首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
Native mass spectrometry was evaluated for the qualitative and semiquantitative analysis of composite mixtures of antibodies representing biopharmaceutical products coexpressed from single cells. We show that by using automated peak fitting of the ion signals in the native mass spectra, we can quantify the relative abundance of each of the antibodies present in mixtures, with an average accuracy of 3%, comparable to a cation exchange chromatography based approach performed in parallel. Moreover, using native mass spectrometry we were able to identify, separate, and quantify 9 antibodies present in a complex mixture of 10 antibodies, whereas this complexity could not be unraveled by cation exchange chromatography. Native mass spectrometry presents a valuable alternative to existing analytical methods for qualitative and semiquantitative profiling of biopharmaceutical products. It provides both the identity of each species in a mixture by mass determination and the relative abundance through comparison of relative ion signal intensities. Native mass spectrometry is a particularly effective tool for characterization of heterogeneous biopharmaceutical products such as bispecific antibodies and antibody mixtures.  相似文献   

2.
Mixtures of inorganic ions separated by capillary electrophoresis (CE) and ion exchange chromatography (IC) are detected by mass spectrometry (MS) using an ion spray atmospheric pressure ionization source. The selectable degree of ion-adduct declustering and molecular fragmentation in the MS interface region allows the system to be operated as an elemental analyzer or as a molecular detector suitable for oxidation state determinations. Both inorganic anions and cations (including alkalis, alkaline earths, transition metals, and lanthanides) are analyzed by CE-MS. A variety of CE separation buffers are evaluated for the cation analyses (e.g., creatinine, ammonium acetate, and tris[hydroxymethyl]aminomethane). Only one of the buffers (i.e., creatinine) can be used for CE-indirect UV detection. A CE capillary permanently coated with strong anion exchange sites and a pyromellitic acid buffer (suitable for indirect UV detection) is used for the inorganic anion separations. The coated column eliminates the need for buffer modifiers to reverse the flow in the capillary, which then reduces background noise and mass spectral complexity. The separation and detection of 13 inorganic anions are also accomplished by IC using an anion exchange column with a carbonate-bicarbonate mobile phase, on-line suppressed conductivity detection, and mass spectrometric detection.  相似文献   

3.
The number of biological/biomedical applications that require AMS to achieve their goals is increasing, and so is the need for a better understanding of the physical, morphological, and structural traits of high quality of AMS targets. The metrics of quality included color, hardness/texture, and appearance (photo and SEM), along with FT-IR, Raman, and powder X-ray diffraction spectra that correlate positively with reliable and intense ion currents and accuracy, precision, and sensitivity of fraction modern ( F m). Our previous method produced AMS targets of gray-colored iron-carbon materials (ICM) 20% of the time and of graphite-coated iron (GCI) 80% of the time. The ICM was hard, its FT-IR spectra lacked the sp (2) bond, its Raman spectra had no detectable G' band at 2700 cm (-1), and it had more iron carbide (Fe 3C) crystal than nanocrystalline graphite or graphitizable carbon (g-C). ICM produced low and variable ion current whereas the opposite was true for the graphitic GCI. Our optimized method produced AMS targets of graphite-coated iron powder (GCIP) 100% of the time. The GCIP shared some of the same properties as GCI in that both were black in color, both produced robust ion current consistently, their FT-IR spectra had the sp (2) bond, their Raman spectra had matching D, G, G', D +G, and D ' bands, and their XRD spectra showed matching crystal size. GCIP was a powder that was easy to tamp into AMS target holders that also facilitated high throughput. We concluded that AMS targets of GCIP were a mix of graphitizable carbon and Fe 3C crystal, because none of their spectra, FT-IR, Raman, or XRD, matched exactly those of the graphite standard. Nevertheless, AMS targets of GCIP consistently produced the strong, reliable, and reproducible ion currents for high-throughput AMS analysis (270 targets per skilled analyst/day) along with accurate and precise F m values.  相似文献   

