1.
PURPOSE: To report the feasibility and sensitivity of duplex sonography compared to computed tomography (CT) for aortic endograft follow-up surveillance. METHODS: In a 26-month period, 113 aortic aneurysm patients received 79 tube and 34 bifurcated stent-grafts. Follow-up used contrast-enhanced CT scanning and duplex sonography with an intravenous ultrasound contrast agent (Levovist). RESULTS: Eleven patients (9.7%) were converted to open repair; 1 died from hemorrhagic shock secondary to retroperitoneal hematoma. The mean follow-up time was 7.2 months (range 1 to 24), during which 5 patients died of unrelated causes. Sixteen primary (within 30 days) and 5 secondary endoleaks were detected by duplex after tube graft implantation. Among 5 endoleaks due to retrograde side-branch perfusion, 3 were detected only with contrast-enhanced duplex scanning. Iliac artery occlusion was also documented using duplex; however, 2 stent fractures could not be seen with ultrasound. Ten primary endoleaks were detected in bifurcated stent-graft patients. One endoleak originating from the distal iliac limb anchoring site was missed by duplex owing to bowel gas. Graft limb thrombosis was clearly identified by lack of a flow signal on duplex. CONCLUSIONS: Duplex sonography could be a valuable, reliable, and economical surveillance tool for endovascular aortic reconstructions. The adjunctive use of an intravenous ultrasound contrast agent increased the sensitivity for detecting endoleak to a level comparable to contrast-enhanced CT scanning. However, stent fractures may not be seen on ultrasound, and bowel gas can interfere with obtaining an adequate image.  相似文献   

2.
PURPOSE: Incomplete endovascular graft exclusion of an abdominal aortic aneurysm results in an endoleak. To better understand the pathogenesis, significance, and fate of endoleaks, we analyzed our experience with endovascular aneurysm repair. METHODS: Between November 1992 and May 1997, 47 aneurysms were treated. In a phase I study, patients received either an endovascular aortoaortic graft (11) or an aortoiliac, femorofemoral graft (8). In phase II, procedures and grafts were modified to include aortofemoral, femorofemoral grafts (28) that were inserted with juxtarenal proximal stents, sutured endovascular distal anastomoses within the femoral artery, and hypogastric artery coil embolization. Endoleaks were detected by arteriogram, computed tomographic scan, or duplex ultrasound. Classification systems to describe anatomic, chronologic, and physiologic endoleak features were developed, and aortic characteristics were correlated with endoleak incidence. RESULTS: Endoleaks were discovered in 11 phase I patients (58%) and only six phase II patients (21%; p < 0.05). Aneurysm neck lengths 2 cm or less increased the incidence of endoleaks (p < 0.05). Although not significant, aneurysms with patent side branches or severe neck calcification had a higher rate of endoleaks than those without these features (47% vs 29% and 57% vs 33%, respectively), and patients with iliac artery occlusive disease had a lower rate of endoleaks than those without occlusive disease (18% vs 42%). Endoleak classifications revealed that most endoleaks were immediate, without outflow, and persistent (71% each), proximal (59%), and had aortic inflow (88%). One patient with a persistent endoleak had aneurysm rupture and died. CONCLUSIONS: Endoleaks complicate a significant number of endovascular abdominal aortic aneurysm repairs and may permit aneurysm growth and rupture. The type of graft used, the technique of graft insertion, and aortic anatomic features all affect the rate of endoleaks. Anatomic, chronologic, and physiologic classifications can facilitate endoleak reporting and improve understanding of their pathogenesis, significance, and fate.  相似文献   

