首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo investigate the effect of long-term extended soft contact lens wear on limbal and central corneal cell morphology, and limbal architecture.MethodsEach participant attended a study visit involving in vivo confocal microscopy of central corneal and limbal epithelium. Scans were graded by five masked graders for three features: central epithelial irregularity, limbal epithelial irregularity and the prominence of palisades of Vogt. The variability of grades between different graders and the difference of grades between extended wearers and daily soft/non-contact lens wearers were assessed.ResultsNineteen participants (9 extended soft contact lens wearers and 10 daily soft/non-contact lens wearers) aged 31–65 years were enrolled in this study. Scans from 37 eyes were included in the analysis. Agreement between graders for each feature was moderate to good with inter class correlation >0.7. While there were no significant differences in central epithelial cell irregularity (p = 0.527) and the prominence of palisade of Vogt (p = 0.182) between extended or daily soft/non-contact lens wearers, limbal epithelial cell irregularity showed a trend with increased irregularity in extended soft contact lens wearers (p = 0.091).ConclusionsWhile no differences in limbal cell morphology and structure or central epithelial cell was found in this subjective grading study of extended wearers compared to daily soft/non-contact lens wearers, further studies using a larger sample size or a longitudinal study design are warranted.  相似文献   

2.

Purpose

To assess whether short-term soft contact lens wear alters the anterior eye surface.

Methods

Twenty-two neophyte subjects wore soft contact lenses for a period of five hours. Topography based corneo-scleral limbal radius estimates were derived from height measurements acquired with a corneo-scleral profilometer. Additionally, central corneal thickness (CCT), anterior chamber depth (ACD), corneal curvature radius (R) and white-to-white (WTW) diameter were acquired with an OCT-assisted biometer. Measurements were obtained without lens wear (baseline), immediately after lens removal following five hours of wear and three hours after lens removal.

Results

Short-term soft contact lens wear significantly modifies corneo-scleral limbal radius (mean ± SD: 130 ± 74 μm, p << 0.001) and the changes are repeatable. In contrast, the WTW diameter and R were not modified. ACD and CCT were significantly affected but no significant correlations were found between the increment of the limbal radius and the decrease in ACD and CCT. Limbal radius increment was reversed three hours after lens removal for 68% of the subjects but the time course of this reversal was not uniform.

Conclusions

It is possible to accurately quantify limbal radius changes as a consequence of soft contact lens wear. The increment in the limbal diameter could reach over 0.5 mm but that alteration does not correspond to changes in WTW diameter and it was not observable to the examiner using a slit lamp. Assessing topographical limbus after contact lens wear could be a tool to optimize the selection of the contact lens, from the perspective of anterior eye surface changes.  相似文献   

3.
Acquired limbal stem cell deficiency (LSCD) describes a condition in which the corneal limbal stem cells are altered or destroyed, typically due to ocular trauma, chronic allergy or inflammation. Idiopathic LSCD is a term used to describe limbal stem cell failure in the absence of any identifiable causative factor. While several cases of adult-onset LSCD have been identified previously, this case report describes a rare presentation of bilateral asymmetric idiopathic paediatric limbal stem cell deficiency in a sixteen-year-old male with an otherwise unremarkable ocular history.  相似文献   

4.
PurposeTo quantify the effect of short-term miniscleral contact lens wear on the anterior eye surface of healthy eyes, including cornea, corneo-scleral junction and sclero-conjuctival area.MethodsTwelve healthy subjects (29.9 ± 5.7 years) wore a highly gas-permeable miniscleral contact lens of 16.5 mm diameter during a 5-hour period. Corneo-scleral height profilometry was captured before, immediately following lens removal and 3 h after lens removal. Topography based corneo-scleral limbal radius estimates were derived from height measurements. In addition, elevation differences in corneal and scleral region were calculated with custom-written software. Sclero-conjuctival flattening within different sectors was analysed.ResultsShort-term miniscleral lens wear significantly modifies the anterior eye surface. Significant limbal radius increment (mean ± standard deviation) of 146 ± 80 μm, (p = 0.004) and flattening of −122 ± 90 μm in the sclero-conjuctival area, (p << 0.001) were observed immediately following lens removal. These changes did not recede to baseline levels 3 h after lens removal. The greatest anterior eye surface flattening was observed in the superior sector. No statistically significant corneal shape change was observed immediately following lens removal or during the recovery period.ConclusionsShort-term miniscleral contact lens wear in healthy eyes does not produce significant corneal shape changes measured with profilometry but alters sclero-conjuctival topography. In addition, sclero-conjuctival flattening was not uniformly distributed across the anterior eye.  相似文献   

