共查询到20条相似文献,搜索用时 46 毫秒
1.
Pandji Triadyaksa Astri Handayani Hildebrand Dijkstra Kadek Y. E. Aryanto Gert Jan Pelgrim Xueqian Xie Tineke P. Willems Niek H. J. Prakken Matthijs Oudkerk Paul E. Sijens 《Magma (New York, N.Y.)》2016,29(1):17-27
Objectives
Reproducibility of myocardial contour determination in cardiac magnetic resonance imaging is important, especially when determining T2* values per myocardial segment as a prognostic factor of heart failure or thalassemia. A method creating a composite image with contrasts optimized for drawing myocardial contours is introduced and compared with the standard method on a single image.Materials and methods
A total of 36 short-axis slices from bright-blood multigradient echo (MGE) T2* scans of 21 patients were acquired at eight echo times. Four observers drew free-hand myocardial contours on one manually selected T2* image (method 1) and on one image composed by blending three images acquired at TEs providing optimum contrast-to-noise ratio between the myocardium and its surrounding regions (method 2).Results
Myocardial contouring by method 2 met higher interobserver reproducibility than method 1 (P < 0.001) with smaller Coefficient of variance (CoV) of T2* values in the presence of myocardial iron accumulation (9.79 vs. 15.91 %) and in both global myocardial and mid-ventricular septum regions (12.29 vs. 16.88 and 5.76 vs. 8.16 %, respectively).Conclusion
The use of contrast-optimized composite images in MGE data analysis improves reproducibility of myocardial contour determination, leading to increased consistency in the calculated T2* values enhancing the diagnostic impact of this measure of iron overload.2.
Pandji Triadyaksa Niek H. J. Prakken Jelle Overbosch Robin B. Peters J. Martijn van Swieten Matthijs Oudkerk Paul E. Sijens 《Magma (New York, N.Y.)》2017,30(3):239-254
Objectives
Early detection of iron loading is affected by the reproducibility of myocardial contour assessment. A novel semi-automatic myocardial segmentation method is presented on contrast-optimized composite images and compared to the results of manual drawing.Materials and methods
Fifty-one short-axis slices at basal, mid-ventricular and apical locations from 17 patients were acquired by bright blood multi-gradient echo MRI. Four observers produced semi-automatic and manual myocardial contours on contrast-optimized composite images. The semi-automatic segmentation method relies on vector field convolution active contours to generate the endocardial contour. After creating radial pixel clusters on the myocardial wall, a combination of pixel-wise coefficient of variance (CoV) assessment and k-means clustering establishes the epicardial contour for each segment.Results
Compared to manual drawing, semi-automatic myocardial segmentation lowers the variability of T2* quantification within and between observers (CoV of 12.05 vs. 13.86% and 14.43 vs. 16.01%) by improving contour reproducibility (P < 0.001). In the presence of iron loading, semi-automatic segmentation also lowers the T2* variability within and between observers (CoV of 13.14 vs. 15.19% and 15.91 vs. 17.28%).Conclusion
Application of semi-automatic myocardial segmentation on contrast-optimized composite images improves the reproducibility of T2* quantification.3.
Jason Langley Daniel E. Huddleston Christine J. Liu Xiaoping Hu 《Magma (New York, N.Y.)》2017,30(2):121-125
Objectives
The purpose of this study was to assess the reproducibility of substantia nigra pars compacta (SNpc) and locus coeruleus (LC) delineation and measurement with neuromelanin-sensitive MRI.Materials and methods
Eleven subjects underwent two neuromelanin-sensitive MRI scans. SNpc and LC volumes were extracted for each scan. Reproducibility of volume and magnetization transfer contrast measurements in SNpc and LC was assessed using intraclass correlation coefficients (ICC) and dice similarity coefficients (DSC).Results
SNpc and LC volume measurements showed excellent reproducibility (SNpc-ICC: 0.94, p < 0.001; LC-ICC: 0.96, p < 0.001). SNpc and LC were accurately delineated between scans (SNpc-DSC: 0.80 ± 0.03; LC-DSC: 0.63 ± 0.07).Conclusion
Neuromelanin-sensitive MRI can consistently delineate SNpc and LC.4.