3.
At Nuremberg Southern Hospital we have been using endovascular therapy for aortic aneurysms for the past 3 years. Between August 1994 and August 1997, 193 patients with infrarenal aortic aneurysms were treated with endovascular stent grafts. Besides using commercially available modular systems of the Stentor type (MinTec/Vanguard*, Boston Scientific) we also participated in a multicenter study implanting EGS devices (EVT in 65 patients). Follow-up examinations must strive to detect thrombotic complications as well as endoleaks with high sensitivity and specificity. To avoid aneurysm rupture significant increase in aneurysm diameter must be detected in a timely fashion to select patients for additional corrective endovascular procedures or conversion to open surgical therapy. A close follow-up regimen therefore is absolutely mandatory for all patients undergoing endovascular aortic grafting, particularly when new prosthetic devices are being introduced. Prosthetic devices that have been adequately tested using controlled study designs and are commercially available may be followed-up using a standardized follow up scheme as delineated. Particularly during the first postoperative year color duplex with use of an intravenous ultrasound enhancing agent has been used successfully to detect even minor endoleaks originating from retrograde perfusion via aortic side branches (lumbar or inferior mesenteric artery). Only patients with documented endoleaks or suspected outflow obstruction requiring further intervention need to undergo diagnostic arteriography. After conventional aneurysm repair yearly duplex scans are usually sufficient to follow the normal patient. Patients who have undergone endovascular therapy, however need to be followed much closer using duplex as well as abdominal CT scans. This will logically result in significantly higher follow up costs. Periinterventional costs of endovascular aortic reconstruction currently exceed those of conventional aortic repair by approximately 50%. Given the current health care finance situation it is questionable whether endovascular therapy of abdominal aneurysm will become standard practice in Germany.  相似文献   

4.
PURPOSE: Successful endovascular repair of an abdominal aortic aneurysm (AAA) requires the creation of a hemostatic seal between the endograft and the underlying aortic wall. A short infrarenal aortic neck may be responsible for incomplete aneurysm exclusion and procedural failure. Sixteen patients who had an endograft positioned completely below the lowest renal artery and 37 patients in whom a porous portion of an endograft attachment system was deliberately placed across the renal arteries were studied to identify if endograft positioning could impact on the occurrence of incomplete aneurysm exclusion. METHODS: Fifty-three patients underwent aortic grafting constructed from a Palmaz balloon expandable stent and an expandable polytetrafluoroethylene (ePTFE) graft implanted in an aorto-ilio-femoral, femoral-femoral configuration. Arteriography, duplex ultrasonography and spiral CT scans were performed in each patient before and after endografting to evaluate for technical success, the presence of endoleaks, and renal artery perfusion. RESULTS: There was no statistically significant difference in patient demography, AAA size, or aortic neck length or diameter between patients who had their endografts placed below or across the renal arteries. However, significantly more proximal aortic endoleaks occurred in those patients with infrarenal endografts (P < or = .05). Median serum creatinine level before and after endografting was not significantly different between the 2 patient subgroups, with the exception of 2 patients who had inadvertent coverage of a single renal orifice by the endograft. Median blood pressure and the requirement for antihypertensive therapy remained the same after transrenal aortic stent grafting. Significant renal artery compromise did not occur after appropriately positioned transrenal stents as shown by means of angiography, CT scanning, and duplex ultrasound scan. Mean follow-up time was 10.3 months (range, 3 to 18 months). Patients who had significant renal artery stenosis (> or =50%) before aortic endografting did not show progression of renal artery stenosis after trans-renal endografting. Two patients with transrenal aortic stent grafts had inadvertent coverage of 1 renal artery by the endograft because of device malpositioning, which resulted in nondialysis dependent renal insufficiency. In addition, evidence of segmental renal artery infarction (<20% of the kidney), which did not result in an apparent change in renal function, was shown by means of follow-up CT scans in 2 patients with transrenal endografts. CONCLUSION: Transrenal aortic endograft fixation using a balloon expandable device in patients with AAAs can result in a significant reduction in the risk of proximal endoleaks. Absolute attention to precise device positioning, coupled with the use of detailed imaging techniques, should reduce the risk of inadvertent renal artery occlusion from malpositioning. Long-term follow-up is essential to determine if there will be late sequelae of transrenal fixation of endografts, which could adversely effect renal perfusion.  相似文献   

