首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 469 毫秒
1.
The development of new target ion source systems for the selective production of exotic species (SPES) facility is currently in progress at Legnaro National Laboratories. In this context, the study of ion sources and their performance in terms of ionization efficiency and transversal emittance is a crucial point in order to maximize the available yields, particularly for short-lived isotopes. In this work, preliminary off-line ionization efficiency and emittance measurements for the SPES surface and plasma ion sources are presented. The plasma source emittance measurements are supported by dedicated numerical calculations.  相似文献   

2.
Electrostatic beam optics for a multi-element focused ion beam (MEFIB) system comprising of a microwave multicusp plasma (ion) source is designed with the help of two widely known and commercially available beam simulation codes: AXCEL-INP and SIMION. The input parameters to the simulations are obtained from experiments carried out in the system. A single and a double Einzel lens system (ELS) with and without beam limiting apertures (S) have been investigated. For a 1 mm beam at the plasma electrode aperture, the rms emittance of the focused ion beam is found to reduce from ~0.9 mm mrad for single ELS to ~0.5 mm mrad for a double ELS, when S of 0.5 mm aperture size is employed. The emittance can be further improved to ~0.1 mm mrad by maintaining S at ground potential, leading to reduction in beam spot size (~10 μm). The double ELS design is optimized for different electrode geometrical parameters with tolerances of ±1 mm in electrode thickness, electrode aperture, inter electrode distance, and ±1° in electrode angle, providing a robust design. Experimental results obtained with the double ELS for the focused beam current and spot size, agree reasonably well with the simulations.  相似文献   

3.
A new plasma ion source for in situ keV He ion bombardment of solid state samples or thin films was designed and built for ion fluences between 1 × 10(12) and 1 × 10(17) ions/cm(2). The system was designed to be mounted to different diffraction chambers for soft x-ray resonant magnetic scattering. Without breaking the vacuum due to He-ion bombardment, structural and magnetic modifications of the samples can be studied in situ and element specifically.  相似文献   

4.
基于磁质谱离子光学成像聚焦原理对其离子光学系统、离子源和质量分析器的物理参数及几何结构尺寸进行优化,研制了新型小型磁偏转质谱计,其质量为4.3 kg,体积为(220×164×162) mm3,功耗为25 W。对质谱计的质量范围、灵敏度、分辨能力、最小可检漏率和稳定性等性能指标开展实验研究。结果表明,该质谱计的质量范围为1~134 u,大通道和小通道50%峰高处的分辨能力分别为56和13,对氩气、氮气和氦气的灵敏度分别为1.63×10-4、1.17×10-4、2.3×10-5 A/Pa,最小可检漏率为1.24×10-10 Pa·m3/s,仪器在3.5 h内的稳定性为2.5%。  相似文献   

5.
We report on experiments with a new superconducting electron beam ion source (EBIS-SC), the Dresden EBIS-SC, with the objective to meet the main requirements for their application in particle-therapy facilities. Synchrotrons as well as innovative accelerator concepts, such as high-gradient linacs which are driven by a large-current cyclotron (CYCLINACS) and direct drive RF linear accelerators may benefit from the advantages of EBISs in regard to their functional principle. First experimental studies of the production of low-Z ions such as H(+), H(2)(+), H(3)(+), C(4+), and C(6+) are presented. Particular attention is paid to the ion output, i.e., the number of ions per pulse and per second, respectively. Important beam parameters in this context are, among others, ion pulse shaping, pulse repetition rates, beam emittance, and ion energy spread.  相似文献   

6.
A detailed experimental and simulation study of the extraction of a 24 keV He(+) beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 π mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.  相似文献   

