首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
18-Crown-6 ether (18C6) is evaluated as a shift reagent for multidimensional ion mobility spectrometry-mass spectrometry (IMS-IMS-MS) analyses of tryptic protein digests. In this approach, 18C6 is spiked into the solution-phase mixture and noncovalent peptide-crown ion complexes are formed by electrospraying the mixture into the gas phase. After an initial mobility separation in the first IMS drift region, complexes of similar mobility are selected and dissociated via collisional activation prior to entering the second drift region. These dissociation products (including smaller complexes, naked peptide ions, charge transfer products, and fragment ions) differ in mobility from their precursor ion complexes and (in favorable cases) from one another, allowing the mixture to resolve further in the second IMS region. We estimate an IMS-IMS peak capacity of ~2400 when shift reagents are employed. The approach is illustrated by examining a tryptic digest of cytochrome c and by identifying a peptide out of a complex mixture obtained by digestion of human plasma proteins. Disadvantages arising from increased complexity of data sets as well as other advantages of this approach are considered.  相似文献   

2.
Two-dimensional ion mobility spectrometry (IMS-IMS) coupled with mass spectrometry is examined as a means of separating mixtures of tryptic peptides (from myoglobin and hemoglobin). In this study, we utilize two distinct drift regions that are identical in that each contains He buffer gas at 300 K. The two-dimensional advantage is realized by changing the structures of the ions. As ions arrive at the end of the first drift region, those of a specified mobility are selected, exposed to energizing collisions, and then introduced into a second drift region. Upon collisional activation, some ions undergo structural transitions, leading to substantial changes in their mobilities; others undergo only slight (or no) mobility changes. Examination of peak positions and shapes for peptides that are separated in the first IMS dimension indicates experimental peak capacities ranging from approximately 60 to 80; the peak shapes and range of changes in mobility that are observed in the second drift region (after activation) indicate a capacity enhancement ranging from a factor of approximately 7 to 17. Thus, experimental (and theoretical) evaluation of the peak capacity of IMS-IMS operated in this fashion indicates that capacities of approximately 480 to 1360 are accessible for peptides. Molecular modeling techniques are used to simulate the range of structural changes that would be expected for tryptic peptide ions and are consistent with the experimental shifts that are observed.  相似文献   

3.
The development of a new ion mobility/mass spectrometry instrument that incorporates a multifield drift tube/ion funnel design is described. In this instrument, individual components from a mixture of ions can be resolved and selected on the basis of mobility differences prior to collisional activation inside the drift tube. The fragment ions that are produced can be dispersed again in a second ion mobility spectrometry (IMS) region prior to additional collisional activation and MS analysis. The result is an IMS-IMS analogue of MS-MS. Here, we describe the preliminary instrumental design and experimental approach. We illustrate the approach by examining the highly characterized bradykinin and ubiquitin systems. Mobility-resolved fragment ions of bradykinin show that b-type ions are readily discernible fragments, because they exist as two easily resolvable structural types. Current limitations and future directions are briefly discussed.  相似文献   

4.
Multidimensional ion mobility spectrometry (IMS-IMS and IMS-IMS-IMS) techniques have been combined with mass spectrometry (MS) and investigated as a means of generating and separating peptide and protein fragment ions. When fragments are generated inside a drift tube and then dispersed by IMS prior to MS analysis, it is possible to observe many features that are not apparent from MS analysis alone. The approach is demonstrated by examining fragmentation patterns arising from electrospray ion distributions of insulin chain B and ubiquitin. The multidimensional IMS approach makes it possible to select individual components for collisional activation and to disperse fragments based on differences in mobility prior to MS analysis. Such an approach makes it possible to observe many features not apparent by MS analysis alone.  相似文献   

5.
Three common gaseous anesthetics, halothane, enflurane, and isoflurane, were characterized by using ion mobility spectrometry (IMS)/mass spectrometry, and the dependence of product ion distributions on temperature and concentration was evaluated. At 40 degrees C and 500 ppb, negative ion mobility spectra in air largely consisted of monomer or dimer adducts with Br- or Cl- formed through dissociative electron capture of molecular neutrals. With increased temperature or decreased vapor concentrations, declustering and dissociation of product ions became pronounced. Ion-molecule reactions in the drift region of the IMS were evident as distortions in peak shape in the mass-resolved mobility spectra and in variable reduced mobilities for the same ions. A portable hand-held IMS was used for convenient, real-time detection of enflurane in respired gases following a controlled inhalation episode.  相似文献   

