首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Single-phase heat transfer and pressure drop characteristics of a commercially available internally micro-finned tube with a nominal outside diameter of 7.94 mm were studied. Experiments were conducted in a double pipe heat exchanger with water as the cooling as well as the heating fluid for six sets of runs. The pressure drop data were collected under isothermal conditions. Data were taken for turbulent flow with 3300 ≤ Re ≤ 22,500 and 2.9 ≤ Pr ≤ 4.7. The heat transfer data were correlated by a Dittus–Boelter type correlation, while the pressure drop data were correlated by a Blasius type correlation. The correlation predicted values for both the Nusselt number and the friction factors were compared with other studies. It was found that the Nusselt numbers obtained from the present correlation fall in the middle region between the Copetti et al. and the Gnielinski smooth tube correlation predicted Nusselt number values. For pressure drop results, the present correlation predicted friction factors values were nearly double that of the Blasius smooth tube correlation predicted friction factors. It was also found that the rough tube Gnielinski and Haaland correlations can be used as a good approximation to predict the finned tube Nusselt number and ffriction factor, respectively, in the tested Reynolds number range.  相似文献   

2.
Heat transfer of ice slurry flow based on ethanol–water mixture in a circular horizontal tube has been experimentally investigated. The secondary fluid was prepared by mixing ethanol and water to obtain initial alcohol concentration of 10.3% (initial freezing temperature -4.4 °C). The heat transfer tests were conducted to cover laminar and slightly turbulent flow with ice mass fraction varying from 0% to 22% depending on test performed. Measured heat transfer coefficients of ice slurry are found to be higher than those for single phase fluid, especially for laminar flow conditions and high ice mass fractions where the heat transfer is increased with a factor 2 in comparison to the single phase flow. In addition, experimentally determined heat transfer coefficients of ice slurry flow were compared to the analytical results, based on the correlation by Sieder and Tate for laminar single phase regime, by Dittus–Boelter for turbulent single phase regime and empirical correlation by Christensen and Kauffeld derived for laminar/turbulent ice slurry flow in circular horizontal tubes. It was found that the classical correlation proposed by Sieder and Tate for laminar forced convection in smooth straight circular ducts cannot be used for heat transfer prediction of ice slurry flow since it strongly underestimates measured values, while, for the turbulent flow regime the simple Dittus–Boelter relation predicts the heat transfer coefficient of ice slurry flow with high accuracy but only up to an ice mass fraction of 10% and Recf > 2300 regardless of imposed heat flux. For higher ice mass fractions and regardless of the flow regime, the correlation proposed by Christensen and Kauffeld gives good agreement with experimental results.  相似文献   

3.
The heat transfer coefficient and pressure drop during gas cooling process of CO2 (R744) in a horizontal tube were investigated experimentally. The experiments are conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a gas cooler (test section). The water loop consists of a variable speed pump, an isothermal tank, and a flow meter. The refrigerant, circulated by the variable-speed pump, condenses in the inner tube while water flows in the annulus. The gas cooler of tube diameter is 6000 mm in length, and it is divided into 12 subsections.The pressure drop of CO2 in the gas cooler shows a relatively good agreement with those predicted by Blasius's correlation. The local heat transfer coefficient of CO2 agrees well with the correlation by Bringer–Smith. However, at the region near Pseudo-critical temperature, the experiments indicate higher values than the Bringer–Smith correlation. Based on the experimental data presented in this paper, a new correlation to predict the heat transfer coefficient of supercritical CO2 during in-tube cooling has been developed. The majority of the experimental values are within 18% of the values predicted by the new correlation.  相似文献   

4.
The objective of this study is to provide experimental data that can be used in the optimal design of flat plate finned-tube heat exchangers with large fin pitch. In this study, 22 heat exchangers were tested with a variation of fin pitch, number of tube row, and tube alignment. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row. The reduction in the heat transfer coefficient of the four-row heat exchanger coil was approximately 10% as the fin pitch decreased from 15.0 to 7.5 mm over the Reynolds number range of 500–900 that was calculated based on the tube diameter. For all fin pitches, the heat transfer coefficient decreased as the number of tube row increased from 1 to 4. The staggered tube alignment improved heat transfer performance more than 10% compared to the inline tube alignment. A heat transfer correlation was developed from the measured data for flat plate finned-tubes with large fin pitch. The correlation yielded good predictions of the measured data with mean deviations of 3.8 and 6.2% for the inline and staggered tube alignment, respectively.  相似文献   

