首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Anionic surfactant (sodium oleate, SO) was used to pretreat polypropylene fibrous filters to make them negatively charged. This work examines the effects on particle loading of an anionic surfactant-pretreated filter. Also, the effects of various factors, such as the particle size, the face velocity, concentration of the surfactant, and particle distribution (mono and poly) on the particle loading characteristics were evaluated.Experimental data reveal that the electric field of a filter treated with anionic surfactant (SO) could be directly measured using an electrofieldmeter, suggesting that the pretreatment with surfactant charged the filters. The results demonstrate that pretreating the filter with SO surfactant increases its particle-loading capacity. The clogging points of the untreated filter, and of the 0.01, 0.05 and 0.08 M SO-pretreated filter are 18, 23, 28 and 33 g/m2. The loading behavior of the SO-pretreated filter depended on the size of the particles and the operating face velocity. Additionally, the loading behavior of the SO-pretreated filter with polydisperse particles is much the same as that with monodisperse particles. However, the clogging point of the SO-pretreated filter with polydisperse particles is higher than that with monodisperse equal size.  相似文献   

2.

In this work, three types of needlefelt filters, made of Polyester (PE), Ryton Sulfar (RS), and Polyaramid (PA), were tested to in- vestigate the aerosol loading characteristics of fabric filters when challenged with micrometer-sized monodisperse potassium sodium tartrate (PST) particles. A fibrous filter with packing density of 9%, thickness of 0.38 mm, and fiber diameter of 5.1 θ m was included for comparison. A vibrating orifice monodisperse aerosol generator was used to produce three different sizes (5, 10, and 20 θ m) of PST particles for aerosol loading experiment. An ultrasonic atomizing nozzle and a TSI constant output nebulizer were used to generate polydisperse PST particles for the aerosol penetration test. The aerosol penetration of submicrometer-sized particles through the filters was measured by using a Scanning Mobility Particle Sizer. An Aerodynamic Particle Sizer was used to measure the penetration fraction of aerosol particles larger than 0.8 θ m. The pressure drop across the filter was monitored by using pressure transducers, which were calibrated against an inclined manometer. Airflows of 5, 10 , 20, and 30 cm/s were used to study the flow dependency. The aerosol penetration results showed that the particles larger than 3 θ m did not penetrate the clean fabric filters tested in the present study. The loading curves (plots of pressure drop against sampling time) displayed three regions: an initial region of fast increase, a transition region, and a final linear region after the dust formation point. After the formation point of the dust cake, both fabric and fibrous filters shared the same slope (of the loading curves). The slope of different regions of the loading curves was determined by many factors, such as size of challenge aerosol, face found to be critical to the performance of the fabric filters. In order lower porosity, which caused an extra rise in pressure drop across velocity, surface treatment, and the compressibility of the dust cake forming on the filter. The method of final surface treatment was to avoid the unnecessary rise in air resistance, the melting clumps formed during final surface treatment should be as thin and narrow as possible, just enough to support the filter bag cleaning. From the standpoint of filter quality and energy consumption, the low filtration velocity has to be adopted whenever possible, because high filtration velocity not only led to lower filter quality (in particular for submicrometer-sized particles) but also created dust cake of lower porosity, which caused an extra rise in pressure drop across thet dust cake.  相似文献   

3.
Particle deposition onto a filter fiber was numerically simulated when a uniform external electric field was applied. The effects of electric field strength, particle inertia, and electrical conductivity of particles on particle deposition characteristics such as particle loading patterns and collection efficiency were qualitatively investigated. As a result, the electrostatic forces between a newly introduced particle and the already captured particles on the fiber were found to have a great influence on the particle deposition patterns compared with the results where the electrostatic forces were neglected. Conductive particles and filter fibers lead to higher collection efficiency and more linear structure of particle deposits than those of dielectrics, and the particle inertia could also be more important to the collection efficiency of a fibrous filter when electric fields are present. The simulated particle deposits obtained from this work agreed well with the existing experimental results, in which the photographs of particle loaded fibers, within an external electric field, were reported.  相似文献   