4.
A method is described for the measurement of apparent zinc absorption in human nutrition studies. An enriched source of the stable isotope 67Zn was given to adult subjects together with a wheat cereal and the unabsorbed 67Zn measured in the feces. After drying, subsamples of the homogenized fecal material were ashed at 480 degrees C, purified for analysis by ion exchange chromatography, and the 64Zn/67Zn ratios determined by both fast atom bombardment mass spectrometry and thermal ionization quadrupole mass spectrometry. Good agreement was found between the two sets of results with mean precisions of approximately 0.5% for both techniques.  相似文献   

5.
Dual IBS (Ion Beam Sputtering) technique was used to fabricate NiO/NiFe bilayers. Various process conditions were examined to enhance the exchange field of the bilayer. Ion beam sputtering with an ion beam voltage above the threshold voltage and with the optimum ion beam current produced a fine-grained and smooth NiO film. This fine-grained surface followed by optimum etching exhibited an enhanced exchange field of 100 Oe. Growing NiO films were ion bombarded with a secondary ion-beam source having various beam voltages. The texture, surface roughness and grain size of the NiO films changed due to the ion bombardment; however, the grain size and/or surface roughness rather than texture was found to be responsible for controlling the exchange coupling. Furthermore, it was demonstrated that an optimum etching time of the NiO film prior to the depositing of NiFe for a large exchange field exists. With this optimum etching of the NiO film, surface segregated impurities could be eliminated without deteriorating the surface unnecessarily. Exchange fields and coercivities of the NiO/NiFe bilayers were measured with a MOKE (Magneto–Optic Kerr Effect) hysteresis looper and the surface properties of NiO films were examined with an AFM (Atomic Force Microscope) and an AES (Auger Electron Spectroscope).  相似文献   

6.
Biological and biomedical applications of accelerator mass spectrometry (AMS) use isotope ratio mass spectrometry to quantify minute amounts of long-lived radioisotopes such as (14)C. AMS target preparation involves first the oxidation of carbon (in sample of interest) to CO 2 and second the reduction of CO 2 to filamentous, fluffy, fuzzy, or firm graphite-like substances that coat a -400-mesh spherical iron powder (-400MSIP) catalyst. Until now, the quality of AMS targets has been variable; consequently, they often failed to produce robust ion currents that are required for reliable, accurate, precise, and high-throughput AMS for biological/biomedical applications. Therefore, we described our optimized method for reduction of CO 2 to high-quality uniform AMS targets whose morphology we visualized using scanning electron microscope pictures. Key features of our optimized method were to reduce CO 2 (from a sample of interest that provided 1 mg of C) using 100 +/- 1.3 mg of Zn dust, 5 +/- 0.4 mg of -400MSIP, and a reduction temperature of 500 degrees C for 3 h. The thermodynamics of our optimized method were more favorable for production of graphite-coated iron powders (GCIP) than those of previous methods. All AMS targets from our optimized method were of 100% GCIP, the graphitization yield exceeded 90%, and delta (13)C was -17.9 +/- 0.3 per thousand. The GCIP reliably produced strong (12)C (-) currents and accurate and precise F m values. The observed F m value for oxalic acid II NIST SRM deviated from its accepted F m value of 1.3407 by only 0.0003 +/- 0.0027 (mean +/- SE, n = 32), limit of detection of (14)C was 0.04 amol, and limit of quantification was 0.07 amol, and a skilled analyst can prepare as many as 270 AMS targets per day. More information on the physical (hardness/color), morphological (SEMs), and structural (FT-IR, Raman, XRD spectra) characteristics of our AMS targets that determine accurate, precise, and high-hroughput AMS measurement are in the companion paper.  相似文献   

