1.
ABSTRACT

The viscous flow fields around multifiber filters have been investigated in a previous paper. The results of the previous work show that the flow becomes periodic immediately after the first fiber array downstream from the entrance if the fibers are arranged uniformly along the flow direction. The characteristics of such flow fields enable the pressure drop and the particle interception efficiency of a multifiber filter to be represented by single-fiber models. The total filtration efficiency, however, cannot be so represented since fibers interact during filtration processes. In this study, the pressure drop and the interception efficiency were investigated by making use of the viscous flow fields modeled in the previous research. The fiber separation ratio was found to have significant effects on pressure drop and efficiency. At a given volume fraction, changes in the fiber separation ratio will result in changes to the patterns of fluid flow and aerosol particle motion. Therefore, the fiber separation ratio significantly affects pressure drop and interception efficiency.  相似文献   

2.

Deposition of polydisperse aerosols by Brownian diffusion was studied analytically using the penetration efficiency of monodisperse aerosols combined with the correlations among the moments of lognormal distribution functions. The analytic solutions, so obtained were validated using the exact solutions, which were applied to recalculate the filtration efficiencies of the existing experimental data for various filtration conditions. It was found that the collection efficiency of a fibrous filter should be corrected with respect to the position in the filter, if the particles are polydisperse. By considering the effect of the polydispersity of particle size, the analytic solutions showed good agreement with existing experimental data. It is believed that the present work makes it possible to determine the filtration efficiency of polydisperse aerosols in fibrous filters and to estimate errors associated with the degree of polydispersity of the particles quickly and accurately for the diffusion dominant regime.  相似文献   

3.
Electrospinning is a fabrication process that uses an electric field to make polymer nanofibers. Nanofibers have a large specific surface area and a small pore size; these are good properties for filtration applications. In this paper, the filtration characteristics of a Nylon 6 nanofilter made by electrospun nanofibers are tested as a function of the fiber diameter. Nanofilter media with diameters in the range of 100–730 nm can be produced in optimized conditions. The pressure drop of a Nylon 6 nanofilter linearly increases with the increasing face velocity. An electrospun Nylon 6 filter (mean fiber diameter: 100 nm) shows a much lower pressure drop performance relative to the commercial HEPA filter media when the filtration efficiency of the Nylon 6 nanofilter and the HEPA filter are over 99.98% with test particles of 0.02–1.0 μm in diameter. The pressure drop at 5 cm/s of the face velocity is measured as 27 mmAq for the Nylon 6 nanofilter media, and 37.1 mmAq for the HEPA filter media. The particle size with minimum efficiency decreases with the decreasing fiber diameter. And the minimum efficiency becomes greater as the fiber diameter is decreased.  相似文献   

4.
The purpose of this study was to compare the performance efficiency of melt-blown and currently used glass fiber filter media under the same environmental conditions. To evaluate filter efficiency, filter class was determined according to ISO and European standards (EN 1822-1:2009) using an automated filter tester (0.3 μm size), taking into account particle filtration, fractional efficiency for negative pressure devices, and consumption of electrical power. The average fractional efficiency, quality factor (QF), fractional efficiency by dust loading amount, pressure by dust loading amount, and QF by dust loading amount were higher in the case of melt-blown media than in the case of glass fiber filters. The fractional efficiency of hydrocharged melt-blown filters was higher than that of uncharged media. Based on performance efficiency, melt-blown filters are more effective high efficiency particulate air filters than glass fiber media.

Copyright © 2018 American Association for Aerosol Research  相似文献   


5.
With micron talcum particles and nano-CaCO3 powder as test dust, a series of experiments have been carried out to systematically study the gas filtration and regeneration behavior of polytetrafluoroethylene membrane, and some comparisons were made with common filter media. The experimental results showed that the PTFE membrane had a filtration efficiency of above 99.99% for micron particles, and excellent regeneration behavior was obtained, though a much higher initial pressure drop existed. Based on the results, it was concluded that the PTFE membrane is an excellent surface-filtration media for micron particles. Effects of operation parameters, including airflow velocity, particle concentration and particle characteristics were also investigated. To better understand the evolution of pressure drop during the filtration process, a mathematical model with operation parameters and characteristics of particles was derived from the gas-solid two-phase flow theories. A novel method on the determination of regeneration period of the filter media was put forward based on the analysis of the pressure drop according to this model.  相似文献   

6.