4.
The performance of electrostatically charged blown microfiber filter media was characterized for high-volume sampling applications. Pressure drop and aerosol collection efficiency were measured at air pressures of 55.2 and 88.7 kilopascals (kPa) and filter face velocities ranging from 2.5 to 11.25 meters per second (m/s). Particle penetration was significant for particles above 0.5 micrometers (μm) in aerodynamic diameter where the onset of particle rebound was observed as low as 200 nanometers (nm). Particle retention was enhanced by treating filters in an aqueous solution of glycerol. Adding this retention agent eliminated electrostatic capture mechanisms but mitigated inertial rebound. Untreated filters had higher nanoparticle collection efficiencies at lower filter face velocities where electrostatic capture was still significant. At higher filter face velocities, nanoparticle collection efficiencies were higher for treated filters where inertial capture was dominant and particle rebound was mitigated. Significant improvements to microparticle collection efficiency were observed for treated filters at all air flow conditions. At high air pressure, filter efficiency was greater than 95% for particles less than 5 μm. At low air pressure, performance enhancements were not as significant since air velocities were significantly higher through the fiber mat. Measured single fiber efficiencies were normalized by the theoretical single fiber efficiency to calculate adhesion probability. The small fiber diameter (1.77 μm) of this particular filter gave large Stokes numbers and interception parameters forcing the single fiber efficiency to its maximum theoretical value. The adhesion probability was plotted as a function of the ratio of Stokes and interception parameter similar to the works of others. Single fiber efficiencies for inertial nanoparticle collection were compared to existing theories and correlations.

Copyright 2014 American Association for Aerosol Research  相似文献   


5.
Aerosol collection efficiency was studied for electrostatically charged fibrous filters (3M Filtrete?, BMF-20F). In this study, collection efficiencies at moderate filter face velocities (0.5–2.5 m/s) representative of some high volume sampling applications was characterized. Experimental data and analytical theories of filter performance are less common in this flow regime since the viscous flow field assumption may not be representative of actual flow through the filter mat. Additionally, electrostatic fiber charge density is difficult to quantify, and measurements of aerosol collection efficiency are often used to calculate this fundamental parameter. The purpose of this study was to assess the relative influence of diffusion, inertial impaction, interception, and electrostatic filtration on overall filter performance. The effects of fiber charge density were quantified by comparing efficiency data for charged and uncharged filter media, where an isopropanol bath was used to eliminate electrostatic charge. The effects of particle charge were also quantified by test aerosols brought into the equilibrium Boltzmann charge distribution, and then using an electrostatic precipitator to separate out only those test particles with a charge of zero. Electrostatically charged filter media had collection efficiencies as high as 70–85% at 30 nm. Filter performance was reduced significantly (40–50% collection efficiency) when the electrostatic filtration component was eliminated. Experiments performed with zero charged NaCl particles showed that a significant increase in filter performance is attributable to an induction effect, where electrostatic fiber charge polarizes aerosol particles without charge. As filter face velocity increased the electrostatic filtration efficiency decreased since aerosol particles had less time to drift toward electrostatically charged fibers. Finally, experimental data at 0.5 m/s were compared to theoretical predictions and good agreement was found for both electrostatic and nonelectrostatic effects.

© 2013 American Association for Aerosol Research  相似文献   

6.
Three different respirator filter media (two electrets and one fiberglass) were challenged with monodisperse multi-walled carbon nanotubes (MWCNTs) of mobility diameters 20–500 nm at 5.3 and 10.6 cm s?1 face velocities. The penetration data were compared with that of sphere-like NaCl particles. The MWCNT penetrations were generally lower than those of NaCl at both face velocities in all three filters. However, the MWCNTs had a slightly higher penetration than the NaCl in the fiberglass filter at 10.6 cm s?1 face velocity when their mobility diameters were lower than 50 nm and the alignment effect was expected to occur. Results from the scanning electron microscopic (SEM) analysis supported the hypothesis of the alignment effect, which showed that the MWCNTs tend to be straighter or with higher aspect-ratios at the mobility sizes less than 100 nm, leading them more readily to align with the flow. Therefore, caution should be exercised when respirators are used against the MWCNTs with the mobility diameters less than 100 nm. The single fiber theory predicted the penetration of both particles in the fiberglass filters well for the particles with below 100 nm mobility diameters but discrepancies occurred beyond 100 nm. The theory still predicted the NaCl penetration through the electret filters well for the sizes below 100 nm but only predicted the MWCNT penetration well for ~20–30 nm. The Nuclepore filter and the corresponding capillary tube model were adopted to study the mechanical deposition mechanisms of MWCNTs. The model was found to predict MWCNT penetration very well when the effective length of the MWCNT was taken into account.