7.
The measurement of delta15N values of inorganic nitrogen species is an important analytical tool to trace nitrogen species in order to understand nitrogen cycling in aquatic systems. Nitrogen isotope analysis of freshwater ammonium has, however, been hindered by the lack of a simple and reliable technique to measure delta15N values at natural abundance levels. We present a simple and rapid method to concentrate ammonium from freshwater samples for on-line N-isotope ratio determination. Ammonium is collected by adsorption on N-free cation exchange resins. The dried N-loaded exchange resin is then directly combusted to produce N2 gas for subsequent delta15N analysis. The method was evaluated with simulated freshwater solutions containing varying amounts of standard NH4+-N (delta15N = 2.1 per thousand) and potentially interfering inorganic and organic compounds. In general, the cation exchange resin method gives accurate and reproducible delta15N values (sigma1 < 0.3 per thousand; n = 10). Because of adsorption interference, high concentrations of cations in solution may cause ammonium loss but do not result in measurable isotope fractionation. Replicate extractions of the ammonium standard added to water collected from four Swiss lakes demonstrate the good performance of this method when applied to low ionic strength natural water samples with modest concentrations of dissolved organic nitrogen.  相似文献   

8.
We have developed a new technique for quantifying methionine sulfoxide (MetSO) in protein to assess levels of oxidative stress in physiological systems. In this procedure, samples are hydrolyzed with methanesulfonic acid (MSA) in order to avoid the conversion of MetSO to methionine (Met) that occurs during hydrolysis of protein in HCl. The hydrolysate is fractionated on a cation exchange column to remove the nonvolatile MSA from amino acids, and the amino acids are then derivatized as their trimethylsilyl esters for analysis by selected ion monitoring-gas chromatography/mass spectrometry. The limit of detection of the assay is 200 pmol of MetSO per analysis, and the interassay coefficient of variation is 5.8%. Compared to current methods, the SIM-GC/MS assay avoids the potential for conversion of Met to MetSO during sample preparation, requires less sample preparation time, has lower variability, and uses mass spectrometry for sensitive and specific analyte detection.  相似文献   

9.
N Klaus 《Vacuum》1985,35(3):131-135
A dual primary beam gun for secondary ion mass spectroscopy (SIMS) is presented. The beam source produces, without any mechanical change, either an ion beam or a neutral beam generated by resonant charge transfer. The energy of the ion beam ranges from less than 1 keV up to 3.0 keV at beam currents from 10?11 A to 1×10?6A. The diameter of the ion beam can be focused additionally from 3.0 mm down to 0.4 mm FWHM. The particle density and the homogeneity of the neutral beam is of the same order as that of the ion beam. SIMS analysis of solid surfaces is possible without any restrictions arising from the conductivity of the specimen.  相似文献   

10.
Dai J  Shieh CH  Sheng QH  Zhou H  Zeng R 《Analytical chemistry》2005,77(18):5793-5799
A novel integrated multidimensional liquid chromatography (IMDL) method is demonstrated for the separation of peptide mixtures by two-dimensional HPLC coupled with ion trap mass spectrometry. The method uses an integrated column, containing both strong cation exchange and reversed-phase sections for two-dimensional liquid chromatography. The peptide mixture was fractionated by a pH step using a series of pH buffers, followed by reversed-phase chromatography. Since no salt was used during separation, the integrated multidimensional liquid chromatography can be directly connected to mass spectrometry for peptide analysis. The pH buffers were injected from an autosampler, and the entire process can be carried out on a one-dimensional liquid chromatography system. In a single analysis, the IMDL system, coupled with linear ion trap mass spectrometry, identified more than 2000 proteins in mouse liver. The peptides were eluted according to their pI distribution. The resolution of the pH fractionation is approximately 0.5 pH unit. The method has low overlapping across pH fractions, good resolution of peptide mixture, and good correlation of peptide pIs with pH steps. This method provides a technique for large-scale protein identification using existing one-dimensional HPLC systems.  相似文献   

