首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Because of severe hemolysis, especially on producing pulsatile flow by changing the rotating speed of the impellers, the traditional centrifugal pump was rarely used for long-term support of the failing heart. We therefore developed a motor driven pulsatile implantable impeller pump. The pulsatility was achieved by changing the rotating speed via introducing a square waveform voltage into the motor coil. The impeller vane was designed to have both radial and axial curves according to the stream surface and stream lines to reduce the thrombosis and hemolysis. Nine calves weighing 80 to 100 kg were used. With the calves under endotracheal general anesthesia, left posterolateral thoracotomy was performed to connect the inflow tube with the left atrial appendage and to anastomose the outflow tube with the descending aorta. The calves usually awoke and stood up within hours after discontinuation of anesthetics. Within 7 days, continuous monitoring of electrocardiogram, systemic and pulmonary arterial pressures, and central venous pressure were performed to adjust the pump flow to 40% to 50% of the cardiac output. During the survival of 4 to 54 days (mean 16.3 +/- 19.3 days with two calves surviving longer than 1 month), no significant deterioration of liver or renal function was noted. Because of bleeding, hemoglobin reduced from 11.4 +/- 1.8 to 9.0 +/- 1.3 g/dl, and the hematocrit decreased from 34.5 +/- 4.7 to 26.7 +/- 4.6%. No significant changes of free hemoglobin were noted. In our results, the device revealed competent pulsatile function without severe blood damage or organ dysfunction.  相似文献   

2.
A centrifugal pump with an impeller (Nikkiso Centrifugal Pump, Model HPM15; Nikkiso Co. Ltd.) was applied to cardiopulmonary bypass (CPB) in 14 patients who underwent elective coronary artery bypass grafting. Serum hemoglobin level, platelet count, and serum beta-thromboglobulin (beta TG) level were measured during CPB. The results were compared with those obtained in a comparative roller pump (RP) group (n = 10). There was no difference in the time on CPB between the NP (109 min) and RP (121 min) groups. The serum beta TG level (ng/ml) was lower in the NP group than in the RP group (obtained 90 min after the initiation of CPB). The plasma-free hemoglobin level also was lower in the NP group than in the RP group (obtained 90 min after the initiation of CPB, 120 min after the initiation of CPB, immediately after the termination of CPB, 3 h after termination of CPB; p < 0.01). There was no significant difference in platelet depletion. The HPM15 pump showed excellent hemodynamic performance with less blood trauma compared with the roller pump in its clinical application to open heart surgery.  相似文献   

3.
Right ventricular (RV) function is a limiting factor in maintaining systemic circulation with circulatory assist. There is, however, no easy way to institute RV assist, such as the intraarterial axial flow pump (Hemopump) used for left heart assist. In this study, the feasibility and hemodynamic effect of intravenous use of an axial flow pump was examined. A pump system was developed with an outflow cannula and an impeller that were newly designed for intravenous insertion with a Hemopump driving system. The pump system characteristics using goat blood at a hematocrit of 26% indicated that maximum flow at a pressure differential against 40 mmHg is 3.2 l/min at a pump speed of 28,000 rpm. The pump was tested in adult goats by intravenous insertion through a 14 mm, low porosity graft anastomosed to the infrarenal inferior vena cava. The pump was advanced until the tip of the cannula was positioned at the main pulmonary artery, using balloon catheter guidance under fluoroscopy. RV assistance was evaluated by pressure tracing, and aortic flow (AF) measured by electromagnetic flowmeter under 1) induced pulmonary stenosis (PS), and 2) electrically induced ventricular fibrillation (VF) in combination with left heart assist. Under PS, right atrial pressure decreased from 11 to 2 mmHg and AF increased from 1.0 to 4.1 l/min after initiation of the pump. Under VF, AF and aortic pressure were 2.6 l/min and 78 mmHg, respectively, with left ventricular assist. After initiation of the pump, they increased to 4.0 l/min and 98 mmHg, respectively. In chronic experiments using three adults goats for up to 48 hr, levels of plasma hemoglobin and platelet counts were maintained within an acceptable range. There was no prominent damage to the hearts. These data suggest that an axial flow pump introduced by an intravenous approach without thoracotomy is feasible and provides sufficient right heart assist.  相似文献   

4.
Palliative care was initiated in Italy towards the end of the 1970s, mainly through the efforts of Professor Ventafridda and his colleagues. This article describes some of the most important steps made in this country to gain widespread acceptance for the principles and practice of palliative care. After about 15 years the Italian situation is still confusing. While some Regions have made progress, others are far from reaching even minimal goals. The efforts of many charities and of the Italian Society for Palliative Care and the Italian School for Palliative Medicine, have been huge, but still not sufficient to promote widespread involvement of the National Health Authorities. In the absence of clear Regional and central laws, the recent changes in the Italian health system combined with increasing financial difficulties threaten the advances already made.  相似文献   