5.
PURPOSE: To determine the safety, effectiveness, and problems encountered with endovascular repair of abdominal aortic aneurysm (AAA). Initial experience with endoluminal stent grafts was examined and compared with outcome for a matched concurrent control group undergoing conventional operative repair of AAA. METHODS: Over a 3-year period, 30 patients underwent attempts at endovascular repair of infrarenal AAA. Of the 28 (93%) successfully implanted endografts, 8 were tube endografts, 8 bifurcated grafts, and 12 aortouniiliac grafts combined with femorofemoral bypass. Most of the procedures were performed in the past year because the availability of bifurcated and aortoiliac endografts markedly expanded the percentage of patients with AAA who might be treated with endoluminal methods. The follow-up period ranged from 1 to 44 months, with a mean value of 11 months. RESULTS: Endovascular procedures demonstrated significant advantages with respect to reduced blood loss (408 versus 1287 ml), use of an intensive care unit (0.1 versus 1.75 days), length of hospitalization (3.9 versus 10.3 days), and quicker recovery (11 versus 47 days). Although the total number of postoperative complications was identical for the two groups, the nature of the complications differed considerably. Local and vascular complications characteristic of endovascular repair could frequently be corrected at the time of the procedure and tended to be less severe than systemic or remote complications, which predominated among the open surgical repair group. On an intent-to-treat basis, 23 (77%) of the 30 AAAs were successfully managed with endoluminal repair. The seven (23%) failures were attributable to two immediate conversions caused by access problems, three persistent endoleaks, one late conversion caused by AAA expansion, and one late rupture. CONCLUSIONS: Although less definitive than those for conventional operations, these early results suggest that endovascular AAA repair offers considerable benefits for appropriate patients. The results justify continued application of this method of AAA repair, particularly in the treatment of older persons at high risk.  相似文献   

6.
To evaluate spiral-computed tomography (CT) angiography in primary diagnosis and/or in noninvasive follow-up after vascular intervention, we compared spiral-CT angiography and conventional angiography before and after vascular intervention. Helical-CT examinations before and after percutaneous transluminal angioplasty (PTA) or stent implantation were performed in 10 patients (mean age 63 years) with symptomatic peripheral arteriosclerotic disease. Stenoses were located in the iliac, femoral, or popliteal artery. CT examinations were done with a spiral-CT in double detector technique (CT Twin, Elscint). The parameters were as follows: slice thickness: 5.5 mm, increment: 2.7 mm, pitch: 1.5, contrast medium: 150 mL, flow rate: 2.5 mL/second, delay: 30 seconds. For evaluation, transverse planes as well as maximum intensity projections and 3-D reconstructions were used. The possible scan length reached from the aortic bifurcation down to about 10 cm below the ankle trifurcation. Preinterventional digital subtraction angiography (DSA) was superior to CT angiography (CTA: 94%, maximum intensity projection [MIP] alone: 65%), although high-grade stenoses were detected by both methods. After intervention, a resolved stenosis and improved peripheral flow could be detected by helical-CT as well as by intraarterial angiography in every patient (100%). In the primary diagnosis of vascular changes, intraarterial DSA remains the method of choice. Nevertheless, spiral-CT angiography shows comparable results after percutaneous intervention and becomes a noninvasive alternative in the postinterventional follow-up.  相似文献   

7.
PURPOSE: To investigate the reasons for endoleaks after transluminal infrarenal abdominal aneurysm management and the potential for transluminal interventions in subsequent management. METHODS: Prospective analysis of 50 consecutive patients undergoing endovascular aneurysm repair at a single institution with Stentor and Vanguard grafts from March 1995 to March 1997. SETTING: Academic teaching hospital. RESULTS: Two procedures were converted for other reasons than leak. In the remaining 48 successful procedures endoleaks were detected in 11 (22.9%): proximal aortic leak (2.1%), distal aortic leak (8.3%), iliac leak (12.5%). Leaks were treated at the initial procedure in five patients, resulting in 87.5% excluded aneurysms. Twelve and a half per cent were discharged with a primary leak. Redo was performed on all iliac leaks within 7 weeks. All aortic leaks showed spontaneous thrombosis within 3 months, but reappeared with local aneurysm expansion. Aortic redo-procedures were performed by proximal tubular extension or converting a tube graft into a bifurcation graft. All rescue procedures were successful. Secondary leaks have been observed twice in this series, both treated by endovascular means. CONCLUSIONS: Endovascular treatment of primary and secondary endoleaks is possible, and may be a safe alternative to a difficult open procedure.  相似文献   

