首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Cadaver knee joints were mounted so that life-like forces of weight-bearing were simulated. The patello-femoral contact areas were defined under load throughout the range of movement by the dye method. During movement from extension to 90 degrees of flexion a band of contact sweeps across the patella from inferior to superior pole, but the odd facet makes no contact. At about 135 degrees of flexion separate medial and lateral contact areas form, the medial one limited to the odd facet. From extension to 90 degrees of flexion the patella holds the quadriceps tendon away from the femur, but in further degrees of flexion an extensive "tendo-femoral" contact area forms. Between 90 degrees and 135 degrees of flexion the patella rotates and the ridge between the medial and odd facets engages the femoral condyle. The odd facet is shown to be a habitual non-contact area and the ridge to be subject to high load, observations which correlate with cartilage lesions described in Part 2 of the paper.  相似文献   

2.
The meniscal impingement syndrome consists of three elements: impaction on the anterior medial femoral condyle by the leading edge of the medial meniscus, articular cartilage damage of at least Outerbridge grade 3, and knee hyperextension of at least 5 degrees. This report reviews this condition in a series of seven knees with an average follow-up of 39 months. The time from the onset of symptoms until surgery averaged 45 months. Treatment consisted of a thorough arthroscopic knee evaluation and debridement of the articular cartilage fragmentation and any impinging synovitis. Postoperative rehabilitation includes extension block bracing, hamstring strengthening, and closed-chain exercise. With this regimen, there was improvement in the Tegner scores and a reduction in postoperative knee hyperextension. Identification of this uncommon condition requires a complete evaluation of the medial femoral condyle in patients with knee hyperextension.  相似文献   

3.
A large Q angle induced by technical error such as an internally rotated femoral component causes patellar failure after total knee arthroplasty. The effect of medial displacement of the tibial tubercle to decrease the Q angle for patellar tracking was studied by evaluating the patellar position relative to the patellar groove on the femoral component in cadaver specimens. A 5 degrees internally rotated femoral component caused the patella to shift medially about 5 mm, and also caused the tibia to rotate internally about 3 degrees at full extension. With a 5 degrees externally rotated femoral component, normal patellar tracking occurred. The distance of medial displacement was determined so that the patellar tendon was parallel to the longitudinal axis of the tibia at full extension. This allowed the quadriceps tendon, the patella, and the patellar tendon to form a straight line. The average distance of medial transposition of the tibial tubercle was 9.32 mm. Medialization of the tibial tubercle caused the patella to shift about 2 mm medially from the patellar groove. The transfer also caused an external rotation of the tibia (2 degrees-5 degrees). Medial transfer of the tibial tubercle changes patellar kinematics and corrects the tendency toward lateral patellar dislocation caused by internally rotating the femoral component; however, it also creates minor patellar and tibial kinematic changes that may have a clinical effect.  相似文献   

4.
In a laboratory study using seven fresh-frozen anatomic specimen knees, the effect of total knee arthroplasty on the three-dimensional kinematics of the patella, femur, and tibia were measured. Experiments were performed in the intact knee, after division of the anterior cruciate ligament (ACL), after total knee arthroplasty, and after 10 degrees internal rotation, 10 degrees external rotation, 5-mm medial shift, and 5-mm lateral shift of the femoral component on the femur. The presence of a high lateral ridge on the anterior surface of the femoral component effectively prevented patellar subluxation or dislocation, but displaced and tilted the patella medially. Internal rotation or medial displacement of the femoral component exaggerated this medial patellar displacement and shift. External rotation of the femoral component corrected it, except at flexion angles greater than 100 degrees, where the femur was shifted medially on the tibia and externally rotated 15 degrees. This combination produced a net 10-mm medial displacement of the patella relative to the tibia at 120 degrees knee flexion. Lateral placement of the femoral component compensated for the effect of the high lateral ridge and allowed more normal patellar tracking while allowing tibiofemoral motions similar to those seen after sectioning of the ACL. The kinematics of the patellofemoral and tibiofemoral joints were not reproduced with a total knee prosthesis that sacrifices the ACL. When using a prosthesis with a high lateral ridge, lateral placement of a femoral component prevented patellar dislocation and allowed patellar tracking patterns similar to those seen in the intact knee without further altering tibiofemoral motions.  相似文献   