6.
A new ion mobility/time-of-flight mass spectrometer employing a high-pressure MALDI source has been designed and tested. The prototype instrument operates at a source/drift cell pressure of 1-10 Torr helium, resulting in a mobility resolution of approximately 25. A small time-of-flight mass spectrometer (20 cm) with a mass resolution of up to 200 has been attached to the drift cell to identify (in terms of mass-to-charge ratio) the separated ions. A simple tripeptide mixture has been separated in the drift tube and mass identified as singly protonated species. The ability to separate peptide mixtures, e.g., tryptic digest of a protein, is illustrated and compared to results obtained on a high-vacuum time-of-flight instrument.  相似文献   

7.
A new ion mobility instrument that incorporates a low-field region for ion separation and a high-field region for collisional activation is described. In this approach, mixtures of ions are separated based on differences in their mobilities in a approximately 20-cm-long low-field ( approximately 5 V cm(-)(1)) region of a drift tube. As the ions approach the drift tube exit, they are exposed to a large focusing potential drop; at high fields, ions are efficiently collisionally activated and dissociate as they exit the drift tube. We have demonstrated this approach by examining the fragmentation pattern for electrosprayed bradykinin ions. These studies show that the activation process is highly tunable; it is possible to modulate the field such that precursor ion mass spectra as well as several high-field collision-induced fragmentation patterns can be obtained. The approach also appears to be a simple means of activating protein ions, as demonstrated by examining electrosprayed myoglobin ions.  相似文献   

8.
A tandem quadrupole ion trap/ion mobility spectrometer (QIT/IMS) has been constructed for structural analysis based on the gas-phase mobilities of mass-selected ions. The instrument combines the ion accumulation, manipulation, and mass-selection capabilities of a modified ion trap mass spectrometer with gas-phase electrophoretic separation in a custom-built ion mobility drift cell. The quadrupole ion trap may be operated as a conventional mass spectrometer, with ion detection using an off-axis dynode/multiplier arrangement, or as an ion source for the IMS drift cell. In the latter case, pulses of ions are ejected from the trap and transferred to the drift cell where mobility in the presence of helium buffer gas is determined by the collision cross section of the ion. Ions traversing the drift cell are detected by an in-line electron multiplier and the data processed with a multichannel scaler. Preliminary data are presented on instrumental performance characteristics and the application of QIT/ IMS to structural and conformational studies of aromatic ions and protonated amine/crown ether noncovalent complexes generated via ion/molecule reactions in the ion trap.  相似文献   

9.
10.
An ion trap/ion mobility/quadrupole/collision cell/time-of-flight mass spectrometer that incorporates a differentially pumped orifice-skimmer cone region at the back of the drift tube has been developed for the analysis of peptide mixtures. The combined approach allows a variety of strategies to be employed for collisionally activating ions, and fragments can be monitored by subsequent stages of mass spectrometry in a parallel fashion, as described previously (Anal. Chem. 2000, 72, 2737). Here, we describe the overall experimental approach in detail. Applications involving different aspects of the initial mobility separation and various collisional activation and parallel sequencing strategies are illustrated by examining several simple peptide mixtures and a mixture of tryptic peptides from beta-casein. Detection limits associated with various experimental configurations and the utility for analysis of complex systems are discussed.  相似文献   

11.
Ion mobility spectrometry (IMS) is a rapid, gas-phase separation technique that exhibits excellent separation of ions as a standalone instrument. However, IMS cannot achieve optimal separation power with both small and large ions simultaneously. Similar to the general elution problem in chromatography, fast ions are well resolved using a low electric field (50-150 V/cm), whereas slow drifting molecules are best separated using a higher electric field (250-500 V/cm). While using a low electric field, IMS systems tend to suffer from low ion transmission and low signal-to-noise ratios. Through the use a novel voltage algorithm, some of these effects can be alleviated. The electric field was swept from low to high while monitoring a specific drift time, and the resulting data were processed to create a 'voltage-sweep' spectrum. If an optimal drift time is calculated for each voltage and scanned simultaneously, a spectrum may be obtained with optimal separation throughout the mobility range. This increased the resolving power up to the theoretical maximum for every peak in the spectrum and extended the peak capacity of the IMS system, while maintaining accurate drift time measurements. These advantages may be extended to any IMS, requiring only a change in software.  相似文献   