8.
Between August 1994 and December 1996 137 patients (10 female and 127 male, mean age 66 yrs., range 27-85) with aortoiliac aneurysmal disease were treated with endovascular stent grafts. Pathology included 5 thoracic, 131 abdominal and 1 isolated iliac artery aneurysm. 88 straight tube grafts (75 Mintec, 12 EVT, 1 Chuter) and 43 bifurcated grafts (21 Mintec, 20 EVT, 2 Chuter) were implanted in the infrarenal aorta. 5 (Mintec) tube grafts were used for the thoracic aneurysms. One tapered tube graft was used to exclude the isolated iliac aneurysm. 11 patients (8%) required conversion to open surgical repair. This was due to defective devices in 5, device related occlusion of a renal artery in 2, aortic dissection in 1, occlusion of iliac outflow in 1, a large unmanageable proximal endoleak in 1 and a retroperitoneal bleeding resulting in hemorrhagic shock in 1 patient. There was one procedure related death for a mortality of 0.7%. Patients were followed every 3-6 months using CT with i.v. contrast and ultrasound duplex examinations with adjunctive usage of an intravenous ultrasound contrast agent (Levovist, Schering AG). Intraarterial DSA was used only when called for by thrombotic or stenotic complications. At a mean follow-up of 9.2 months (range 2-24 months) 16 (17%) primary and 8 (8.5%) secondary leaks (at the distal anchoring zone) were detected after implantation of tube grafts. 11 (25.6%) leaks were detected after implantation of bifurcated grafts. Iliac artery occlusion was observed in 2 patients after placement of a straight endograft, 6 times after reconstruction with a Mintec bifurcated device and 3 times after implantation of an EVT bifurcated endograft. Successful treatment of iliac artery occlusion without the need for subsequent amputation or major disability included extraanatomic bypass in 7 patients, PTA (3 patients) and implantation of wallstents (2 patients) or conservative management (1 patient).  相似文献   

9.
Endovascular graft repair for aortic aneurysms has led to concerns regarding the healing characteristics of the graft within a thrombus-lined aneurysm and the effect that collateral flow may have on the endoluminal prosthesis and the aneurysm. An anterior aortic patch aneurysm model that preserved collateral arteries was examined and modified to address these issues. In canines (n = 30) a Dacron knitted patch (n = 27) or a rectus fascia patch (n = 3) was sutured into a 3.5-cm anterior aorotomy. Dacron patch aneurysm diameter was an average of 21.8 +/- 2.2 mm (mean canine normal aortic diameter 9.06 +/- 0.79 mm). Canines underwent angiogram, computed tomography, and/or intravascular ultrasound from 1 to 11 weeks later, at which time an endoluminal prosthesis was deployed and followed 30 to 60 days until harvest. Aneurysms accumulated minimal thrombus through the initial 11 weeks. Significant stenosis (mean 21.2% +/- 19%) occurred at aneurysm necks in association with a patch imbrication suture technique (n = 11). Following modification (n = 16), this decreased to a mean of 3.6 +/- 9.7%. Collateral lumbar artery patency was 95% at the time of imaging prior to graft placement. Following successful graft implantation, 16 of 18 aneurysms were filled with thrombus and in most cases the collateral circulation occluded. One of three fascial patch aneurysms ruptured 21 days after creation. This model more accurately depicts abdominal aortic aneurysms with the inherent thrombus and collateral flow that is important when studying aspects of endovascular aortic graft repair.  相似文献   

10.
PURPOSE: The aim of this study was to report the repair of an aneurysm of the internal carotid artery using the endoluminal method. METHODS: A 70-year-old male patient noted a swelling in the right side of his neck 22 years after endarterectomy of the right internal carotid artery. Duplex ultrasound confirmed the clinical diagnosis of aneurysm of the internal carotid artery. Further investigation included contrast-enhanced computed tomographic (CT) scanning and carotid angiography performed via a retrograde femoral approach. The aneurysm contained thrombus and was 3 cm in diameter and in length. It extended superiorly from a point 0.5 cm above the carotid bifurcation to a point estimated to be 2 cm from the base of the skull. Repair of the aneurysm was undertaken using the endoluminal method. A self-expanding endograft 8 mm in diameter and 4 cm in length was introduced through a 12F sheath in the common carotid artery. An on-table completion angiogram of the right-sided extracranial carotid arteries and the intracranial internal carotid artery and branches was obtained. RESULTS: The completion angiogram and postoperative CT scan confirmed exclusion of the aneurysm sac from the circulation. The patient awoke from anesthesia with complete paralysis of the left arm. Recovery of movement commenced 1 hour later. A brain CT scan demonstrated the event to be an embolic stroke. Strength had returned by 7 days. Function of the arm was good 1 month after operation, but coordination for fine movements was lacking. At the 6-month follow-up, good arm function was maintained. A duplex ultrasound scan demonstrated not only continued exclusion of the aneurysm sac but occlusion of the endograft, also. CONCLUSIONS: Endoluminal repair of aneurysms of the internal carotid artery is feasible but carries the risk of major morbidity as a result of peripheral embolization and early occlusion of the endograft.  相似文献   

