首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The Analysis Committee has collaboratively tested both routine headspace gas chromatographic methods and a standardised method for the determination of dimethyl sulphide in beer using the flame photometric and flame ionisation detectors available in the participating laboratories. The mean repeatability value (r95) was 7.8 μg/litre for the concentration range 12–65 μg/litre, and the reproducibility value (R95) showed the relationship R95 = 18.1 + 0.452m μg/litre to the concentration (m). No differences in precision were attributed either to the methods or the types of detectors used.  相似文献   

2.
A method relying on headspace sampling and gas chromatography for the determination of the lower boiling point volatile compounds (fusel oils) in beer, has been approved by the Analysis Committee of the Institute of Brewing (IOB), for inclusion in Recommended Methods of Analysis. In view of the large values obtained for precision in terms of repeatability (r95) and reproducibility (R95) and the differences in gas chromatographic equipment used by individual brewing laboratories, the method is considered not to be ideal, but is given as a guideline only. The IOB Analysis Committee has recommended a method relying on gas chromatography and flame photometric detection for the determination of dimethyl sulphide in beer. Repeatability (r95) and reproducibility (R95) values of 3.3 μg/litre and 3.66+0.168 m μg/litre (where m is concentration), respectively, were obtained over the range 20–50 μg/litre. Methods currently used in brewing laboratories, for the measurement of vicinal diketones, are being surveyed with a view to obtaining a suitable method for collaborative testing by the Analysis Committee.  相似文献   

3.
A method for the determination of aluminum in beer, has been collaboratively tested. The method tested relies on atomic absorption spectrometry with atomization in a graphite furnace. Five pairs of beers, with concentrations ranging from 96 to 1000 μg/litre, were analysed by eleven laboratories. The repeatability (r95) values ranged from 10 to 69 μg/l, and the reproducibility (R95) values ranged from 70 to 465 μg/l,. A second collaborative trial with a slightly different method protocol gave no improvement. Due to the high reproducibility values the method was not adopted for inclusion in Analytica-EBC.  相似文献   

4.
Two methods for the determination of vicinal diketones in beer have been collaboratively tested by the Analysis Committee of the Institute of Brewing and are recommended for use. Both methods employ gas chromatography and are essentially the same, except that one relies on the use of a packed column and the other on a capillary column. For diacetyl it was judged that repeatability (r95) values were independent of concentration over the range 0.04 to 0.19 mg/litre. Over this range, r95 values for diacetyl of 0.028, 0.020 and 0.026 mg/litre were obtained for capillary, packed columns and combined results respectively. Values for reproducibility (R95) were judged to be dependent on the mean level (m). R95 values were 0.032 + 0.68 m, 0.01 + 0.47 m and 0.005 + 0.67 m were obtained for capillary, packed columns and combined results respectively. For both methods the r95 and R95 values for 2,3-pentanedione were judged to be independent of concentration over the range 0.02 to 0.07 mg/litre. For capillary columns, packed columns and combined results respectively, r95 values were 0.009, 0.009, 0.010 mg/litre and R95 values were 0.037, 0.042 and 0.038 mg/litre.  相似文献   

5.
A method relying on ion chromatography, with suppressed ion detection, for the determination of anions in beer, has been collaboratively tested by members of the American Society of Brewing Chemists, the European Brewery Convention and the Brewery Convention of Japan. Precision values obtained for the determination of chloride, sulphate and phosphate in beer were judged to be acceptable. Repeatability (r98) and reproducibility (R98) values for chloride were 5.7, 12.6, 12.5 and 15.0, 38.4, 36.8 respectively at corresponding mean levels of 68.7, 218.6 and 322.5 mg/litre. r98 and R98 values for sulphate were 7.5, 6.2, 7.6 and 44.8, 54.0, 46.5 respectively at corresponding mean levels of 101.4, 205.1 and 122.6 mg/litre. r98 and R99 values for phosphate were 14.1, 11.9, 24.9 and 78.7, 53.8, 84.0 at corresponding mean levels of 411.5, 224.1 and 397.5 mg/litre. Whilst the r98 value for nitrate was acceptable, the value for R98 was unsatisfactory. The ion chromatographic method for determining chloride, sulphate and phosphate in beer is recommended for use and inclusion in Analytica -EBC as an International Method.  相似文献   