Daniel Giese Kilian Weiss Bettina Baeßler Navid Madershahian Yeong-Hoon Choi David Maintz Alexander C. Bunck 《Magma (New York, N.Y.)》2018,31(1):165-172
Objectives
The objective of the current work was to evaluate flow and turbulent kinetic energy in different transcatheter aortic valve implants using highly undersampled time-resolved multi-point 3-directional phase-contrast measurements (4D Flow MRI) in an in vitro setup.Materials and methods
A pulsatile flow setup was used with a compliant tubing mimicking a stiff left ventricular outflow tract and ascending aorta. Five different implants were measured using a highly undersampled multi-point 4D Flow MRI sequence. Velocities and turbulent kinetic energy values were analysed and compared.Results
Strong variations of turbulent kinetic energy distributions between the valves were observed. Maximum turbulent kinetic energy values ranged from 100 to over 500 J/m3 while through-plane velocities were similar between all valves.Conclusion
Highly accelerated 4D Flow MRI for the measurement of velocities and turbulent kinetic energy values allowed for the assessment of hemodynamic parameters in five different implant models. The presented setup, measurement protocol and analysis methods provides an efficient approach to compare different valve implants and could aid future novel valve designs.5.
Henry Rusinek Jeremy C. Lim Nicole Wake Jas-mine Seah Elissa Botterill Shawna Farquharson Artem Mikheev Ruth P. Lim 《Magma (New York, N.Y.)》2016,29(2):197-206
Objective
To investigate the precision and accuracy of a new semi-automated method for kidney segmentation from single-breath-hold non-contrast MRI.Materials and methods
The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology. Three independent observers applied the method to images of 40 kidneys ranging in volume from 94.6 to 254.5 cm3. Manually constructed reference masks were used to assess accuracy.Results
The volume errors for the three readers were: 4.4 % ± 3.0 %, 2.9 % ± 2.3 %, and 3.1 % ± 2.7 %. The relative discrepancy across readers was 2.5 % ± 2.1 %. The interactive processing time on average was 1.5 min per kidney.Conclusions
Pending further validation, the semi-automated method could be applied for monitoring of renal status using non-contrast MRI.6.
Michael Jeserich Bela Merkely Pascal Schlosser Simone Kimmel Gabor Pavlik Stephan Achenbach 《Magma (New York, N.Y.)》2017,30(3):309-316
Objective
To evaluate three-dimensional T2-weighted fast spin echo triple inversion recovery sequences (STIR+) for the diagnosis of myocardial edema in patients with suspected early myocarditis after respiratory or gastrointestinal tract viral infection and at follow-up.Materials and methods
We prospectively examined 28 patients with suspected myocarditis and 37 controls matched for gender and age. An ECG-triggered STIR+ was used to cover the entire left ventricle in short-axis images with 10-mm slice thickness and no interslice gap. The global signal intensity ratio (heart muscle in relation to skeletal muscle) was calculated (global STIR+ ratio) to evaluate edema. All patients had repeat examinations at follow-up (mean interval 4.9 months, 1–12 months).Results
The mean global STIR+ ratio was 2.15 ± 0.4 in the initial examination of patients as compared to 1.78 ± 0.3 in controls (p < 0.0001) and 1.89 ± 0.3 in patients at follow-up (p = 0.0001 vs. first visit). Left ventricular ejection fraction did not differ between patients and controls at baseline and at follow-up.Conclusion
We could identify a significantly higher global STIR+ ratio in patients with suspected myocarditis compared to controls, and a dynamic change during follow-up. The global STIR+ ratio may, therefore, be useful for the diagnosis of myocarditis and should be further explored.7.
Amandine Coum Lobna Ouldamer Fanny Noury Laurent Barantin Aymeric Saint-Hilaire Anne Vilde Philippe Bougnoux Giulio Gambarota 《Magma (New York, N.Y.)》2016,29(1):1-4
Objective
To evaluate the feasibility of in vivo measurement of the fatty acid (FA) composition of breast adipose tissue by MRS on a clinical platform.Material and methods
MRS experiments were performed at 3 T, using a STEAM sequence, on 25 patients diagnosed with breast cancer. MR spectra, acquired on healthy breast tissue, were analysed with the LCModel.Results
The measured values of the saturated fatty acid (SFA), mono-unsaturated fatty acid (MUFA) and poly-unsaturated fatty acid (PUFA) fractions were 23.8 ± 7.1 %, 55.4 ± 6.8 % and 20.8 ± 4.4 %, respectively.The values of SFA, MUFA and PUFA observed in the current study are in the same range as those found in two previous studies performed at 7 T.Conclusion
The results of the current study show that it is possible to quantify the fatty acid composition of breast tissue in vivo in a clinical setting (3 T).8.