5.
From 1989 to 1996, 61 patients, including 66 knees, aged 8 to 62, were diagnosed as mediopatellar plica syndrome of knee after arthroscopic examination. Twenty-one cases were misdiagnosed as medial meniscal lesions before arthroscopic examination. Fifty-nine patients (64 knees) underwent arthroscopic resection of the plicae and 2 patients underwent opened resection. Fifty-nine cases had an average follow-up of seven months. Fifty cases (54 knees) of them showed excellent and good results.  相似文献   

6.
A study was conducted to determine in vivo femorotibial contact patterns for subjects having a posterior cruciate retaining or posterior cruciate substituting total knee arthroplasty. Femorotibial contact of 72 subjects implanted with a total knee replacement, performed by five surgeons, was analyzed using video fluoroscopy. Thirty-one subjects were implanted with a posterior cruciate retaining total knee replacement with a flat polyethylene posterior lipped insert, 12 with a posterior cruciate retaining total knee replacement with a curved insert, and 29 with a posterior cruciate substituting total knee replacement. Each subject performed successive deep knee bends to maximum flexion. Video images at 0 degree, 30 degrees, 60 degrees, and 90 degrees flexion were downloaded onto a workstation computer. Femorotibial contact paths were determined for the medial and lateral condyles using an interactive model fitting technique. Femorotibial contact anterior to the tibial midline in the sagittal plane was denoted as positive and contact posterior was denoted as negative. Analysis of average femorotibial contact pathways of both posterior cruciate retaining designs revealed posterior femorotibial contact in full extension with anterior translation of femorotibial contact commonly observed in midflexion and terminal flexion. In posterior cruciate substituting designs, anterior femoral translation was seen medially at 30 degrees to 60 degrees flexion but rarely was observed laterally. Posterior femoral rollback laterally from full extension to 90 degrees flexion was seen in 100% of subjects implanted with a posterior cruciate substituting total knee replacement, versus 51.6% (posterior lipped polyethylene insert) and 58.3% (curved insert) of those with a posterior cruciate retaining total knee replacement. Data from this multicenter study are remarkably similar to previous fluoroscopy data from a single surgeon series, showing a lack of customary posterior femoral rollback in both posterior cruciate retaining designs, and conversely showing an average anterior femoral translation with knee flexion. Posterior femoral rollback, less than in normal knees, routinely was observed in posterior cruciate substituting total knee arthroplasty, attributed to engagement of the femoral component cam with the tibial post. The abnormal anterior femoral translation observed in posterior cruciate retaining total knee arthroplasty may be a factor in premature polyethylene wear observed in retrieval studies.  相似文献   

7.
Compressive contact stress between the patella and the anterior femur and between the quadriceps tendon and anterior femur was measured before and after total knee arthroplasty in 5 cadaver knee specimens using a digital electronic sensor. Contact stresses were measured in the normal knee and after total knee arthroplasty with an unresurfaced patella, a dome-shaped patella, and a conforming patella. Patellofemoral contact stresses did not change significantly after total knee arthroplasty when the patella was not resurfaced, but they increased significantly after the patella was resurfaced with both the dome-shaped and the conforming components. The conforming patella had the highest contact stresses because it tilted at flexion angles greater than 90 degrees and applied load to a small area on the superior portion of the patellar component. The conforming patella markedly decreased tendofemoral contact force because the thicker superior pole of the patella tented the quadriceps tendon at flexion angles greater than 120 degrees. This further increased patellofemoral contact force in deep knee flexion.  相似文献   

8.
PURPOSE: Our goal was to evaluate the diagnostic value of MRI in plica syndrome. METHOD: MR images of a patient group (n = 55) with arthroscopically confirmed pathologic mediopatellar plicae were retrospectively analyzed and compared with those of a control group (n = 100). We obtained axial multiplanar gradient-recalled (MPGR), axial T1-weighted, and sagittal T2-weighted MR images. MR images were assessed for the width and length of all medial plicae. RESULTS: In the diagnosis of plica syndrome, sensitivity and specificity were 73 and 78% on axial MPGR images, 71 and 83% on sagittal T2-weighted images, and 95 and 72% on combination of both images, respectively. The incidence of pathologic medial plica increased with a criterion of extension beyond the medial end of the patella on axial MPGR images. CONCLUSION: MRI is a useful screening method in the diagnosis of plica syndrome.  相似文献   