5.
High Dk silicone hydrogel lenses have overcome many of the hypoxic problems associated with traditional extended wear and the popularity of continuous wear (up to 30 nights) with these lens types is increasing. Results from clinical trials indicate that the typical physiological changes associated with edema from conventional extended wear of low Dk/t lenses do not occur with continuous wear of silicone hydrogel lenses. These changes include neovascularization, striae, microcysts and an increase in bulbar and limbal hyperemia. It is perhaps not surprising though that a number of adverse events do still occur with silicone hydrogel lenses when they are worn on a continuous wear basis. These include inflammatory conditions such as contact lens-induced peripheral ulcers (CLPU), contact lens-induced acute red eye (CLARE), infiltrative keratitis (IK) and contact lens papillary conjunctivitis (CLPC). Other events such as superior epithelial arcuate lesions (SEAL) and localised CLPC may be due to mechanical influences. While these conditions are not sight threatening, they may be painful and are certainly inconvenient to both the patient and the practitioner. It is therefore very important that the signs and symptoms associated with these events be recognised in order that they may be accurately identified and appropriately managed. The purpose of this review article is to describe the pathophysiology, etiology, and clinical presentation of these adverse events when observed with continuous wear contact lenses and to discuss their associated risk factors and incidence. Clear management and treatment strategies are also presented and a number of approaches to minimize adverse events with continuous wear of silicone hydrogel contact lenses are suggested.  相似文献   

6.
BackgroundSince the introduction of Silicone hydrogel (SiHy) contact lenses 20 years ago, industry has continued to modify lens materials, designs, lens care products and manufacturing processes, striving to improve contact lens physiological performance, comfort, and convenience for wearers. The purpose of this study was to investigate whether the ocular health of habitual soft contact lens wearers today is better than it was in previous decades.MethodsBaseline ocular physiology data for 3624 participants from a The Brien Holden Vision Institute clinical trials database were retrospectively reviewed. Records were grouped into 3 time periods; A: >2 decades ago (1997–1999), B: one decade ago (2009–2014) and C: recent years (since 2015). Physiology data for both neophytes and habitual contact lens wearers included; bulbar, limbal and upper palpebral conjunctival redness, corneal and conjunctival staining and conjunctival indentation from contact lenses.ResultsCorneal staining levels are similar between neophytes and contact lens wearers at time points A and C but worse for contact lens wearers at time point B. Limbal redness was greater in contact lens wearers than in neophytes at time point A but at time points B and C they are not different to the non-contact lens wearing population. In recent years, most ocular physiological variables in habitual contact lens wearers are similar to neophytes.ConclusionsWhile there have been changes over the past two decades in ocular physiological responses to contact lens wear, it appears that ocular health with current day contact lens wear is similar to no lens wear in most respects.  相似文献   

