首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The relationship between the isotope fractionation of alkaline-earth elements in the surface ionization ion source and the evaporation filament current, i.e., filament temperature, was studied. It was confirmed that the isotope fractionation depends on the evaporation filament temperature; the isotope fractionation in the case of higher temperature of filament becomes larger. The ionization and evaporation process in the surface ionization ion source was discussed, and it was concluded that the isotope fractionation is suppressed by setting at the lower temperature of evaporation filament because the dissociations are inhibited on the evaporation filament.  相似文献   

2.
The experimental low energy plasma for hemispherical analyzers nominal testing thermal plasma facility of Dartmouth College uses a microwave plasma source which generates an ionosphere-like plasma through a two-step process. The plasma is initially generated inside a cylindrical, insulated, resonance cavity. This initial plasma must pass through a sheath in order to enter the main experimental region. This process imparts a significant flow velocity to the ions which has been neglected in previous analysis of this plasma source. We predict the flow energy of the ions to be between 12-15 eV depending on conservation laws and show agreement with experimental results.  相似文献   

3.
A tungsten filament cathode has been operated with an ac heating current to excite a plasma in a linear magnetic field. Both the discharge current and the ion saturation current in plasma near the extraction hole of the ion source exhibited fluctuations. The discharge current fluctuated with the amplitude less than 2% of the average, and the frequency two times the frequency of the heating current. Fluctuation amplitude of the ion saturation current was about 10% of the average, while the frequency was the same as that of the heating current. The ac operation has prolonged the lifetime of a hot filament cathode by about 50%.  相似文献   

4.
The rf source test facility SPIDER will test and optimize the source of the 1 MV neutral beam injection systems for ITER. Cavity ring-down spectroscopy (CRDS) will measure the absolute line-of-sight integrated density of negative (H(-) and D(-)) ions, produced in the extraction region of the source. CRDS takes advantage of the photodetachment process: negative ions are converted to neutral hydrogen atoms by electron stripping through absorption of a photon from a laser. The design of this diagnostic is presented with the corresponding simulation of the expected performance. A prototype operated without plasma has provided CRDS reference signals, design validation, and results concerning the signal-to-noise ratio.  相似文献   

5.
A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the resonance properties of the cavity. With plasma the frequency dependent behavior is strongly damped and this trend strengthens with increasing microwave power.  相似文献   

6.
Microwave plasma ion source with rectangular cavity resonator has been examined to improve ion beam current by changing wave launcher type from single-port to double-port. The cavity resonators with double-port and single-port wave launchers are designed to get resonance effect at TE-103 mode and TE-102 mode, respectively. In order to confirm that the cavities are acting as resonator, the microwave power for breakdown is measured and compared with the E-field strength estimated from the HFSS (High Frequency Structure Simulator) simulation. Langmuir probe measurements show that double-port cavity enhances central density of plasma ion source by modifying non-uniform plasma density profile of the single-port cavity. Correspondingly, beam current from the plasma ion source utilizing the double-port resonator is measured to be higher than that utilizing single-port resonator. Moreover, the enhancement in plasma density and ion beam current utilizing the double-port resonator is more pronounced as higher microwave power applied to the plasma ion source. Therefore, the rectangular cavity resonator utilizing the double-port is expected to enhance the performance of plasma ion source in terms of ion beam extraction.  相似文献   

7.
We have carried out a series of measurements demonstrating the feasibility of using the Dresden electron beam ion source (EBIS)-A, a table-top sized, permanent magnet technology based electron beam ion source, as a charge breeder. Low charged gold ions from an AuGe liquid metal alloy ion source were injected into the EBIS and re-extracted as highly charged ions, thereby producing charge states as high as Au(60 +). The setup, the charge breeding technique, breeding efficiencies as well as acceptance and emittance studies are presented.  相似文献   

8.
针对传统直流电晕放电离子迁移谱仪(CD-IMS)稳定性差、功耗高的不足,设计制备了针-针结构脉冲电晕放电电离源,并使用该电离源搭建了脉冲CD-IMS装置。研制的高压脉冲发生电路输出幅值和脉冲重复周期可调,体积小、功耗低。研究了放电稳定性并进行了实际样品测试,在无离子门的情况下得到了正、负离子模式反应离子峰谱图。该装置在正负模式下的分辨率分别为25.17(甲基磷酸二甲酯(DMMP)二聚体)和15.88(水杨酸甲酯)。  相似文献   

9.
The properties of a steady-state, dc discharge multidipole ion source have been investigated. The plasma density in the source depends on the magnet geometries, the discharge voltage, and the bias voltage on the first extraction grid. Different schemes to reduce the loss of ions to the chamber wall are described. Hydrogen ion species in the extracted beam are studied by a mass analyzer.  相似文献   

10.
A mechanism of ion extraction from a glow-discharge ion source based on a hollow cathode and used for elemental analysis of solids, is considered Experiments have shown that two oppositely directed ion flows are formed from ions produced in the region of negative glow-discharge fluorescence. One flow has an ion energy ≥ 100 eV, is directed to the cathode, and bombards and sputters the analyzed sample. The sputtered atoms diffuse into the negative-glow region and are ionized. The second flow (low-energy ions) is extracted from the same negative-glow region and transported from the cathode to the surface of the anode chamber owing to an ambipolar diffusion. These ions are extracted from a hole in the anode chamber of a standard ion source by an electric field and are used for mass-spectrum analysis. The energy-distribution width for these ions is ∼5 eV. The intensity of the ion beam extracted from the anode hole is an order of magnitude higher than the intensity of the ion beam extracted from the cathode region. Original Russian Text ? G.G. Sikharulidze, 2009, published in Pribory i Tekhnika Eksperimenta, 2009, No. 2, pp. 105–109.  相似文献   