11.
We present a new elemental analysis (EA) technique for organic species (CHNO) that allows fast on-line analysis (10 s) and reduces the required sample size to approximately 1 ng, approximately 6 orders of magnitude less than standard techniques. The composition of the analyzed samples is approximated by the average elemental composition of the ions from high-resolution electron ionization (EI) mass spectra. EA of organic species can be performed on organic/inorganic mixtures. Elemental ratios for the total organic mass, such as oxygen/carbon (O/C), hydrogen/carbon (H/C), and nitrogen/carbon (N/C), in addition to the organic mass to organic carbon ratio (OM/OC), can be determined. As deviations between the molecular and the ionic composition can appear due to chemical influences on the ion fragmentation processes, the method was evaluated and calibrated using spectra from 20 compounds from the NIST database and from 35 laboratory standards sampled with the high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS). The analysis of AMS (NIST) spectra indicates that quantification of O/C is possible with an error (average absolute value of the relative error) of 30% (17%) for individual species. Precision is much better than accuracy at +/-5% in the absence of air for AMS data. AMS OM/OC has an average error of 5%. Additional calibration is recommended for types of species very different from those analyzed here. EA was applied to organic mixtures and ambient aerosols (sampled at 20 s from aircraft). The technique is also applicable to other EI-HRMS measurements such as direct injection MS.  相似文献   

12.
A buckminsterfullerene (C60)-based primary ion beam system has been developed for routine application in TOF-SIMS analysis of organic materials. The ion beam system is described, and its performance is characterized. Nanoamp beam currents of C60+ are obtainable in continuous current mode. C60(2+) can be obtained in pulsed mode. At 10 keV, the beam can be focused to less than 3 microm with 0.1 nA currents. TOF-SIMS studies of a series of molecular solids and a number of polymer systems in monolayer and thick film forms are reported. Very significant enhancement of secondary ion yields, particularly at higher mass, were observed using 10-keV C60+ for all samples other than PTFE, as compared to those observed from 10 keV Ga+ primary ions. Three materials (PS2000, Irganox 1010, PET) were studied in detail to investigate primary ion-induced disappearance (damage) cross sections to determine the increase in secondary ion formation efficiency. The C60 disappearance cross sections observed from monolayer film PS2000 and self-supporting PET film are close to those observed from Ga+. The resulting C60 efficiencies are 30-100 times those observed from gallium. The cross sections observed from C60 bombardment of multilayer molecular solids are approximately 100 times less, such that essentially zero damage sputtering is possible. The resulting efficiencies are > 10(3) greater than from gallium. It is also shown that C60 primary ions do not generate any more low-mass fragments than any other ion beam system does. C60 is shown to be a very favorable ion beam system for TOF-SIMS, delivering high yield, close to 10% total yield, favoring high-mass ions, and on thick samples, offering the possibility of analysis well beyond the static limit.  相似文献   

13.
The isotope effects of gadolinium in Gd-EDTA ligand exchange system were studied by means of ion exchange chromatography. The separation coefficients of gadolinium isotopes, epsilon, and the local enrichment factors, beta, were calculated from the observed isotopic ratios at the front and rear boundaries of the gadolinium adsorption band. Clear mass independent anomalies were observed in the isotope effects of 155Gd and 157Gd. The relation between the isotope effects of gadolinium isotopes, studied by the three-isotope plot and the separation coefficient methods, and the mass of gadolinium isotopes was found to be related to the change in the mean square radius of the nuclear charge distribution parameter, (r2), of these isotopes, which suggests that the nucleus shape and size highly affect the gadolinium isotope effects in chemical exchange reactions.  相似文献   

14.
The removal of chromium from aqueous solution by an ion exchange resin is described. Ion exchange resins 1200H, 1500H and IRN97H show a remarkable increase in sorption capacity for chromium, compared to other adsorbents. The adsorption process, which is pH dependent show maximum removal of chromium in the pH range 2-6 for an initial chromium concentration of 10mg/l. The metal ion adsorption obeyed linear, Langmuir and Freundlich isotherms. The adsorption of chromium on these cation exchange resins follows first-order reversible kinetics and pseudo-first-order kinetics. The intraparticle diffusion of chromium on ion exchange resins represents the rate-limiting step. The uptake of chromium by the ion exchange resins was reversible and thus have good potential for the removal/recovery of chromium from aqueous solutions. We conclude that such ion exchange resins can be used for the efficient removal of chromium from water and wastewater.  相似文献   