5.
This paper presents the experimental tests on HFC-134a condensation inside a small brazed plate heat exchanger: the effects of refrigerant mass flux, saturation temperature and vapour super-heating are investigated.A transition point between gravity controlled and forced convection condensation has been found for a refrigerant mass flux around 20 kg/m2 s. For refrigerant mass flux lower than 20 kg/m2 s, the saturated vapour heat transfer coefficients are not dependent on mass flux and are well predicted by the Nusselt [Nusselt, W., 1916. Die oberflachenkondensation des wasserdampfes. Z. Ver. Dt. Ing. 60, 541–546, 569–575] analysis for vertical surface. For refrigerant mass flux higher than 20 kg/m2 s, the saturated vapour heat transfer coefficients depend on mass flux and are well predicted by the Akers et al. [Akers, W.W., Deans, H.A., Crosser, O.K., 1959. Condensing heat transfer within horizontal tubes. Chem. Eng. Prog. Symp. Ser. 55, 171–176] equation. In the forced convection condensation region, the heat transfer coefficients show a 30% increase for a doubling of the refrigerant mass flux. The condensation heat transfer coefficients of super-heated vapour are 8–10% higher than those of saturated vapour and are well predicted by the Webb [Webb, R.L., 1998. Convective condensation of superheated vapour. ASME J. Heat Transfer 120, 418–421] model. The heat transfer coefficients show weak sensitivity to saturation temperature. The frictional pressure drop shows a linear dependence on the kinetic energy per unit volume of the refrigerant flow and therefore a quadratic dependence on the refrigerant mass flux.  相似文献   

6.
In this study, fundamental and practical influence of liquid refrigerant injection on the performance of a refrigerant scroll compressor has been investigated experimentally and theoretically. In the theoretical analysis, a compression model of vapor/liquid mixture is developed by taking account of heat transfer from the cylinder wall to suction, compression and injection refrigerant. An experiment has been done under the condition of keeping the oil temperature constant in order to investigate the fundamental influence of the liquid refrigerant injection on the compressor performance, and the results were compared with the theoretical ones. It was found that the injection basically increases the compression power and decreases the compressor efficiency, though the situation depends on the condition of the heat transfer to the injection refrigerant. And furthermore, the performance of the liquid refrigerant injection compressor under practical operating condition without controlling the oil temperature has been investigated. Under this condition, the compressor showed recovery and slight improvement of performance due to the decrease of the oil and cylinder temperatures by the injection. In addition, influence of the refrigerant injection on the oil viscosity and refrigerant solubility in the oil, which relate mechanical loss and reliability of the compressor, have been discussed.  相似文献   

7.
Refrigerant vapor-injection technique has been well justified to improve the performance of systems in refrigeration applications. However, it has not received much attention for air conditioning applications, particularly for air conditioning in hot climates and for heat pumping in cold climates. In this study, the performance of an 11 kW R410A heat pump system with a two-stage vapor-injected scroll compressor was experimentally investigated. The vapor-injected scroll compressor was tested with the cycle options of both flash tank and internal heat exchanger configurations. A cooling capacity gain of around 14% with 4% COP improvement at the ambient temperature of 46.1 °C and about 30% heating capacity improvement with 20% COP gain at the ambient temperature of −17.8 °C were found for the vapor-injected R410A heat pump system as compared to the conventional system which has the same compressor displacement volume.  相似文献   

