首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The interest in SF6 gas mixtures has been re-ignited in recent years by the issue of the greenhouse effect of the SF6 gas, and most research work is now focused on a SF6/N2 gas mixture, which is suitable for application in electrical apparatus with slightly non-uniform fields. This paper presents a comparison of SF6/N2 and SF6/CO2 gas mixtures with a viewpoint of their possible applications to gas-insulated transformers, where both highly non-uniform field problems and partial discharges in gas/film insulation are inevitable. It is shown that in this case the dielectric strength of SF6/CO2 is superior to that of SF6/N 2 with a minor disadvantage related to the gas decomposition in SF6/CO2. However, this may not be a problem for the SF6/CO2 gas mixture to be used in gas-insulated transformers, where internal breakdown is not allowed  相似文献   

2.
The controversy surrounding low-temperature SF6 breakdown is addressed in detail. Earlier relevant studies are reviewed, some of the existing data is analyzed in a new light, and further theoretical considerations are presented. These discussions served to outline an experimental approach aimed at confirming or invalidating breakdown invariance at subnormal temperatures. Low-temperature dc breakdown of an SF6 gas-insulated system was investigated experimentally for temperatures ranging from -50 to 24°C, using associated pressure values that had been selected carefully to avoid phase transition of the gas-insulating medium. The context allowed experimentation under both uniform and nonuniform field conditions; the nonuniformity was due to the active role of the cathode-gas interface at high fields. The experiment was conducted for molecular densities ranging from 2.596 to 16.43×1019 cm-3 (equivalent to pressures of 105 and 624 kPa, respectively, at 24°C) and for gap lengths starting at 0.5 mm and extending to 7 mm. Data sets show consistency, low statistical scattering, and high reproducibility. Data analysis led to several major conclusions. At constant density, the breakdown of the SF6-insulated system is temperature dependent, which is responsible for a decrease in the electric strength, by ~10%. This decrease occurs for uniform field conditions, the effect being small if not negligible for nonuniform field conditions, and is noted to appear at a threshold temperature (-25 to -30°C), take a constant value, and be fairly independent of density  相似文献   

3.
The investigation of gas recovery from N2/SF6 gas mixtures using a polymer membrane has been reported. It has been shown that the purity of recovered gas, the recovery loss, and the gas handling speed depend on various parameters such as original gas mixing ratio, gas feeding pressure, gas flow rate, and temperature of the membrane. A gas recovering system with two membrane separators connected in cascade has proved to be very efficient in attaining high purity in a recovered gas, with negligibly small recovery loss and high handling speed for practical use. Furthermore, this system could be applied for CO2/SF6, He/SF 6 and even for ternary mixtures such as N2/CO2/SF6 without any modification in the system, where we expect much better performance in comparison with N 2/SF6  相似文献   

4.
Cylindrical post spacers were used to investigate the fundamental effect of ribs on particle-initiated breakdown characteristics. Improved breakdown characteristics, obtained by attaching the ribs, changed with the distance between them; the shorter the distance, the higher the breakdown voltage. When the distance was less than 20-30% of the spacer length, the breakdown voltage increased by 20-60%. The rib effectiveness for SF6 gas insulated switchgear spacers was demonstrated  相似文献   

5.
We observed time-resolved partial discharge (PD) characteristics under ac and dc conditions in order to demonstrate the effects of space charge behavior and the corona stabilization effect in SF6 gas. From the experimental results, we found that the charge magnitude of the first PD in the positive half cycle of applied ac voltage depended only on the instantaneous voltage. Under dc conditions we found that the magnitude of the PD charge related closely to the time interval between PD pulses. Space charge behavior and the PD generation mechanism are interpreted diagrammatically, and we describe how positive ions reduce the magnitude of PD charge and activate the corona stabilization effect and that the negative ions shorten the time interval between PD pulses  相似文献   