11.
BACKGROUND: A detailed knowledge of the morphology of the aorta and iliac arteries is an important prerequisite for successful endoluminal abdominal aortic aneurysm (AAA) repair. The best method of preoperative evaluation remains to be determined. METHODS: A prospective study was undertaken between January 1994 and July 1995 to assess the ability of computed tomography (CT), magnetic resonance angiography (MRA), colour duplex imaging and intra-arterial digital subtraction angiography (IA-DSA) to visualize AAA morphology. RESULTS: Eighty-two consecutive patients (64 men, 18 women) with AAA were assessed with MRA, contrast-enhanced CT, colour duplex imaging and IA-DSA. Median age was 74 (range 59-87) years and median AAA diameter was 5.7 (range 3.5-9.7) cm. Five patients were unable to tolerate CT or MRA examination. Seventy-seven patients underwent both CT and MRA. Of these, 55 also had a colour duplex scan and 32 underwent arteriography. The scans were assessed by an independent blinded observer. MRA was significantly better (P < 0.01) at visualizing AAA morphology compared with CT and colour duplex imaging. There was no statistically significant difference between MRA and arteriography. CONCLUSION: MRA is useful in patient selection for endoluminal AAA repair, as it avoids use of iodinated contrast medium and ionizing radiation.  相似文献   

12.
PURPOSE: Nonresective treatment of the infrarenal abdominal aortic aneurysm by proximal and distal ligation of the aneurysm sac (exclusion) combined with aortic bypass has been previously reported. A 10-year experience with 831 patients undergoing this procedure was reviewed. METHODS: From 1984 to 1994, 831 (761 elective, 70 urgent) of 1103 patients being treated for abdominal aortic aneurysm underwent repair with the retroperitoneal exclusion technique. Perioperative morbidity and mortality, estimated blood loss, transfusion requirements, natural history of the excluded aneurysm sac, and long-term survival were all assessed. RESULTS: The operative mortality rate for patients undergoing exclusion and bypass was 3.4%. The incidence of nonfatal perioperative complications was 5.2%. Colon ischemia requiring resection occurred in 2 (0.2%) of the 831 patients. Estimated blood loss was 638 +/- 557 cc (50 to 330 cc). On follow-up 17 (2%) patients were found to have patent aneurysm sacs as detected by duplex examination. Fourteen patients required surgical intervention. No cases of graft infection or aortoenteric fistula have been noted. CONCLUSION: Retroperitoneal exclusion and bypass is a viable alternative to traditional open endoaneurysmorraphy in surgery for abdominal aortic aneurysm. Most excluded aneurysm sacs have thrombosis without any long- or short-term complications; however, in a small number of patients delayed rupture of patent aneurysm occurs, thus emphasizing the need for diligent follow-up and appropriate intervention.  相似文献   