7.
The ion source is one of the key devices for the high-intensity cyclotron, which exerts influence on the beam intensity and applications of the machine. The H(-) multi-cusp ion source developed at China Institute of Atomic Energy has been used to perform experimental study on beam intensity and emittance versus the bias voltage, arc power, lens voltage, and pressure of the ion source. Up to now, 18 mA H(-) ion beam with emittance of 0.93 πmm mrad (four times RMS normalized emittance) was obtained from this ion source through the in-depth study and optimization on some essential factors affecting the beam intensity and quality. The paper will present the experimental study on the ion source as well as the beam test results.  相似文献   

8.
Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.  相似文献   

9.
A measurement setup is presented that allows for a complete and non-destructive material characterization of electrochemically deposited thermoelectric material. All electrical (Seebeck coefficient α, electrical conductivity σ), thermal (thermal conductivity λ), and thermoelectric (figure of merit ZT) material parameters are determined within a single measurement run. The setup is capable of characterizing individual electrochemically deposited Bi(2+x)Te(3-x) pillars of various size and thickness down to a few 10 μm, embedded in a polymer matrix with a maximum measurement area of 1 × 1 cm(2). The temperature range is limited to an application specific window near room temperature of 10?°C to 70?°C. A maximum thermal flux of 1 W∕cm(2) can be applied to the device under test (DUT) by the Peltier element driven heat source and sink. The setup has a highly symmetric design and DUTs can be mounted and dismounted within few seconds. A novel in situ recalibration method for a simple, quick and more accurate calibration of all sensors has been developed. Thermal losses within the setup are analysed and are mathematically considered for each measurement. All random and systematic errors are encountered for by a MATLAB routine, calculating all the target parameters and their uncertainties. The setup provides a measurement accuracy of ±2.34 μV∕K for α, ±810.16 S∕m for σ, ±0.13 W∕mK for λ, and ±0.0075 for ZT at a mean temperature of 42.5?°C for the specifically designed test samples with a pillar diameter of 696 μm and thickness of 134 μm, embedded in a polyethylene terephthalate polymer matrix.  相似文献   

10.
11.
The progress of a 2.45 GHz high-current microwave ion source with permanent magnet for T(d,n)4He reaction neutron generator is reported in this paper. At 600 W microwave power and 22 kV extraction voltage, 90 mA peak hydrogen ion beam is extracted from a single aperture of 6 mm diameter. The beam emittance is measured using a simplified pepper-pot method. The (x,x(')) emittance and the (y,y(')) emittance for 14 keV hydrogen ion beam are 55.3pi and 58.2pi mm mrad, respectively. The normalized emittances are 0.302pi and 0.317pi mm mrad, respectively.  相似文献   

12.
The deuteron injector developed for the PKUNIFTY (Peking University Neutron Imaging Facility) has been installed and commissioned at Peking University (PKU). The injector system must transfer 50 keV 50 mA of D(+) ion beam to the entrance of the 2 MeV radio frequency quadrupole (RFQ) with 10% duty factor (1 ms, 100 Hz). A compact 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) ion source and a 1.36 m long low energy beam transport (LEBT) line using two solenoids was developed as the deuteron injector. A φ5 mm four-quadrant diaphragm was used to simulate the entrance of RFQ electrodes. The beam parameters are measured after this core with an emittance measurement unit (EMU) and a bending magnet for ion fraction analysis at the end of injector. During the commissioning, 77 mA of total deuteron beam was extracted from PMECR and 56 mA of pure D(+) beam that passed through the φ5 mm four-quadrant diaphragm was obtained at the position of RFQ entrance with the measured normalized rms emittance 0.12-0.16π?mm?mrad. Ion species analysis results show that the deuteron fraction is as high as 99.5%. All of the parameters satisfy PKUNIFTY's requirements. In this paper, we will describe the deuteron injector design and report the commissioning results as well as the initial operation.  相似文献   