6.
A perfluorocarbon (PFC) immersed 275 kV power transformer with compressed SF6 gas insulation has been under development. This paper clarifies the AC partial discharge inception voltage and time characteristics of PFC immersed insulation and also clarifies that a prototype 275 kV 100 MVA three-phase transformer could be operated without any trouble during long-term overvoltage tests. This prototype proved that it had AC partial discharge inception strength of higher than 1.5 times the AC test voltage and lightning impulse breakdown strength of 1.5 times the test voltage. A 275 kV, 250 MVA three-phase power transformer was developed and operated at the outdoor substation of the Chubu Electric Power Co., Japan. This transformer has been successfully operated to date and a detailed internal inspection of the transformer was carried out after one year and 9 months of successful practical operation. No significant abnormal condition was recognized  相似文献   

7.
李波 《电气开关》2013,50(1):99-100
通过对SF6断路器采用SF6气体作为灭孤介质的优缺点进行了分析,论述了SF6气体优良的灭孤性能和其分解副产物的腐蚀性能及解决措施,并对SF6断路器的检修方法进行了阐述.  相似文献   

8.
The widespread use of SF6 by the electric power and other industries has led to increased concentrations of SF6 in the atmosphere. This causes concern as to possible effects on global warming, because SF6 is a potent greenhouse gas. This paper first touches on this issue and then documents the behavior of high pressure gases such as N2 and SF6/N2 mixtures that can be realistically considered as acceptable intermediate or long-term replacements for pure SF6 in some HV applications. The possible use of dilute SF6/N2 mixtures as an alternative to pure SF6 for some of industry's insulation needs (albeit at higher pressure) is documented, and existing knowledge on these mixtures and on the individual components (N2 and SF6), both basic and applied, is compiled. A guide to existing literature is provided  相似文献   

9.
Because electric arcs, sparks or corona can decompose SF6 insulators into byproducts having chemical properties different from SF6, environmental concerns arise regarding inadvertent human exposures to electrically decomposed SF6. Biological assays using mammalian cell culture systems have revealed that SF6 , spark-decomposed under specific experimental conditions, can produce cell death. Chemical analysis of spark-decomposed SF6 has identified the major decomposition pathways and byproducts. Biological testing of individual byproduct mixtures has indicated that these major decomposition products may not account for the majority of the cell-killing effects seen in the assays. Further experiments have suggested that S2F10 may be produced and accumulate under the specific decomposition conditions and that this compound may be a major contributor to the observed cell lethality. It is concluded that testing of samples from commercial facilities and assays of decomposed gas after ameliorative treatments would both be appropriate investigations  相似文献   

10.
The ultra-high frequency (UHF) technique of partial discharge detection has been used to study the partial discharges produced by electrode protrusions and surface contamination in a gas insulated substation (GIS). The paper describes the stages of discharge development from inception to breakdown. The work has shown that the UHF technique may be used to identify distinct phases of discharge activity corresponding to discharge inception and a prebreakdown condition. The prebreakdown activity is detected as an increase in the UHF signal magnitude which has been attributed to the formation of leader-type discharges. These discharges form an essential part of the breakdown process, and their detection can be used to identify when the system is close to breakdown. The paper describes a filtering technique that may be employed to optimize the sensitivity of UHF leader detection  相似文献   

11.
A new method for the calculation of parameters of SF6 insulation for extra HV GIS disconnectors is given. This method is based on a new criterion for leader inception, which is connected with the value of the peripheral electric field near the boundary of the streamer zone. The presence of such a critical field is confirmed by analysis of experimental results and physical considerations  相似文献   