Copyright 2014 American Association for Aerosol Research  相似文献   

7.
This investigation experimentally explores the penetration curve of particles shot onto a stainless steel fibrous filter or a flat surface. The effect of the pore size of the stainless steel fibrous filter, with or without an oil coating, on the particle penetration was examined at various flow rates, nozzle diameters and dimensionless particle diameters, Sqrt(Stk). The penetration of the flat surface by particles was also determined for comparison. Experimental results demonstrate that oleic acid particles larger than Sqrt(Stk)50 are collected on the stainless steel fibrous filter with a low penetration, while smaller particles stay in the particle-laden stream with high penetration. The penetration of potassium chloride particles exceeds that of oleic acid particles, because potassium chloride particles bounce off the stainless steel fibrous filter and the flat surface. Particles bounce off the metal filter less easily than the flat surface. Coating the stainless steel fibrous filter with oil effectively reduces problems of particle bounce. The potassium chloride particles sucked the coated oil forming a small mountain on the surface. When the loaded particle mass on the coated stainless steel fibrous filter ranges between 0.4 and 2.3 mg, Sqrt(Stk)50 is a constant 0.35.  相似文献   

8.
The objective of this study is to analyze the removal characteristics and distribution of indoor air pollutants by a room air cleaner. A pollutant removal effect according to room volume and measurement point was evaluated in an indoor room. A series of filtration efficiency tests were performed on only the electrostatic precipitator of the room air cleaner. The measurements of filter efficiency and pressure drop across the electrostatic precipitator were made using an ASHRAE 52.1-1992 filter test system and an opacity meter to measure the particle concentration upstream and downstream of the test filter. Also the performance of the air cleaner in the room was evaluated by examining tobacco smoke particle concentration. The size distribution of the tobacco smoke particles was 1.27 μm in mass median diameter and a geometric standard deviation of 1.313 μm. The efficiency of the electrostatic filter was measured as 78.6% with dust particles of 1.96 μm in mass median diameter and 1.5m/s face velocity. The tobacco smoke particle concentration as a function of time decayed exponentially. The contaminant removal effect was increased when increasing the effective clean air exchange rate (ηQ/V), which is 0.0780 min?1 for 51 m3 room and 0.0235 min?1 for 149 m3 room. This study clearly shows that a room air cleaner with an electrostatic precipitator is effective in removing tobacco smoke particles. The removal characteristics and distribution of indoor air pollutants in other rooms is predicted based on empirical modeling.  相似文献   

9.
Various fibrous filter media, including surface filter media, depth filter media, woven and nonwoven filter media, were tested and particle loading capacity was calculated using bench‐scale setup via a new estimation approach which was proposed and experimentally verified with Novick‐Kozeny model. Multi‐element structured arrays (MESAs) developed by our research group were evaluated as well for particle loading capacity and filter lifetime on 24″ × 24″ full scale test rig (based on ASHRAE 52.2 Standard). Effects of varying filter media type, filter depth, pleat count and MESAs' element count on salt particle loading performance were experimentally investigated. The experimental studies showed that nonwoven activated carbon fiber filter media have allowed significantly higher salt particle loading capacity and longer useful lifetime compared to woven or nanofiber entrapped media. Furthermore, MESAs were able to significantly enhance loading capacity for salt particles and useful lifetime due to higher filtration area and lower filtration velocity. © 2016 American Institute of Chemical Engineers AIChE J, 62: 3739–3750, 2016  相似文献   

10.
Experiments were made to determine the lowest absolute levels of particle concentrations achievable by filtration. Two commercially available PVDF membrane filters were evaluated, namely, a 25-cm pleated filter cartridge (Milli-pore Durapore-TP 1 1Liquid Air is a member of the L'Air Liquide Group. View all notes) and a smaller point-of-use filter with integrated housing (Millipore Wafergard In-Line 2 2Durapore-TP and Wafergard In-Line are trade marks of Millipore Corp. View all notes). These filters have established penetration probabilities of less than 3 × 10?9. Tests were performed at steady flow rates up to 1.4 Nm3/min and 0.1 Nm3/min, respectively. Data were taken with a condensation nuclei counter and two laser particle spectrometers. Measurements covering the size range from about 0.01 to 3 μm show that average concentrations of less than three particles/m3 (ca. 0.1 particle/ft3) can be attained continuously. Twenty-four hour periods without detection of a single particle are not uncommon. At these levels, the limiting factor is the cleanliness of all surfaces on the downstream side of the filter, and not filter efficiency in the traditional sense.  相似文献   

