1.

Objectives

Reproducibility of myocardial contour determination in cardiac magnetic resonance imaging is important, especially when determining T2* values per myocardial segment as a prognostic factor of heart failure or thalassemia. A method creating a composite image with contrasts optimized for drawing myocardial contours is introduced and compared with the standard method on a single image.

Materials and methods

A total of 36 short-axis slices from bright-blood multigradient echo (MGE) T2* scans of 21 patients were acquired at eight echo times. Four observers drew free-hand myocardial contours on one manually selected T2* image (method 1) and on one image composed by blending three images acquired at TEs providing optimum contrast-to-noise ratio between the myocardium and its surrounding regions (method 2).

Results

Myocardial contouring by method 2 met higher interobserver reproducibility than method 1 (P < 0.001) with smaller Coefficient of variance (CoV) of T2* values in the presence of myocardial iron accumulation (9.79 vs. 15.91 %) and in both global myocardial and mid-ventricular septum regions (12.29 vs. 16.88 and 5.76 vs. 8.16 %, respectively).

Conclusion

The use of contrast-optimized composite images in MGE data analysis improves reproducibility of myocardial contour determination, leading to increased consistency in the calculated T2* values enhancing the diagnostic impact of this measure of iron overload.
  相似文献   

2.

Objectives

Early detection of iron loading is affected by the reproducibility of myocardial contour assessment. A novel semi-automatic myocardial segmentation method is presented on contrast-optimized composite images and compared to the results of manual drawing.

Materials and methods

Fifty-one short-axis slices at basal, mid-ventricular and apical locations from 17 patients were acquired by bright blood multi-gradient echo MRI. Four observers produced semi-automatic and manual myocardial contours on contrast-optimized composite images. The semi-automatic segmentation method relies on vector field convolution active contours to generate the endocardial contour. After creating radial pixel clusters on the myocardial wall, a combination of pixel-wise coefficient of variance (CoV) assessment and k-means clustering establishes the epicardial contour for each segment.

Results

Compared to manual drawing, semi-automatic myocardial segmentation lowers the variability of T2* quantification within and between observers (CoV of 12.05 vs. 13.86% and 14.43 vs. 16.01%) by improving contour reproducibility (P < 0.001). In the presence of iron loading, semi-automatic segmentation also lowers the T2* variability within and between observers (CoV of 13.14 vs. 15.19% and 15.91 vs. 17.28%).

Conclusion

Application of semi-automatic myocardial segmentation on contrast-optimized composite images improves the reproducibility of T2* quantification.
  相似文献   

3.

Objectives

The purpose of this study was to assess the reproducibility of substantia nigra pars compacta (SNpc) and locus coeruleus (LC) delineation and measurement with neuromelanin-sensitive MRI.

Materials and methods

Eleven subjects underwent two neuromelanin-sensitive MRI scans. SNpc and LC volumes were extracted for each scan. Reproducibility of volume and magnetization transfer contrast measurements in SNpc and LC was assessed using intraclass correlation coefficients (ICC) and dice similarity coefficients (DSC).

Results

SNpc and LC volume measurements showed excellent reproducibility (SNpc-ICC: 0.94, p < 0.001; LC-ICC: 0.96, p < 0.001). SNpc and LC were accurately delineated between scans (SNpc-DSC: 0.80 ± 0.03; LC-DSC: 0.63 ± 0.07).

Conclusion

Neuromelanin-sensitive MRI can consistently delineate SNpc and LC.
  相似文献   

4.

Objectives

The objective of the current work was to evaluate flow and turbulent kinetic energy in different transcatheter aortic valve implants using highly undersampled time-resolved multi-point 3-directional phase-contrast measurements (4D Flow MRI) in an in vitro setup.

Materials and methods

A pulsatile flow setup was used with a compliant tubing mimicking a stiff left ventricular outflow tract and ascending aorta. Five different implants were measured using a highly undersampled multi-point 4D Flow MRI sequence. Velocities and turbulent kinetic energy values were analysed and compared.