9.
The effect of total knee arthroplasty (TKA) with neutrally aligned and malrotated tibial trays was studied in five fresh anatomic specimen knees. Patellar shift, tilt, and rotation, and the rotational position of the tibia were measured in normal knees and after TKA with the Ortholoc Modular knee system. Both semiconstrained and unconstrained articular surfaces were assessed in the neutral position and at anatomic, 15 degrees internal, and 15 degrees external rotation of the tibial tray. After TKA, the patellae shifted slightly medially in the early phase of knee flexion because the anterior lateral flange of the femoral component was longer than the lateral trochlea of the femur and because the tibia rotated internally. The raised lateral flange on the femoral component tilted the patella medially at full extension after TKA. The semiconstrained tray allowed minimal tibial rotation because of its articular configuration. As much as 15 degrees malrotation of the unconstrained tibial tray did not affect patellar tracking. The semiconstrained tibial tray in the neutral position had almost the same patellar tracking as the unconstrained tray, but at 15 degrees external rotation, the semiconstrained tray internally rotated the tibia, leading to medial shift of the patella. Although 15 degrees internal rotation caused external rotation of the tibia, the patella did not shift as much laterally, despite the increase in the Q angle.  相似文献   

10.
An autologous graft from the lateral facet of the patella was used to repair a large osteochondral defect of the weight-bearing surface of the femoral condyle in ten patients who were then followed for an average of six and one-half years (range, four to nine years). Function was improved and symptoms were alleviated in all of the patients. Four patients had mild pain in the anterior part of the knee and two patients had a flexion deformity, which was 5 degrees in one and 10 degrees in the other. Small osteophytes developed laterally in five of the patients; three of the five had pain in the anterior part of the knee and two had a mild lateral patellar tilt.  相似文献   

11.
Resurfacing the patella or not in total knee arthroplasty is generally still a quite controversial topic. In that context we felt a necessity to get more informations about the natural history of a non resurfaced patella in the prosthetic surrounding than only in comparison with a replaced patella. By the fact that we haven't been replacing patellae apart from special cases since up to five years, we have available a patient selection on which this question can be studied. Thirty primary total knee replacements with documented 2 year's follow up have been investigated by calculation of the radiological patellar shift and tilt relative to the natural groove on preoperative X-rays and to the prosthetic groove in the postoperative evolution. These results were matched with the range of motion obtained after two years and with persisting pain. Only mobile polyethylene inlays had been used. With regard to the patella no difference was found for one single complete tibial tray or two separately implanted unicompartimental tibial trays. As a rule an adaptation of the bony patellar contour to the prosthetic groove was observed with an increased density of the bony contact area with or without a fibrous interstitial layer. Based on their clinical follow up examination seven patients had to be adjointed to a "residual problem group", as they presented persisting pain (3) or a poor range of motion of 90/0/0 degree of flexion/extension or less. Only in this group we found cases with a postoperative shift over 5 mm (2) and a postoperative tilt over 15 degrees (3). Inside this group, also with a significant difference from the group without residual problems, there was furthermore a correlation between persisting pain and an important preoperative tilt and between a diminished range of motion and a considerable preoperative shift. It has to be pointed out that even the cases without long severe malposition before the arthroplasty but with unsatisfactory realignement referring to the patellar tilt (7 degrees-15 degrees) have been found pain free at the last follow up. One patient with a severe secondary increase of disalignment (16 mm/139 degrees) due to an aseptic tibial loosening represents a particular case. After corrective revision of the tibial implants this patient also got again a complete pain relief and a good range of motion without any surgical measure to the patella and inspite of an evident residual tilt. Thus we have to conclude that it is justified to take important pains with the realignment to obtain a residual patellar shift of less than 5 mm. Apart from usual operative steps during the implantation to favour a good patellar tracking, e.g. a high quadriceps release or a medially transposed refixation of the detached tibial tubercle can get necessary. On the other hand a residual tilt up to 15 degrees is well tolerated, as the unresurfaced patella presents an astonishing ability of adaptation to the prosthetic groove by remodelling of the bony contour and structure. Nevertheless in the included cases of severe preoperative malposition, in which we didn't replace the patella because of a good intraoperative bone quality, we had to put up with an increased incidence of late problems even with normalized patellar tracking. In such cases an extended indication to a patellar resurfacing may be considered.  相似文献   