8.
The objectives of this paper are to study the heat transfer characteristics for enhanced surface tubes in the pool boiling and to provide a guideline for the design conditions for the evaporator using HFC134a. The shape of tube surfaces, the wall superheat, and the saturation temperature are considered as the key parameters. Copper tubes (do = 19.05 mm) are treated with different helix angles and the saturation temperatures are controlled from 3 to 16 °C. It is found that the pool boiling heat transfer coefficient decreases with increasing the wall superheat. It is also found that boiling heat transfer coefficients for Turbo-II and Turbo-III are 1.5–3.0 times and 1.2–2.0 times higher than that for Turbo-I without the helix angle, respectively. The higher heat transfer performance from Turbo-II and Turbo-III can be explained by the “bubble detention” phenomenon on the surface without the helix angle for the Turbo-I. The experimental correlations for the pool boiling heat transfer on the present enhanced tubes without (Type I) and with the helix angle (Type II and Type III) are developed with the error bands of ±30%, respectively.  相似文献   

9.
A coupled heat and mass transfer model is developed to extract the transfer coefficients for falling-films from the measurements on a tubular absorber. The mass transfer coefficients obtained from the coupled model and the log-mean-difference approach agree within about 10%. For the heat transfer coefficient, the values given by the two models can differ quite significantly. The cooling water temperature distribution predicted by the coupled model agrees well with measurements. The transfer coefficients obtained from experimental measurements using the various methods reported in the literature show wide variations.  相似文献   

10.
This paper presents an overview of the issues and new results for in-tube condensation of ammonia in horizontal round tubes. A new empirical correlation is presented based on measured NH3 in-tube condensation heat transfer and pressure drop by Komandiwirya et al. [Komandiwirya, H.B., Hrnjak, P.S., Newell, T.A., 2005. An experimental investigation of pressure drop and heat transfer in an in-tube condensation system of ammonia with and without miscible oil in smooth and enhanced tubes. ACRC CR-54, University of Illinois at Urbana-Champaign] in an 8.1 mm aluminum tube at a saturation temperature of 35 °C, and for a mass flux range of 20–270 kg m−2 s−1. Most correlations overpredict these measured NH3 heat transfer coefficients, up to 300%. The reasons are attributed to difference in thermophysical properties of ammonia compared to other refrigerants used in generation and validation of the correlations. Based on the conventional correlations, thermophysical properties of ammonia, and measured heat transfer coefficients, a new correlation was developed which can predict most of the measured values within ±20%. Measured NH3 pressure drop is shown and discussed. Two separated flow models are shown to predict the pressure drop relatively well at pressure drop higher than 1 kPa m−1, while a homogeneous model yields acceptable values at pressure drop less than 1 kPa m−1. The pressure drop mechanism and prediction accuracy are explained though the use of flow patterns.  相似文献   

11.
A cryogenic loop heat pipe (CLHP) has been developed for future aerospace applications at the Technical Institute of Physics and Chemistry (TIPC). It has been demonstrated that this CLHP, when placed horizontally, can operate in liquid-nitrogen temperature range and have a heat transfer capability of up to 12 W with proper working fluid inventory. This paper presents some particular characteristics of the CLHP when the compensation chamber is half-filled with liquid-phase working fluid before startup. The device has been tested at different orientations using nitrogen as the working fluid in order to compare its thermal behavior, specially related to the heat transfer capability, the operation temperature and the thermal resistance, as well as to investigate its operational characteristics under power level as low as 1 W. Tests were performed for the CLHP at horizontal position and with the liquid line 3.4 and 6.4 cm below the vapor line, respectively. The experimental results show the operationability of the CLHP tested at three orientations and tests with the liquid line 6.4 cm below the vapor line show lower operation temperatures and higher heat transfer capability.  相似文献   

12.
Convective boiling heat transfer experiments were performed in horizontal minichannels with binary mixture refrigerant, R-410A. The test section is made of stainless steel tubes with inner diameters of 1.5 mm and 3.0 mm and with lengths of 1500 mm and 3000 mm, respectively, and is uniformly heated by applying electric current directly to the tubes. Local heat transfer coefficients were obtained for a heat flux range of 10–30 kW m−2, a mass flux range of 300–600 kg m−2 s−1, and quality ranges of up to 1.0. The experimental results were mapped on Wang et al.'s (C.C. Wang, C.S. Chiang, D.C. Lu, Visual observation of two-phase flow pattern of R-22, R-134a, and R-407C in a 6.5-mm smooth tube, Experimental, Thermal and Fluid Science 15 (1997) 395–405) and Wojtan et al.'s (L. Wojtan, T. Ursenbacher, J.R. Thome, Investigation of flow boiling in horizontal tubes: part I – a new diabatic two-phase flow pattern map, International Journal of Heat and Mass Transfer 48 (2005) 2955–2969) flow pattern maps to observe the flow regimes. Laminar flow appears in flow with minichannels. A new boiling heat transfer coefficient correlation based on the superposition model for R-410A was developed with 11.20% mean deviation; it showed a good agreement between the measured data and the calculated heat transfer coefficients.  相似文献   