7.
PurposeTo investigate conjunctival vascular density (VD) using Anterior Segment Optical Coherence Tomography Angiography (OCTA) in Scleral Contact Lens (ScCL) wearers.MethodsIn this cross-sectional study, the conjunctival blood VD was assessed using OCTA with an anterior segment lens adapter. The nasal surface of each eye (6 ×6 mm) was scanned to a depth of 800 μm with ScCL and fifteen minutes after removing the lens. Conjunctival VD was defined as the percentage of the scanned volume occupied by vessels in which blood flow was measured. Measures of limbal indentation were subjectively determined by two independent observers using Anterior Segment Optical Coherence Tomography (AS-OCT). Comparisons between VD measurements before and after ScCL removal and correlations between conjunctival VD, time of use, vault and indentation values were also investigated.ResultsA total of 23 patients (3 females, 20 males) with keratoconus, with a mean age (years±SD) of 38.74±10.38 were included in the study. VD was significantly higher without ScCL (71.75%±2.97) than VD measured with ScCL (69.81%±2.63), p=0.02. A moderately negative correlation was found between indentation and vault (r=-0.44, p<0.05) and a positive tendency regarding the time of wearing ScCL and indentation (r=0.11 and r=0.068, respectively).ConclusionsUsing OCTA with an anterior segment lens adapter, the ocular surface blood VD was imaged and assessed with good repeatability and reliability. This study presents a new possible application of OCTA to investigate and monitor conjunctival vasculature in ScCL wearers. This results cautiously suggest that the repeated use of ScCL can cause vascular alterations in conjunctiva of the eyes of ScCL wearers, possibly due to a hidden hypoxia caused by prolonged limbal indentation.  相似文献   

8.

Purpose

To investigate the effect of soft contact lenses (SCL) wearing modality and lens materials on the changes in conjunctival bulbar and limbal redness and conjunctival and corneal staining after two months of SCL wear. Comfort level was also analyzed.

Methods

In this longitudinal clinical trial, forty-seven neophyte myopic subjects were fitted with a monthly disposable lens (lotrafilcon-B or comfilcon-A or balafilcon-A) in one eye and a daily disposable lens (nelfilcon-A or stenofilcon-A or nesofilcon-A) in the other eye, randomly selected. Conjunctival bulbar and limbal redness and conjunctival and corneal staining were evaluated before and after lens wear. Effect of lens wearing modality and lens materials on these changes was also determined. Level of comfort was evaluated subjectively twice per day. Comfort level and reduction in end-of-day comfort were compared between different lens wearing modalities and materials.

Results

Bulbar and limbal redness and conjunctival and corneal staining were increased (p < 0.001) after lens wear, and changes were similar with daily and monthly disposable lens wear (p > 0.05). Limbal redness was associated with lens materials, and lotrafilcon-B induced the least among the studied lenses (p < 0.05). There was no significant association between the wearing modality and the average comfort level and reduction of end-of-day comfort (p > 0.05).

Conclusion

Two months of SCL wear increased conjunctival redness, conjunctival and corneal staining, which were not associated with the lens wearing modality. There was a reduction in end-of-day comfort, similar to daily and monthly lenses. The change in limbal redness and reduction in end-of-day comfort were associated with the characteristics of the lens material.  相似文献   

9.
PurposeThe aim of the current study is to assess, using new technologies, the interaction of four monthly silicone hydrogel contact lenses on the ocular surface and the comfort over 15 days of use.MethodsProspective cross-over, randomized and double-masked study including four materials (lotrafilcon-B, samfilcon-A , comfilcon-A and filcom-V3). Clinical examination was performed in the following order: tear meniscus height, first break-up of the tear film, the average time of all tear film breakup incidents, bulbar redness, limbal redness (Keratograph 5M ,Oculus, Germany); central corneal thickness (Pentacam, Oculus, Germany), thermography values (FLIR A325; FLIR Systems Inc., USA), and slit-lamp evaluations, including ocular surface staining. Finally, subjective comfort was obtained from Contact Lens Dry Eye Questionnaire-8.ResultsThe impact of contact lens wear on the ocular surface didn’t show statistically significant changes over time except for corneal and conjunctival staining grades on day 15 compared to day 1 for the comfilcon A group (P = .003 and P = .01, respectively). Contact lens stability and impact on the ocular surface during contact lens wear didn’t show statistically significant changes over time except in the case of the comfilcon A material with respect to the irritation item (P = .01).ConclusionsThese results suggest that the impact of monthly silicone hydrogel contact lens materials on the ocular surface after and during contact lens wear, contact lens stability over time, and subjective comfort did not reveal any significant changes over 15 days of use for any of the materials.  相似文献   