13.
PURPOSE: This report reviews our preliminary experience of prospective treatment of arterial lesions with endoluminal grafts in a Food and Drug Administration (FDA)-approved, investigator-sponsored Investigation Device Exemptions study. The utility and accuracy of various imaging methods, including angiography, cinefluoroscopy, computed tomography (CT), intravascular ultrasonography (IVUS), and duplex scanning, in performing the procedures was also assessed. METHODS: Thirty-one patients were evaluated; 17 patients were treated, including 11 with abdominal aortic aneurysms, one with an aortic occlusive lesion, two with iliac artery aneurysms, and three with traumatic arteriovenous fistulas. Twelve of the 14 patients who had aorta and iliac artery lesions were high-risk. The mean follow-up of patients treated was 9 months (range, 6 to 15 months). RESULTS: Aortoaortic endoluminal interposition procedures were not successful for treating abdominal aortic aneurysms early in the study (n = 3). Aortoiliac endoluminal bypass, contralateral iliac artery occlusion, and femorofemoral bypass procedures were successful in seven of eight subsequent cases (88%), with no incidence of endoleaks at either the proximal or distal fixation sites using the deployment methods described in this report. The 30-day operative mortality rate on follow-up evaluations for patients who underwent aortoiliac procedures was 14% (two of 14). Other major complications included transient renal failure in three patients that required short-term (two to eight times) dialysis, one arterial perforation and one dissection, and one prolonged intubation. No myocardial infarctions or strokes occurred. After major complications or identification of limitations in the study, the protocol was modified with the approval of the FDA to help avoid the recurrence of the same problems. There were no deaths or complications in the trauma cases. CONCLUSIONS: Contrast-enhanced CT (axial images and spiral reconstructions) was the most accurate method to determine candidacy for aortoiliac procedures and to choose the site for deployment of the devices. Angiographic scans were misleading in several patients regarding the critical determinants of patient candidacy and device deployment, particularly regarding the presence of a distal aortic neck. Cinefluoroscopy was used in all patient and was particularly useful for determining the continuity of vascular structures and the anatomy of branch arteries and for enabling precise positioning of stent devices. Determination of fixation sites and assessing dimensional information by cinefluoroscopy and angiography were limited by inaccuracies produced by image magnification, parallax, and uniplanar views. IVUS was used to determine the morphologic features of vascular structures (i.e., calcium, thrombus), to perform real-time observation of the expansion of devices, and to assure firm fixation of balloon-expanded stents before the procedures were completed. Duplex scanning was very helpful in assessing and identifying precisely the location of arteriovenous fistulas before intervention and provided assessment at follow-up intervals. Three-dimensional reconstruction imaging technologies such as spiral CT were particularly helpful for assessing the morphologic features of vascular anatomy before the intervention and at follow-up intervals, whereas 3-D IVUS provided a similar real-time perspective during the procedure.  相似文献   

14.
The results of a prospective, nonrandomized, multicenter clinical trial that compared endovascular stent graft exclusion of abdominal aortic aneurysms with open surgical repair are presented. During an 18-month period, 250 patients with infrarenal aneurysms underwent treatment at 12 study sites-190 patients underwent endovascular repair using the Medtronic AneuRx stent graft (Sunnyvale, Calif), and 60 underwent open surgical repair. There was no significant difference in operative mortality rates between the groups. The patients who underwent stent grafting had significant reductions in blood loss, time to extubation, and days in the intensive care unit and in the hospital, with an earlier return to function. The major morbidity rate was reduced from 23% in the surgery group to 12% (P <. 05) in the stent graft group. There was no difference in the combined morbidity/mortality rates between the two groups. Primary technical success at the time of discharge for the patients with stent grafts was 77%, largely as a result of a 21% endoleak rate. At 1 month, the endoleak rate had decreased to 9%. There was no difference in the primary or secondary procedure success rates at 30 days between the surgery and stent graft groups. The primary graft patency rate at 6 months was 98% in the surgery group and 97% in the stent graft group. The aneurysm exclusion rate at 1 month and 6 months was 100% in patients who underwent surgery and 91% in patients who underwent stent grafting. Stent graft migration occurred in three patients and resulted in late endoleaks; each endoleak was corrected by means of endovascular placement of a stent graft extender cuff. There have been no aneurysm ruptures and no surgical conversions to open repair in the stent graft group. Stent graft repair compares favorably with open surgical repair, with a reduced morbidity rate, shortened hospital stays, and satisfactory short term outcomes.  相似文献   