11.
The resonance ionization laser ion source (RILIS) produces beams for the majority of experiments at the ISOLDE on-line isotope separator. A substantial improvement in RILIS performance has been achieved through a series of upgrade steps: replacement of the copper vapor lasers by a Nd:YAG laser; replacement of the old homemade dye lasers by new commercial dye lasers; installation of a complementary Ti:Sapphire laser system. The combined dye and Ti:Sapphire laser system with harmonics is capable of generating beams at any wavelength in the range of 210-950 nm. In total, isotopes of 31 different elements have been selectively laser-ionized and separated at ISOLDE, including recently developed beams of samarium, praseodymium, polonium, and astatine.  相似文献   

12.
At intensities of the order of 10(10) W∕cm(2), ns pulsed lasers can be employed to ablate solid bulk targets in order to produce high emission of ions at different charge state and kinetic energy. A special interest is devoted to the production of protons with controllable energy and current from a roto-translating target irradiated in repetition rate at 1-10 Hz by a Nd:Yag pulsed laser beam. Different hydrogenated targets based on polymers and hydrates were irradiated in high vacuum. Special nanostrucutres can be embedded in the polymers in order to modify the laser absorption properties and the amount of protons to be accelerated in the plasma. For example, carbon nanotubes may increase the laser absorption and the hydrogen absorption to generate high proton yields from the plasma. Metallic nanostrucutres may increase the electron density of the plasma and the kinetic energy of the accelerated protons. Ion collectors, ion energy analyzer, and mass spectrometers, used in time-of-flight configuration, were employed to characterize the ion beam properties. A comparison with traditional proton ion source is presented and discussed.  相似文献   

13.
Field ionization as a means to create ions for compact and rugged neutron sources is pursued. Arrays of carbon nano-fibers promise the high field-enhancement factors required for efficient field ionization. We report on the fabrication of arrays of field emitters with a density up to 10(6)?tips∕cm(2) and measure their performance characteristics using electron field emission. The critical issue of uniformity is discussed, as are efforts towards coating the nano-fibers to enhance their lifetime and surface properties.  相似文献   

14.
The development of new target ion source systems for the selective production of exotic species (SPES) facility is currently in progress at Legnaro National Laboratories. In this context, the study of ion sources and their performance in terms of ionization efficiency and transversal emittance is a crucial point in order to maximize the available yields, particularly for short-lived isotopes. In this work, preliminary off-line ionization efficiency and emittance measurements for the SPES surface and plasma ion sources are presented. The plasma source emittance measurements are supported by dedicated numerical calculations.  相似文献   

15.
Arc discharge of a hot cathode bucket ion source tends to be unstable what attributes to the filament self-heating and energetic electrons backstreaming from the accelerator. A regulation method, which based on the ion density measurement by a Langmuir probe, is employed for stable arc discharge operation and long pulse ion beam generation. Long pulse arc discharge of 100 s is obtained based on this regulation method of arc power. It establishes a foundation for the long pulse arc discharge of a megawatt ion source, which will be utilized a high power neutral beam injection device.  相似文献   

16.
Efficient trapping and detection of intact peptide ions is demonstrated in a quadrupole ion trap (QIT) coupled to an external vacuum matrix-assisted laser desorption ionization (MALDI) source. Deactivation of metastable ions generated by MALDI is achieved in a pressure transient environment inside the QIT established by pulsing gas to access the higher pressures required for fast thermalization, without affecting vacuum conditions in the ion source and time-of-flight (TOF) mass analyzer. Pressure transients are experimentally determined and a threshold of approximately 10 mTorr is identified where internally excited ions, which commonly observed to dissociate upon injection in a QIT, are stabilized. Fragment-free spectra are presented for a set of peptides by using 2,5-dihydroxybenzoic acid (DHB) as a matrix, and significantly reduced fragmentation is observed by using a-cyano-4-hydroxycinnamic acid (CHCA). Intact peptide spectra of a protein tryptic digest are also recorded with CHCA. The process of translational cooling for externally injected ions in a dynamic pressure environment is visualized by using ion trajectory simulations that employ hard sphere collisions. Statistical theory of dynamic equilibrium of ions stored in rf fields is applied to our QIT to characterize a translationally thermalized ion cloud, to explain observed ejection efficiency into the TOF mass analyzer, and to further discuss collisional deactivation of metastable ions.  相似文献   

17.
Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H(-) ion sources. In addition, it was found that the ratio of the electron density to the H(-) ion density dramatically decreases with increase of a bias voltage and the H(-) ions become dominant negative particles at the bias voltage of more than 6 V.  相似文献   

18.
A 60 kV ion source (9 beamlets of 15 mA each of H(-)) and plasma generators are being developed at Consorzio RFX and INFN-LNL, for their versatility in experimental campaigns and for training. Unlike most experimental sources, the design aimed at continuous operation. Magnetic configuration can achieve a minimum ∣B∣ trap, smoothly merged with the extraction filter. Modular design allows for quick substitution and upgrading of parts such as the extraction and postacceleration grids or the electrodes in contact with plasma. Experiments with a radio frequency plasma generator and Faraday cage inside the plasma are also described.  相似文献   

19.
Positive and negative secondary ion emission of 23 pure elements have been studied for 10 keV In+ and 10 keV O2+ bombardment. In+ ions were produced in a liquid metal ion source. For most of the elements investigated positive and negative secondary ion yields under In+ impact are comparable to those obtained with O2+ primary ions. Admission of oxygen into the sample chamber enhances positive and negative ion intensitities in a strongly element-specific manner. Depth profiles of a Ni/Cr multilayer (100 Å single-layer thickness) using 5 keV In+ primary ions show that these ions may also be applied successfully for secondary ion mass spectrometric depth profiling.  相似文献   

20.
One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号