15.
This paper describes the application of a novel, practical approach for isolation of individual compounds from complex organic matrices for natural abundance radiocarbon measurement. This is achieved through the use of automated preparative capillary gas chromatography (PCGC) to separate and recover sufficient quantities of individual target compounds for (14)C analysis by accelerator mass spectrometry (AMS). We developed and tested this approach using a suite of samples (plant lipids, petroleums) whose ages spanned the (14)C time scale and which contained a variety of compound types (fatty acids, sterols, hydrocarbons). Comparison of individual compound and bulk radiocarbon signatures for the isotopically homogeneous samples studied revealed that Δ(14)C values generally agreed well (±10%). Background contamination was assessed at each stage of the isolation procedure, and incomplete solvent removal prior to combustion was the only significant source of additional carbon. Isotope fractionation was addressed through compound-specific stable carbon isotopic analyses. Fractionation of isotopes during isolation of individual compounds was minimal (<5‰ for δ(13)C), provided the entire peak was collected during PCGC. Trapping of partially coeluting peaks did cause errors, and these results highlight the importance of conducting stable carbon isotopic measurements of each trapped compound in concert with AMS for reliable radiocarbon measurements. The addition of carbon accompanying derivatization of functionalized compounds (e.g., fatty acids and sterols) prior to chromatographic separation represents a further source of potential error. This contribution can be removed using a simple isotopic mass balance approach. Based on these preliminary results, the PCGC-based approach holds promise for accurately determining (14)C ages on compounds specific to a given source within complex, heterogeneous samples.  相似文献   

16.
We report a novel method for measurement of the oxygen isotopic composition (18O/16O) of nitrate (NO3-) from both seawater and freshwater. The denitrifier method, based on the isotope ratio analysis of nitrous oxide generated from sample nitrate by cultured denitrifying bacteria, has been described elsewhere for its use in nitrogen isotope ratio (15N/14N) analysis of nitrate. (1) Here, we address the additional issues associated with 18O/16O analysis of nitrate by this approach, which include (1) the oxygen isotopic difference between the nitrate sample and the N20 analyte due to isotopic fractionation associated with the loss of oxygen atoms from nitrate and (2) the exchange of oxygen atoms with water during the conversion of nitrate to N2O. Experiments with 18O-labeled water indicate that water exchange contributes less than 10%, and frequently less than 3%, of the oxygen atoms in the N20 product for Pseudomonas aureofaciens. In addition, both oxygen isotope fractionation and oxygen atom exchange are consistent within a given batch of analyses. The analysis of appropriate isotopic reference materials can thus be used to correct the measured 18O/16O ratios of samples for both effects. This is the first method tested for 18O/16O analysis of nitrate in seawater. Benefits of this method, relative to published freshwater methods, include higher sensitivity (tested down to 10 nmol and 1 microM NO3-), lack of interference by other solutes, and ease of sample preparation.  相似文献   

17.
We have developed a rapid and simple measurement system for both content and stable isotopic compositions (13C and 18O) of atmospheric CO, using continuous-flow isotope ratio mass spectrometry by simultaneously monitoring the CO+ ion currents at masses 28, 29, and 30. The analytical system consisted sequentially of a sample trapping port (liquid nitrogen temperature silica gel and molecular sieve 5A), a gas dryer, a CO purification column (molecular sieve 5A), a cryofocusing unit, and a final purification column using a GC capillary. Analytical precision of 0.2 per thousand for 13C and 0.4 per thousand for 18O can be realized for samples that contain as little as 300 pmol of CO within 40 min for one sample analysis. Analytical blanks associated with the method are less than 1 pmol. The extent of analytical error in delta13C due to mass-independent fractionation of oxygen in natural CO is estimated to be less than 0.3 per thousand. Based on this system, we report herein a kinetic isotopic effect during CO consumption in soil.  相似文献   