13.
This paper studies refrigeration cycles in which plate heat exchangers are used as either evaporators or condensers. The performance of the cycle is studied by means of a method introduced in previous papers which consists of assessing the goodness of a calculation method by looking at representative variables such as the evaporation or the condensation temperature depending on the case evaluated. This procedure is also used to compare several heat transfer coefficients in the refrigerant side. As in previous works the models of all the cycle components are considered together with the heat exchanger models in such a way that the system of equations they provide is solved by means of a Newton–Raphson algorithm. Calculated and measured values of the evaporation and the condensation temperatures are also compared. The experimental results correspond to the same air-to-water heat pump studied in other papers and they have been obtained by using refrigerants R-22 and R-290.  相似文献   

14.
Ice slurry performance in a concentric corrugated tube heat exchanger is experimentally studied in this work in order to compare experimental results to theoretical prediction obtained using the correlations proposed in previous papers. Once the validity of those correlations is verified, the behaviour of the studied heat exchanger is analyzed for different ice slurry flow conditions and compared to the results obtained when a heterogeneous storage is used and only carrier fluid flows through the heat exchanger. According to the performance evaluation criterion used – variation in heat transfer rate for equal pressure drop and surface area – the most remarkable conclusion obtained is that slurry improves the behaviour of the heat exchanger studied for all the cases analyzed, although the increase in heat transfer rate is always lower than 15%, being in most cases lower than 5%.  相似文献   

15.
This paper presents the heat transfer characteristics obtained from an experimental investigation on flow boiling of n-pentane across a horizontal tube bundle. The tubes are plain with an outside diameter of 19.05 mm and the bundle arrangement is inverse staggered with a pitch to diameter ratio of 1.33. The test conditions consist of reduced pressure between 0.006 and 0.015, mass velocity from 14 to 44 kg/m2s, heat flux up to 60 kW/m2 and vapor quality up to 60%. The convective evaporation is found to have a significant effect on the heat transfer coefficient, coexisting with nucleate boiling. An asymptotic model allows the prediction of the heat transfer data with a fitted value of n=1.5. A strong mass velocity effect is observed for the enhancement factor, implying that the correlations available from the literature for the convective evaporation will fail in predicting the present data. This effect decreases as the mass velocity increases.  相似文献   

16.
Experiments were performed on the convective boiling heat transfer in horizontal minichannels with CO2. The test section is made of stainless steel tubes with inner diameters of 1.5 and 3.0 mm and with lengths of 2000 and 3000 mm, respectively, and it is uniformly heated by applying an electric current directly to the tubes. Local heat transfer coefficients were obtained for a heat flux range of 20–40 kW m−2, a mass flux range of 200–600 kg m−2 s−1, saturation temperatures of 10, 0, −5, and −10 °C and quality ranges of up to 1.0. Nucleate boiling heat transfer contribution was predominant, especially at low quality region. The reduction of heat transfer coefficient occurred at a lower vapor quality with a rise of heat flux, mass flux and saturation temperature, and with a smaller inner tube diameter. The experimental heat transfer coefficient of CO2 is about three times higher than that of R-134a. Laminar flow appears in the minichannel flows. A new boiling heat transfer coefficient correlation that is based on the superposition model for CO2 was developed with 8.41% mean deviation.  相似文献   

17.
Carbon dioxide is again becoming an important refrigerant. While the thermophysical properties are well known there is a lack of data on its heat transfer characteristics.