Tomas Lapinskas Bernhard Schnackenburg Marc Kouwenhoven Rolf Gebker Alexander Berger Remigijus Zaliunas Burkert Pieske Sebastian Kelle 《Magma (New York, N.Y.)》2018,31(1):75-85
Objective
This study aimed to investigate the advantages of recently developed cardiac imaging techniques of fat–water separation and feature tracking to characterize better individuals with chronic myocardial infarction (MI).Materials and methods
Twenty patients who had a previous MI underwent CMR imaging. The study protocol included routine cine and late gadolinium enhancement (LGE) technique. In addition, mDixon LGE imaging was performed in every patient. Left ventricular (LV) circumferential (EccLV) and radial (ErrLV) strain were calculated using dedicated software (CMR42, Circle, Calgary, Canada). The extent of global scar was measured in LGE and fat–water separated images to compare conventional and recent CMR imaging techniques.Results
The infarct size derived from conventional LGE and fat–water separated images was similar. However, detection of lipomatous metaplasia was only possible with mDixon imaging. Subjects with fat deposition demonstrated a significantly smaller percentage of fibrosis than those without fat (10.68 ± 5.07% vs. 13.83 ± 6.30%; p = 0.005). There was no significant difference in EccLV or ErrLV between myocardial segments containing fibrosis only and fibrosis with fat. However, EccLV and ErrLV values were significantly higher in myocardial segments adjacent to fibrosis with fat deposition than in those adjacent to LGE only.Conclusions
Advanced CMR imaging ensures more detailed tissue characterization in patients with chronic MI without a relevant increase in imaging and post-processing time. Fatty metaplasia may influence regional myocardial deformation especially in the myocardial segments adjacent to scar tissue. A simplified and shortened myocardial viability CMR protocol might be useful to better characterize and stratify patients with chronic MI.9.
Thérèse Barbier Sarra Aissani Nicolas Weber Cédric Pasquier Jacques Felblinger 《Magma (New York, N.Y.)》2018,31(5):677-688
Purpose
To evaluate the function of an active implantable medical device (AIMD) during magnetic resonance imaging (MRI) scans. The induced voltages caused by the switching of magnetic field gradients and rectified radio frequency (RF) pulse were measured, along with the AIMD stimulations.Materials and methods
An MRI-compatible voltage probe with a bandwidth of 0–40 kHz was designed. Measurements were carried out both on the bench with an overvoltage protection circuit commonly used for AIMD and with a pacemaker during MRI scans on a 1.5 T (64 MHz) MR scanner.Results
The sensor exhibits a measurement range of?±?15 V with an amplitude resolution of 7 mV and a temporal resolution of 10 µs. Rectification was measured on the bench with the overvoltage protection circuit. Linear proportionality was confirmed between the induced voltage and the magnetic field gradient slew rate. The pacemaker pacing was recorded successfully during MRI scans.Conclusion
The characteristics of this low-frequency voltage probe allow its use with extreme RF transmission power and magnetic field gradient positioning for MR safety test of AIMD during MRI scans.10.
Objective
To retrospectively assess perception of safety of healthy individuals working with human 7 Tesla (T) magnetic resonance imaging (MRI) scanners.Materials and methods
A total of 66 healthy individuals with a mean age of 31 ± 7 years participated in this retrospective multicentre survey study. Nonparametric correlation analysis was conducted to evaluate the relation between self-reported perception of safety and prevalence of sensory effects while working with 7 T MRI scanners for an average 47 months.Results
The results indicated that 98.5 % of the study participants had a neutral or positive feeling about safety aspects at 7 T MRI scanners. 45.5 % reported that they feel very safe and none of the participants stated that they feel moderately or very unsafe while working with 7 T MRI scanners. Perception of safety was not affected by the number of hours per week spent in the vicinity of the 7 T MRI scanner or the duration of experience with 7 T MRI. More than 50 % of individuals experienced vertigo and metallic taste while working with 7 T MRI scanners. However, participants’ perceptions of safety were not affected by the prevalence of MR-related symptoms.Conclusions
The overall data indicated an average perception of a moderately safe work environment. To our knowledge, this study delineates the first attempt to assess the subjective safety perception among 7 T MRI workers and suggests further investigations are indicated.11.