This paper experimentally examines the bounce and immediate re-entrainment of liquid and solid monodisperse aerosols under a stable filtration regime (precake formation) by wet and dry fibrous filters. PSL and DEHS were the solid and liquid aerosols, respectively, used in four monodisperse sizes of 0.52, 0.83, 1.50, and 3.00 w m. Three different fibrous filters were used to filter the aerosol streams, and the efficiency of the filtration process for each aerosol type under dry and wet regimes was measured. It was found that the solid particles generally exhibited a lower fractional filtration efficiency than liquid particles, although this difference decreased in the smaller size fractions. The difference between solid and liquid efficiencies was found to be greatest in the 1.5 w m size range. As particle sizes of liquid/solid aerosols and filtration parameters were similar, this difference is most likely to be due to the effect of particle bounce and or immediate re-entrainment occurring inside the filter, with the greater efficiency of filtration of the liquid particles being due to their greater capacity to plastically/elastically deform in order to absorb the impact forces. However, for the wet filtration regime (each fibre of the filter was coated by a film of water), no significant difference in filtration efficiency was detectable between solid and liquid aerosols. Therefore, the conclusion can be drawn that the either the bounce effect of the particles is inhibited by the liquid film, or the filtration conditions in the wet filter are so different that the aerosol properties are less significant with respect to capture.  相似文献   

7.
The increase in pressure drop across glass HEPA filters has been measured as a function of particle mass loading using polystyrene latex particles (PSL). PSL particles in several different sizes were generated as challenge aerosols. For each particle size distribution, the specific resistance (K2) was calculated by measuring the mass of PSL particles loaded per unit area of filter and the pressure drop across the filters at a given filtration velocity. In all cases, the specific resistance of the filter cake increased as the aerodynamic mean particle diameter decreased at the same mass loading. This correlation equation was modified by using the lognormal conversion method suggested by Raabe [1971] for a polydisperse particle size distribution; then the modified equation was expressed as a function of geometric mean particle diameter and standard deviation which could be obtained by the measuring instruments (PDS 3603; TSI Inc.). The advantage of this approach over other methods is the use of a more convenient prediction of pressure drop, if we know the geometric mean particle diameter and standard deviation, which could be easily measured. The values of porosities, obtained from the pressure drop responses of loading in the filters using the Rundnick and First equation, were compared with other researches.  相似文献   

8.
《分离科学与技术》2012,47(7):1771-1784
Abstract

The paper reviews the effect of particle size distribution and pore size distribution on granular bed filter and crossflow microfiltration performance. The experimental results of the granular bed filter with pollen particles in suspension showed that the presence of large particles improved the filter efficiency of smaller particles in suspension. Microfiltration results with bi and tri‐modal latex suspensions showed that the permeate flux and the quality were significantly affected by the particle size and its distribution, especially when the particle size was smaller than the pore size of the membrane. The mathematical model simulation results of granular bed filtration show that media pore size distribution is an important parameter of filtration for the particle removal and pressure drop across the filter.  相似文献   

9.
大部分纤维捕集效率和压降的理论模型认为纤维性能仅取决于来流速度、颗粒粒径、纤维体积分数、过滤层厚度、纤维直径等因素。实际上,布袋除尘器的性能还与纤维配置方式直接相关。利用LB(lattice Boltzmann)两相流模型对多层纤维捕集颗粒物过程进行了数值模拟,研究了不同纤维配置方式下系统压降与捕集效率的变化。结果表明,错列纤维的性能参数优于并列纤维;纤维排列间距增大,压降增幅大于捕集效率,导致性能参数下降。通过比较不同位置纤维的捕集能力发现,在布朗扩散和拦截捕集机制主导下,前方纤维捕集能力略强于后方纤维;而在惯性碰撞捕集机制主导时,对捕集贡献最大的主要是前两排纤维,后方纤维对捕集效率的贡献非常小,可以忽略。这些研究结果可以对布袋除尘器的多层纤维配置方式的优化提供理论依据和工程建议。  相似文献   