12.
We report the effects of femoral tunnel position and graft tensioning technique on posterior laxity of the posterior cruciate ligament-reconstructed knee. An isometric femoral tunnel site was located using a specially designed alignment jig. Additional femoral tunnel positions were located 5 mm proximal and distal to the isometric femoral tunnel. With the graft in the proximal femoral tunnel, graft tension decreased as the knee flexed; with the graft in the distal femoral tunnel, graft tension increased as the knee flexed. When the graft was placed in the isometric femoral tunnel, a nearly isometric graft tension was maintained between 0 degrees and 90 degrees of knee flexion. One technique tested was tensioning the graft at 90 degrees of knee flexion while applying an anterior drawer force of 156 N to the tibia. This technique restored statistically normal posterior stability to the posterior cruciate ligament-deficient knee between 0 degrees and 90 degrees for the distal femoral tunnel position, between 0 degrees and 75 degrees for the isometric tunnel position, and between 0 degrees and 45 degrees for the proximal tunnel position. When the graft was tensioned with the knee in full extension and without the application of an anterior drawer force, posterior translation of the reconstructed knee was significantly different from that of the intact knee between 15 degrees and 90 degrees for all femoral tunnel positions.  相似文献   

13.
14.
This study measured the patellar lateral force-displacement behaviour at a range of knee flexion angles in normal human cadaver specimens. The knee extensor muscles were loaded in proportion to their physiological cross-sectional areas, the tensions being applied in physiological directions along the separate quadriceps muscles. Knee extension was blocked at a range of knee flexion angles from 0 to 90 degrees, and patellar lateral displacement versus force characteristics were measured. This experiment was repeated with three total muscle forces, 20, 175 and 350 N, which were held constant at all flexion angles. It was shown that similar stability variation was obtained with the different total muscle loads, and also the forces required to produce a range of patellar displacements (1.5, 9 mm) were examined. A 5 mm lateral patellar displacement required a constant displacing force (i.e. the patella had constant lateral stability) up to 60 degrees knee flexion, and then a significant increase at 90 degrees. The results were related to surgical and anatomical observations.  相似文献   

15.
A review of 356 Kinemax (Howmedica, Inc, Rutherford, NJ) cemented posterior cruciate ligament-retaining condylar total knee arthroplasties employing a symmetrical femoral component articulating with a medially offset symmetrical dome patella component was carried out to examine the results and determine the incidence and nature of the patellofemoral complications. Follow-up was from 3 to 8 years, with a mean of 5.1 years. A review of patellofemoral complications in previously reported homogeneous series of symmetrical and asymmetrical implants is presented. Mean postoperative Knee Society scores improved to 91, function scores to 86, and Hospital of Special Surgery scores to 90 yielding 95% good and excellent results. Mean postoperative range of motion was -1.5 degrees extension to 113 degrees flexion. There were five patellofemoral complications (1.4%), including two symptomatic subluxations, two distal pole avulsion fractures, and one lateral facet fracture. There were two reoperations necessary for patellofemoral problems (0.56%), one to correct subluxation and one for excision of the fractured lateral facet. These rates are lower than those previously reported for asymmetrical implants as well as current and phased-out symmetrical designs of total knee arthroplasty in the intermediate term. This review suggests that cemented total knee arthroplasty with symmetrical patellofemoral resurfacing with an offset patella dome and posterior cruciate ligament retention yields low patellofemoral complications and reoperations. The symmetrical femoral component appears to be a satisfactory compromise of "normal" femoral anatomy, which decreases inventory and cost without adversely affecting patellofemoral function and complications.  相似文献   

16.
We created a model to see if twisting the graft in an anterior cruciate ligament reconstruction affected the distance separating the femoral and tibial attachments of the perimeter fibers of a patellar tendon graft. Graft bone plugs were simulated by two 12.5-mm diameter Delrin cylinders. Holes, 1 mm in diameter, were placed at the four corners of a centralized rectangle measuring 5 by 10 mm. Graft ligament fibers were represented by color-coded sutures passed through the holes in the modeled bone plugs. This graft model was fixed in tunnels reamed under arthroscopic guidance at the anterior cruciate ligament attachment sites of the femur and tibia in six fresh-frozen knee specimens. Spring gauges were used to measure indirectly the changes in distance of separation during knee flexion between the femoral and tibial attachments relative to a zero defined at 90 degrees of knee flexion. The tibial cylinder was rotated at 45 degrees increments from 90 degrees external to 180 degrees internal rotation relative to the femoral cylinder and measurements were repeated after each incremental rotation. External rotation resulted in a statistically significant higher mean separation distance (4.5 mm) for peripheral graft attachments than internal rotation (2.8 mm) (P = 0.05).  相似文献   