Jerome Chaptinel Davide Piccini Gabriele Bonanno Simone Coppo Pierre Monney Matthias Stuber Juerg Schwitter 《Magma (New York, N.Y.)》2017,30(3):215-225
Objectives
Our objective was to test a data-exclusion strategy for respiratory motion suppression by retrospectively eliminating data acquired at extreme respiratory positions for improved coronary vessel sharpness (VS) of 1-D self-navigated 3-D radial whole-heart coronary angiography acquisitions.Materials and methods
3-D radial self-navigated acquisitions were performed on a 1.5T scanner in volunteers during free-breathing (n = 8), in coached volunteers (n = 13) who were asked to breathe in a controlled manner to mimic cardiovascular patients presenting with Cheyne-Stokes breathing, and in free-breathing patients (n = 20). Data collected during large respiratory excursions were gradually excluded retrospectively from the reconstruction yielding 14 data sets per subject on average. The impact on VS, blood and myocardium signal-to-noise and contrast-to-noise was measured. From these results, two retrospective gating strategies were defined for the k-line elimination procedure and tested in all groups.Results
Maximum right coronary artery VS improvement was +7.4 and +2.7% in coached volunteers and patients (P < 0.0001 for both), respectively, and 1.6% for the free-breathing volunteers (P = 0.13). The first gating strategy was defined as a fixed undersampling factor of 5 compared to a fully sampled 3-D radial acquisition, yielding significant VS improvement in coached volunteers and patients while myocardial signal-to-noise decreased in these. The second strategy was defined as a fixed gating window of 5.7 mm, leading to similar improvements.Conclusion
The presented strategies improve image quality of self-navigated acquisitions by retrospectively excluding data collected during end-inspiration.12.
Oliver Kraff Andrea Lazik-Palm Rahel Heule Jens M. Theysohn Oliver Bieri Harald H. Quick 《Magma (New York, N.Y.)》2016,29(3):503-512
Objectives
We aimed to evaluate the feasibility of triple-echo steady state (TESS) T2 mapping as an alternative to conventional multi-echo-spin-echo (CPMG) T2 mapping for the quantitative assessment of hip joint cartilage at 7 T.Materials and methods
A total of eight healthy volunteers and three patients were included. Reproducibility of both techniques was evaluated in five volunteers in five scans each. T2 relaxation times were measured by manually drawing regions of interest in multiple regions of the hip joint. Data from both methods were compared using Pearson correlation coefficient, intra-class correlation coefficient, and coefficient of repeatability. The overall image quality and presence of artifacts was assessed.Results
Cartilage transplant and surrounding fluid were well depicted by both methods. Compared to CPMG, TESS provided systematically reduced T2 values (43.3 ± 7.3 vs. 19.2 ± 5.5 ms for acetabular cartilage, and 41.4 ± 5.6 vs. 21.7 ± 5.2 ms for femoral cartilage), in line with previously reported values. No correlation between both methods was found. TESS yielded a slightly better reproducibility than CPMG, while CPMG showed pronounced sensitivity to B1 inhomogeneities.Conclusion
TESS seems to be an attractive alternative to CPMG for improvements in quantitative hip joint imaging at 7 T, allowing shortening of the total acquisition time paired with insensitivity to B1, while rendering comparable image quality with good repeatability.13.
Sophie Schumacher Florence Pache Judith Bellmann-Strobl Janina Behrens Petr Dusek Lutz Harms Klemens Ruprecht Petra Nytrova Sanjeev Chawla Thoralf Niendorf Ilya Kister Friedemann Paul Jens Wuerfel Tim Sinnecker 《Magma (New York, N.Y.)》2016,29(3):535-541
Objective
To quantify the periventricular venous density in neuromyelitis optica spectrum disease (NMOSD) in comparison to that in patients with multiple sclerosis (MS) and healthy control subjects.Materials and methods
Sixteen patients with NMOSD, 16 patients with MS and 16 healthy control subjects underwent 7.0-Tesla (7T) MRI. The imaging protocol included T2*-weighted (T2*w) fast low angle-shot (FLASH) and fluid-attenuated inversion recovery (FLAIR) sequences. The periventricular venous area (PVA) was manually determined by a blinded investigator in order to estimate the periventricular venous density in a region of interest-based approach.Results
No significant differences in periventricular venous density indicated by PVA were detectable in NMOSD versus healthy controls (p = 0.226). In contrast, PVA was significantly reduced in MS patients compared to healthy controls (p = 0.013).Conclusion
Unlike patients with MS, those suffering from NMOSD did not show reduced venous visibility. This finding may underscore primary and secondary pathophysiological differences between these two distinct diseases of the central nervous system.14.