18.
We measured the Ni isotopic composition of metal from a variety of meteorite groups to search for variations in the 60Ni abundance from the decay of the short-lived nuclide 60Fe (t(1/2) = 1.49 My) and for possible nucleosynthetic effects in the other stable isotopes of Ni. We developed a high-yield Ni separation procedure based on a combination of anion and cation exchange chromatography. Nickel isotopes were measured on a single-focusing, multicollector, inductively coupled mass spectrometer (MC-ICPMS). The external precision on the mass-bias-corrected 60Ni/58Ni ratio (+/-0.15 epsilon; 2sigma) is comparable to similar studies using double-focusing MC-ICPMS. We report the first high-precision data for 64Ni, the least abundant Ni isotope, obtained via MC-ICPMS. The external precision on the mass-bias-corrected 64Ni/58Ni ratio (+/-1.5 epsilon; 2sigma) is better than previous studies using thermal ionization mass spectrometry. No resolvable excesses relative to a terrestrial standard in the mass-bias-corrected 60Ni/58Ni ratio were detected in any meteoritic metal samples. However, resolvable deficits in this ratio were measured in the metal from several unequilibrated chondrites, implying a 60Fe/56Fe ratio of approximately 1 x 10(-6) at the time of Fe/Ni fractionation in chondritic metal. A 60Fe/56Fe ratio of (4.6 +/- 3.3) x 10(-7) is inferred at the time of Fe/Ni fractionation on the parent bodies of magmatic iron meteorites and pallasites. No clearly resolvable non-mass-dependent anomalies were detected in the other stable isotopes of Ni in the samples investigated here, indicating that the Ni isotopic composition in the early solar system was homogeneous (at least at the level of precision reported here) at the time of meteoritic metal formation.  相似文献   

19.
Low temperature photoluminescence measurements were carried out for acceptor-doped GaAs. Impurities were introduced by doping during molecular beam epitaxy (MBE) or liquid phase epitaxy (LPE) growth or by ion beam impingement into substrates using mass-separated ions. In the case of carbon incorporation, doping of mass-separated C+ ions using a low energy ion beam was carried out during MBE growth of GaAs. Results revealed that just below the band edge emissions a large number of novel strong emissions are produced. These emissions were found to be totally missing in specimens prepared by conventional methods. Dual incorporation of acceptor and donor impurities indicated that these emissions are easily quenched by an extremely small amount of donor atoms, which is a principal reason for the absence of these emissions in previous samples. Most of these novel emissions were also obtained in InP, implying that these observations are ubiquitously established in the whole range of III–V compound semiconductors. It was concluded that for the comprehensive understanding of impurity properties in semiconductors, mass-separated impurity introduction into ultra pure substrates is essential to avoid this strong optical (and corresponding electrical) compensation effect induced by oppositely charged impurities. Taking this conclusion into consideration, we emphasize that the optical properties of doped semiconductors should be totally re-examined in a more detailed and systematic manner.  相似文献   

20.
The analysis of the stable nitrogen isotope compositions of individual amino acid stereoisomers through the use of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is presented. Nitrogen isotopic compositions of single amino acids or of their enantiomers is possible without the labor-intensive and time-consuming preparative-scale chromatographic procedures required for conventional stable isotope analysis. Following hydrolysis and derivatization, single-component isotope analysis is accomplished on nanomole quantities of each of the stereoisomers of an amino acid, utilizing the effluent stream of gas chromatographic separation. Nitrogen isotope fractionation is minimal during acylation of the amino acid, with no additional nitrogen being added stoichiometrically to the derivative. Thus, the isotopic composition of the nitrogen in the derivative is that of the original compound. Replicate stable nitrogen isotope analyses of 11 amino acids, and their trifluoroacetyl (TFA)/isopropyl (IP) ester derivatives, determined by both conventional isotope ratio mass spectrometry (IRMS) and GC/C/IRMS, indicate that the GC procedure is highly reproducible (standard deviations typically 0.3-0.4‰) and that isotopic differences between the amino acid and its TFA/IP derivative are, in general, less than 0.5‰.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号