Results

Strong variations of turbulent kinetic energy distributions between the valves were observed. Maximum turbulent kinetic energy values ranged from 100 to over 500 J/m3 while through-plane velocities were similar between all valves.

Conclusion

Highly accelerated 4D Flow MRI for the measurement of velocities and turbulent kinetic energy values allowed for the assessment of hemodynamic parameters in five different implant models. The presented setup, measurement protocol and analysis methods provides an efficient approach to compare different valve implants and could aid future novel valve designs.
  相似文献   

5.

Objective

To investigate the precision and accuracy of a new semi-automated method for kidney segmentation from single-breath-hold non-contrast MRI.

Materials and methods

The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology. Three independent observers applied the method to images of 40 kidneys ranging in volume from 94.6 to 254.5 cm3. Manually constructed reference masks were used to assess accuracy.

Results

The volume errors for the three readers were: 4.4 % ± 3.0 %, 2.9 % ± 2.3 %, and 3.1 % ± 2.7 %. The relative discrepancy across readers was 2.5 % ± 2.1 %. The interactive processing time on average was 1.5 min per kidney.

Conclusions

Pending further validation, the semi-automated method could be applied for monitoring of renal status using non-contrast MRI.
  相似文献   

6.

Objective

To evaluate three-dimensional T2-weighted fast spin echo triple inversion recovery sequences (STIR+) for the diagnosis of myocardial edema in patients with suspected early myocarditis after respiratory or gastrointestinal tract viral infection and at follow-up.

Materials and methods

We prospectively examined 28 patients with suspected myocarditis and 37 controls matched for gender and age. An ECG-triggered STIR+ was used to cover the entire left ventricle in short-axis images with 10-mm slice thickness and no interslice gap. The global signal intensity ratio (heart muscle in relation to skeletal muscle) was calculated (global STIR+ ratio) to evaluate edema. All patients had repeat examinations at follow-up (mean interval 4.9 months, 1–12 months).

Results

The mean global STIR+ ratio was 2.15 ± 0.4 in the initial examination of patients as compared to 1.78 ± 0.3 in controls (p < 0.0001) and 1.89 ± 0.3 in patients at follow-up (p = 0.0001 vs. first visit). Left ventricular ejection fraction did not differ between patients and controls at baseline and at follow-up.

Conclusion

We could identify a significantly higher global STIR+ ratio in patients with suspected myocarditis compared to controls, and a dynamic change during follow-up. The global STIR+ ratio may, therefore, be useful for the diagnosis of myocarditis and should be further explored.
  相似文献   

7.

Objective

To evaluate the feasibility of in vivo measurement of the fatty acid (FA) composition of breast adipose tissue by MRS on a clinical platform.

Material and methods

MRS experiments were performed at 3 T, using a STEAM sequence, on 25 patients diagnosed with breast cancer. MR spectra, acquired on healthy breast tissue, were analysed with the LCModel.

Results

The measured values of the saturated fatty acid (SFA), mono-unsaturated fatty acid (MUFA) and poly-unsaturated fatty acid (PUFA) fractions were 23.8 ± 7.1 %, 55.4 ± 6.8 % and 20.8 ± 4.4 %, respectively.The values of SFA, MUFA and PUFA observed in the current study are in the same range as those found in two previous studies performed at 7 T.

Conclusion

The results of the current study show that it is possible to quantify the fatty acid composition of breast tissue in vivo in a clinical setting (3 T).
  相似文献   

8.

Objective

This study aimed to investigate the advantages of recently developed cardiac imaging techniques of fat–water separation and feature tracking to characterize better individuals with chronic myocardial infarction (MI).

Materials and methods

Twenty patients who had a previous MI underwent CMR imaging. The study protocol included routine cine and late gadolinium enhancement (LGE) technique. In addition, mDixon LGE imaging was performed in every patient. Left ventricular (LV) circumferential (EccLV) and radial (ErrLV) strain were calculated using dedicated software (CMR42, Circle, Calgary, Canada). The extent of global scar was measured in LGE and fat–water separated images to compare conventional and recent CMR imaging techniques.

