimized by implementing the method, and small water supply companies with limited budgets will be better able to comply with the Safe Drinking Water Act.  相似文献   

13.
A cloud point extraction procedure was presented for the preconcentration of copper, nickel and cobalt ions in various samples. After complexation with methyl-2-pyridylketone oxime (MPKO) in basic medium, analyte ions are quantitatively extracted to the phase rich in Triton X-114 following centrifugation. 1.0 mol L−1 HNO3 nitric acid in methanol was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The adopted concentrations for MPKO, Triton X-114 and HNO3, bath temperature, centrifuge rate and time were optimized. Detection limits (3 SDb/m) of 1.6, 2.1 and 1.9 ng mL−1 for Cu2+, Co2+ and Ni2+ along with preconcentration factors of 30 and for these ions and enrichment factor of 65, 58 and 67 for Cu2+, Ni2+ and Co2+, respectively. The high efficiency of cloud point extraction to carry out the determination of analytes in complex matrices was demonstrated. The proposed procedure was applied to the analysis of biological, natural and wastewater, soil and blood samples.  相似文献   

14.
A very simple and ligand-less cloud point extraction (CPE) methodology for the preconcentration of ultra-trace amounts of silver as a prior step to its determination by electrothermal atomic absorption spectrometry (ETAAS) has been developed. The method is based on the extraction of silver at pH 9 by using non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) without adding any chelating agent. Several important variables that affect the CPE efficiency and ETAAS signal were investigated and optimized. The preconcentration of 15 ml sample solution allowed us to achieve an enhancement factor of 60. The calibration graph using the preconcentration system was linear in the range of 5-100 ngl(-1) with a correlation coefficient of 0.9991. The lower limit of detection (3s) obtained in the optimal conditions was 1.2 ngl(-1). The relative standard deviation (R.S.D.) for eight replicate determinations at 30 ngl(-1) Ag level was 4.2%. The proposed method was successfully applied to the ultra-trace determination of silver in water samples.  相似文献   

15.
A simple, highly sensitive and environment-friendly method for the determination of trace amount of nickel ion in different matrices is proposed. In the preconcentration step, the nickel from 10 mL of an aqueous solution was extracted into 500 μL of ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6], containing PAN as complexing agent. Subsequently, the PAN complex was back-extracted into 250 μL of nitric acid solution, and 100 μL of it was analyzed by flow injection flame atomic absorption spectrometry (FI-FAAS). The main parameter influencing the extraction and determination of nickel, such as pH, concentration of PAN, extraction time and temperature, ionic strength, and concentration of stripping acid solution, were optimized. An enhancement factor of 40.2 was achieved with 25 mL sample. The limit of detection (LOD) and quantification obtained under the optimum conditions were 12.5 and 41.0 μg L?1, respectively. To validate the proposed methods two certified reference materials 681-I and BCR No. 288 were analyzed and the results were in good agreement with the certified values. The proposed method was successfully applied to determination of nickel in water samples, rice flour and black tea.  相似文献   

16.
Solidified floating organic drop microextraction (SFODME), combined with graphite furnace atomic absorption spectrometry (GFAAS) was proposed for simultaneous separation/enrichment and determination of trace amounts of nickel and cobalt in surface waters and sea water. 1-(2-Pyridylazo)-2-naphthol (PAN) was used as chelating agent. The main parameters affecting the performance of SFODME, such as pH, concentration of PAN, extraction time, stirring rate, extraction temperature, sample volume and nature of the solvent were optimized. Under the optimum experimental conditions, a good relative standard deviation for six determination of 20 ng l−1 of Co(II) and Ni(II) were 4.6 and 3.6%, respectively. An enrichment factor of 502 and 497 and detection limits of 0.4 and 0.3 ng l−1 for cobalt and nickel were obtained, respectively. The procedure was applied to tap water, well water, river water and sea water, and accuracy was assessed through the analysis of certified reference water or recovery experiments.  相似文献   