5.
An important consideration for clinical application of rotary blood pump based ventricular assist is the avoidance of ventricular collapse due to excessive operating speed. Because healthy animals do not typically demonstrate this phenomenon, it is difficult to evaluate control algorithms for avoiding suction in vivo. An acute hemodynamic study was thus conducted to determine the conditions under which suction could be induced. A 70 kg calf was implanted with an axial flow assist device (Nimbus/UoP IVAS; Nimbus Inc., Rancho Cordova, CA) cannulated from the left ventricular apex to ascending aorta. On initiation of pump operation, several vasoactive interventions were performed to alter preload, afterload, and contractility of the left ventricle. Initially, dobutamine increased contractility and heart rate ([HR] = 139; baseline = 70), but ventricular collapse was not achievable, even at the maximal pump speed of 15,000 rpm. Norepinephrine decreased HR (HR = 60), increased contractility, and increased systemic vascular resistance ([SVR] = 24; baseline = 15), resulting in ventricular collapse at a pump speed of 14,000 rpm. Isoproterenol (beta agonist) increased HR (HR = 103) and decreased SVR (SVR = 12), but ventricular collapse was not achieved. Inferior vena cava occlusion reduced preload, and ventricular collapse was achieved at speeds as low as 11,000 rpm. Esmolol (beta1 antagonist) decreased HR (HR = 55) and contractility, and ventricular collapse was achieved at 11,500 rpm. Episodes of ventricular collapse were characterized initially by the pump output exceeding the venous return and the aortic valve remaining closed throughout the cardiac cycle. If continued, the mitral valve would remain open throughout the cardiac cycle. Using these unique states of the mitral and aortic valves, the onset of ventricular collapse could reliably be identified. It is hoped that the ability to detect the onset of ventricular collapse, rather than the event itself, will assist in the development and the evaluation of control algorithms for rotary ventricular assist devices.  相似文献   

6.
Screening with mammography in order to detect early curable breast cancer has been widely used during the last 2-3 decades. Especially an overview of 4 randomised trials in Sweden has shown a convincing short-term relative reduction of the breast cancer mortality while the long-term absolute effect on this mortality has been impossible to study due to screening of the control groups after some years. There is, however, rather general consensus about the value of screening in women above 50 years of age whereas screening in the age group 40-49 is still controversial due to the low rate of mammographically demonstrable cancers and the high rate of recalls for supplementary mammography, clinical examinations and biopsies in relation to cancers found. Recent follow-up of the pooled Swedish randomised trials have shown an about 20% almost significant reduction of the breast cancer mortality in women aged 40-49 at randomisation but the design of these trials does not allow an adequate estimation of the extra benefit obtained by starting periodical screening at age 40 instead of at age 50. The author proposes that screening in the age group 40-49 should be regarded as experimental and subject to proper randomised trials of a type on-going in UK and planned within UICC.  相似文献   

7.
A flow rate estimating method was investigated for a centrifugal blood pump developed in our institute. The estimated flow rate was determined by the power consumption, the rotating speed of the motor, and the hematocrit value. The power consumption and the rotating speed of the motor were measured with a wattmeter. The examinations were performed in a closed mock loop filled with goat blood with hematocrit values of 21.5%, 28%, 34%, and 42%. Measured values of blood viscosity were 2.47, 3.09, 3.71, and 5.07 mPa.s at a share rate of 37.5/s, respectively. A linear correlation between the power consumption and the pump flow rate was observed in all hematocrit values. But variations in hematocrit caused a difference in the flow rate up to 1.1 L/min at the same power consumption and rotating speed. Effects of blood viscosity on the flow estimation were corrected by the hematocrit value. The value of the coefficient of determination, R2, between the estimated flow rate and the measured flow rate was 0.988. These results may indicate that the flow estimating method calculated by the power consumption of the motor, the rotating speed, and the hematocrit value is useful in the clinical situation.  相似文献   

8.
9.
刘旺荣 《黄金》2004,25(7):25-27
在矿石的选冶流程中,泵类起着输送各种流体的作用。它直接影响流程的顺畅与稳定,其中泵类过流材料、密封形式、联轴器的选择尤为关键。  相似文献   

10.
某油田电泵井J55油管外螺纹处发生腐蚀穿孔失效.从理化性能、腐蚀产物、微生物分析等方面进行了系统分析,结果表明:J55油管金相组织和成分均正常,C02腐蚀不是螺纹腐蚀刺漏的主要原因,硫酸盐还原菌(SRB)、腐生菌(TGB)和铁细菌(FEB)微生物腐蚀是导致螺纹腐蚀穿孔失效的主要原因.  相似文献   