11.
The flat surface of Nuclepore filters is suitable for observing collected particles with a scanning electron microscope (SEM). However, experimental data on surface-collection efficiency are limited because surface-collection efficiencies cannot be measured directly using aerosol measuring instruments. In this study, the surface-collection efficiencies of Nuclepore filters were determined by establishing the ratio of the number of particles deposited on the surface of the filter visually counted with an SEM to the number of inflow particles counted by a condensation particle counter, using monodispersed polystyrene latex particles (30–800 nm) and silver particles (15–30 nm). Because Nuclepore filters with smaller pore sizes would be expected to produce higher minimum surface-collection efficiency and a higher pressure-drop, 0.08 and 0.2 µm Nuclepore filters were chosen as the test filters in view of both collection efficiency and pressure drop. The results showed that the minimum surface-collection efficiencies of the 0.08 µm pores at face velocities of 1.9 and 8.4 cm·s?1 were approximately 0.6 and 0.7, respectively, and those of the 0.2 µm pores at face velocities of 1.5 and 8.6 cm·s?1 were approximately 0.8 and 0.6, respectively. Because the pressure drop of the 0.2 µm pore filter was lower than that of the 0.08 µm pore filter under the same flow-rate conditions, the 0.2 µm pore filter would be more suitable considering the pressure drop and collection efficiency. The obtained surface collection efficiencies were quantitatively inconsistent with theoretical surface-collection efficiencies calculated using conventional theoretical models developed to determine the collection efficiency of filters with larger pores.

© 2016 American Association for Aerosol Research  相似文献   

12.
Near traffic routes and urban areas, the outdoor air particle number concentration is typically dominated by ultrafine particles. These particles can enter into the nearby buildings affecting the human exposure on ultrafine particles indoors. In this study, we demonstrate an aerosol generation system which mimics the characteristic traffic related aerosol. The aerosol generation system was used to determine the size-resolved particle filtration efficiencies of five typical commercial filters in the particle diameter range of 1.3–240 nm. Two different HEPA filters were observed to be efficient in all particle sizes. A fibrous filter (F7) was efficient at small particle sizes representing the nucleation mode of traffic related aerosol, but its efficiency decreased down to 60% with the increasing particle size. In contrast, the filtration efficiency of an electrostatic precipitator (ESP) increased as a function of the particle size, being more efficient for the soot mode of traffic related aerosol than for the nucleation mode. An electret filter with a charger was relatively efficient (filtration efficiency >85%) at all the observed particle sizes. The HEPA, F7 and electret filters were found to practically remove the particles/nanoclusters smaller than 3 nm. All in all, the filtration efficiencies were observed to be strongly dependent on the particle size and significant differences were found between different filters. Based on these results, we suggest that the particulate filter test standards should be extended to cover the ultrafine particles, which dominate the particle concentrations in outdoor air and are hazardous for public health.

Copyright © 2017 American Association for Aerosol Research  相似文献   


13.

In this study, we developed a simulation method to predict the initial collection efficiency of a unipolar charged fiber and the particle deposition morphology in the electret filter composed of unipolar charged fibers. The particle sizes considered in this study were in the submicron range, and in the simulation method, Brownian motion of particles was also taken into consideration along with electrostatic forces acting on the particles. The simulation results were compared with other investigator's initial collection efficiency data, and it was found that simulation results are in good agreement with the experimental data. Based on this, we analyzed the effect of operating variables on the particle deposition morphology, which in turn affects the collection efficiency and pressure drop of the filter. In view of the simulation results on particle deposition morphology, it is clear that in the case of electret filters, particle deposition tends to take place onto the entire perimeter of fibers relatively uniformly, which may reduce the increase of pressure drop with time or extent of particle deposition compared to the conventional fibrous filter.  相似文献   

