首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The goal of characterization of the proteome, while challenging in itself, is further complicated by the microheterogeneity introduced by posttranslational modifications such as glycosylation. A combination of liquid chromatography (LC), capillary electrophoresis (CE), and mass spectrometry (MS) offers the advantages of unique selectivity and high efficiency of the separation methods combined with the mass specificity and sensitivity of MS. In the current work, the combination of liquid-phase separations and mass spectrometry is demonstrated through the on-line coupling of electrospray ionization mass spectrometry (ESI-MS) and off-line coupling with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF-MS). LC/ESI-MS yields real-time results while maintaining the separation obtained from the LC analysis. CE/MALDI TOF-MS offers high-mass detection and extremely low detection limits. The unique separation selectivity of CE relative to reversed-phase HPLC separations of the members of a glycopeptide family was used to develop an integrated multidimensional analysis achieved by the off-line coupling of LC, CE, and MALDI TOF-MS. To demonstrate the applicability of these techniques to the characterization of the heterogeneity of posttranslational modifications present in glycoproteins, we will report on the study of the glycoforms present in a N-linked site in a single-chain plasminogen activator (DSPAα1).  相似文献   

2.
Capillary electrophoresis (CE) has been combined with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) and radionuclide detection to assay mass-limited biological samples. Nanovial sampling techniques enable injections into the CE capillary from 50 to 150-nL volume samples; after the separation, nanoliter fraction collection combines the CE effluent with a MALDI matrix and minimizes sample spreading, thus allowing both MALDI MS and radionuclide detection on the CE fractions. MALDI MS complements the elution time information of CE by providing accurate molecular mass data, and radionuclide detection provides zeptomole limits of detection with quantitative information. While MALDI MS detects all fully processed peptides at sufficient concentration, culturing the neuron in media containing 35S-Met provides selective radionuclide detection of newly synthesized methionine-containing peptides. The analysis and detection of the expected neuropeptides and hormones in a single 40-microm bag cell neuron from Aplysia californica with CE/MALDI MS/radionuclide detection demonstrates the ability of this hyphenated approach to work with chemically complex mass-limited samples.  相似文献   

3.
The hyphenation of gas chromatography and mass spectrometry (GC/MS) revolutionized organic analysis. In GC/MS coupling, usually electron impact ionization is applied, and molecules are identified by their fragment pattern. Although mass spectrometry in principle is a separation method, it is used predominantly as a spectrometric technique. However, if soft (i.e., fragmentation-free) ionization techniques are applied, the inherent separation character of MS is emphasized, which has similarities to a GC boiling point separation. By combining polar column GC separation and fast soft ionization time-of-flight mass spectrometry technology, a comprehensive separation of complex petrochemical samples can be obtained (GC x MS approach). Compounds of comparable physical-chemical properties are characteristically grouped together in a two-dimensional retention time-m/z representation. This resembles the separation characteristics of comprehensive two-dimensional gas chromatography (GC x GC) and, thus, represents a novel multidimensional separation approach. In this work, a gas chromatograph equipped with a polar separation column was coupled to a home-built laser ionization time-of-flight mass spectrometer. Laser-based, single-photon ionization was used for universal soft ionization and resonance-enhanced multiphoton ionization for selective ionization of aromatic compounds. A novel capillary-jet inlet system was used for the coupling. Multidimensional comprehensive analysis of complex petrochemical hydrocarbon samples using gas chromatography coupled to mass spectrometry with soft and selective photo ionization sources is first demonstrated.  相似文献   

4.
Glycopeptides prepared from 1 nmol of a mixture of glycoproteins, transferrin, and ribonuclease B by lysylendopeptidase digestion were isolated by lectin and cellulose column chromatographies, and then they were analyzed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry and MALDI-quadrupole ion trap (QIT)-TOF mass spectrometry which enables the performance of MS ( n ) analysis. The lectin affinity preparation of glycopeptides with Sambucus nigra agglutinin and concanavalin A provides the glycan structure outlines for the sialyl linkage and the core structure of N-glycans. Such structural estimation was confirmed by MALDI-TOF MS and MALDI-QIT-TOF MS/MS. Amino acid sequences and location of glycosylation sites were determined by MALDI-QIT-TOF MS/MS/MS. Taken together, the combination of lectin column chromatography, MALDI-TOF MS, and MALDI-QIT-TOF MS ( n ) provides an easy way for the structural estimation of glycans and the rapid analysis of glycoproteomics.  相似文献   