11.
采用基于气泡聚并和破碎机理的群体平衡(PBM-MUSIG)模型,对双层半圆管盘式涡轮桨搅拌槽内的气液分散特性进行了数值模拟;考察了不同通气量和操作转速下气液搅拌槽内流体流动,局部气含率和气泡尺寸的分布规律.模拟结果表明:通气工况下搅拌槽内的液相流场具有双循环流动形式;采用PBM-MUSIG模型预测的局部气含率分布与文献实验数据吻合较好;搅拌槽内气泡尺寸随转速增加而减小,随气量增加而增大;桨叶排出流区域内气泡尺寸较小,近壁区和循环区内气泡尺寸较大.  相似文献   

12.
13.
Clotrimazole (CLT), an antimycotic drug, has been shown to inhibit proliferation of normal and cancer cell lines and its systemic use as a new tool in the treatment of proliferative disorders is presently under scrutiny (Benzaquen, L. R., Brugnara, C., Byers, H. R., Gattoni-Celli, S., and Halperin, J. A. (1995) Nature Med. 1, 534-540). The action of CLT is thought to involve depletion of intracellular Ca2+ stores but the underlying mechanism has not been defined. The present study utilized membrane vesicles of rabbit cardiac sarcoplasmic reticulum (SR) to determine the mechanism by which CLT depletes intracellular Ca2+ stores. The results revealed a strong, concentration-dependent inhibitory action of CLT on the ATP-energized Ca2+ uptake activity of SR (50% inhibition with approximately 35 microM CLT). The inhibition was of rapid onset (manifested in <15 s), and was accompanied by a 7-fold decrease in the apparent affinity of the SR Ca2+-ATPase for Ca2+ and a minor decrement in the enzyme's apparent affinity toward ATP. Exposure of SR to CLT in the absence or presence of Ca2+ resulted in irreversible inhibition of Ca2+ uptake demonstrating that the Ca2+-bound and Ca2+-free conformations of the Ca2+-ATPase are CLT-sensitive. Introduction of CLT to the reaction medium subsequent to induction of enzyme turnover with Ca2+ and ATP resulted in instantaneous cessation of Ca2+ transport indicating that an intermediate enzyme species generated during turnover undergoes rapid inactivation by CLT. The inhibition of Ca2+ uptake by CLT was accompanied by inhibition of Ca2+-stimulated ATP hydrolysis and Ca2+-induced phosphoenzyme intermediate formation from ATP in the ATPase catalytic cycle. Phosphorylation of the Ca2+-deprived enzyme with Pi in the reverse direction of catalytic cycle and Ca2+ release from Ca2+-preloaded SR vesicles were unaffected by CLT. It is concluded that CLT depletes intracellular Ca2+ stores by inhibiting Ca2+ sequestration by the Ca2+-ATPase. The mechanism of ATPase inhibition involves a drug-induced alteration in the Ca2+-binding site(s) resulting in paralysis of the enzyme's catalytic and ion transport cycle. CLT (50 microM) caused marked depression of contractile function in isolated perfused, electrically paced rabbit heart preparations. The contractile function recovered gradually following withdrawal of CLT from the perfusate indicating the existence of mechanisms in the intact cell to inactivate, metabolize, or clear CLT from its target site.  相似文献   

14.
Original studies leading to the gravitational model of pulmonary blood flow and contemporary studies showing gravity-independent perfusion differ in the recent use of laboratory animals instead of humans. We explored the distribution of pulmonary blood flow in baboons because their anatomy, serial distribution of vascular resistances, and hemodynamic responses to hypoxia are similar to those of humans. Four baboons were anesthetized with ketamine, intubated, and mechanically ventilated. Different colors of fluorescent microspheres were given intravenously while the animals were in the supine, prone, upright (repeated), and head-down (repeated) postures. The animals were killed, and their lungs were excised, dried, and diced into approximately 2-cm3 pieces with the spatial coordinates recorded for each piece. Regional blood flow was determined for each posture from the fluorescent signals of each piece. Perfusion heterogeneity was greatest in the upright posture and least when prone. Using multiple-stepwise regression, we estimate that 7, 5, and 25% of perfusion heterogeneity is due to gravity in the supine, prone, and upright postures, respectively. Although important, gravity is not the predominant determinant of pulmonary perfusion heterogeneity in upright primates. Because of anatomic similarities, the same may be true for humans.  相似文献   