10.
During contact lens wear, tear film components such as lipids, mucins and proteins tend to deposit on and within the lens material and may cause discomfort, reduced vision and inflammatory reactions. The tear film protein that has attracted most interest when studying contact lens deposition is the small (14 kDa), positively charged protein lysozyme. Albumin, which is a much larger protein (66 kDa) with an overall net negative charge is also of interest, and shows very different adsorption patterns to lysozyme. The concentration of albumin in the tear film is relatively low compared to the concentration in blood serum, but this value increases markedly under various conditions, including when the eye is closed, during contact lens wear and in various dry eye states. Gaining an understanding of the manner in which albumin deposits on biomaterials is of importance for contact lens wear, as well as for other medical applications where HEMA-based materials are used for implants, artificial blood vessels or drug delivery devices. This review paper summarizes the impact of individual material compositions, water content, hydrophobicity and electrostatic attraction on the adsorption behavior of the protein albumin.  相似文献   

11.
Complications of scleral lens wear are not well documented or understood. While multiple studies focus on oxygen transmission during scleral lens wear and associated corneal swelling, little is known about the effects of varying scleral lens fitting relationships, especially when there is corneal interaction. Scleral lenses, by convention, are designed to completely clear the corneal surface and rest on the conjunctival and scleral tissue. However, some designs maximize oxygen transmission by reducing the lens diameter, thickness, and recommended corneal clearance.While the modifications increase oxygen transmission in any scleral lens design, they also distribute the lens mass closer to the limbus and make visualization of corneal clearance, especially narrow in the limbal region, more difficult. The sequelae from mechanical interaction between scleral lenses and the ocular surface, in particular the cornea, remain uncertain.This case series will describe corneal epithelial bullae, molding, and epithelial erosions as unintended scleral lens complications. These corneal changes corresponded to areas of contact lens-corneal bearing confirmed utilizing a combined scanning laser ophthalmoscopy (SLO) and anterior segment OCT. This case series will discuss epithelial bullae detection, their etiology, and suggestions for application of this information into scleral lens fitting protocols.  相似文献   

12.
PurposeTo report on the ocular health and safety of children fit with soft hydrogel daily-disposable contact lenses, and followed for 6-years in a double-masked clinical trial investigating the performance of a dual-focus contact lens designed to control myopia progression.MethodsChildren aged 8−12 years, naïve to contact lens wear, were enrolled across four international sites. During years 1–3, children were randomised to either MiSight® 1 day or Proclear® 1 day (both omafilcon A, CooperVision, Inc.). The lenses were identical in material and geometry except for the front optical zone design. At the end of year-3, all those wearing Proclear 1 day were switched to MiSight 1 day, therefore all wore MiSight 1 day in years 4−6. Subjects agreed to wear the lenses at least 10-hours/day, 6-days/week. After dispensing, study visits were at 1-week, 1-month, 6-months and every 6-months until 6-years. At each visit, ocular measurements and subjective responses were recorded. Biomicroscopy used 0–4 grading scales; grade 0 represented no findings.Results144 children were enrolled: 69F:75M; mean age 10.1 years; mean cycloplegic spherical-equivalent refraction -2.11D; ethnicities included 34 East-Asian, 12 West-Asian, and 79 Caucasian. 92 completed the 6-years. Only three subjects discontinued due to an ocular adverse event (AE). No contact lens related AEs were classified as serious. The incidence rate of infiltrative AEs was 0.61% (6.1/1000 wearing-years; 95%CI: 0.24%–1.57%). The most common biomicroscopy findings were limbal, bulbar and tarsal hyperaemia and tarsal roughness. 99% of all biomicroscopy findings were grade-1 or lower. After 6-years of lens wear, ocular health by biomicroscopy was similar to pre-lens wear.ConclusionsAcross the 6-years, there were no contact lens related serious AEs and biomicroscopy showed no significant changes. Results suggest that children this age can successfully wear daily-disposable hydrogel contact lenses with minimal impact on ocular physiology.  相似文献   