5.
W Tong  A Link  J K Eng  J R Yates 《Analytical chemistry》1999,71(13):2270-2278
A method to directly identify proteins in complex mixtures by solid-phase microextraction (micro-SPE)/multistep elution/capillary electrophoresis (CE)/tandem mass spectrometry (MS/MS) is described. A sheathless liquid-metal junction interface is used to interface CE and electrospray ionization MS/MS. A subfemtomole detection limit is achieved for protein identification through database searching using MS/MS data. The SPE serves as a semiseparation dimension using an organic-phase step-elution gradient in combination with the second separation dimension for increased resolving power of complex peptide mixtures. This approach improves the concentration detection limit for CE and allows more proteins in complex mixtures to be identified. A 75-protein complex from yeast ribosome is analyzed using this method and 80-90% of the proteins in the complex can be identified by searching the database using the MS/MS data from a complete analysis. This multidimensional CE/MS/MS methodology provides an alternative to multidimensional liquid chromatography/MS/MS for direct identification of small amounts of protein in mixtures.  相似文献   

6.
Wang J  Ma M  Chen R  Li L 《Analytical chemistry》2008,80(16):6168-6177
An off-line interface incorporating sheathless flow and counter-flow balance is developed to couple capillary electrophoresis (CE) to matrix-assisted laser desorption ionization Fourier transform mass spectrometry (MALDI FTMS) for neuropeptide analysis of complex tissue samples. The new interface provides excellent performance due to the integration of three aspects: (1) A porous polymer joint constructed near the capillary outlet for the electrical circuit completion has simplified the CE interface by eliminating a coaxial sheath liquid and enables independent optimization of separation and deposition. (2) The electroosmotic flow at reversed polarity (negative) mode CE is balanced and reversed by a pressure-initiated capillary siphoning (PICS) phenomenon, which offers improved CE resolution and simultaneously generates a low flow (<100 nL/min) for fraction collection. (3) The predeposited nanoliter volume 2,5-dihydroxybenzoic acid (DHB) spots on a Parafilm-coated MALDI sample plate offers an improved substrate for effective effluent enrichment. Compared with direct MALDI MS analysis, CE separation followed by MALDI MS detection consumes nearly 10-fold less sample (50 nL) while exhibiting 5-10-fold enhancement in S/N ratio that yields the limit of detection down to 1.5 nM, or 75 attomoles. This improvement in sensitivity allows 230 peaks detected in crude extracts from only a few pooled neuronal tissues and increases the number of identified peptides from 19 to 43 (Cancer borealis pericardial organs (n = 4)) in a single analysis. In addition, via the characteristic migration behaviors in CE, some specific structural and chemical information of the neuropeptides such as post-translational modifications and family variations has been visualized, making the off-line CE-MALDI MS a promising strategy for enhanced neuropeptidomic profiling.  相似文献   

7.
Mixtures of inorganic ions separated by capillary electrophoresis (CE) and ion exchange chromatography (IC) are detected by mass spectrometry (MS) using an ion spray atmospheric pressure ionization source. The selectable degree of ion-adduct declustering and molecular fragmentation in the MS interface region allows the system to be operated as an elemental analyzer or as a molecular detector suitable for oxidation state determinations. Both inorganic anions and cations (including alkalis, alkaline earths, transition metals, and lanthanides) are analyzed by CE-MS. A variety of CE separation buffers are evaluated for the cation analyses (e.g., creatinine, ammonium acetate, and tris[hydroxymethyl]aminomethane). Only one of the buffers (i.e., creatinine) can be used for CE-indirect UV detection. A CE capillary permanently coated with strong anion exchange sites and a pyromellitic acid buffer (suitable for indirect UV detection) is used for the inorganic anion separations. The coated column eliminates the need for buffer modifiers to reverse the flow in the capillary, which then reduces background noise and mass spectral complexity. The separation and detection of 13 inorganic anions are also accomplished by IC using an anion exchange column with a carbonate-bicarbonate mobile phase, on-line suppressed conductivity detection, and mass spectrometric detection.  相似文献   