Object
Recent advances have allowed oscillating gradient (OG) diffusion MRI to infer the sizes of micron-scale axon diameters. Here the effects on the precision of the inferred diameters are studied when reducing the number of images collected to reduce imaging time for clinical feasibility.Materials and methods
Monte Carlo simulations of cosine OG sequences (50–1000 Hz) using a two-compartment model on a parallel cylinder (diameters 1–5 μm) geometry were conducted. Temporal diffusion spectroscopy was used to infer axon diameters. Three different gradient sets were simulated with different combinations of gradient strengths.Results
Five frequencies were adequate for d = 3–5 μm with single-sized cylinders and for effective mean axon diameters greater than 2 μm for cylinders with a distributions of diameters. There was some improvement in precision for d = 1–2 μm with 10 frequencies. It is better to repeat measurements at higher gradient strengths than to use a range of gradient strengths. The improvement tended to be greatest when using fewer frequencies and was especially noticeable at very high gradient strengths.Conclusion
Images can be collected with fewer gradient strengths and frequencies without sacrificing the precision of the measurements. This could be useful in reducing imaging time so that OG techniques can be used in clinical settings.15.
Automated assessment of thigh composition using machine learning for Dixon magnetic resonance images
Yu Xin Yang Mei Sian Chong Laura Tay Suzanne Yew Audrey Yeo Cher Heng Tan 《Magma (New York, N.Y.)》2016,29(5):723-731
Objectives
To develop and validate a machine learning based automated segmentation method that jointly analyzes the four contrasts provided by Dixon MRI technique for improved thigh composition segmentation accuracy.Materials and methods
The automatic detection of body composition is formulized as a three-class classification issue. Each image voxel in the training dataset is assigned with a correct label. A voxel classifier is trained and subsequently used to predict unseen data. Morphological operations are finally applied to generate volumetric segmented images for different structures. We applied this algorithm on datasets of (1) four contrast images, (2) water and fat images, and (3) unsuppressed images acquired from 190 subjects.Results
The proposed method using four contrasts achieved most accurate and robust segmentation compared to the use of combined fat and water images and the use of unsuppressed image, average Dice coefficients of 0.94 ± 0.03, 0.96 ± 0.03, 0.80 ± 0.03, and 0.97 ± 0.01 has been achieved to bone region, subcutaneous adipose tissue (SAT), inter-muscular adipose tissue (IMAT), and muscle respectively.Conclusion
Our proposed method based on machine learning produces accurate tissue quantification and showed an effective use of large information provided by the four contrast images from Dixon MRI.16.
Andreas Reichert Michael Bock Simon Reiss Christiaan G. Overduin Jurgen J. Fütterer Axel Joachim Krafft 《Magma (New York, N.Y.)》2018,31(6):781-788
Objective
To accelerate a passive tracking sequence based on phase-only cross correlation (POCC) using simultaneous slice excitation.Methods
For magnetic resonance (MR)-guided biopsy procedures, passive markers have been proposed that can be automatically localized online using a POCC-based tracking sequence. To accelerate the sequence, a phase-offset multiplanar (POMP) excitation technique was implemented to acquire tracking images. In a phantom experiment, the POMP–POCC sequence was tested and compared with the sequential non-accelerated version in terms of duration and accuracy. Further, technical feasibility of the POMP–POCC sequence was tested in a patient undergoing a prostate biopsy.Results
The temporal resolution of the POMP–POCC tracking sequence is accelerated by 33% compared with the sequential approach. In phantom experiments, the POMP–POCC and sequential sequences yielded the same targeting accuracy of 1.6?±?0.7 mm. Technical proof of concept of the new sequence could be demonstrated in a successful in vivo prostate biopsy.Conclusion
POMP–POCC tracking can substantially reduce the duration of localization of passive markers in MR-guided needle interventions without compromising targeting accuracy.17.