15.
16.
Mechanisms of drug resistance in Campylobacter jejuni were investigated. Mutant strains 34PEFr, which was resistant to pefloxacin (128-fold increase in the MIC), and 34CTXr, which was resistant to cefotaxime (32-fold increase in the MIC) and which was derived from the susceptible parent 34s, were obtained by serial passages on pefloxacin and cefotaxime gradient plates, respectively. Both mutants showed cross-resistance to erythromycin, chloramphenicol, tetracycline, beta-lactams, and quinolones. While the quinolone resistance of strain PEFr could be explained by a mutation at codon 86 of the gyrA gene, the multidrug resistance phenotype of both strains was further investigated. Accumulation of pefloxacin, ciprofloxacin, and minocycline was measured by fluorometry and was found to be lower in the mutant strains than in the parent strain. Preincubation of the cells with carbonyl cyanide m-chlorophenylhydrazone, however, completely abolished this difference. Analysis by sodium dodecyl sulfate-polyacrylamide gel electrophoresis of outer membrane preparations from both mutant strains showed overexpression of two proteins of 55 and 39 kDa which were absent from the outer membranes of the wild-type strain. These results indicate that in C. jejuni 34PEFr and 34CTXr, multidrug resistance is associated with an efflux system with a broad specificity.  相似文献   

17.
采用粒子图像测速技术(PIV),对直径为0.19 m的三层组合桨(HEDT+2WH)搅拌槽(直径为0.48 m)内的流场进行了实验研究,并利用标准k-ε模型对相应的流动特性进行了数值模拟.实验结果表明:通过改变层间距、顶层桨的浸没深度及上两层桨的操作方式可以得到4种不同流型,每种流型内循环结构的数目各不相同;上两层桨下压式操作时,流场的循环结构最少,只有两个;高速区和高能量区的分布相同,都位于各个桨叶的射流区内,且底桨射流区内的速度值和湍流动能值都大于上两层桨.模拟结果表明:标准k-ε模型对流场的预测较为准确,但对于有5个循环结构的流型模拟误差较大;湍流动能分布型式的模拟值与PⅣ实验结果吻合较好,但数值偏低,表明标准k-ε模型在预测复杂流型时需要改进;功率准数的模拟值与实验值基本一致.  相似文献   

18.
PURPOSE: To compare the magnetic resonance (MR) imaging findings of primary hepatocellular carcinoma (HCC) in cirrhotic versus noncirrhotic livers. MATERIALS AND METHODS: MR images in 36 patients with HCC (30 men and she women aged 42-84 years [mean age, 65 years]) were retrospectively reviewed. The number and size of hepatic lesions were assessed. Lesion margins were categorized as well circumscribed or ill defined. The presence of a capsule, intratumoral high signal intensity on T1-weighted MR images, and a stellate scar were determined. RESULTS: Eleven (31%) patients had MR imaging evidence of cirrhosis, and 25 (69%) did not: Lesions in cirrhotic livers differed significantly from those in noncirrhotic livers in terms of size (22 cm2 vs 99 cm2, P < .05), frequency of a solitary lesion (27% vs 72%, P < .05), and frequency of a central scar (6% vs 50%, P < .05). There was no difference between the cirrhotic and noncirrhotic livers with regard to tumor margin, intratumoral high signal intensity on T1-weighted images, or tumor capsule. CONCLUSION: Differences exist in the MR imaging appearance of HCC between patients with and those without cirrhosis, although there is overlap of imaging findings.  相似文献   

19.
We applied two different flow visualization techniques to obtain detailed information on the inside flow of the diaphragm blood pump of our electrohydraulic total artificial heart system to determine the optimum washout effect that would result in better antithrombogenicity. Major orifice directions of the inflow and outflow Bjork-Shiley valves of the left blood pump were independently changed to create 17 varied patterns. The character and velocity of the main flow at the diaphragm-housing junction were acquired using a laser light sheet method with polyethylene tracers. Wall shear flow, a major factor governing washout in the blood pump, was estimated by a newly developed paint erosion method. In this method, quantitative evaluation for an index of washout effect was made by calculating the residual ratio of the paint on the blood pump inner surface at 30 sec of pumping. When a single circular flow was consistently observed by the laser light sheet method, the paint residual ratio become low, indicating washout was relatively good. At the lowest paint residual ratio, the center of the circular flow observed by the laser light sheet method was located at the geometric center of the blood chamber. In conclusion, the flow pattern inside the blood pump could be characterized by combined use of these two flow visualization techniques, and the significant role of circular flow in better washout was clarified.  相似文献   

20.
Removal of unwanted particles from molten metal by flotation is one of the most useful melt cleansing techniques used by the foundry industry. An effective way of flotation of particles in a melt relies on purging a gas into the molten metal through holes in a rotating impeller. Impeller rotation creates turbulence inside the melt, which helps agglomerate the impurity particles and, thereby, enhances their removal from the melt. In addition, turbulence increases the probability of particles attaching to the rising gas bubbles and, therefore, enhances the chance of their removal from the molten metal. A mathematical model has been developed to simulate the turbulent multiphase flow field inside the flotation treatment furnace. Simulations based on the model were used to demonstrate the effect of the various process parameters on the performance of a batch-type rotating impeller particle flotation process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