17.
Femoral condyle geometry was evaluated in 30 normal and 30 varus knees using magnetic resonance imaging. In the sagittal view, the distal part of the medial condyle was deformed in the varus knees, but there was no significant difference in the posterior part of the medial condyle between the normal and varus knees. In the transverse view, the transepicondylar axis (a reliable rotational landmark) showed approximately 6 degrees external rotation relative to the posterior condylar axis in the varus knees and the normal knees. The results of this study suggest that no hypoplasia exists at the posterior part of the medial condyle in varus knees. In addition, the posterior condylar axis may be a reliable rotational landmark but is in relative internal rotation in varus knees when total knee arthroplasty is performed.  相似文献   

18.
The plicae are synovial septa remaining in adult life that existed in early fetal life. The suprapatellar plica separates the suprapatellar pouch from the knee joint. The plica syndrome has clinical significance, which has been occasionally overlooked, but the pathophysiology of symptomatic plicae may be hard to explain. To evaluate the clinical significance of the suprapatellar plicae, the authors reviewed 34 cases in 23 patients with vague pain around the knee and a total septum of the suprapatellar plica at arthroscopic examination from September 1991 to December 1993. The follow-up period was from 6 months to 2 years and 9 months. The most common presenting symptom was chronic mild knee pain, aggravated by prolonged squatting or standing, with other patients reporting recurrent swelling, instability, giving-way, or a feeling of snapping. The objective findings include palpable band on the superomedial side, audible snapping, and local tenderness, but there were no significant abnormal findings in the laboratory. The radiographic findings were few, with sclerosis of the articular surface of the patella in 2(6%), malalignment in 1(3%), and mild degenerative change in 4 cases(12%). Five of 11 patients evaluated by bone scan had increased uptake around the patellofemoral joint, and 7 of 13 knees had a relatively small suprapatellar bursa on conventional arthrogram or pneumoarthrogram. At arthroscopy, a suprapatellar plicae with complete septum was identified in 30 of 34 cases (88%) and associated lesions presented as meniscal tears, loose body, and discoid meniscus without tear. The complete plicae were surgically excised under arthroscopic control in 30 patients and the results were excellent in 22 patients (73%), good in 5 (17%), and poor in 3 (10%)at 17 months follow-up; there were no failures. In our opinion, the complete suprapatellar plica is clinically significant in patients who have equivocal diagnosis of knee problems and further studies of the pathophysiology of complete suprapatellar plica are needed.  相似文献   

19.
In two cases of flexion contracture of knees, the vertical septum pattern of the infrapatellar plica was noted arthroscopically to be thickened, fibrotic, and to have lost its elasticity. The plicae were impinged to the intercondylar notch and trochlea at extension of the knees, blocking further extension. The pathological plicae were resected, followed by improvement in range of the knees. At 6 months postoperatively, the knees gained full extension. This is the first report showing that the infrapatellar plica caused a clinical symptom.  相似文献   

20.
An isometer, a highly compliant spring-scale device for measuring suture displacement, has been used intraoperatively by surgeons to select the optimal placement of the femoral tunnel for an anterior cruciate ligament graft. The isometer measures the displacement of a suture centered in a tibial tunnel and attached to an intraarticular location on the femur before the femoral tunnel is drilled. Because the placement of the femoral tunnel strongly impacts the tensile behavior of an anterior cruciate ligament graft and because surgeons have used the amount of suture displacement to guide the placement of the femoral tunnel, the objective of this study was to determine the ability of an isometer to predict graft tension. In 14 patients undergoing reconstructive surgery of the anterior cruciate ligament, an isometer was used to measure suture displacement during passive knee motion for a provisional femoral tunnel location. An electrogoniometer recorded the flexion angle of the knee. The femoral tunnel was drilled. A double-looped semitendinosus and gracilis autograft was inserted around a post in the femoral tunnel, and the tension in the four limbs of the graft exiting the tibial tunnel was measured during passive knee motion. Graft-tension versus knee-flexion-angle curves revealed that each knee exhibited one of two distinct curve shapes: L-shaped, characterized by the maximum tension occurring at full extension and a nearly flat profile from 35 to 90 degrees of flexion, or U-shaped, with elevated tensions at 80-90 degrees of flexion (p < 0.001) reaching at least half of the tension in full extension. Because the shapes of the suture-displacement versus flexion-angle curves were more consistently L-shaped, the intraoperative measurement of suture displacement was not a useful predictor of either the increase in tension in the graft with flexion or the maximum tension in the graft.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号