15.
PURPOSE: To investigate the relation between endoleaks and intraaneurysmal pressure (IAP) and the effect of coil embolization in the management of endoleaks. METHODS: The infrarenal aorta of a dog (n = 15) was replaced by a polytetrafluoroethylene aneurysm containing a pressure transducer. Group I (n = 4) had untreated aneurysms. Group II (n = 4) had endovascularly excluded aneurysms without an endoleak. Group III (n = 7) had aneurysms excluded by means of grafts with a defect that represented the source of an endoleak. After 4 weeks of follow-up study, the endoleaks in group III dogs were subjected to coil embolization. Systolic IAP was measured daily and expressed as a ratio of systolic blood pressure obtained from a forelimb cuff. Arteriography, duplex ultrasonography, and spiral contrast computed tomography were performed to evaluate endoleaks. RESULTS: In group I, the LAP remained close to systolic blood pressure (ratio of 0.96 +/- 0.06), whereas in group II the IAP ratio showed a decline to 0.34 +/- 0.16 (p = 0.0009 group I versus II). After an initial decrease, the IAP ratio in group III stabilized at 0.75 +/- 0.18 (p = 0.003, group II versus III). Aneurysms with an endoleak remained pulsatile with a pulse pressure of 30 +/- 16 mm Hg, which was less than that of untreated aneurysms (62 +/- 15 mm Hg; p < 0.0001 group I versus III). Arteriography and computed tomography revealed "sealing" of endoleaks after coil embolization, but IAP ratio did not decrease (0.76 +/- 0.14) after coil embolization. CONCLUSIONS: Incomplete endovascular aneurysm exclusion caused by an endoleak fails to reduce IAP ratio and may subject the aneurysm to a continued risk for rupture. Although coil embolization resulted in angiographic and computed tomographic sealing, it failed to reduce IAP ratio.  相似文献   

16.
Trauma, dissociation, and somatization: a self-psychological perspective   总被引:1,自引:0,他引:1  
Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.  相似文献   

17.
BACKGROUND: The traditional treatment of aneurysms of the descending thoracic aorta includes posterolateral thoracotomy and aortic replacement with a prosthetic graft. In this study, we report our experiences and results in endovascular stent graft placement as an alternative to surgical repair. METHODS: Between January 1989 and July 1997, a total of 68 patients (24 women) underwent replacement of the thoracic aorta. Mean age at operation was 51 years. Fifty-eight patients underwent conventional surgical treatment. All of these patients were suitable candidates for endovascular stenting; however, no stent graft material was available at the time of operation. Ten patients (1 chronic dissection, 9 atherosclerotic aneurysm) received in the past 8 months the first commercially manufactured endovascular stent graft. The mean diameter of the aneurysms in this group was 7 cm (range, 6 to 8 cm). Two stent patients were operated on using only spinal cord analgesia. All stent grafts were custom designed for each of the 10 patients. RESULTS: The 30-day mortality in the conventional group was 31% versus 10% in the stent group. Mean length of intervention was 320 minutes in the conventional group versus 150 minutes in the endovascular group. Spinal cord injury occurred in 5 patients (12%) in the surgical group, whereas none of the stented patients developed any neurologic sequelae. Mean intensive care unit stay was 13 days, followed by a mean of 10 days on a ward in the first group compared to 4 days in the intensive care unit and 6 days on the ward in the stent group. One stent was required in 2 patients, two stents were required in 3 patients, and four stents were deployed in 5 patients of our series. Five patients required transposition of the left subclavian artery to achieve a sufficient neck for the proximal placement of the stent. There was complete thrombosis of the thoracic aortic aneurysm surrounding the stent graft in 8 patients (80%). Two patients required restenting as a result of leakage (20%). Stent graft placing was performed through the femoral artery in 8 patients, whereas access was only achieved through the abdominal aorta in 2 patients. CONCLUSIONS: These preliminary results demonstrate that endovascular stent graft replacement might be a promising, cheaper, and safe alternative method in selected patients with descending thoracic aneurysms.  相似文献   

18.
Vascular surgeons are increasingly encountering older patients with large aneurysms associated with severe comorbid conditions. This situation can increase operative morbidity and elevate the mortality rate of aortic surgery over 60%. With some frequency many patients will represent a prohibitive risk for conventional graft replacement. The endoluminal treatment of 110 patients has proved to be feasible and may represent an alternative solution. One hundred six of the patients had an abdominal aortic aneurysm and in four patients, the thoracic aorta was involved. All of them underwent endoluminal repair for the aortic pathology using the combination of stents and grafts in aorto-aortic or aorto-iliac position, with straight, tapered, or bifurcated stent-graft devices. The results are as follows: Initial success was 84% in aorto-aortic abdominal devices and 100% in aorto-aortic thoracic devices. In aorto-iliac devices, initial success was 75%. Late success rates were 62% of the initial group and 80% of the initially successful group.  相似文献   