14.
A laboratory scale test system has been designed and constructed to study the electrical agglomeration of charged aerosol particles as a method to increase the fine particle collection efficiency of electrostatic precipitators. The system consists of test aerosol generator, aerosol charger, agglomerator chambers, and aerosol measurement equipment. Air atomizing nozzles and the TSI six-jet atomizer have been used as the test particle generators. The test particles have been charged by a corona discharge. Two types of agglomerator chambers have been investigated. In one agglomerator the gas flows between two parallel plates, across which the alternating high voltage is applied. The other agglomerator is a quadrupole structure with cylindrical electrodes positioned between the grounded plates. Particle concentration and size distribution measurements have been carried out downstream of the agglomerator with agglomerator voltage on and off. Particle concentrations and size distributions have been measured with differential mobility analyzer (DMA) and a Berner low pressure impactor. These measurements show that agglomeration causes about a 4%-8% decrease in the fine particle concentration when the total mass concentration is between 1 and 2 g/m3. There was no difference between the results measured with the parallel plate and the quadrupole agglomerator.  相似文献   

15.
The respective contributions of direct particle penetration vs. particle reentrainment to emissions of pulse-jet cleaned filter media were measured for needle felts of different construction, in combination with two particle materials, one free-flowing and one agglomerating. Different media conditioning protocols (including accelerated aging up to 20,000 pulses) were applied as well, in order to simulate longer-term use of the filters.With about 96-99% of emissions per cycle, direct particle penetration was by far the dominant mechanism under all circumstances. The size distribution of emitted particles was centred narrowly around the MPPS between 0.5 and 1 µm, and tended to shift toward finer particles with progressive media aging, much like in a depth filter. The total reentrained dust mass per cycle was on the order of 10− 5 of the mass stored inside the medium. Cross-sectional analysis of a few media by electron microprobe indicates that the support scrim may act as an effective barrier to particle seepage more than to direct penetration.The well known increase in emission level with cleaning pulse intensity can be attributed to a slowing-down or prevention of the clogging process, rather than enhanced reentrainment of stored dust. Earlier reports of increased emissions at higher filter face velocities are probably due to the redeposition of dust from the filter cake immediately after a cleaning pulse.  相似文献   

16.

Fibrous particles constitute an important class of aerosols that are potential human health hazards. Filters can remove aerosols from the air. The capture of spherical and fibrous aerosols by fibrous filters was investigated in this study. The governing equations of motions for translation and rotation of fibrous particles are derived for airflow over a cylindrical object. Only impaction and interception losses were considered in this study. Transport and deposition of fibrous particles were found to depend on Stokes number, fibrous particle aspect ratio, and ratio of the fibrous particle diameter to the diameter of fibrous filters. Using the Kuwabara flow field, transport and single-fibrous filter capturing efficiency of spherical and fibrous particles were calculated numerically, and these calculations were compared with available data in the literature. The calculated results compared favorably with the results of Yeh and Liu (1974) for spherical particles. Good agreement for losses by interception for both spherical and fibrous particles was observed between our results and those of Lee and Liu (1982). Further experimental data are needed to verify the predicted losses of fibrous aerosols by impaction.  相似文献   

17.
Simultaneous transmissivity and absorptivity measurements were carried out in the visible at a laser wavelength of 532?nm on drop-cast, carbon-black-laden filters under ambient (laboratory) conditions. The focus of this investigation was to establish the feasibility of this approach to estimate the mass absorption coefficient of the isolated particles and compare results to earlier work with the same carbon-black source. Transmissivity measurements were carried out with a laser probe beam positioned normal to the particle-laden filter surface. Absorptivity measurements were carried out using a laser-heating approach to record in time the sample temperature rise to steady-state and decay back to the ambient temperature. The sample temperature was recorded using a fine-wire thermocouple that was integrated into the transmission arrangement by placing the thermocouple flush with the filter back surface. The advantage of this approach is that the sample absorptivity can be determined directly (using laser heating) instead of resolving the difference between reflectivity (filter surface scattering) and transmissivity. The current approach also provides the filter optical characteristics, as well as an estimate of filter effects on the absorption coefficient due to particle absorption enhancement or shadowing. The approach may also be incorporated into other filter-based techniques, like the particle/soot absorption photometer, with the simple addition of a thermocouple to the commercial instrument. For this investigation, measurements were carried out with several blank uncoated quartz filters. A range of solution concentrations was prepared with a well-characterized carbon black in deionized water (i.e., a water-soluble carbonaceous material referred to as a surrogate black carbon or ‘carbon black’). The solution was then drop cast using a calibrated syringe onto blank filters to vary particle loading. After evaporation of the water, the measurements were repeated with the coated filters. The measurement repeatability (95% confidence level) was better than 0.3?K for temperature and 3?×?10?5 mW for laser power. From the measurements with both the blank and coated filters, the absorption coefficient was determined for the isolated particles. The results were then compared with an earlier investigation by You et al. and Zangmeister and Radney, who used the same carbon-black material. The measurements were also compared with Lorenz–Mie computations for a polydispersion of spherical particles dispersed throughout a volume representative of the actual particles. The mass absorption coefficient for the polydispersion of carbon-black particles was estimated to be about 7.7?±?1.4?m2 g?1, which was consistent with the results expected for these carbon black particles.  相似文献   