Results

The infarct size derived from conventional LGE and fat–water separated images was similar. However, detection of lipomatous metaplasia was only possible with mDixon imaging. Subjects with fat deposition demonstrated a significantly smaller percentage of fibrosis than those without fat (10.68 ± 5.07% vs. 13.83 ± 6.30%; p = 0.005). There was no significant difference in EccLV or ErrLV between myocardial segments containing fibrosis only and fibrosis with fat. However, EccLV and ErrLV values were significantly higher in myocardial segments adjacent to fibrosis with fat deposition than in those adjacent to LGE only.

Conclusions

Advanced CMR imaging ensures more detailed tissue characterization in patients with chronic MI without a relevant increase in imaging and post-processing time. Fatty metaplasia may influence regional myocardial deformation especially in the myocardial segments adjacent to scar tissue. A simplified and shortened myocardial viability CMR protocol might be useful to better characterize and stratify patients with chronic MI.
  相似文献   

9.

Purpose

To evaluate the function of an active implantable medical device (AIMD) during magnetic resonance imaging (MRI) scans. The induced voltages caused by the switching of magnetic field gradients and rectified radio frequency (RF) pulse were measured, along with the AIMD stimulations.

Materials and methods

An MRI-compatible voltage probe with a bandwidth of 0–40 kHz was designed. Measurements were carried out both on the bench with an overvoltage protection circuit commonly used for AIMD and with a pacemaker during MRI scans on a 1.5 T (64 MHz) MR scanner.

Results

The sensor exhibits a measurement range of?±?15 V with an amplitude resolution of 7 mV and a temporal resolution of 10 µs. Rectification was measured on the bench with the overvoltage protection circuit. Linear proportionality was confirmed between the induced voltage and the magnetic field gradient slew rate. The pacemaker pacing was recorded successfully during MRI scans.

Conclusion

The characteristics of this low-frequency voltage probe allow its use with extreme RF transmission power and magnetic field gradient positioning for MR safety test of AIMD during MRI scans.
  相似文献   

10.

Objective

To retrospectively assess perception of safety of healthy individuals working with human 7 Tesla (T) magnetic resonance imaging (MRI) scanners.

Materials and methods

A total of 66 healthy individuals with a mean age of 31 ± 7 years participated in this retrospective multicentre survey study. Nonparametric correlation analysis was conducted to evaluate the relation between self-reported perception of safety and prevalence of sensory effects while working with 7 T MRI scanners for an average 47 months.

Results

The results indicated that 98.5 % of the study participants had a neutral or positive feeling about safety aspects at 7 T MRI scanners. 45.5 % reported that they feel very safe and none of the participants stated that they feel moderately or very unsafe while working with 7 T MRI scanners. Perception of safety was not affected by the number of hours per week spent in the vicinity of the 7 T MRI scanner or the duration of experience with 7 T MRI. More than 50 % of individuals experienced vertigo and metallic taste while working with 7 T MRI scanners. However, participants’ perceptions of safety were not affected by the prevalence of MR-related symptoms.

Conclusions

The overall data indicated an average perception of a moderately safe work environment. To our knowledge, this study delineates the first attempt to assess the subjective safety perception among 7 T MRI workers and suggests further investigations are indicated.
  相似文献   

11.

Objectives

Our objective was to test a data-exclusion strategy for respiratory motion suppression by retrospectively eliminating data acquired at extreme respiratory positions for improved coronary vessel sharpness (VS) of 1-D self-navigated 3-D radial whole-heart coronary angiography acquisitions.