6.
The Institute of Brewing Analysis Committee has collaboratively tested four methods for the determination of sulphur dioxide in beer over the range 1 to 40 mg/litre. The p-rosaniline method (r95 = 0.51 + 0.10 m. R95 = 0.63 + 0.26 m) was found to have the best precision and is recommended as an alternative to the Monier Williams method (r95 = 0.43 + 0.15 m, R95 = 1.86 + 0.27 m) where high precision at low sulphur dioxide levels is required. The dithiobisnitrobenzoic acid (DTNB) method and the IOB rapid distillation method showed considerably worse precisions.  相似文献   

7.
1A method, relying on ion chromatography, for the determination of nitrate in beer, has been collaboratively tested by members of the European Brewery Convention (EBC) and the Brewery Convention of Japan (BCOJ). Precision values were judged to be acceptable. Repeatability (r95) and reproducibility (R95) values were 1.5, 0.96, 5.1, and 9.3, 10.4, 13.5 respectively for corresponding mean levels of 6.5, 26.2 and 52.8 mg/litre. However, r95 and R95 values of 1.5 and 2.3 respectively were obtained for an aqueous solution of nitrate ions at a mean level of 20.7 mg/litre. The determination of nitrate is recommended for use and inclusion in Analytica-EBC, as an additional analyte in the International Method which relies on ion chromatography for estimating chloride, sulphate and phosphate.  相似文献   

8.
A simple spectrophotometric method for the determination of nitrogen in unhopped wort has been tested by the EBC Analysis Committee and accepted for inclusion in Analytica-EBC. The spectrophotometric method is intended as a quick method for routine quality control. It is emphasized that the procedure has to be followed in detail and that the precautions stated under Notes on Procedure are most important. The average precision values obtained for the range 600 to 850 mg/litre were r95=30 and R95 = 104.  相似文献   

9.
The Analysis Committee has collaboratively tested local routine headspace gas chromatographic methods for the determination of the lower boiling point volatile compounds in beer. The repeatability values (r95) were dependent upon mean concentration (m) for acetaldehyde and alcohols but not for esters, whilst reproducibility values (R95) were dependent upon concentration in all cases. The range of values of m and the estimates of r95 and R95 (mg/litre) for each compound were, respectively: acetaldehyde (5–8, 0.21m, 0.60m); propanol (9–23, 0.25m, 2.5+0.57m); isobutanol (5–22, 0.56+0.085m, 1.7+0.15m); methylbutanols (45–105, 0.14m, 0.22m); ethyl acetate (10–54, 3.1, 2.1+0.29m); isoamyl acetate (0.8–4.7, 0.36, 0.20+0.58m); and ethyl hexanoate (0.13–0.36, 0.073, 0.10+0.91m). No advantage was gained by diluting beer samples containing 9% V/V ethanol to 4% ethanol (used for the calibration mixtures) prior to analysis, but use of a standard method of sample preparation decreased most of the R95 values. No recommendation is made in this interim report.  相似文献   

10.
A procedure for preparing torrefied products for analysis has been examined and the effects of this procedure on the determination of laboratory extract and colour have been collaboratively tested by the Analysis Committee of the Institute of Brewing. White malts of DP levels 50° and 100° IOB were used as the sources of enzymes in the mixed mash procedure. With these malts r95 and R95 values for extract of the torrefied products ranged from 1.7 to 10.2 and 12.4 to 21.9 resp. on mean extracts ranging from 244 to 270 litre °/kg. The r95 and R95 values for colour ranged from 1.6 to 2.3 and 2.2 to 3.8 resp. on mean colours ranging from 2.7 to 3.5 EBC units.  相似文献   