8.
The separation of the glycoforms of erythropoietin (EPO) by capillary electrophoresis (CE) was recently published as a monograph by the European Pharmacopoeia (European Pharmacopoeia 4 2002, 1316, 1123-1128). Although the experimental CE conditions employed a background electrolyte containing additives suitable for on-line UV-absorption detection, they were not appropriate for on-line mass spectrometry (MS) detection. In this work, an attempt was made to investigate experimental conditions employing volatile electrolyte systems to achieve the separation and characterization of EPO glycoforms using CE and ESI-MS methodologies. The influence of several operating conditions, such as the coating of the internal walls of the capillary as well as the composition, concentration, and the pH of the separation buffer were investigated. The results demonstrated that when the internal walls of the capillaries were permanently coated with Polybrene and a buffer electrolyte containing 400 mM of HAc-NH4Ac (acetic acid-ammonium acetate), pH 4.75, was used, a significantly reproducible separation was achieved for EPO glycoforms. Intact EPO was characterized by two mass spectrometry techniques: electrospray ionization (ESI-MS) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF-MS). The data demonstrated that MALDI-TOF-MS provided a good approximation to an average molecular mass of the EPO molecule. However, it was still necessary to carry out further separation of the intact EPO glycoforms in order to obtain molecular mass information when ESI-MS was used.  相似文献   

9.
X Jin  J Kim  S Parus  D M Lubman  R Zand 《Analytical chemistry》1999,71(16):3591-3597
The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions are stored in the ion trap and dc pulse injected into the reTOF-MS at a rate sufficient to maintain the separation achieved by CE. Using methodology generated by software and hardware developed in our lab, we can produce SWIFT (Stored Waveform Inverse Fourier Transform) ion isolation and TICKLE activation/fragmentation voltage waveforms to generate MS/MS at a rate as high as 10 Hz so that the MS/MS spectra can be optimized on even a 1-2 s eluting peak. In CE separations performed on tryptic digests of dogfish myelin basic protein (MBP) where eluting peaks 4-8 s wide are observed, it is demonstrated that an acquisition rate of 4 Hz provides > 20 spectra/peak and is more than sufficient to provide optimized MS/MS spectra of each of the eluting peaks in the electropherogram. The detailed structural analysis of dogfish MBP including several posttranslational modifications using CE-MS and CE-MS/MS is demonstrated using this method with < 10 fmol of material consumed.  相似文献   

10.
Frontal affinity chromatography (FAC) interfaced with electrospray mass spectrometry (ESI-MS) has been reported as a potential method for screening of compound mixtures against immobilized target proteins. However, the interfacing of bioaffinity columns to ESI-MS requires that the eluent that passes through the protein-loaded column have a relatively low ionic strength to produce a stable spray. Such low ionic strength solvents can cause serious problems with protein stability and may also affect binding constants and lead to high nonspecific binding to the column. Herein, we report on the interfacing of bioaffinity columns to matrix-assisted laser desorption/ionization (MALDI) MS/MS as a new platform for FAC/MS studies. Capillary columns containing a monolithic silica material with entrapped dihydrofolate reductase were used for frontal affinity chromatography of small-molecule mixtures. The output from the column was combined with a second stream containing alpha-cyano-hydoxycinnamic acid in methanol and was deposited using a nebulizer-assisted electrospray method onto a conventional MALDI plate that moved relative to the column via a computer-controlled x-y stage, creating a semipermanent record of the FAC run. The use of MALDI MS/MS allowed for buffers with significantly higher ionic strength to be used for FAC studies, which reduced nonspecific binding of ionic compounds and allowed for better retention of protein activity over multiple runs. Following deposition, MALDI analysis required only a fraction of the chromatographic run time, and the deposited track could be rerun multiple times to optimize ionization parameters and allow signal averaging to improve the signal-to-noise ratio. Furthermore, high levels of potential inhibitors could be detected via MALDI with limited ion suppression effects. Both MALDI- and ESI-based analysis showed similar retention of inhibitors present in compound mixtures when using identical ionic strength conditions. The results show that FAC/MALDI-MS should provide advantages over FAC/ESI-MS for high-throughput screening of compound mixtures.  相似文献   

11.
We have developed an on-line solid-phase extraction (SPE) method coupled to high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) for measuring trace levels of 18 perfluorinated chemicals (3 perfluorosulfonates, 8 perfluorocarboxylates, 7 perfluorosulfonamides) in serum. Without protein precipitation, only dilution with 0.1 M formic acid, one aliquot of 100 microL of serum was injected into a commercial column switching system that allowed for concurrent SPE and HPLC-MS/MS acquisition. First, the analytes were concentrated on a C18 SPE column. Then, this column was placed automatically in front of a C8 analytic HPLC column for chromatographic separation of the analytes. Detection and quantification were done using negative-ion TurboIonSpray ionization, a variant of electrospray ionization, MS/MS. Excellent recovery was achieved for all analytes including the volatile sulfonamide derivatives that could not be determined before using traditional off-line SPE methods. The high throughput and low limits of detection (0.05-0.8 ng/mL) using a small sample volume (100 microL of serum) and isotope dilution quantification make this method suitable for large-scale epidemiologic studies.  相似文献   