Materials and methods

3-D radial self-navigated acquisitions were performed on a 1.5T scanner in volunteers during free-breathing (n = 8), in coached volunteers (n = 13) who were asked to breathe in a controlled manner to mimic cardiovascular patients presenting with Cheyne-Stokes breathing, and in free-breathing patients (n = 20). Data collected during large respiratory excursions were gradually excluded retrospectively from the reconstruction yielding 14 data sets per subject on average. The impact on VS, blood and myocardium signal-to-noise and contrast-to-noise was measured. From these results, two retrospective gating strategies were defined for the k-line elimination procedure and tested in all groups.

Results

Maximum right coronary artery VS improvement was +7.4 and +2.7% in coached volunteers and patients (P < 0.0001 for both), respectively, and 1.6% for the free-breathing volunteers (P = 0.13). The first gating strategy was defined as a fixed undersampling factor of 5 compared to a fully sampled 3-D radial acquisition, yielding significant VS improvement in coached volunteers and patients while myocardial signal-to-noise decreased in these. The second strategy was defined as a fixed gating window of 5.7 mm, leading to similar improvements.

Conclusion

The presented strategies improve image quality of self-navigated acquisitions by retrospectively excluding data collected during end-inspiration.
  相似文献   

12.

Objectives

We aimed to evaluate the feasibility of triple-echo steady state (TESS) T2 mapping as an alternative to conventional multi-echo-spin-echo (CPMG) T2 mapping for the quantitative assessment of hip joint cartilage at 7 T.

Materials and methods

A total of eight healthy volunteers and three patients were included. Reproducibility of both techniques was evaluated in five volunteers in five scans each. T2 relaxation times were measured by manually drawing regions of interest in multiple regions of the hip joint. Data from both methods were compared using Pearson correlation coefficient, intra-class correlation coefficient, and coefficient of repeatability. The overall image quality and presence of artifacts was assessed.

Results

Cartilage transplant and surrounding fluid were well depicted by both methods. Compared to CPMG, TESS provided systematically reduced T2 values (43.3 ± 7.3 vs. 19.2 ± 5.5 ms for acetabular cartilage, and 41.4 ± 5.6 vs. 21.7 ± 5.2 ms for femoral cartilage), in line with previously reported values. No correlation between both methods was found. TESS yielded a slightly better reproducibility than CPMG, while CPMG showed pronounced sensitivity to B1 inhomogeneities.

Conclusion

TESS seems to be an attractive alternative to CPMG for improvements in quantitative hip joint imaging at 7 T, allowing shortening of the total acquisition time paired with insensitivity to B1, while rendering comparable image quality with good repeatability.
  相似文献   

13.

Objective

To quantify the periventricular venous density in neuromyelitis optica spectrum disease (NMOSD) in comparison to that in patients with multiple sclerosis (MS) and healthy control subjects.

Materials and methods

Sixteen patients with NMOSD, 16 patients with MS and 16 healthy control subjects underwent 7.0-Tesla (7T) MRI. The imaging protocol included T2*-weighted (T2*w) fast low angle-shot (FLASH) and fluid-attenuated inversion recovery (FLAIR) sequences. The periventricular venous area (PVA) was manually determined by a blinded investigator in order to estimate the periventricular venous density in a region of interest-based approach.

Results

No significant differences in periventricular venous density indicated by PVA were detectable in NMOSD versus healthy controls (p = 0.226). In contrast, PVA was significantly reduced in MS patients compared to healthy controls (p = 0.013).

Conclusion

Unlike patients with MS, those suffering from NMOSD did not show reduced venous visibility. This finding may underscore primary and secondary pathophysiological differences between these two distinct diseases of the central nervous system.
  相似文献   

14.

Object

Recent advances have allowed oscillating gradient (OG) diffusion MRI to infer the sizes of micron-scale axon diameters. Here the effects on the precision of the inferred diameters are studied when reducing the number of images collected to reduce imaging time for clinical feasibility.

Materials and methods

Monte Carlo simulations of cosine OG sequences (50–1000 Hz) using a two-compartment model on a parallel cylinder (diameters 1–5 μm) geometry were conducted. Temporal diffusion spectroscopy was used to infer axon diameters. Three different gradient sets were simulated with different combinations of gradient strengths.