In this study, heat transfer coefficients for nucleate boiling of carbon dioxide are determined using a standard apparatus for the investigation of pool boiling based on a set-up from Karlsruhe [D. Gorenflo, J. Goetz, K. Bier. Vorschlag für eine Standard-Apparatur zur Messung des Wärmeübergangs beim Blasensieden. Wärme-und Stoffübertragung 16 (1982), 69–78; J. Goetz, Entwicklung und Erprobung einer Normapparatur zur Messung des Wärmeübergangs beim Blasensieden. Dissertation Universität Karlsruhe (1980).] and built at our institute. Electrically heated horizontal cylinders with an outer diameter of 16 mm and a length of 100 mm are used as heating elements. Measurements with constant heat flux are performed for different wall materials and surface roughnesses. The heat transfer is investigated within the pressure range of 0.53≤ p ≤1.43 MPa (0.072≤ p/pc ≤0.190) and a temperature range of −56≤ t ≤−30 °C, respectively. Heat fluxes of up to 80,000 W m−2 are applied.

The influences of wall material and roughness on the heat transfer coefficient are evaluated separately. The obtained coefficients are compared to generally accepted correlations and to experimental results of other authors, who used similar configurations with copper tubes and carbon dioxide. These are the only previous experimental data, which could be found. Results for copper, stainless steel and aluminium as wall materials are presented.  相似文献   


18.
CO2 flow condensation heat transfer coefficients and pressure drop are investigated for 0.89 mm microchannels at horizontal flow conditions. They were measured at saturation temperatures of −15 and −25 °C, mass fluxes from 200 to 800 kg m−2 s−1, and wall subcooling temperatures from 2 to 4 °C. Flow patterns for experimental conditions were predicted by two flow pattern maps, and it could be predicted that annular flow patterns could exist in most of flow conditions except low mass flux and low vapor quality conditions. Measured heat transfer coefficients increased with the increase of mass fluxes and vapor qualities, whereas they were almost independent of wall subcooling temperature changes. Several correlations could predict heat transfer coefficients within acceptable error range, and from this comparison, it could be inferred that the flow condensation mechanism in 0.89 mm channels should be similar to that in large tubes. CO2 two-phase pressure drop, measured in adiabatic conditions, increased with the increase of mass flux and vapor quality, and it decreased with the increase of saturation temperature. By comparing measured pressure drop with calculated values, it was shown that several correlations could predict the measured values relatively well.  相似文献   

19.
A plate-type evaporator, working with natural refrigerant circulation, has been investigated both experimentally and theoretically. Motivated by the phase-out of ozone-depleting substances, HCFC22 was compared to HFC134a and two zeotropic refrigerant mixtures. The effect of different separator liquid levels, i.e. refrigerant flows, and its influence on heat transfer was also studied. The investigated plate-type evaporator consists of thirteen vertical flow channels and its size is 3.0 m × 0.5 m. The heat source for the evaporator is a falling water film on the outside of the plate. Experimental studies have been carried out using a test facility that enabled detailed measurements of heat transfer and pressure drop. Experiments were compared to results from a calculation method that simultaneously calculates heat transfer and pressure drop in a variable number of steps along the evaporator. The calculation method is based on a pressure drop correlation proposed by the VDI-Wärmeatlas and a heat transfer correlation for vertical tubes proposed by Steiner and Taborek. For different evaporator duties, heat transfer was over predicted by 12% for pure fluids by 15% for mixtures. Calculated pressure drops were well within ±5% of the measured values. Changes in heat transfer due to different flows were closely predicted by the proposed calculation method.  相似文献   

20.
The presence of oil in domestic heat pumps is an obstacle toward higher efficiency, particularly for enhanced surface evaporators and for advanced concepts based on two-stage cycles. Very compact direct driven radial compressors supported on oil-free bearings represent a promising alternative. This paper presents the derivation of the specifications, the choice for an appropriate refrigerant fluid and the design of a proof of concept prototype with the various tradeoffs between the impeller characteristics to follow the seasonal heat demand, the bearing and rotordynamics for a stable operation. Heat pump simulation results, the design of the impeller as well as the layout of the experimental facility and first experimental results are presented. An impeller with a tip diameter of 20 mm has been tested at rotational speeds of up to 210 krpm reaching pressure ratios in excess of 3.3 and efficiencies above 78%. The refrigerant chosen for this first experimental approach is HFC 134a.  相似文献   