17.
The present paper outlines novel, simple and sensitive method for the determination of palladium by flame atomic absorption spectrometry (FAAS) after separation and preconcentration by cloud point extraction (CPE). The cloud point methodology was successfully applied for palladium determination by using new reagent 4-(2-naphthalenyl)thiozol-2yl azo chromotropic acid (NTACA) and hydrophobic ligand Triton X-114 as chelating agent and nonionic surfactant respectively in the water samples and alloys. The following parameters such as pH, concentration of the reagent and Triton X-114, equilibrating temperature and centrifuging time were evaluated and optimized to enhance the sensitivity and extraction efficiency of the proposed method. The preconcentration factor was found to be (50-fold) for 250 ml of water sample. Under optimum condition the detection limit was found as 0.067 ngml(-1) for palladium in various environmental matrices. The present method was applied for the determination of palladium in various water samples, alloys and the result shows good agreement with reported method and the recoveries are in the range of 96.7-99.4%.  相似文献   

18.
A solid phase extraction and graphite furnace atomic absorption spectrometry (GFAAS) for the determination of nickel, silver, cobalt, copper, cadmium and lead with MCI GEL CHP 20Y as sorbent was studied. Trace amounts of chromium, nickel, silver, cobalt, copper, cadmium and lead were reacted with 2-(2-quinolinil-azo)-4-methyl-1,3-dihydroxidobenzene (QAMDHB) followed by adsorption onto MCI GEL CHP 20Y solid phase extraction column, and 1.0molL(-1) HNO(3) was used as eluent. The metal ions in 300mL solution can be concentrated to 1.0mL, representing an enrichment factor of 300 was achieved. The recoveries of analytes at pH 8.0 with 1.0g of resin were greater than 95% without interference from alkaline, earth alkaline and some metal ions. When detected with graphite furnace atomic absorption spectrometry, the detection limits in the original samples were 1.4ngL(-1) for Cr(III), 1.0ngL(-1) for Ni(II), 0.85ngL(-1) for Ag(I), 1.2ngL(-1) for Co(II), 1.0ngL(-1) for Cu(II), 1.2ngL(-1) for Cd(II) and 1.3ngL(-1) for Pb(II). The validation of the procedure was performed by the analysis of the certified standard reference materials, and the presented procedure was applied to the determination of analytes in biological, water and soil samples with good results (recoveries range from 89 to 104%, and R.S.D.% lower than 3.2%. The results agreed with the standard value or reference method).  相似文献   

19.
A novel column solid phase extraction procedure was developed for the determination of lead, nickel, copper and manganese in various water samples by flame atomic absorption spectrometry (FAAS) after preconcentration on sodium bispiperdine-1,1'-carbotetrathioate (Na-BPCTT) supported by Amberlite XAD-7. The sorbed element was subsequently eluted with 1M nitric acid and the acid eluates are analysed by Flame atomic absorption spectrometry (FAAS). Various parameters such as pH, amount of adsorbent, eluent type and volume, flow-rate of the sample solution, volume of the sample solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH for the sorption of above mentioned metal ions was about 6.0+/-0.2. The loading capacity of adsorbent for Pb, Cu, Ni and Mn were found to 28, 26, 22 and 20x10(-6) g/mL, respectively. The recoveries of lead, copper, nickel and manganese under optimum conditions were found to be 96.7-99.2 at the 95% confident level. The limit of detection was 3.0, 3.2, 2.8 and 3.6x10(-6) g/mL for lead, copper, nickel and manganese, respectively by applying a preconcentration factor 50. The proposed enrichment method was applied for metal ions in various water samples. The results were obtained are good agreement with reported method.  相似文献   

20.
A cloud point extraction process using the nonionic surfactant Triton X-114 for extracting mercury from aqueous solutions was investigated. The method is based on the complexation reaction of Hg(II) with Thio-Michler's Ketone (TMK) and micelle-mediated extraction of the complex. The optimal extraction and reaction conditions (e.g., pH, reagent concentration, effect of time) were studied, and the analytical characteristics of the method (e.g., limit of detection, linear range) were obtained. Linearity was obeyed in the range of 5.0-80.0 ng mL(-1) of Hg(II) ion. The detection limit of the method was 0.83 ng mL(-1) of Hg(II) ion. The interference effect of some anions and cations was also tested. The method was applied to the determination of mercury in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