11.
The Analysis Committee of the European Brewery Convention has recommended that the Hot Water Extract procedure for malt, which relies on a coarse grind and single temperature mash (65°C), is included in Analytica-EBC, as an additional method to that of the EBC Extract procedure. The Committee accepted the precision values obtained by the Institute of Brewing on the 1984 Check Malt. Repeatability (r95) and reproducibility (R95) values in litre degrees/kg were 2.14 and 3.48 respectively, for mean value of 295.3 at a Miag 0.7 mm setting, and 1.93 and 2.90 respectively, for a mean value of 298.2 at a Miag 0.2 mm setting.  相似文献   

12.
The Institute of Brewing Analysis Committee has organised two collaborative trials for the analysis of alcohol using the ServoChem Automatic Beer Analyser (SCABA). The mean repeatability (r95) values for the two trials were 0.051% and 0.034% V/V respectively. The value for the second trial could however be judged to be dependent on concentration (m) at 0.008m% V/V. The Reproducibility (R95) values of both trials were judged to be dependent on concentration at 0.027m% V/V and 0.025m% V/V respectively. The combined data for the two trials gave r95 = 0.044% V/V and R95 = 0.026m% V/V.  相似文献   

13.
A procedure relying on high performance liquid chromatography for the estimation of iso-alpha-acids in beer has been collaboratively tested by the IOB Analysis Committee. In addition the trial samples were analysed by the IOB Recommended Method for the measurement of bitterness (BU). It was judged that the results obtained by the HPLC method were not sufficiently precise to permit adoption as a Recommended Method. However, since the method has the advantage of measuring bitterness in terms of iso-alpha-acids, it is suggested as an alternative to that of the Recommended Method. The iso-alpha-acids are absorbed from beer on to a C18 Bond Elut column and then selectively desorbed prior to isocratic analysis by HPLC using an eluting solvent of methanol/water/phosphoric acid/tetrabutylammonium hydroxide and a C18 radialpak cartridge. For both methods the repeatability values (r95) were not dependent upon mean concentration (m) whereas the reproducibility values (R95) were dependent upon concentration. The values of (r53) and (R95) obtained were 2.11 and (1.38 + 0.134 m) over the concentration range 13.8 to 34.0 mg/litre for the HPLC procedure and 1.20 and (0.76 + 0.122 m) over the concentration range 15.4 to 38.6 BU for the Recommended Method.  相似文献   

14.
A method employing a density meter for the determination of specific gravity (SG) has been tested for the determination of the gravity (G) of beer, aqueous sugar solutions and aqueous ethanol solutions by the Analysis Committee of the Institute of Brewing. The term “gravity”, used throughout this report is defined by the equation G = SG × 1000. Repeatability (r95) and reproducibility (R95) values were calculated over the range 994.6 to 1124.2 gravity. For beer, it was judged that precision values were independent of the gravity of the sample. Values for r95 and R95 were 0.1 and 0.9, respectively, for instruments with a 5 figure display and 0.08 and 0.32, respectively, for instruments with a 6 figure display, over the range 999.1 to 1017.0 gravity. For solutions of ethanol in water, precision was also independent of the gravity of the sample. Values for r95 and R95 were 0.1 and 0.3, respectively, for instruments with a 5 figure display and 0.05 and 0.19, respectively, for instruments with a 6 figure display, over the range 994.6 to 999.1 gravity. For aqueous sugar solutions the values of r95 and R95 increased with increasing gravity. At 1049.3 gravity, values for r95 and R95 were 0.1 and 0.8, respectively, for instruments with a 5 figure display and 0.07 and 0.35, respectively, for instruments with a 6 figure display. At 1124.2 gravity values for r95 and R95 were 0.2 and 1.4, respectively, for instruments with a 5 figure display and 0.16 and 1.35, respectively, for instruments with a 6 figure display.  相似文献   