Tora Dunås Anders Wåhlin Khalid Ambarki Laleh Zarrinkoob Richard Birgander Jan Malm Anders Eklund 《Magma (New York, N.Y.)》2016,29(1):39-47
Objectives
In order to introduce 4D flow magnetic resonance imaging (MRI) as a standard clinical instrument for studying the cerebrovascular system, new and faster postprocessing tools are necessary. The objective of this study was to construct and evaluate a method for automatic identification of individual cerebral arteries in a 4D flow MRI angiogram.Materials and methods
Forty-six elderly individuals were investigated with 4D flow MRI. Fourteen main cerebral arteries were manually labeled and used to create a probabilistic atlas. An automatic atlas-based artery identification method (AAIM) was developed based on vascular-branch extraction and the atlas was used for identification. The method was evaluated by comparing automatic with manual identification in 4D flow MRI angiograms from 67 additional elderly individuals.Results
Overall accuracy was 93 %, and internal carotid artery and middle cerebral artery labeling was 100 % accurate. Smaller and more distal arteries had lower accuracy; for posterior communicating arteries and vertebral arteries, accuracy was 70 and 89 %, respectively.Conclusion
The AAIM enabled fast and fully automatic labeling of the main cerebral arteries. AAIM functionality provides the basis for creating an automatic and powerful method to analyze arterial cerebral blood flow in clinical routine.18.
Niels D. Naimon Jerzy Walczyk James S. Babb Oleksandr Khegai Xuejiao Che Leeor Alon Ravinder R. Regatte Ryan Brown Prodromos Parasoglou 《Magma (New York, N.Y.)》2017,30(3):281-289
Objective
To develop a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems to reliably quantify metabolic parameters in human lower leg muscle using phosphorus magnetic resonance spectroscopy.Materials and methods
We constructed an MR compatible ergometer using commercially available materials and elastic bands that provide resistance to movement. We recruited ten healthy subjects (eight men and two women, mean age ± standard deviation: 32.8 ± 6.0 years, BMI: 24.1 ± 3.9 kg/m2). All subjects were scanned on a 7 T whole-body magnet. Each subject was scanned on two visits and performed a 90 s plantar flexion exercise at 40% maximum voluntary contraction during each scan. During the first visit, each subject performed the exercise twice in order for us to estimate the intra-exam repeatability, and once during the second visit in order to estimate the inter-exam repeatability of the time constant of phosphocreatine recovery kinetics. We assessed the intra and inter-exam reliability in terms of the within-subject coefficient of variation (CV).Results
We acquired reliable measurements of PCr recovery kinetics with an intra- and inter-exam CV of 7.9% and 5.7%, respectively.Conclusion
We constructed a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems, which allowed us to quantify reliably PCr recovery kinetics in lower leg muscle using 31P-MRS.19.
Object
To develop an improved short tau inversion recovery (iSTIR) technique with simultaneous suppression of fat, blood vessels and fluid to increase tumor conspicuity in the abdomen for cancer screening.Materials and methods
An adiabatic spectrally selective inversion pulse was used for fat suppression to overcome the reduced signal to noise ratio associated with chemically non-selective inversion pulse of STIR. A motion-sensitizing driven equilibrium was used for blood vessel suppression and a dual-echo single-shot fast spin echo acquisition was used for fluid suppression. The technique was optimized on four normal subjects and later tested on five patients referred for metastatic tumor evaluation.Results
A velocity encoding of 2 cm/s achieved effective blood suppression even in small vessels. Subtraction of two images (one with 60 ms and the other with 280 ms echo time) acquired in the same echo train achieved excellent fluid suppression (>70 % reduction). Simultaneous suppression of fat, blood vessels and fluid improved the tumor conspicuity compared to corresponding fat-suppressed (STIR) image.Conclusion
This technique generated two complementary images from a single scan: one that is equivalent to a STIR image and the other that qualitatively resembles a diffusion-weighted image and may have potential for magnetic resonance imaging cancer screening.20.
Géraldine Pastor María Jiménez-González Sandra Plaza-García Marta Beraza Torsten Reese 《Magma (New York, N.Y.)》2017,30(3):299-307