12.
An ion trap/ion mobility/quadrupole/time-of-flight mass spectrometer has been developed for the analysis of peptide mixtures. In this approach, a mixture of peptides is electrosprayed into the gas phase. The mixture of ions that is created is accumulated in an ion trap and periodically injected into a drift tube where ions separate according to differences in gas-phase ion mobilities. Upon exiting the drift tube, ions enter a quadrupole mass filter where a specific mass-to-charge (m/z) ratio can be selected prior to collisional activation in an octopole collision cell. Parent and fragment ions that exit the collision cell are analyzed using a reflectron geometry time-of-flight mass spectrometer. The overall configuration allows different species to be selected according to their mobilities and m/z ratios prior to collision-induced dissociation and final MS analysis. A key parameter in these studies is the pressure of the target gas in the collision cell. Above a critical pressure, the well-defined mobility separation degrades. The approach is demonstrated by examining a mixture of tryptic digest peptides of ubiquitin.  相似文献   

13.
The first examples of highly charged ions observed under intermediate pressure (IP) vacuum conditions are reported using laser ablation of matrix/analyte mixtures. The method and results are similar to those obtained at atmospheric pressure (AP) using laserspray ionization (LSI) and/or matrix assisted inlet ionization (MAII). Electrospray ionization (ESI), LSI, and MAII are methods operating at AP and have been shown, with or without the use of a voltage or a laser, to produce highly charged ions with very similar ion abundance and charge states. A commercial matrix-assisted laser desorption/ionization ion mobility spectrometry (IMS) mass spectrometry (MS) instrument (SYNAPT G2) was used for the IP developments. The necessary conditions for producing highly charged ions of peptides and small proteins at IP appear to be a pressure drop region and the use of suitable matrixes and laser fluence. Ionization to produce these highly charged ions under the low pressure conditions of IP does not require specific heating or a special inlet ion transfer region. However, under the current setup, ubiquitin is the highest molecular weight protein observed. These findings are in accord with the need to provide thermal energy in the pressure drop region, similar to LSI and MAII, to improve sensitivity and extend the types of compounds that produce highly charged ions. The practical utility of IP-LSI in combination with IMS-MS is demonstrated for the analysis of model mixtures composed of a lipid, peptides, and a protein. Further, endogenous multiply charged peptides are observed directly from delipified mouse brain tissue with drift time distributions that are nearly identical in appearance to those obtained from a synthesized neuropeptide standard analyzed by either LSI- or ESI-IMS-MS at AP. Efficient solvent-free gas-phase separation enabled by the IMS dimension separates the multiply charged peptides from lipids that remained on the delipified tissue. Lipid and peptide families are exceptionally well separated because of the ability of IP-LSI to produce multiple charging.  相似文献   

14.
Mobility labeling for parallel CID of ion mixtures   总被引:2,自引:0,他引:2  
An ion mobility/mass spectrometry technique has been developed to record collision-induced dissociation patterns for multiple ions in a parallel fashion. In this approach, a mixture of ions is separated in a drift tube on the basis of differences in mobilities through a buffer gas. As the ions exit the drift tube, they are accelerated into a collision cell and the ensuing fragment ions are dispersed by differences in mass-to-charge (m/z) ratios in a time-of-flight mass spectrometer. Fragment ions that are formed in the collision cell have drift times that are coincident with their antecedent parent ions, allowing the origin of all fragments formed from the mixture of ions to be determined. The approach is demonstrated by examining fragmentation patterns of the [M + H]+ parent and a series of a-, b-, and y-type fragments of [D-Ala2,3]methionine enkephalin.  相似文献   

15.
Ion mobility spectrometry (IMS) is capable of providing real-time analysis of several impurities in inert gases. Because of its poor peak resolution, the IMS is susceptible to peak interferences. Previous study has shown that the detection limit and accuracy of O2 measurement in N2 suffers from peak interference. In many applications, the interference can be avoided by selecting a proper drift gas. For N2 analysis, we have demonstrated that the peak interference of O2 can be eliminated by using Ar as a drift gas. The use of Ar changes the chemical reactions that occur inside the drift region and results in different product ions. The peaks of new product ions are well-separated and do not coincide with the peak representing O2.  相似文献   

16.
Pulsed-ionization miniature ion mobility spectrometer   总被引:3,自引:0,他引:3  
We have demonstrated a miniature ion mobility spectrometer (IMS) that employs single pulses of corona discharge ionization. IMS spectra of both positive and negative ions generated from ambient air were measured as a function of drift field under various ionization conditions. Ion mobility spectra were studied with various pulse widths for both positive and negative ions, giving insights into mechanisms and kinetics of corona discharge ionization used in the miniature IMS. A combination of a pulsed potential with a steady dc bias was used to generate ions in the miniature IMS. There was a threshold dc potential for ion generation for a given pulse height. The dc ionization threshold was found to decrease linearly with increasing pulse height.  相似文献   

