共查询到20条相似文献,搜索用时 0 毫秒
1.
Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equipped with a nanotip electron gun can provide images with higher spatial resolution and with better signal-to-noise ratio. This could present a considerable advantage over the current SEM electron gun technology if the tips are sufficiently long-lasting and stable for practical use. In this study, an older field-emission critical dimension (CD) SEM was used as an experimental test platform. Substitution of tungsten nanotips for the regular cathodes required modification of the electron gun circuitry and preparation of nanotips that properly fit the electron gun assembly. In addition, this work contains the results of the modeling and theoretical calculation of the electron gun performance for regular and nanotips, the preparation of the SEM including the design and assembly of a measuring system for essential instrument parameters, design and modification of the electron gun control electronics, development of a procedure for tip exchange, and tests of regular emitter, sharp emitter and nanotips. Nanotip fabrication and characterization procedures were also developed. Using a "sharp" tip as an intermediate to the nanotip clearly demonstrated an improvement in the performance of the test SEM. This and the results of the theoretical assessment gave support for the installation of the nanotips as the next step and pointed to potentially even better performance. Images taken with experimental nanotips showed a minimum two-fold improvement in resolution performance than the specification of the test SEM. The stability of the nanotip electron gun was excellent; the tip stayed useful for high-resolution imaging for several hours during many days of tests. The tip lifetime was found to be several months in light use. This paper summarizes the current state of the work and points to future possibilities that will open when electron guns can be designed to take full advantage of the nanotip electron emitters. 相似文献
2.
A scanning electron microscope (SEM) system equipped with a motor drive specimen stage fully controlled with a personal computer (PC) has been utilized for obtaining ultralow magnification SEM images. This modem motor drive stage works as a mechanical scanning device. To produce ultra-low magnification SEM images, we use a successful combination of the mechanical scanning, electronic scanning, and digital image processing techniques. This new method is extremely labor and time saving for ultra-low magnification and wide-area observation. The option of ultra-low magnification observation (while maintaining the original SEM functions and performance) is important during a scanning electron microscopy session. 相似文献
3.
Tang CY Huang RN Kuo-Huang LL Kuo TC Yang YY Lin CY Jane WN Chen SJ 《Microscopy research and technique》2012,75(2):103-111
A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. 相似文献
4.
Common and different aspects of scanning electron microscope (SEM) and scanning ion microscope (SIM) images are discussed from a viewpoint of interaction between ion or electron beams and specimens. The SIM images [mostly using 30 keV Ga focused ion beam (FIB)] are sensitive to the sample surface as well as to low-voltage SEM images. Reasons for the SIM images as follows: (1) no backscattered-electron excitation; (2) low yields of backscattered ions; and (3) short ion ranges of 20–40nm, being of the same order of escape depth of secondary electrons (SE) [=(3–5) times the SE mean free path]. Beam charging, channeling, contamination, and surface sputtering are also commented upon. 相似文献
5.
Environmental scanning electron microscopy (ESEM) modifies conventional SEM through the use of a partial gas pressure in the microscope specimen chamber. Like conventional SEM, it has the resolution to image structure on the submicron lengthscale, but can also tolerate hydrated specimens if water vapour is used in the specimen chamber. This ability to image aqueous specimens leaves ESEM uniquely placed to study in situ drying in polymer latexes. However, there are two key practical difficulties associated with in situ drying. First, the size of the latex particles: larger latex particles are typically around 500 nm in diameter. Although ESEM can resolve structure on this lengthscale without difficulty, the magnification required results in radiation damage of the specimen due to the electron beam. This means that a given region can be imaged only once during film formation, so the evolution of particular features cannot be followed. Second, the change from ambient temperature and pressure to the ESEM conditions of 7 degrees C and 7.5 torr (100 Pa) can subject the specimen to a very high evaporation rate, which can disrupt film formation. The inclusion of a drop of water in the specimen chamber is shown largely to alleviate this, enabling successful imaging of film formation in the lacquer. Instead of the polymer latex itself, this work concentrates on a matting lacquer with silica inclusions. The silica matting agent particles are 1-10 microm in size, allowing for a lower magnification to be used, massively reducing specimen damage. Furthermore, the contrast during drying is much enhanced in the presence of silica. The images reveal the silica as bright regions against a darker background of polymer and water. Film formation shows the transition from a uniform, featureless aqueous solution to a polymer film with silica particles present on the surface. The appearance of individual silica particles can be followed. The particles are generally revealed quite early, after a few minutes of drying time. As film formation progresses, these same particles appear larger and more distinct. Few new particles are revealed at longer film formation times. 相似文献
6.