12.
Microprobe laser desorption/laser ionization mass spectrometry (microL(2)MS) is a sensitive and selective technique that has proven useful in the qualitative and semiquantitative detection of trace organic compounds, particularly polycyclic aromatic hydrocarbons (PAHs). Recent efforts have focused on developing microL(2)MS as a quantitative method, often by measuring the ratio of signal strength of an analyte to an internal standard. Here, we present evidence of factors that affect these ratios and thus create uncertainty and irreproducibility in quantification. The power and wavelength of the desorption laser, the delay time between the desorption and ionization steps, the power of the ionization laser, and the ionization laser alignment are all shown to change PAH ratios, in some cases by up to a factor of 24. Although changes in the desorption laser parameters and the delay time cause the largest effects, the ionization laser power and alignment are the most difficult parameters to control and thus provide the most practical limitations for quantitative microL(2)MS. Variation in ratios is seen in both synthetic poly(vinyl chloride) membranes and in "real-life" samples of Murchison meteorite powder. Ratios between similar PAHs vary less than those between PAHs that differ greatly in mass and structure. This finding indicates that multiple internal standards may be needed for quantification of samples containing diverse PAHs.  相似文献   

13.
We report on the construction and performance of a rotating ball interface for online coupling of capillary electrophoresis (CE) to matrix-assisted laser desorption ionization (MALDI) mass spectrometry with a time-of-flight (TOF) mass analyzer. The interface is based on a rotating stainless steel ball that transports samples from atmospheric pressure to the high vacuum of the mass spectrometer for desorption and ionization. The sample is deposited directly from a 50-microm-i.d. separation capillary onto the 19-mm ball that is rotating at 0.03 to 0.3 rpm. The sample is mixed online with matrix flowing from a separate 50-microm-i.d. capillary. The sample deposit dries before it is rotated past a polymer gasket and into the laser ionization region. Cleaning of the interface is accomplished using solvent-saturated felt, which cleans the ball surface after it rotates out of the ionization chamber. On-line CE-MALDI is demonstrated, and the performance is evaluated with the analysis of a mixture of three peptides: [Lsy8] vasopressin, substance P, and neurotensin. The rotating ball interface to MALDI-TOF MS demonstrated mass detection limit in the high femtomole range. The interface has negligible memory effect and shows no significant electrophoretic peak broadening when operated under optimized conditions.  相似文献   

14.
Moini M 《Analytical chemistry》2001,73(14):3497-3501
A split-flow capillary electrophoresis electrospray ionization mass spectrometry (CE/ESI-MS) interface is introduced, in which the electrical connection to the CE capillary outlet is achieved by diverting part of the CE buffer out of the capillary through an opening near the capillary outlet. The CE buffer exiting the opening contacts a sheath metal tube which acts as the CE outlet/ESI shared electrode. In cases in which the ESI source uses a metal needle, the voltage contact to the CE buffer is achieved by simply inserting the outlet of the CE capillary, which contains an opening, into the existing ESI needle (thereby greatly simplifying the CE to MS interfacing). As a result of the concentration-sensitive nature of ESI, splitting a small percentage of the CE flow has minimal effect on the sensitivity of detection. In addition, because the liquid is flowing through the opening and out of the capillary, there is no dead volume associated with this interface. Moreover, bubble formation due to redox reactions of water at the electrode does not effect CE/ESI-MS performance, because the actual metal/liquid contact occurs outside of the CE capillary. The sensitivity associated with a sheathless CE/MS interface, the ease of fabrication, universality, and lack of any dead volume make this design a superior CE/ESI-MS interface. The performance of this interface is demonstrated by analyses of a peptide standard and a protein digest using a variety of capillary dimensions.  相似文献   