19.
OBJECTIVE: Because isolated common iliac artery aneurysms are infrequent, are difficult to detect and treat, and have traditionally been associated with high operative mortality rates in reported series, we analyzed the outcomes of operative repair of 31 isolated common iliac artery aneurysms in 21 patients to ascertain morbidity and mortality rates with contemporary techniques of repair. METHODS: A retrospective review study was conducted in a university teaching hospital and a Department of Veterans Affairs Medical Center. Perioperative mortality and operative morbidity rates were examined in 17 men and four women with isolated common iliac artery aneurysms between 1984 and 1997. Ages ranged from 38 to 87 years (mean 69 +/- 8 years). Slightly more than half of the cases were symptomatic, with abdominal pain, neurologic, claudicative, genitourinary, or hemodynamic symptoms. One aneurysm had ruptured and one was infected. There was one iliac artery-iliac vein fistula. All aneurysms involved the common iliac artery. Coexistent unilateral or bilateral external iliac aneurysms were present in four patients; there were three accompanying internal iliac aneurysms. Overall, 52% of patients had unilateral aneurysms and 48% had bilateral aneurysms. Aneurysms ranged in maximal diameter from 2.5 to 12 cm (mean 5.6 +/- 2 cm). No patients were unavailable for follow-up, which averaged 5.5 years. RESULTS: Nineteen patients underwent direct operative repair of isolated iliac aneurysms. One patient had placement of an endoluminal covered stent graft; another patient at high risk had percutaneous placement of coils within the aneurysm to occlude it in conjunction with a femorofemoral bypass graft. Patients with bilateral aneurysms underwent aortoiliac or aortofemoral interposition grafts, whereas unilateral aneurysms were managed with local interposition grafts. There were no deaths in the perioperative period. Only one elective operation (5%) resulted in a significant complication, compartment syndrome requiring fasciotomy. The patient treated with the covered stent required femorofemoral bypass when the stent occluded 1 week after the operation. The patient treated with coil occlusion of a large common iliac aneurysm died 2 years later when the aneurysm ruptured. CONCLUSIONS: Isolated iliac artery aneurysms can be managed with much lower mortality and morbidity rates than aneurysm previously been reported by using a systematic operative approach. Percutaneous techniques may be less durable and effective than direct surgical repair.  相似文献   

20.
DA Lipski  CB Ernst 《Canadian Metallurgical Quarterly》1998,27(5):805-11; discussion 811-2
PURPOSE: We determined the natural history of the residual native infrarenal aortic segment after conventional abdominal aortic aneurysm (AAA) repair. METHODS: For the retrospective arteriographic case series, 800 hundred translumbar aortograms (TLAs) were obtained for 272 patients, before and after conventional AAA repair. The main outcome measures were changes in the aortographic diameter and the length of the infrarenal aortic segment, corrected and uncorrected for magnification by normalization to the first lumbar vertebral body height. RESULTS: The mean follow-up time from the preoperative TLA to the most recent postoperative TLA was 42 months (range, 1 to 257 months). Vertebral body height did not change (p = 0.35). The length of the native infrarenal aorta cephalad to the proximal anastomosis increased a mean of 3 mm, from 23 to 26 mm (p = 0.001). However, in 115 patients (43%), this aortic segment elongated more than 5 mm, and in 63 patients (24%), it elongated more than 10 mm. The native residual infrarenal aorta above the proximal anastomosis dilated a mean of 1 mm, from 23 to 24 mm (p = 0.001), but in 21 patients (8%), it dilated more than 5 mm. There was a weak positive correlation between the increase in residual native aortic diameter and duration of follow-up. There was a negative correlation between this increase and the initial size. The diameters of the proximal anastomosis and proximal graft did not change. Marked variability in the changes in aortic dimensions was observed. CONCLUSIONS: A mean period of 42 months after conventional AAA repair, the native infrarenal aortic segment elongates and dilates. Although such enlargement is statistically significant, the average increase appears to be small. However, residual aortic cuff diameter increased more than 5 mm and neck length more than 10 mm in a significant number of patients, with potentially serious implications for endovascular treatment of AAA.  相似文献   