详细分析FEI Nova NanoSEM 230扫描电镜的潘宁规的维修过程,为积累处理扫描电镜故障的经验提供便利,对类似型号的维修有一定的借鉴意义。 相似文献
7.
Accurate spatial measurements in a scanning electron microscope (SEM) require calibration of the magnification as a function of working distance and microscope operating conditions. This work presents the results of the calibration of an environmental SEM for the accurate spatial measurement of dimensions and areas in experiments, both for the measurement of strain in steel specimens under applied loads and the measurement of dimensional changes in timber with changes in relative humidity. 相似文献
8.
We describe a PC-based active-capture system for recording digital images from a scanning electron microscope. The system is based on a National Instruments data-acquisition board and a Pentium computer, controlled by software that we have written in Visual Basic. 相似文献
9.
A device has been developed and used successfully on two models of the environmental scanning electron microscope that allows low-magnification imaging of about 30x, significantly better than the original 200x low-magnification imaging limit. This was achieved by using an additional aperture to limit the pressure at a point where it will not block the electron beam, and a larger aperture plate for the combination final aperture/secondary electron signal collection surface that also does not block the electron beam significantly. 相似文献
10.
Using small Pb crystals deposited in situ on a partially contaminated Si (100) crystal, we demonstrate that a commercial scanning electron microscope (SEM) can easily be converted into a scanning low-energy electron microscope (SLEEM). Although the contrast mechanism is much more complicated than that in nonscanning LEEM because not only one diffracted monochromatic beam and its close environment are used for imaging, but several diffracted beams and a wide energy spectrum of electrons of different origin (secondary electrons, inelastically andelastically scattered electrons) are used, SLEEM is a valuable addition to the standard SEM because it provides an additional structure- and orientation-sensitive contrast mechanism in crystalline materials, a low sampling depth, and high intensity at low energies. 相似文献
11.
Recent software and hardware advances in the field of electron backscatter diffraction have led to an increase in the rate of data acquisition. Combining automated stage movements with conventional beam control have allowed researchers to collect data from significantly larger areas of samples than was previously possible. This paper describes a LabVIEW? and AutoIT© code which allows for increased flexibility compared to commercially available software. The source code for this software has been made available in the online version of this paper. 相似文献
12.
A new type of non‐linear filter for digital images has been developed. By using distance transforms we estimate the average point spread function for a set of fibre cross‐sectional images. Then a fast filter technique, based on lookup tables for distance layers, attenuates the uneven background response from the scanning electron microscope. Compared to the convolution‐based techniques that we tried, this approach caused less blurring effects on our fibre images and also made the background pixels more homogeneous. The only assumption we make is that we can roughly segment the background pixels by using a pixel‐wise classifier. Although the assumption that the uneven background response can be described by a circular point spread function is only approximately true in the case discussed here, this method greatly attenuates the effect and provides a fast and general filtering method that can also be of use for other applications. 相似文献
13.
14.
We have developed a method for observing transverse swelling of cellulosic fibres in the environmental scanning electron microscope (ESEM). The presence of liquid water in the ESEM specimen chamber allows the observation of in situ hydration without the need for coating, freezing, or drying of the sample. For reproducibility of the hydration and dehydration process, specialised mounting techniques are required and control of the conditions for condensation and evaporation of liquid water is necessary. The sensitivity of these cellulosic materials to the electron beam was investigated, showing that some damage mechanisms are enhanced by the continual presence of water vapour in the chamber. A discussion is presented of the effect of various experimental parameters on the extent and time of onset of the damage, and we outline steps to maximise the amount of useful experimental time for these fibres. 相似文献
15.
A portable scanning electron microscope (SEM) column design is presented which makes use of permanent magnets. Simulation results predict that such an SEM column is feasible and that it can be compact. The column height is typically less than 12 cm. The column is designed to be modular, so that it can fit onto a wide range of different specimen chamber types, and can also be readily replaced. 相似文献
16.