15.
A novel approach using a combination of capillary electrophoresis/mass spectrometry (CE/MS) and off-line Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) revealed the structural details of acidic constituents of atmospheric organic aerosol. Both techniques utilized electrospray ionization (ESI), a soft ionization method, to facilitate the analysis of complex mixtures of organic compounds. CE/ESI-MS using an UltraTrol LN-precoated capillary and acidic background electrolytes at different pH values (2.5 and 4.7) was used to differentiate between weak (carboxylic) and strong (sulfonic) organic acids. On the basis of the electrophoretic mobility, m/z constraints from CE/ESI(-)-MS, and elemental composition information retrieved from off-line FTICR-MS, a variety of aliphatic and aromatic carboxylic acids (CHO-bearing molecules), nitrogen-containing carboxylic acids (CHON-bearing molecules), organosulfates (CHOS-bearing molecules), and (nitrooxy)organosulfates (CHONS-bearing molecules) were tentatively identified in the Oasis-HLB-extracted urban PM(2.5) (particulate matter with an aerodynamic diameter of <2.5 μm). The chemical known/unknown structures of detected compounds were confirmed by the semiempirical Offord model (effective mobility linearly correlated to Z/M(2/3)). The majorities of the identified compounds are products of atmospheric reactions and are known contributors to secondary organic aerosols.  相似文献   

16.
Today, two-dimensional mass spectrometry analysis of biological tissues by means of a technique called mass imaging, mass spectrometry imaging (MSI), or imaging mass spectrometry (IMS) has found application in investigating the distribution of moleculesMSI with matrix-assisted laser desorption/ionization (MALDI) and secondary ion MS (SIMS). However, the size of the matrix crystal and the migration of analytes can decrease the spatial resolution in MALDI, and SIMS can only ionize compounds with relatively low molecular weights. To overcome these problems, we developed a nanoparticle-assisted laser desorption/ionization (nano-PALDI)-based MSI. We used nano-PALDI MSI to visualize lipids and peptides at a resolution of 15 microm in mammalian tissues.  相似文献   

17.
18.
Direct interfacing of analytical high-speed countercurrent chromatography (HSCCC) to mass spectrometry (MS) was demonstrated for the first time, and its performance was evaluated in terms of chromatography and mass spectrometry. HSCCC/MS interface was based upon Frit electron ionization (EI), chemical ionization (CI), and fast atom bombardment (FAB). Separations were conducted by newly developed HSCCC-4000 with a 2.5-cm revolutional radius and 0.3 mm or 0.55 mm i.d. multilayer coiled column which is capable of operating at a maximum speed of 4000 rpm. To demonstrate the potential capability of HSCCC/frit MS, three indole auxin mixtures, two mycinamicin (macrolide antibiotics) mixtures, and a colistin complex (peptide antibiotics) were analyzed under HSCCC/frit EI, CI, and FABMS conditions, respectively. The data obtained indicated that interfacing to frit/MS does not adversely affect the chromatographic resolution and mass spectra provide structural information. The HSCCC system interfaced with a frit-equipped mass spectrometer will offer a new dimension in the separation of biologically important substances.  相似文献   

19.
2-Aminobenzamide-derivatized oligosaccharides were separated by three lectin column chromatographies and then subjected to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for structural characterization of the carbohydrates. The combination of sequential exoglycosidase digestion and MALDI-TOF MS greatly facilitates the monosaccharide sequencing and is more feasible than size-exclusion column chromatography in terms of the time consumed and the laboriousness of the procedure. By this strategy, microsequencing of 2-3 pmol of oligosaccharide derivatives could be achieved. Furthermore, spectra obtained by the post source decay (PSD) mode provide excellent sequence information. The relative intensities of metastable ions due to fragmentation at glycosidic linkages were different among linkage isomers of particular oligosaccharides. These results demonstrate that PSD analysis possesses significant potential for the estimation of glycosidic linkage in carbohydrate structures.  相似文献   

20.
Chen H  He M  Pei J  He H 《Analytical chemistry》2003,75(23):6531-6535
Quantitative analyses of synthetic polymers were accomplished using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Many factors have hindered the development of quantitative measurement of polymers via MALDI TOF MS, e.g., laser power, matrix, cation salt, and cocrystallization. By probing the optimal conditions, two sets of polymers were studied. Fair repeatability of the samples ensures acceptable results. In set 1, two poly(ethylene glycols) with different end groups showed equal desorption/ionization efficiencies. Two synthetic polymers in set 2 with different chemical properties resulted in different MALDI responses. Good linearity was achieved by plotting the relationship between the sample concentration ratio and the total signal intensity ratio in both sets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号