15.
The international method for the determination of the soluble iron content of filter aids has been collaboratively tested by members of the Analysis Committee of the European Brewery Convention to obtain repeatability (r98) and reproducibility (R98) values. It was Judged that precision values were dependent on the quantity of the soluble iron content of the filter aids over the range 32 to 220 mg/kg. Repeatability (r98) value of 0.050 m and reproducibility value (R98) of 0.255 m were obtained over this range.  相似文献   

16.
Six identical gas chromatographic (GC) systems from the same manufacturer were evaluated for the determination of ethanol in beers. Each system was assessed for detector linearity and drift using standard ethanol solutions. Repeatability (r95) of each machine, repeatability (r95) of the GC method and reproducibility (R95) of the method over a range of ethanol concentrations (1–11% V/V) was determined using commercial beers. All six instruments were linear over the ethanol range 0–12% V/V and were in good agreement. Drift of the machines was negligible over the period of the analysis. Over the ethanol range 0.95 to 6.32% V/V the repeatability (r95) and reproducibility (R95) values were 0.050 and 0.083 respectively. Over the ethanol range 9.48 to 11.15% V/V the repeatability (r95) and reproducibility (R95) values were 0.153 and 0.227 respectively. Comparison of the precision values and those obtained in a recent IOB Analysis Committee Collaborative1 for the determination of ethanol by gas chromatography showed no significant differences between the two methods. The reported method is suitable for determination of ethanol in beers.  相似文献   

17.
A viscometric method for estimation of endo beta-glucanase activity in malt has been collaboratively tested by the Institute of Brewing Analysis Committee. Ten participating laboratories analysed five pairs of malt samples in the range 176 to 1238 IRV units. The repeatability (r95) values ranged from 22 to 122 IRV units and the reproducibility (R95) values from 93 to 650 IRV units. The results indicated that R95, but not r95, was dependent on endo beta-glucanase activity. Overall precision values were 76.8 for r95 and 0.506Mean + 4.786 for R95. It was decided that the method would be included in IOB Methods of Analysis but that attention would be drawn to the poor precision values obtained in this and previous collaborative trials.  相似文献   

18.
The International Method for the determination of the colour of beer has been tested by members of the Analysis Committee of the European Brewery Convention on samples of wort produced from a laboratory extract of malt using methods EBC 4.4 and EBC 4.4.5. The method, which relies on the spectrophotometric determination of colour at 430 nm, on clarified worts, is recommended as the designated reference method in place of the current visual method using EBC colour discs. The change will take effect from 1st January 1996. It was judged that precision values were dependent on the intensity of the colour of the sample over the range 3.6 to 25.3 EBC units. Repeatability (r98) and Reproducibility (R98) values of r98 0.18Mean ? 0.28 and R98 = 0.13Mean + 0.46 were obtained over this range.  相似文献   

19.
The method of the International Organization for Standardization, (ISO 712–1985) for the determination of moisture in cereals and cereal products, has been tested by members of the Analysis Committee of the European Brewery Convention on samples of barley. The method, which relies on loss in mass on drying at 130–133°C for 2 h, is recommended for use as a replacement for the current method, based on loss in mass on drying at 105–107°C for 3 h. It was judged that precision values were independent of concentration over the range 11 to 13% m/m. Repeatability (r95) and Reproducibility R95) values of 0.13 and 0.55 respectively were obtained over this range. At a mean level of 21.7% m/m, the r95 and R95 values were 0.27 and 2.6 respectively. This was probably due to errors associated with the double drying technique which is necessary for samples at this moisture content.  相似文献   

20.
The method for the determination of germinative capacity of barley using hydrogen peroxide and peeling technique (EBC 3.5.2) was revised in 1995. The revised procedure has been collaboratively tested by the EBC Analysis Committee. The repeatability (r95) and reproducibility (Rob) values were dependent upon mean values, r95 = (64.23-0.64m) % and R95 = (51.74-0.50 m) % .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号