10.
《分离科学与技术》2012,47(8):1955-1973
Abstract

Coalescing filters are widely used throughout industry for removal of liquid aerosols from gases or the separation of liquid droplets from emulsions. Typical filters are constructed of non-woven fibers. Fibrous filters are capable of efficient removal of micron and submicron sized droplets and particles. The filtration process is highly complex due to variability in fiber sizes, particle sizes, mixtures of particles and droplets, mixture of types of droplets (oil, water, etc.), and effects of viscosity, surface tension, and chemical reactions between components or with the filter fibers. Prediction of filter performance under such complex conditions is difficult.

Performance of a filter depends on many factors like particle and fiber sizes, flow rate, surface properties of the fibers etc. One of those parameters is the saturation of the filter medium. Saturation is a measure of the amount of liquid present in the void space. Prior models assume that the saturation is uniform along the depth of the medium. In real media, the liquid holdup at steady state need not be uniform with position. Local velocity increases when the saturation is high.

In this paper, a steady state model for a coalescing filter is used to evaluate the effects of saturation on void fraction and its subsequent effect on filter performance. Single fiber mechanisms of direct interception and diffusion deposition are used to model droplet capture efficiencies and drag forces. These mechanisms are applied to volume averaged continuum equations in which the saturation is varied linearly with position in the filter. The results show the minimum pressure drop and largest quality factor occurs with a uniform saturation profile and that variation in average saturation has a greater effect on filter performance than does the slope of the linear saturation profile. The model predicts that uniform saturation profile performs better than the other profiles.  相似文献   

11.
The performance of filters made of sintered submicron alumina particles was evaluated. The filter has a high collection efficiency and high pressure drop, requiring the development of a special measuring system for its evaluation. The system consists of a polydisperse NaCl particle generator, a differential mobility analyzer (DMA), an ejector to supply aerosols for testing filters with high pressure drop, and a mixing-type condensation nucleus counter (CNC) capable of obtaining a stable reading of very low concentration particles. Penetrations as low as 10−9 can be measured in the particle diameter range of 0.02-0.14 μm. Two filters made by sintering 0.60 and 0.84 μm alumina particles were evaluated. The experimental data collected served as the basis of theoretical development. Following the single fibre theory, the filter penetration is calculated by using a single sphere as the element. Both the diffusion and interception collection mechanisms were taken into account. The resulting equation gives a general trend of efficiency curves as a function of the parameters involved, e.g. the test aerosol size, packed particle size and filtration velocity. However, it is not sufficiently accurate for providing quantitative performance results.  相似文献   

12.
Full 3D particle filtration modeling at low pressures considering slip/transition/free molecular flow regime, particle–fiber interactions, air/particle slip, sieve and homogenous flow field has been performed for the polyurethane nanofiber filter prepared by electrospinning process and the obtained theoretical predictions for the filtration efficiency have been compared with the corresponding experimental data. Moreover, the effect of air velocity, viscosity, temperature, pressure and particle–fiber friction coefficient on the produced polyurethane nanofiber filter efficiency has been investigated in more details. In order to take all real structure features of the nanofiber filter into account (such as varying fiber diameter, curvature along its length, inhomogeneity and mat defects), a new approach for 3D nanofiber mat model construction from corresponding SEM images has been proposed and utilized.  相似文献   