13.
The versatile ion source (VIS) is an off-resonance microwave discharge ion source which generates a slightly overdense plasma (n(e) ≈ 10(17) cm(-3)) operating at 2.45 GHz and producing more than 50 mA of proton beams. A detailed characterization of the source, by operating between 60 and 75 kV, in terms of emittance, current extracted and proton fraction is reported below. Moreover, passive techniques (alumina coating of the plasma chamber walls, BN disks at the injection and extraction endplates) have been used to improve the performance of the source, increasing the electron density for a more efficient ionization. The know-how achieved with the VIS source may be useful for the different project, particularly for the European spallation source.  相似文献   

14.
An energetic helium neutral beam is involved in the beam neutralization measurement system of alpha particles confined in a DT fusion plasma. A full size strong-focusing He(+) ion source (2 A, the beam radius of 11.3 mm, the beam energy less than 20 keV). Present strong-focusing He(+) ion source shows an emittance diagram separated for each beamlet of multiple apertures without phase space mixing, despite the space charge of a beamlet is asymmetric and the beam flow is non-laminar. The emittance of beamlets in the peripheral region was larger than that of center. The heat load to the plasma electrode was studied to estimate the duty factor for the ITER application.  相似文献   

15.
The design of the ion injection line connecting the electron beam ion source (EBIS) charge breeder and the Californium Rare Isotope Breeder Upgrade radio frequency quadrupole cooler-buncher at the Argonne Tandem Linear Accelerator System was investigated with particle tracking simulations. The injection line was configured to accommodate several differential pumping sections, individual optical components were optimized to minimize emittance growth, and the ion beam parameters were matched with the EBIS electron beam acceptance to minimize losses upon injection.  相似文献   

16.
As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita et al. [Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010)]. Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.  相似文献   

17.
One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.  相似文献   

18.
平行式Schmidt型龙虾眼X射线光学系统研究   总被引:3,自引:0,他引:3  
龙虾眼X射线系统是实现大视场X射线成像的有效手段。现研制了由多组平行玻璃平板构成的Schmidt型X射线龙虾眼光学系统,开展了X射线聚焦和成像的演示实验。基于掠入射反射理论,以210μm厚的超光滑平板玻璃作为光学元件,通过堆叠的方式制作了放大倍数为1的演示系统。用8keV的X射线光源对系统进行了聚焦和实验,直径280μm的光源聚焦半高宽约为320μm,与理论模拟结果基本一致。利用X射线背光照明,得到2mm×2mm大小图样的成像。实验结果表明,该龙虾眼光学系统可以在几毫米视场下达到百微米分辨。  相似文献   

19.
A 14 MeV medical cyclotron with the external ion source has been designed and is being constructed at China Institute of Atomic Energy. The H(-) ion will be accelerated by this machine and the proton beam will be extracted by carbon strippers in dual opposite direction. The compact multi-cusp H(-) ion source has been developed for the cyclotron. The 79.5 mm long ion source is 48 mm in diameter, which is consisting of a special shape filament, ten columns of permanent magnets providing a multi-cusp field, and a three-electrode extraction system. So far, the 3 mA∕25 keV H(-) beam with an emittance of 0.3 π mm mrad has been obtained from the ion source. The paper gives the design details and the beam test results. Further experimental study is under way and an extracted beam of 5 mA is expected.  相似文献   

20.
建立在线固相萃取即柱切换LC-MS/MS方法,分析吸毒者尿样中的吗啡、O6-单乙酰吗啡、可待因、乙酰可待因。以吗啡-d3为内标,预处理柱为Oasis HLB 2.1 mm×20 mm×25 μm,分析柱为Xterra MS C18 2.1 mm×150 mm×3.5 μm,用水作预处理流动相,分析流动相用含甲酸铵和甲酸的水、乙腈梯度洗脱,质谱采用电喷雾离子源,正离子MRM扫描。100 μL尿样直接进样分析,尿样中吗啡、O6-单乙酰吗啡、可待因、乙酰可待因的检测限为 0.3~1 μg/L,线性关系良好,相关系数γ在0.999 1以上。  相似文献   