Results

Five frequencies were adequate for d = 3–5 μm with single-sized cylinders and for effective mean axon diameters greater than 2 μm for cylinders with a distributions of diameters. There was some improvement in precision for d = 1–2 μm with 10 frequencies. It is better to repeat measurements at higher gradient strengths than to use a range of gradient strengths. The improvement tended to be greatest when using fewer frequencies and was especially noticeable at very high gradient strengths.

Conclusion

Images can be collected with fewer gradient strengths and frequencies without sacrificing the precision of the measurements. This could be useful in reducing imaging time so that OG techniques can be used in clinical settings.
  相似文献   

15.

Objectives

To develop and validate a machine learning based automated segmentation method that jointly analyzes the four contrasts provided by Dixon MRI technique for improved thigh composition segmentation accuracy.

Materials and methods

The automatic detection of body composition is formulized as a three-class classification issue. Each image voxel in the training dataset is assigned with a correct label. A voxel classifier is trained and subsequently used to predict unseen data. Morphological operations are finally applied to generate volumetric segmented images for different structures. We applied this algorithm on datasets of (1) four contrast images, (2) water and fat images, and (3) unsuppressed images acquired from 190 subjects.

Results

The proposed method using four contrasts achieved most accurate and robust segmentation compared to the use of combined fat and water images and the use of unsuppressed image, average Dice coefficients of 0.94 ± 0.03, 0.96 ± 0.03, 0.80 ± 0.03, and 0.97 ± 0.01 has been achieved to bone region, subcutaneous adipose tissue (SAT), inter-muscular adipose tissue (IMAT), and muscle respectively.

Conclusion

Our proposed method based on machine learning produces accurate tissue quantification and showed an effective use of large information provided by the four contrast images from Dixon MRI.
  相似文献   

16.

Objective

To accelerate a passive tracking sequence based on phase-only cross correlation (POCC) using simultaneous slice excitation.

Methods

For magnetic resonance (MR)-guided biopsy procedures, passive markers have been proposed that can be automatically localized online using a POCC-based tracking sequence. To accelerate the sequence, a phase-offset multiplanar (POMP) excitation technique was implemented to acquire tracking images. In a phantom experiment, the POMP–POCC sequence was tested and compared with the sequential non-accelerated version in terms of duration and accuracy. Further, technical feasibility of the POMP–POCC sequence was tested in a patient undergoing a prostate biopsy.

Results

The temporal resolution of the POMP–POCC tracking sequence is accelerated by 33% compared with the sequential approach. In phantom experiments, the POMP–POCC and sequential sequences yielded the same targeting accuracy of 1.6?±?0.7 mm. Technical proof of concept of the new sequence could be demonstrated in a successful in vivo prostate biopsy.

Conclusion

POMP–POCC tracking can substantially reduce the duration of localization of passive markers in MR-guided needle interventions without compromising targeting accuracy.
  相似文献   

17.

Objectives

In order to introduce 4D flow magnetic resonance imaging (MRI) as a standard clinical instrument for studying the cerebrovascular system, new and faster postprocessing tools are necessary. The objective of this study was to construct and evaluate a method for automatic identification of individual cerebral arteries in a 4D flow MRI angiogram.

Materials and methods

Forty-six elderly individuals were investigated with 4D flow MRI. Fourteen main cerebral arteries were manually labeled and used to create a probabilistic atlas. An automatic atlas-based artery identification method (AAIM) was developed based on vascular-branch extraction and the atlas was used for identification. The method was evaluated by comparing automatic with manual identification in 4D flow MRI angiograms from 67 additional elderly individuals.

Results

Overall accuracy was 93 %, and internal carotid artery and middle cerebral artery labeling was 100 % accurate. Smaller and more distal arteries had lower accuracy; for posterior communicating arteries and vertebral arteries, accuracy was 70 and 89 %, respectively.