13.
This work is conducted to better our understanding of the influence of fibers’ in-plane and through-plane orientations on pressure drop and collection efficiency of fibrous media. The Stokes flow equations are numerically solved in virtual, 3-D, fibrous geometries with varying in-plane and/or through-plane orientations. Pressure drop and aerosol collection efficiency characteristics of such media are calculated and compared with available studies from the literature. Our results indicate that pressure drop and submicron particle capture efficiency of common fibrous filters with a fiber diameter of about 10 μm are independent of the in-plane orientation of the fibers, but decrease with increasing the fibers’ through-plane orientation. More interestingly, it was found that filters with higher through-plane fiber orientations have a higher figure of merit if challenged with nanoparticles. The figure of merit of these media, however, decreases as the particle size increases, reversing the effect of fibers’ through-plane orientation. It was also shown that when the diameter of the particles is comparable to that of the fibers, collection efficiency increases with decreasing the fibers’ in-plane orientation, while the pressure drop remains almost unchanged. This indicates that decreasing the fibers’ in-plane orientation increased the figure of merit of media made of nanofibers.  相似文献   

14.
An extensive experimental campaign has been carried out in a hot gas filtration test facility so as to test several filtering elements and configurations, particularly, three different types of bag filters and one ceramic candle. The facility was designed to operate under a wide range of conditions, thus providing an excellent tool for the investigation of hot gas filtration applications for the advanced electrical power generation industry such as IGCC, PFBC or fuel cell technologies.Relevant parameters for the characterisation and optimization of the performance of the filters have been studied for a variety of operating conditions such as filtration velocity, particle concentration, pressure and temperature among others. Pressure drop across the filter, cleaning pulse interval, baseline pressure drop, filtration efficiency and durability of the filter have been investigated for each type considered and dependences on parameters have been established. On top of that, optimal operating conditions and cleaning strategies were determined.The tests results show that bag filters are a suitable alternative for the hot gas filtration due to the better performance and the high efficiency observed, which makes them suitable for industrial applications operating under high temperature high pressure conditions considered within the study (200-370 °C and 4-7.5 barg, respectively).  相似文献   

15.
Depth filter media are usually composed of multiple layers to attain optimal values of main filtration parameters such as pressure drop and particle collection efficiency (PCE). Understanding the performance of the single layers that make up the filter media can contribute to attaining these optimum values. For the purpose of this study, we have developed two samples of depth filter media, 2LM and 3LM, composed of two and three layers, respectively. Samples of the media and single layers have been prepared in flat sheet form. Filtration performance of these samples has been evaluated using a lab-scale flat sheet filter media test unit with KCl as the test aerosol. Results from these tests have been compared with those from an automated filter tester (AFT) with NaCl as the test aerosol. These media have been characterized based on filter media properties and data from the filtration performance tests and the effect of layers on filtration performance has been observed. Pressure drop data from the tests with a standard test unit and our laboratory test unit are similar, and the difference in data is attributed to high inlet concentration of KCl particles. The overall filtration performance is strongly dependent on the final layer regarding pressure drop and particle of two- and three-layer filter media. Other constituent layers can be seen as contributors to the dust-holding capacity of the filter media and can reduce the dust load for the final layer.

Copyright 2013 American Association for Aerosol Research  相似文献   

16.
Electret filters are composed of thin, electrically charged fibers that are often utilized in industrial fields that require high collection efficiency with low flow resistance. A bundle-type electret filter in the Mechanical Ventilation and Air-Conditioning (MVAC) system of a Metro-subway was characterized in this study. The particle penetration and pressure drop parameters were examined under a filtration velocity ranging from 0.5 to 2.5 m/s. Particle penetration increased significantly in the early stages of filtration, but then became steady. The filter quality, which is a useful index of the filtration performance incorporating pressure drop and filtration efficiency, was evaluated for the test filters. The fiber bundle filter demonstrated a higher filter quality than the mechanical filter or the general panel-type electret filter with a small drop in pressure even at a high filtration velocity. In addition, the three dimensional structure and high electrostatic charge of the fiber bundle filter would enable a long retention time and constant level of pressure drop throughout the filtration.  相似文献   