17.
Traveling wave ion mobility spectrometry (TW IMS) is a new IMS method implemented in the Synapt IMS/mass spectrometry system (Waters). Despite its wide adoption, the foundations of TW IMS were only qualitatively understood and factors governing the ion transit time (the separation parameter) and resolution remained murky. Here we develop the theory of TW IMS using derivations and ion dynamics simulations. The key parameter is the ratio (c) of ion drift velocity at the steepest wave slope to wave speed. At low c, the ion transit velocity is proportional to the squares of mobility (K) and electric field intensity (E), as opposed to linear scaling in drift tube (DT) IMS and differential mobility analyzers. At higher c, the scaling deviates from quadratic in a way controlled by the waveform profile, becoming more gradual with the ideal triangular profile but first steeper and then more gradual for realistic profiles with variable E. At highest c, the transit velocity asymptotically approaches the wave speed. Unlike with DT IMS, the resolving power of TW IMS depends on mobility, scaling as K(1/2) in the low-c limit and less at higher c. A nonlinear dependence of the transit time on mobility means that the true resolving power of TW IMS differs from that indicated by the spectrum. A near-optimum resolution is achievable over an approximately 300-400% range of mobilities. The major predicted trends are in agreement with TW IMS measurements for peptide ions as a function of mobility, wave amplitude, and gas pressure. The issues of proper TW IMS calibration and ion distortion by field heating are also discussed. The new quantitative understanding of TW IMS separations allows rational optimization of instrument design and operation and improved spectral calibration.  相似文献   

18.
High-resolution ion mobility spectrometry has been combined with time-of-flight mass spectrometry for analysis of a combinatorial peptide library that is expected to contain 676 components. In this approach, the components of a mixture of three residue peptides, having the general form (D)Phe-Xxx-Xxx-CONH2 (where Xxx is randomized over 26 residues including 10 naturally occurring amino acids and 16 synthetic forms) were ionized by electrospray ionization. Ion mobility/time-of-flight distributions have been recorded for all ions using a nested drift(flight) time technique. The improvement in resolving power [(t/delta t) = 100-150 for singly charged ions] was illustrated by analysis of a mixture of tryptic digest peptides using high- and low-resolution instruments. The approach allows many components of the library (e.g., structural, sequence, and stereo isomers) that cannot be distinguished by mass spectrometry alone to be resolved. Impurities due to side reactions appear to be minimal, comprising < 10% of the total ion signal. Direct evidence for approximately 60-70% of the expected peptides is found. Variation in ion abundance for different components indicates that there are differences in solution concentrations or ionization efficiencies for the components.  相似文献   

19.
Traveling wave ion mobility spectrometers (TW IMS) operate at significantly higher fields than drift tube ion mobility spectrometers. Here we measured the fragmentation of the fragile p-methoxybenzylpyridinium ion inside the TW ion mobility cell of the first-generation SYNAPT HDMS spectrometer. The ion's vibrational internal energy was quantified by a vibrational effective temperature T(eff,vib), which is the mean temperature of the ions inside the cell that would result in the same fragmentation yield as observed experimentally. Significant fragmentation of the probe ion inside the TW IMS cell was detected, indicating that field heating of the ions takes place in TW IMS. For typical small molecule IMS conditions, T(eff,vib) = 555 ± 2 K. The variations of the effective temperature were studied as a function of the IMS parameters, and we found that T(eff,vib) decreases when the wave height decreases, when the pressure increases, or when the wave speed increases. The energy transfer efficiency of argon is higher than for He, N(2), or CO(2). With T(eff,vib) being directly related to the ion speed inside the TW IMS, our results also provide new insight on the ion movement in TW IMS. We also discuss the influence of field heating of ions for calibration and structural studies in TW IMS.  相似文献   

20.
A series of crown ethers, 12-crown-4, 15-crown-5, 18-crown-6, and dibenzo-30-crown-10, are examined as a possible means of shifting the mobilities of peptide ions. In this approach, a crown ether is added to a solution containing a mixture of peptides and is electrosprayed into the gas phase in order to create distributions of peptide-crown complexes. The ion complexes have different mobilities than the naked peptide ions, and the crown ether molecules appear to interact specifically with basic sites in the peptides thus providing some sequence selectivity. After the peptide-crown complexes are separated by ion mobility spectrometry, the ions can be collisionally activated to dissociate the complex (forming the naked peptide ions) prior to m/z analysis. The overall effect is that complex formation shifts peptide ions to different regions of the mobility spectrum, extending the ability to resolve components. The approach is illustrated by examining isobaric dipeptides as well as a combinatorial library containing 27 tripeptides. Cross sections for the series of crown ether ions and complexes that are observed are reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号