Conclusion

The AAIM enabled fast and fully automatic labeling of the main cerebral arteries. AAIM functionality provides the basis for creating an automatic and powerful method to analyze arterial cerebral blood flow in clinical routine.
  相似文献   

18.

Objective

To develop a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems to reliably quantify metabolic parameters in human lower leg muscle using phosphorus magnetic resonance spectroscopy.

Materials and methods

We constructed an MR compatible ergometer using commercially available materials and elastic bands that provide resistance to movement. We recruited ten healthy subjects (eight men and two women, mean age ± standard deviation: 32.8 ± 6.0 years, BMI: 24.1 ± 3.9 kg/m2). All subjects were scanned on a 7 T whole-body magnet. Each subject was scanned on two visits and performed a 90 s plantar flexion exercise at 40% maximum voluntary contraction during each scan. During the first visit, each subject performed the exercise twice in order for us to estimate the intra-exam repeatability, and once during the second visit in order to estimate the inter-exam repeatability of the time constant of phosphocreatine recovery kinetics. We assessed the intra and inter-exam reliability in terms of the within-subject coefficient of variation (CV).

Results

We acquired reliable measurements of PCr recovery kinetics with an intra- and inter-exam CV of 7.9% and 5.7%, respectively.

Conclusion

We constructed a low-cost pedal ergometer compatible with ultrahigh (7 T) field MR systems, which allowed us to quantify reliably PCr recovery kinetics in lower leg muscle using 31P-MRS.
  相似文献   

19.

Object

To develop an improved short tau inversion recovery (iSTIR) technique with simultaneous suppression of fat, blood vessels and fluid to increase tumor conspicuity in the abdomen for cancer screening.

Materials and methods

An adiabatic spectrally selective inversion pulse was used for fat suppression to overcome the reduced signal to noise ratio associated with chemically non-selective inversion pulse of STIR. A motion-sensitizing driven equilibrium was used for blood vessel suppression and a dual-echo single-shot fast spin echo acquisition was used for fluid suppression. The technique was optimized on four normal subjects and later tested on five patients referred for metastatic tumor evaluation.

Results

A velocity encoding of 2 cm/s achieved effective blood suppression even in small vessels. Subtraction of two images (one with 60 ms and the other with 280 ms echo time) acquired in the same echo train achieved excellent fluid suppression (>70 % reduction). Simultaneous suppression of fat, blood vessels and fluid improved the tumor conspicuity compared to corresponding fat-suppressed (STIR) image.

Conclusion

This technique generated two complementary images from a single scan: one that is equivalent to a STIR image and the other that qualitatively resembles a diffusion-weighted image and may have potential for magnetic resonance imaging cancer screening.
  相似文献   

20.

Objective

A newly adapted zoomed ultrafast low-angle RARE (U-FLARE) sequence is described for abdominal imaging applications at 11.7 Tesla and compared with the standard echo-plannar imaging (EPI) and snapshot fast low angle shot (FLASH) methods.

Materials and methods

Ultrafast EPI and snapshot-FLASH protocols were evaluated to determine relaxation times in phantoms and in the mouse kidney in vivo. Owing to their apparent shortcomings, imaging artefacts, signal-to-noise ratio (SNR), and variability in the determination of relaxation times, these methods are compared with the newly implemented zoomed U-FLARE sequence.

Results

Snapshot-FLASH has a lower SNR when compared with the zoomed U-FLARE sequence and EPI. The variability in the measurement of relaxation times is higher in the Look–Locker sequences than in inversion recovery experiments. Respectively, the average T1 and T2 values at 11.7 Tesla are as follows: kidney cortex, 1810 and 29 ms; kidney medulla, 2100 and 25 ms; subcutaneous tumour, 2365 and 28 ms.

Conclusion

This study demonstrates that the zoomed U-FLARE sequence yields single-shot single-slice images with good anatomical resolution and high SNR at 11.7 Tesla. Thus, it offers a viable alternative to standard protocols for mapping very fast parameters, such as T1 and T2, or dynamic processes in vivo at high field.