13.
PurposeTo evaluate the performance of a silicone hydrogel daily disposable lens in neophyte subjects over 12 months.MethodsSeventy four subjects with no previous contact lens experience were randomised to wear narafilcon A (1 DAY ACUVUE® TruEye™) lenses (LW group) or to wear no contact lenses (NLW group) for 12 months. Biomicroscopy (performed by a masked investigator), visual acuity and subjective response scores were recorded at an initial visit and six follow-up visits, in addition to lens fit and surface evaluation for the LW group. Comfort was recorded with SMS messaging.ResultsFifteen of the LW group discontinued before the end of the study, compared with six of the NLW group. Measured visual acuity was about half a line better for the NLW group as these subjects were provided with their full sphero-cylindrical over-refraction, compared to the LW group in their best spherical corrected contact lenses; subjective scores for vision were similar for the two groups. Bulbar conjunctival hyperaemia, limbal hyperaemia, corneal staining, conjunctival staining and papillary conjunctivitis were clinically equivalent for the two groups whereas conjunctival staining was higher in the LW group. Comfort scores assessed by SMS were equivalent for the LW and NLW groups; there was a measurable improvement in comfort during the first month of wear for the LW group.ConclusionThis work has demonstrated that modern soft lenses (narafilcon A daily disposable silicone hydrogel lenses) offer an excellent, comfortable form of vision correction, and are able to exhibit minimal alterations to ocular physiology.  相似文献   

14.
PurposeTo investigate the incidence and peak elevation of conjunctival prolapse during short-term open eye scleral lens wear and its association with lens fitting characteristics.MethodsTen young, healthy adults (mean age ± SD, 30 ± 4 years) wore a high Dk sealed scleral lens for 90 min with an initial central post-lens fluid reservoir thickness defined as low (144 ± 23 μm), medium (487 ± 63 μm), and high (726 ± 55 μm). Optical coherence tomography was used to quantify limbal clearance, lens settling, and changes in conjunctival thickness.ResultsThe incidence of conjunctival prolapse was 37% across all fluid reservoir thickness conditions, with 80% of participants exhibiting conjunctival prolapse at least once. Prolapse was observed more frequently nasally (73%) than temporally (27%) (p < 0.01). The peak prolapse elevation did not vary with fluid reservoir thickness condition or anatomical location (both p > 0.05). For the low fluid reservoir thickness condition, eyes with conjunctival prolapse had greater initial limbal clearance (97 ± 38 μm compared to 43 ± 34 μm, p = 0.01) and more settling after 90 min of lens wear (−85 ± 30 μm compared to −34 ± 29 μm, p < 0.01). Greater limbal settling was associated with a higher peak elevation of the conjunctival prolapse (r = 0.48, p = 0.02), but not with landing zone tissue compression (r = 0.22, p = 0.33) or the initial or final limbal fluid reservoir thickness asymmetry (r ≤ 0.07, p > 0.05).ConclusionConjunctival prolapse was commonly observed during short-term sealed scleral lens wear in healthy eyes. The peak elevation of the conjunctival prolapse was associated with the extent of limbal settling, but not landing zone tissue compression or fluid reservoir thickness asymmetry.  相似文献   

15.

Purpose

To summarize the research findings on the ocular surface profile, to provide a definition and a classification of the corneoscleral shape, and to offer guidelines in selecting scleral lens design.

Methods

The definition of rotational symmetry and rotational asymmetry was inquired and PubMed searches were conducted.

Results

The better understanding of the scleral contact lens comportment on the eye and the introduction of new diagnostic instruments to measure the anterior ocular surface have led to improve comprehension of corneoscleral contour formulating new scleral lens designs. The scleral lens landing zone is influenced by corneoscleral profile which may be rotationally symmetric and rotationally asymmetric. Corneal sagittal height, limbal shape, corneoscleral junction profile, corneal, limbal, and conjunctival angles, and scleral shape should be taken in consideration to prevent and manage fitting problems, such as air bubble formation, midday fogging, localized blanching, impingement, conjunctival prolapse, lens decentration, lens flexure, and to increase comfort, wearing time, overall satisfaction, and visual quality.