17.
Various fibrous filter media, including surface filter media, depth filter media, woven and nonwoven filter media, were tested and particle loading capacity was calculated using bench‐scale setup via a new estimation approach which was proposed and experimentally verified with Novick‐Kozeny model. Multi‐element structured arrays (MESAs) developed by our research group were evaluated as well for particle loading capacity and filter lifetime on 24″ × 24″ full scale test rig (based on ASHRAE 52.2 Standard). Effects of varying filter media type, filter depth, pleat count and MESAs' element count on salt particle loading performance were experimentally investigated. The experimental studies showed that nonwoven activated carbon fiber filter media have allowed significantly higher salt particle loading capacity and longer useful lifetime compared to woven or nanofiber entrapped media. Furthermore, MESAs were able to significantly enhance loading capacity for salt particles and useful lifetime due to higher filtration area and lower filtration velocity. © 2016 American Institute of Chemical Engineers AIChE J, 62: 3739–3750, 2016  相似文献   

18.
The purpose of this study was to investigate the filtration and loading characteristics of granular bed filters. Stainless steel holders (diameter 71.6 mm, height 70 mm) were fabricated to accommodate 500 g of zirconium oxide (ZrO2) beads, as the packed media of granular bed. Monodisperse ZrO2 granules (0.3, 0.8, 2 and 4 mm in diameter) were used to demonstrate the effect of the granule size and packing geometry on both pressure drop and aerosol penetration. From the filter quality perspective, the selection of the ‘best” filter is complicated. Assuming a low face velocity (e.g., 0.58 cm/s), large granule size is more cost-effective because of the higher filter quality factor. The phenomenon implies that the gain in filtration efficiency due to larger surface area (of small granules in the filter) did not compensate for the increase in air resistance. After the cake formation point, the dust cake on glass fiber filter became compressed. This dust cake compaction caused the pressure to drop precipitously and intermittently. In contrast, the rate of increase in pressure drop of the dust cake formed on the granular bed filters decreased with time probably due to the pinhole channels in the increasing mass load. The size and density of the pinholes are determined by the granule size, the face velocity and the size of the challenge aerosols.  相似文献   

19.
采用数值方法求解绕方形截面纤维流场,考虑粒子布朗扩散、拦截效应和惯性碰撞捕集机理的联合作用,用布朗动力学方法研究方形截面纤维的过滤性能,考察了纤维迎风角(θ)、填充率(C)和过滤风速(u?)对捕集效率、质量因子及粒子沉积分布的影响。结果表明,小粒子的扩散捕集或大粒子的惯性捕集在方形纤维表面的粒子沉积行为均表现出显著的局部沉积特征,且与粒子捕集机理和迎风角有关。方形纤维质量因子的分析结果表明,在高填充率下,方形纤维的过滤压降虽高于圆截面纤维,但具有较高的捕集效率,综合过滤性能仍明显优于圆截面纤维,但在低填充率下,方形纤维综合过滤性能劣于圆截面纤维。  相似文献   

20.
Fibrous filters are highly efficient in removing micrometer particles, but their performance in the nanometer particle range is still little known. The aim of this study was to evaluate pressure drop and collection efficiency during nanoparticles cake formation using commercial fibrous filters. The filter media used were High Efficiency Particulate Air (HEPA) and polyester filters. The aerosols were generated by a commercial inhaler using a 5 g/L solution of NaCl and the particles produced were in the size range from 6 to 800 nm, with a peak at around 40 nm. A superficial velocity (vs) of 0.06 m/s was employed. During the filtration, the maximum pressure drop established was ?P = ?Pf +980Pa, where ?Pf is the initial pressure drop of the filter. The collection efficiency was determined for a clean filter and for intermediate pressure drops. The filtration curves obtained showed that the HEPA filter provided greater surface filtration, compared to the polyester filter. Comparison of the collection efficiencies for clean filters revealed that the HEPA filter was highly efficient, even in the absence of cake, while the polyester filter showed initial collection efficiencies of between 20 and 40% for particles in the size range from 100 nm to 1000 nm. However, after formation of the filter cake, the collection efficiencies of both filters were almost 100% during the final stage of filtration. This shows that the fibrous filter can be applied in several industrial processes with highly efficient nanoparticle separation, after the formation of a thin layer cake filtration.  相似文献   