Eric Doehne 《Scanning》1997,19(2):75-78
Spurious x-ray signals, which previously prevented high-resolution energy-dispersive x-ray analysis (EDS) in the environmental scanning electron microscope (ESEM), can be corrected using a simple method presented here. As the primary electron beam travels through the gas in the ESEM chamber, a significant fraction of the primary electrons is scattered during collisions with gas molecules. These scattered electrons form a broad skirt that surrounds the primary electron beam as it impacts the sample. The correction method assumes that changes in the width of the electron skirt with pressure are less important than changes in the skirt intensity; this method works as follows: The influence of the gas on the overall x-ray data is determined by acquiring EDS spectra at two pressures. Subtracting the two spectra provides us with a difference spectrum which is then used to correct the original data, using extrapolation, back to the x-ray spectrum expected under high-vacuum conditions. Low-noise data are required to resolve small spectral peaks; however, the principle should apply equally to x-ray maps and even to low-magnification images. 相似文献
17.
A scanning electron microscope (SEM) simulator was developed based on the models used in the MONSEL software. This simulator extends earlier work by introducing an object-oriented framework and adding optimization methods based on precomputation of electron trajectories. Several optimizations enable speedup by factors of 5-100 on a single processor over unoptimized simulations without introducing additional approximations. The speedup for a particular surface depends on the self-similarity of the surface at the scale of the electron penetration depth. We further accelerate by parallelizing the calculations for a total speedup of about 100-2000 on 30 processors. The goal of this work was to create a system capable of simulating a quantitatively accurate SEM image of a relatively unconstrained surface. Results of this work include simulation software, optimization algorithms, performance measurements with various optimizations, and examples of simulated images. 相似文献
18.
A simple, low-investment device has been developed that allows the collection of backscattered electrons (BSEs) and specimen current (SC) signals for imaging purposes and current measurement. Originally, this system was designed for detection, measurement, and display of specimen current, with a video signal output whose level was modulated by this current. Eventually, a BSE detector was developed, using a graphite disk (about 8 cm in diameter) to collect the BSEs. The disk was mounted on a Philips SEM 5O5, attached and concentrically to the final lens aperture. This configuration gives a large solid angle of collection. The collected charge is further processed by the same electronics used in the aforementioned SC detection system. Electron channeling, topographic contrast with BSE, and material contrast with BSE and SC images can be obtained with reasonably good edge definition. 相似文献
19.
Jeremiah R. Lowney 《Scanning》1996,18(4):301-306
Two computer codes for simulating the backscattered, transmitted, and secondary-electron signals from targets in a scanning electron microscope are described. The first code, MONSEL-II, has a model target consisting of three parallel lines on a three-layer substrate, while the second, MONSEL-III, has a model target consisting of a two-by-two array of finite lines on a three-layer substrate. Elastic electron scattering is determined by published fits to the Mott cross section. Both plasmon-generated electrons and ionized valence electrons are included in the secondary production. An adjustable quantity, called the residual energy loss rate, is added to the formula of Joy and Luo to obtain the measured secondary yield. The codes show the effects of signal enhancement due to edge transmission, known as blooming, as well as signal reduction due to neighboring lines, known as the “black-hole” effect. 相似文献
20.
The role of induced contrast in images obtained using the environmental scanning electron microscope
Generation of contrast in images obtained using the environmental scanning electron microscope (ESEM) is explained by interpretation of images acquired using the gaseous secondary electron detector (GSED), ion current, and the Everhart-Thornley detector. We present a previously unreported contrast component in GSED and ion current images attributed to signal induction by changes in the concentration of positive ions in the ESEM chamber during image acquisition. Changes in positive ion concentration are caused by changes in electron emission from the sample during image acquisition and by a discrepancy between the drift velocities of negative and positive charge carriers in the imaging gas. The proposed signal generation mechanism is used to explain contrast reversal in images produced using the GSED and ion current signals and accounts for discrepancies in contrast observed, under some conditions, in these types of images. Combined with existing models of signal generation in the ESEM, the proposed model provides a basis for correct interpretation of ESEM images. 相似文献