Conclusion

Corneoscleral shape may be considered rotationally symmetric including spherical, aspherical and toric profiles, and rotationally asymmetric including regular and irregular quadrants profiles. Each ocular surface contour requires a different landing zone design for an optimal fitting, vaulting properly over the cornea and limbus, and ideal alignment on the sclera. Further studies are still necessary to clarify many aspects of scleral lenses which are little known yet.  相似文献   

16.
PurposeTo examine the effects of long-term ultraviolet radiation (UVR) blocking wearing contact lenses on ocular surface health, eye focus and macular pigment.Method210 pre-presbyopic patients were recruited from Birmingham UK, Brisbane Australia, Hong Kong China, Houston USA and Waterloo Canada (n = 42 at each site). All patients had worn contact lenses for ≥ 5 years, half (test group) of a material incorporating a UVR-blocking filter. Ocular health was assessed using slit-lamp biomicroscopy and UV autofluorescence. Accommodation was measured subjectively with a push-up test and overcoming lens-induced defocus. Objective stimulus response and dynamic measures of the accommodative response were quantified with an open-field aberrometer. Macular pigment optical density (MPOD) was assessed using heterochromatic flicker photometry (MPS II).ResultsThe two groups of participants were matched for age, sex, race, body-mass-index, diet, lifestyle, UVR exposure, refractive error and visual acuity. Limbal (p = 0.035), but not bulbar conjunctival redness (p = 0.903) was lower in eyes that had worn UVR-blocking contact lenses compared to controls. The subjective (8.0 ± 3.7D vs 7.3 ± 3.3D; p = 0.125) and objective (F = 1.255, p = 0.285) accommodative response was higher in the test group, but the differences did not reach significance. However, the accommodative latency was shorter in eyes that had worn UVR-blocking contact lenses (p = 0.003). There was no significant different in MPOD with UVR filtration (p = 0.869).ConclusionsBlocking the transmission of UVR is beneficial in maintaining the eye’s ability to focus, suggesting that presbyopia maybe delayed in long-term UVR-blocking contact lenses wearers. These lenses also provide protection to the critical limbal region.  相似文献   

17.
PurposeTo study whether some ocular surface alterations could be associated with contact lens (CL) wearers suffering from CL discomfort (CLD) detected using the Contact Lens Dry Eye Questionnaire (CLDEQ)-8.MethodsForty-one soft CL wearers further classified into symptomatic CL wearers (SCLW) and asymptomatic CL wearers (ACLW) by the CLDEQ-8, and 20 non CL wearers (NCLW) were included. Tear osmolarity, slit-lamp biomicroscopy findings, tear film break-up time, corneal and conjunctival staining, and Schirmer test were performed 24 h after CL removal. Data were compared among groups using the analysis of variance and the Student t-test or the Kruskal-Wallis H and the Mann-Whitney U tests, applying the Bonferroni correction. Correlations between the CLDEQ-8 and the clinical signs were performed using the Spearman correlation coefficient.ResultsTwenty-four SCLW, 17 ACLW and 20 NCLW were recruited. There were significant differences among groups for tear osmolarity (p < 0.001), limbal hyperaemia (p = 0.014), and tarsal hyperaemia (p = 0.031). Pairwise comparisons revealed that SCLW and ACLW had higher tear osmolarity (p < 0.003, both comparisons) and limbal hyperaemia (p = 0.027 and p = 0.048, respectively) than NCLW. Moreover, SCLW had higher tarsal hyperaemia (p = 0.030) than NCLW. No significant correlations were found (p > 0.05).ConclusionThe CLDEQ-8 was ineffective to detect clinical alterations between SCLW and ACLW; therefore, the use of questionnaires alone remains being the best approach to detect CLD. The role of the tarsal conjunctiva in the development of CLD should be analyzed in future studies.  相似文献   