18.
The article presents experimental results and theoretical analysis of aerosol nanoparticle penetration through fibrous filters with a broad fiber diameter distribution. Four fibrous filters were produced using the melt-blown technique. The analysis of the filters’ SEM images indicated that they had log-normal fiber diameter distribution. Five kinds of proteins and two types of silica particles were generated by electrospraying and were then classified using a Parallel Differential Mobility Analyzer to obtain well-defined, monodisperse, singly charged challenge aerosols with diameters ranging from 6.3 to 27.2 nm. Particle penetration through the filters was determined using a water-based CPC. Experimental results were compared first with predictions derived from the classical theory of aerosol filtration. It is demonstrated that it is inappropriate to apply it to the arithmetic mean fiber diameter, as this results in turn in a huge underestimation of nanoparticle penetration. A better, but still unsatisfactory agreement is observed when that theory was used together with the pressure drop equivalent fiber diameter or when the Kirsch model of nonuniform fibrous media was applied. We show that the classical theory applied to any fixed fiber diameter predicts a stronger dependence of nanoparticle penetration on the Peclet number as compared to experimental data. All these observations were successfully explained by using our original partially segregated flow model that accounts for the filter fiber diameter distribution. It was found that the parameter of aerosol segregation intensity inside inhomogeneous filters increases with the increase in particle size, when the convective transport becomes more pronounced in comparison to the diffusive one.  相似文献   

19.
Two natural products; i.e., grapefruit seed extract (GSE) and propolis, were investigated for use in antimicrobial air filters. Staphylococcus aureus was investigated as a test bioaerosol, and was deposited on the antimicrobial filters, which were treated by spraying with various areal densities of GSE and propolis. The pressure drop and particle penetration were investigated to assess the filtration performance of the bioaerosol, and the bacterial-inactivation performance of the filters was evaluated by quantifying S. aureus. There was little change in the pressure drop as a function of the areal density of GSE up to 185.9 μg/cm2; however, a significant change in the pressure drop was found for the air filter coated with propolis at an areal density of 98.4 μg/cm2. The penetration levels of bioaerosols in both filters were uniform and in the range 1.4–2.0% (based on particle number), regardless of the areal density of the deposited GSE or propolis. The inactivation rates of the filters with identical deposition masses of GSE and propolis were similar in the ranges of 92.1–100%, 75.2–89.1%, and 54.4–75.5% at the control filters with colony numbers of 103, 104, and 105 CFU/mL, respectively. The bacterial inactivation rate could be described by an exponential function of the areal density of GSE/propolis per number of colonies.

Copyright 2015 American Association for Aerosol Research  相似文献   

20.
Understanding the filtration characteristics of fibrous particles is important since those particles have caused health and environmental concerns. Due to the straight morphology of metal nanowires, unlike carbon nanotube (CNT) particles nanowires can be considered as appropriate test material to evaluate existing filtration theory for cylindrical particles. We measured the penetration of silver nanowires in the size range of dm = 200 to 400 nm through screen mesh filter. By using Li et al. (2012)'s theory, we determined the orientation status of silver nanowires inside differential mobility analyzer (DMA) and calculated the dynamic shape factor of nanowires. Theoretical penetration was obtained by using single fiber theory with modified interception parameter including orientation angle between a filter wire and a particle. The orientation angle obtained by fitting experimental data into single fiber theory for the 1 layer of screen mesh filter is found to be close to 40° indicating random orientation of nanowires near filter. However, in the experiments with multi-layers of screen mesh, any tendency related to the orientation angle was not found. We performed numerical simulations for the filtration processes such as impaction, diffusion, interception, and interception of diffusing particles by introducing modified slip correction factor. Overall, when interception of diffusing particles is considered in addition to diffusion and interception, numerically simulation results and theoretical prediction agree better with experimental data regarding the penetration of silver nanowires through the 1 layer of screen mesh filter.

Copyright 2014 American Association for Aerosol Research  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