12.
为了给电气设备中的SF6新气质量控制提供参考,研究了SF6新气中痕量杂质对电气设备运行寿命的影响。通过一个与电流互感器共气室的直线隔离开关装置,模拟了中心导杆上金属尖端放电内部缺陷。在220kV单电压和220kV、3 150A同步升流升压2种方式下,分别充入不同品质的SF6新气进行约100h的试验。并采用SF6气相色谱质谱分析技术、加拿大SF6杂质分析仪DPD,跟踪检测SF6气体痕量杂质各组分体积分数变化情况。结果表明,设备中充入低品质SF6新气(含有较高浓度的全氟烷烃、氟化硫酰、及碳硫氟化物等多种杂质),在放电末期产生较多的SO2F2、SOF2和SO2。而酸性的SO2对设备具有腐蚀作用,因此,当SF6新气中痕量杂质过高时,其充入电气设备后,将减少SF6电气设备运行寿命,尤其是开断设备。  相似文献   

13.
Using an experimental apparatus modeled for a gas-insulated switchgear (GIS), the influence of the arc duration on the breakdown voltage between the contact and the grounded tank of the GIS was investigated in the case that the arc was kept ignited in the contact area. From the result, characteristics of the breakdown voltage vs. the arc duration were found to be divided into six stages and the characteristics in each stage were estimated  相似文献   

14.
通过检测SO2发现SF6电气设备故障   总被引:18,自引:0,他引:18  
通过几例SF6电气设备故障的分析和检出,说明检测SO2能够诊断SF6电气设备故障。SO2是SF6主要分解物SOF2的水解产物,是稳定气体,在分解物中一般含量较高,当故障涉及到固体绝缘材料时,SO2含量更高,检测SO2方法很多,用检测管简易方便,有足够的灵敏度。  相似文献   

15.
Surface flashover characteristics of solid spacers in a rod-plane configuration have been investigated in SF6, at pressures to 400 kPa, for switching impulse voltages to determine the effect of spacer, spacer materials and polarity of applied impulses. The effect of spacer material on the flashover voltage is not significant. For negative polarity impulses, the influence of the spacer is also insignificant. But for positive polarity impulses, at pressures <200 kPa, the spacer efficiency becomes >1.0. On the other hand, at pressures >200 kPa, the presence of the spacer drastically reduces the flashover voltage of the system. At about atmospheric pressure also, the spacer efficiency in air has been found to be >1.0, with the same electrode geometry  相似文献   

16.
17.
18.
Prediction of fast transient voltage-induced breakdown in quasi-homogeneous field geometries requires compounding the breakdown probability over time, while taking into account the field-dependent probability of electron detachment. In this paper, a breakdown probability model has been developed to predict the impulse breakdown under quasi-uniform fields, as this is the fundamental condition, the knowledge of which facilitates computation of breakdown probability under more complex conditions. The model will facilitate computation of breakdown probability under more complex conditions. It accounts for the effect of the streamer formation length on the critical volume and the probability of initial electron production by electron detachment from negative ions. The proposed model has been verified through comparison with the measured impulse breakdown probabilities. The predicted breakdown probabilities are in good agreement (±10%) with those measured  相似文献   

19.
探讨SF6气体变压器的应用   总被引:1,自引:0,他引:1  
李振辉 《广东电力》2001,14(3):63-64,67
介绍了香港电灯公司使用SF6气体变压器的情况,比较了气体变压器与油变压器的优缺点,提出了使用气体变压器的必要性和可能性。  相似文献   

20.
With the goal of reducing SF6 gas usage, we investigated partial discharge (PD) and breakdown (BD) mechanisms in ultra-dilute (0 to 1%) SF6/N2 gas mixtures. The experimental results and discussions are given in this paper. In particular, we focused our research on the transition characteristics of the electrical insulation performance with an extremely small amount of SF6 content, the PD behavior on the applied voltage, and the relation among prebreakdown streamer, return stroke and BD. Moreover, we discussed the PD and so mechanisms with reference of space charge behavior. From these results, the transition threshold at which the influence of SF6 gas on the discharge characteristics began to appear, was clarified to be SF6 content k=10 ppm for a total pressure of 0.1 MPa  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号