18.
The stillness obtained with head-to-back stunning results from the current depolarizing spinal neurones. The same effect can be achieved by sequentially applying a head stun, followed by a current through the heart to stop it and a current down the spinal cord to abolish movement. The level of speckle bruising for this sequential stun is lower than that associated with head-to-back stunning and is similar to that of head-to-foreleg stunning. After head-only stunning, current passed continuously down the spinal cord through a good contact at voltages around 40 V gave adequate stillness, which improved when the voltage was raised to 80 V. With a frequency of 14 Hz, 40 V presented no hazard to workers. After head-only stunning, a brief application of current down the entire spinal cord for 2-4 s at 110 V or greater also effectively suppressed movement. With legs as contact points voltages as high as 400 V were necessary. For effective animal stillness good electrode contact is necessary and electrodes should be placed as close to the spinal cord as possible. With a continuous current flowing the oesophagus remained closed until muscle exhaustion occurred; even with a brief current down the spinal cord, the oesophagus remained closed for at least 30 s. Low voltage stimulation in the form of a continuous current cannot replace high voltage stimulation, but can supplement it, and therefore could be incorporated into the electrical stimulation process. Head-only stunning, followed by a cut through the major blood vessels of the neck, is acceptable for Halal slaughter and is now in use commercially in New Zealand. Subsequent movement is suppressed by a spinal discharge at 400 V using leg contacts.  相似文献   

19.
A healthy corneal epithelium, which is essential for proper vision and protection from external pathogens, is continuously replenished throughout life by stem cells located at the limbus. In diseased or injured eyes, however, in which stem cells are deficient, severe ocular problems manifest themselves. These are notoriously difficult to manage and as a result the last 20 or so years has seen a number of therapeutic strategies emerge that aim to recover the ocular surface and restore vision in limbal stem cell deficient eyes. The dominant concept involves the generation of laboratory cultivated epithelial cell sheets expanded from small biopsies of the epithelial limbus (for patient or donors) or another non-corneal epithelial tissue such as the oral mucosa. Typically, cells are grown on sterilised human amniotic membrane as a substrate, which then forms part of the graft, or specially formulated plastic culture dishes from which cells sheets can be released by lowering the temperature, and thus the adherence of the plastic to the cells. Overall, clinical results are promising, as is discussed, with new cultivation methodologies and different cell lineages currently being investigated to augment the treatment options for visual disturbance caused by a corneal epithelial limbal stem cell deficiency.  相似文献   

20.
PurposeTo study the effect of daily disposable contact lens (DDCL) refitting in monthly contact lens (CL) wearers suffering from contact lens discomfort (CLD), and to assess if there is a placebo effect associated with this CLD intervention.MethodsSymptomatic CL wearers, according to the Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8 ≥ 12 points), were divided into two groups. The study group was provided with DDCLs (delefilcon A) and the control group with a masked pair of their habitual monthly CLs (placebo effect) and were assessed after one month. Then, the control group was provided with the same DDCLs and evaluated one month later. The symptoms were recorded with the CLDEQ-8 and global rating of change scale (GRCS). Non-invasive tear break-up time (NITBUT), conjunctival hyperaemia, fluorescein staining, and lid wiper epitheliopathy (LWE) were evaluated. Changes between visits, groups, and the effect of each intervention were analysed.ResultsThirty-one participants (mean age: 23.2 ± 5.3 years) were recruited. The study group (n = 14) showed an improvement of -39.6 ± 25.8 % (p < 0.001) in CLDEQ-8 and 31.3 ± 14.6 points in GRCS (p < 0.001) after one month of DDCL use, while no changes in clinical tests were found. In the control group (n = 17), symptoms improved significantly after wearing the masked monthly CL (CLDEQ-8: -26.1 ± 31.0 %, p = 0.03; GRCS: 14.9 ± 17.0, p = 0.002), however a worsening in bulbar (26.5 ± 40.0 %; p = 0.02) and limbal hyperaemia (21.6 ± 34.7 %, p = 0.02) and an improvement of -19.1 ± 37.0 % (p = 0.049) in LWE was found. When the control group was fitted with the DDCL, improvements in GRCS (20.5 ± 25.5, p = 0.02), NITBUT (37.9 ± 42.3 %, p = 0.002), and conjunctival staining (-47.1 ± 59.9 %, p = 0.005) were noted.ConclusionsRefitting symptomatic monthly CL wearers with Delefilcon A DDCL is effective in reducing symptoms related to CLD. However, clinicians and researchers must be aware of the existence of a placebo effect when assessing the effectiveness of any CL refitting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号